48511 Warm Springs Blvd, Suite 206 Fremont, CA 94539, USA
Tel: (510)490-8024, Fax: (510)623-7268
E-Mail: irda-support@actisys.com
Web: www.actisys.com
Release 1.5a 2003. 7. 15 1
ACTiSYS Corporation
Copyright (C) 2002-2003 ACTiSYS Corp.
ACTiSYS ACTiSYS ACT-IR2000UL Series User’s Manual
FCC & VCCI Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1)This device may not cause harmful interference, and (2)this device must accept any interference
received, including interference that may cause undesired operation.
WARNING-FCC Regulations state that any unauthorized changes or modifications to this
equipment not expressly approved by the manufacturer could void the user authority to operate this
equipment
NOTE: This equipment has been tested and found to comply with the limits for Class B digital
device, pursuant to Part 15 of the FCC Rules. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will
nor occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
-Increase the separation between the equipment and receiver.
-Reorient or relocate the receiving antenna.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-Consult the dealer or an experienced radio/TV technician for help.
This equipment is in the 2nd Class category (information equipment to be used in a residential area
there to) and conforms to the standards set by the Voluntary Control Council For Interference by
Data Processing Equipment and Electronic Office Machines aimed at preventing radio interference
in such residential area.
When used near a radio or TV receiver, it may become the cause of radio interference. Read the
instructions for correct handling.
NOTE: Must be used with shielded cable only.
FOR YOU RECORDS.....
For your assistance in reporting this product in case of loss or theft, please record below the model
number and serial which are located on the bottom of the case. Please retain this information.
Model Number Serial Number
Date of Purchase Place of Purchase
All indicated copyrights and trademarks in the following pages are copyrights and trademarks of
their respective corporations.
Release 1.5a 2003. 7. 15 2
ACTiSYS Corporation
ACTiSYS
1 TABLE OF CONTENTS
ACTiSYS ACT-IR2000UL Series
User’s Manual
TABLE OF CONTENTS............................................................................................................................................ 3
3 PACKING CHECK LIST .......................................................................................................................................... 4
4 SYSTEM REQUIREMENTS..................................................................................................................................... 4
13 WARRANTY INFORMATION .............................................................................................................................. 18
14 CONTACT INFORMATION .................................................................................................................................. 19
Release 1.5a 2003. 7. 15 3
ACTiSYS Corporation
ACTiSYS
ACTiSYS ACT-IR2000UL Series
User’s Manual
2 INTRODUCTION
ACTiSYS IR2000UL is an advanced wireless Fast Infrared USB adapter designed to replace the serial
port or FIR controller based FIR/SIR wireless peripheral through the PC USB (Universal Serial Bus)
port. Taking advantage of the true plug-and-play nature and the high bandwidth of USB, IR2000UL
offers the easiest conversion of existing wireless to the legacy-free personal computer platform with
the following features:
Fully compliant to USB specification 1.1 and IrDA specification 1.1
Full-speed (12 Mbps) USB device operation
Supports FIR (4Mbps) and all SIR speeds (9.6, 19.2, 38.4, 57.6 and 115.2Kbps).
Bus-powered device. Obtain power from USB port. No external power supply required.
Low power consumption in standby mode ( Standby current is less than 0.5 mA
Not occupy PC's COM or Parallel port and has no complicated hardware port and resource
setting and conflict, such as IO address / IRQ / DMA numbers.
True PNP (Plug And Play) device. Without re-installing USB driver when re-plugs in.
package size: 2.4"L x 1.4"W x 0.74"H, 2.4 oz (65.0 gr)
3 PACKAGING CHECK LIST
The package includes
1. ACT-IR2000UL USB Dongle
2. ACT-USB Adapter Driver and CD for User’s manual.
4 SYSTEM REQUIREMENTS
To use ACT-IR2000UL, your computer MUST meet the following requirements.
1. Windows 98SE/ME/2000/XP.
2. One unoccupied USB port.
5 BIOS SETUP
Before you use this device, You MUST enable your computer USB port in BIOS Settings.
Release 1.5a 2003. 7. 15 4
ACTiSYS Corporation
ACTiSYS
ACTiSYS ACT-IR2000UL Series
User’s Manual
6 ACT-IR2000UL SERIES DRIVER INSTALLATION FOR WINDOWS 2000/ME/98SE
Following are the instructions to properly install the ACTiSYS ACT-IR2000UL Series under, Windows 2000,
Windows ME, and Windows 98SE.
Important: Do
smooth installation.
1. Insert the attached CD to
CD-ROM, Windows will
display install manual.
Please click Installation
then will execute
InstallShield Wizard.
Please Click on Next to
continue.
NOT
use Windows’ Native Driver. Please
use the driver on this CD
to assure a
2. The Installer will install
Actisys IR2000UL in the
Destination Folder. To
install to a different folder,
click Browse and select
one. To continue, click on
Next.
Release 1.5a 2003. 7. 15 5
ACTiSYS Corporation
ACTiSYS
3. To complete the
installation, plug the
ACTiSYS
ACT-IR2000UL Series
into the USB port. If the
Actisys ACT-IR2000UL
Series is already plugged
in, remove it then
re-insert it. Click on
Finish to continue.
4. Windows will now detect
ACTiSYS ACT-IR2000UL Series
User’s Manual
the ACTiSYS
ACT-IR2000UL Series.
In some operating
systems, you may need
to restart your computer.
If so, click “Yes” to
continue and the
Installation is now
complete.
Release 1.5a 2003. 7. 15 6
ACTiSYS Corporation
Loading...
+ 13 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.