+V
Sounder
ACTSmart Standalone Installation Diagram
Default configuration for AUX I/O 2 is Door Alarm.
BATCH:
PRODUCT : SERIAL NUMBER :
01XX-
ACTSmart REV1.3
00XXX
0 1 2 3 4 5 6 7 8 9
The Aux I/O Output is an open collector output capable of sinking 100mAmps.
- 15 -
Door Release Button
Default configuration for Programmable Input is Door Release Button.
Door Contact
Default configuration for AUX I/O 1 is Door Contact.
+
1A 125VAC
1A 30VDC
OMRON
5A 30VDC 5A 250VAC
B A
Aux I/O 2
Programmable Input
Aux I/O 1
OMRON
DC/AC
RACK
12V = DC
SCH
5A/250V ~AC
0V
N/
O
COMM
N/C
The ACTSmart may be powered from 12 or 24V AC or DC for Standalone operation.
+12V
Power
Supply Unit
0V
Tamper
Volt-Free Tamper Contacts
Important!
Always Place Varistor Across Lock Terminals
Note: To program the various Input and Output operations for the ACTSmart unit, please refer to page 10.
This illustration shows wiring for normally de-energised locks. If normally energised locks are required, use the N/C relay contact.