+V
Sounder
ACTSmart Standalone Installation Diagram
Default configuration for
AUX I/O 2 is Door Alarm.
BATCH:
PRODUCT :
SERIAL NUMBER :
01XX-
ACTSmart REV1.3
00XXX
0 1 2 3 4 5 6 7 8 9
The Aux I/O Output is an open
collector output capable of
sinking 100mAmps.
- 15 -
Door Release Button
Default configuration
for Programmable Input
is Door Release Button.
Door
Contact
Default configuration for
AUX I/O 1 is Door Contact.
+
1A 125VAC
1A 30VDC
OMRON
5A 30VDC
5A 250VAC
B
A
Aux I/O 2
Programmable
Input
Aux I/O 1
OMRON
12-24V
DC/AC
RACK
12V = DC
SCH
5A/250V ~AC
0V
N/
O
COMM
N/C
The ACTSmart may be powered
from 12 or 24V AC or DC for
Standalone operation.
+12V
Power
Supply Unit
0V
Tamper
Volt-Free
Tamper Contacts
Important!
Always Place Varistor
Across Lock Terminals
Note: To program the various Input and
Output operations for the ACTSmart unit,
please refer to page 10.
This illustration shows wiring
for normally de-energised locks.
If normally energised locks are
required, use the N/C relay contact.
- 15 -