ACT ACTPRO PRODUCT RANGE User Manual

Page 1
Wiring for Entry/Exit Readers
ACTPro Product Range
1030/1040/1050/1060
ACT1050 Pin and Proximity
Reader (Entry)
ACT1030 Proximity
Reader (Exit)
Wire both readers in parallel but leave the SENSE line on the Exit reader unconnected.
For Wiegand readers . Wire both readers in parallel but connect D0 line of the exit reader into the SENSE line on the controller,leave the SENSE line on the Exit reader unconnected.
Wiring for Clock and Data / Wiegand Reader
White Green
2 31
5 64
8 97
0
Sense Clock Data +5v 0v Red Led Grn Led
Card/Prox Reader
Blue Red Black Brown Yellow Orange
The standard wiring colours for ACTPro Proximity and Pin readers is shown above. Readers should be a maximum of 30m from the controller when powered
Sense Clock / Data1 Data / Data 0 +5v 0v Red Led Grn Led (Buzzer Ctrl)
from +5V and a maximum of 100m when powered from +12V.
The above diagram is valid only for clock-and-data type readers.
The +5V reader supply on ACT controllers is normally rated at 100mA. Typically this is sufficient to power 2 ACT readers. Note however that readers from other manufacturers may need to be powered separately if their current requirements exceed this or if they require 12V.
OMRON
02X X-1
AC TP ro R E V 1.3
00X XX X
0V
Red L ED
Grn L ED
Buzz Ctrl
Rear view of ACTPro 1040/1050/1060 connected to the ACT2000/1000/DS100
B AT C H:
P RO DUC T :
S ER IA L NUM BER:
0 1 2 3 4 5 6 7 8 9
1A 125VAC
1A 30VDC
OMRON
5A 30VDC 5A 250VAC
5-12V dc
Data / D0
Clock / D1
Sense
Internal buzzer is activated by applying 0V to Buzz Ctrl
U nit 8 T allaght B usines s Centre, W hites tow n, T allaght, Dublin 24, Ireland. Telephone: 353 1 462 2585. T elefax : 353 1 462 2587. E -mail: sa les @ a cces scontrol. ie W eb: ww w.a cces scontrol. ie