ACTiSYS ACT IR100SLM User Manual

The Wireless Connectivity Expert
48511 Warm Springs Blvd., Suite 206, Fremont CA 94539
Tel: (510) 490-8024 Fax: (510) 623-7268
Website: http://www.actisys.com/
E-mail: irda-info@actisys.com
ACT-IR100SL and
ACT-IR100SL-M
User’s Manual
(IrDA Intelligent RS232 Adapters)
© Copyright 2000-2002 ACTiSYS Corporation,
All Rights Reserved
May 27, 2002 Ver. 1.20
ACT-IR100SL and IR100SL-M User’s Manual
FCC & VCCI Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. WARNING-FCC Regulations state that any unauthorized changes or modifications to this equipment not expressly approved by the manufacturer could void the user authority to operate this equipment
NOTE: This equipment has been tested and found to comply with the limits for Class B digital device, pursuant to Part 15 of the FCC Rules. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will nor occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Increase the separation between the equipment and receiver.
-Reorient or relocate the receiving antenna.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
This equipment is in the 2nd Class category (information equipment to be used in a residential area there to) and conforms to the standards set by the Voluntary Control Council For Interference by Data Processing Equipment and Electronic Office Machines aimed at preventing radio interference in such residential area. When used near a radio or TV receiver, it may become the cause of radio interference. Read the instructions for correct handling.
NOTE: Must be used with shielded cable only.
FOR YOU RECORDS.....
For your assistance in reporting this product in case of loss or theft, please record below the model number and serial which are located on the bottom of the case. Please retain this information.
Model Number Serial Number
Date of Purchase Place of Purchase
All indicated copyrights and trademarks in the following pages are copyrights and trademarks of their Respective corporations.
- 1 -
Version 1.20
May 27, 2002
ACT-IR100SL and IR100SL-M User’s Manual
TABLE OF CONTENTS
PRECAUTIONS........................................................................................................... 3
1. Featarus.................................................................................................................. 4
2. Overview................................................................................................................. 6
3. Applications........................................................................................................... 7
Embedded IrDA protocol stack
3.1
SIR IrPHY encoder-decoder
3.2
............................................................................ 7
................................................................................. 7
4. Operation Setting, EEPROM, and other optional hardware............................... 9
Serial EEPROM
4.1
................................................................................................... 9
Baud Rate Setting
4.2
Ignore DSR
4.3
Ignore CTS
4.4
EEPROM Function Disable
4.5
On Line Change Host Speed and Hardware Flow Control/Connection Control
4.6
RS-232C DTE DB-9P Connector
4.7
........................................................................................................ 11
........................................................................................................ 11
............................................................................................. 10
................................................................................ 12
... 13
......................................................................... 14
5. How to Connect IR100S-L/LM with host Device................................................ 15
OTHER ACTiSYS IrDA PRODUCTS........................................................................ 17
LIMITED WARRANTY............................................................................................ 18
- 2 -
May 27, 2002
Version 1.20
ACT-IR100SL and IR100SL-M User’s Manual
PRECAUTIONS
To ensure trouble-free operation, please observe the following precautions: Optical communications are easily affected by external light sources, weak batteries, transfer distance, transfer angle, etc. Any of these conditions may cause a data transfer failure, incomplete, missing or incorrect data. Make sure that the wireless interface is away from direct sunlight and other strong light source.
Do not terminate arbitrarily during file transfer process between DUT and computers until
!"
finished.
Otherwise DUT internal data integrity may be damaged, which is due to the violation of
DUT’s. Do not expose the unit to moisture, as this will damage the internal circuitry.
!"
Do not expose the unit to extreme temperatures. It should not be placed in direct sunlight or
!"
in a closed vehicle, neither should it be placed near heaters nor other heat sources. Do not store the unit in a humid or dusty place.
!"
Use a soft, dry cloth to clean the unit. Do not use a wet cloth or any solvent.
!"
Do not drop the unit or handle the unit carelessly.
!"
CAUTION:
Never touch the pins of computer connection terminal. The internal circuits can be damaged
!"
by a static electricity discharge. If this device requires any servicing, use only an ACTiSYS service dealer, an ACTiSYS approved service facility, or an ACTiSYS repair service. When exchanging data with host computer, be sure the appropriate serial communication
!"
port is available and is not in conflict with other peripheral device or software.
- 3 -
May 27, 2002
Version 1.20
1. Features
Support IrDA standard including:
- IrLAP
- IrLMP
- TinyTP
- IrCOMM
- IrOBEX transport
Other standards:
- IrLPT
IrDA baud rate supported:
- 9.6kbps
- 19.2kbps
- 38.4kbps
ACT-IR100SL and IR100SL-M User’s Manual
- 57.6kbps
- 115.2kbps
IrDA Primary/Secondary Mode supported:
- IR100SL : Secondary Mode only
- IR100SL-M : Both Primary and Secondary Mode supported, and mode automatically switched upon IrDA protocol negotiation with the other device
Host Interface :
- Full-duplex asynchronous serial (TXD, RXD)
(Or simplex TXD only and software flow control with RXD.)
- Hardware flow control (RTS, CTS)
- Optional line status for link control (DTR, DSR)
- Other optional inputs (RI, CD)
- Designed for use in RS232C level and that it is in DTE (Data Terminal Equipment) configuration.
- 4 -
May 27, 2002
Version 1.20
Host interface baud rate supported:
- 1.2kbps
- 2.4kbps
- 4.8kbps
- 9.6kbps
- 19.2kbps
- 38.4kbps
- 57.6kbps
- 115.2kbps
ACT-IR100SL and IR100SL-M User’s Manual