ACR Electronics RCL-50B User Manual

PRODUCT SUPPORT MANUAL
RCL-50 // Remote Control Searchlight System
Model No.: RCL-50 Product No.: 1939.3, 1940.3
ACR Electronics, Inc., // 5757 Ravenswood Road // Fort Lauderdale // FL // 33312-6645
T: +1 (954) 981-3333 // F: +1(954) 983-5087 // www.acracrtex.com
CAUTION: Before proceeding to install, test or use your new ACR
Electronics product, please read this Product Support Manual in its entirety. If you have questions regarding the contents of the manual, please contact our
Technical Service Department at ACR Electronics, Inc., Telephone +1 (954) 981-3333 or email service@acrartex.com. Please be ready to provide the technician with the page number you wish to discuss. If you have a question that is not covered in the manual, please visit our website and access the Frequently Asked Questions (FAQs) section for further information or call our Technical Service Department. The website address is www.acrartex.com. If in the future you lose this manual, you may access and print a replacement on the ACR website.
Table of Contents
SECTION 1- FOREWORD _____________________________________ 3
SECTION 2- GENERAL ________________________________________ 4
SECTION 3- SEARCHLIGHT ____________________________________ 4
SECTION 4- REMOTE CONTROL SYSTEM _________________________ 5
SECTION 5- URP-102 POINT PAD™ _____________________________ 5
SECTION 6- URC-102 Master Controller _________________________ 9
APPENDIX B- BULB REPLACEMENT PROCEDURE _________________ 14
APPENDIX C- PRODUCT COMPONENTS ________________________ 15
APPENDIX E - WARRANTY, NOTICES ___________________________ 18
PLEASE READ ALL WARNINGS, CAUTIONS AND
NOTES CAREFULLY
Y1-03-0141F 2
SEARCHLIGHT
RCL-50B, 12/24V
REMOTE CONTROL SEARCHLIGHT SYSTEM
Figure 1- Remote Control Searchlight System
SECTION 1 - FOREWORD
Congratulations and thank you for purchasing the ACR RCL-50B Searchlight. The combination of computer aided design, high quality raw materials, and quality-controlled manufacturing produce a superior product. The Test Facility at ACR can reproduce some of the harshest environmental conditions known to man. This assures that the products we produce can stand up to the tough marine environment. With proper care and maintenance your searchlight will be in service for years to come.
ACR is proud to be ISO 9001 certified, the International Standard for Quality.
Y1-03-0141F 3
SECTION 2 - GENERAL
The RCL-50B was specially designed for mariners who require a high intensity remote controlled searchlight that can stand up to the tough marine environment.
The RCL-50B searchlight system contains a narrow beam searchlight that produces 80,000 peak candle power by combining a 55W halogen lamp on the 12V version or a 70W halogen lamp on the 24V version with our unique optical quality parabolic reflector.
All functions of the searchlight can be electrically operated by remote control from the pilot area of the vessel using the URP-102 Point Pad™, URC-102 Master Controller, and interconnect cable supplied with the RCL-50B. Searchlights equipped with the URC-102 Master Controller now have ACR’s unique XRCiZ feature. The XRCiZ feature routinely operates all moving parts in the searchlight to keep the motors and drive mechanism freely running.
SECTION 3 - SEARCHLIGHT
The sleek design and modern construction of the searchlight body makes it attractive for recreational and commercial vessels. The searchlight is totally enclosed and is made of rugged aluminum alloy. It is gasketed and finished to be resistant to the weather.
Mounting
Make sure the area is clean and dry. The searchlight can be mounted where desired, using appropriate length 3/16" diameter, stainless steel fasteners. four (4) nylon shoulder washers are supplied with the RCL-50B searchlight. the nylon washers prevent a galvanic reaction between the mounting hardware and the base of the searchlight. Be sure these washers have been inserted in the base mounting holes and that the mounting base gasket is securely in place before bolting down. Silicone grease should be applied to the bottom of the gasket to help in waterproofing the unit. When mounting, be sure that the searchlight is able to rotate 360° without hitting any obstructions. For the drilling hole pattern, refer to the searchlight mounting template, supplied in the mounting templates.
CAUTION: Do not mount the searchlight upside down. Moisture will not be able to
drain from the inverted light head assembly. NOTE: The searchlight should be left uncovered if the XRCiZ™ feature is enabled.
Y1-03-0141F 4
SECTION 4 - REMOTE CONTROL SYSTEM
The Remote Control System consists of the URC-102 Master Controller and the URP­102 Point Pad™. This system is compatible with 12 VDC and 24 VDC systems without modification. The remote control system may be used with 12 V or 24 V searchlights,
Only the lamp in the light head assembly must be changed to match the voltage rating.
SECTION 5 - URP-102 POINT PAD™
Case Options
The URP-102 Point Pad™ is supplied as a surface mount unit (see Figure 4). A flush mount option is provided (see Figure 5). To switch mounting options, unscrew the six (6) screws on the unit’s back plate and remove the front cover. Fit the Point Pad™ with the flush mount cover, replace the back plate, and screw the unit back together.
Mounting
Both the surface mount and flush mount options require access to the backside of the mounting location. Make sure there are no obstructions behind the area where the switch is to be located (e.g. bulkheads, wires, plumbing, or hardware). Check in advance that the coax cable from the master controller can be routed to this location. Generally, the Point Pad™ should be mounted in a protected area.
Install the surface mount Point Pad™ by drilling three (3) holes in the dashboard location using the Point Pad™ surface mount template supplied. Mount the Point Pad™ to the dashboard using the gasket, washers, and nuts supplied. Use a sealant around the bolt holes to protect from moisture intrusion.
When the flush mount option is selected, cut a rectangular hole in the dashboard location using the point pad™ flush mount template supplied in the mounting templates. Use the gasket, washers, nuts, and the two U-clamps provided to secure the Point Pad™. Use a sealant around the cut out to protect from moisture intrusion.
Connecting to the Master Controller
The Point Pad™ communicates with the Master Controller via standard television type RG-59 coaxial cable. The connectors are standard "F" type television connectors. The connector on the back of the Point Pad™ is located in the center of the panel for ease of installation. After the coax cable has been routed and the “F” connectors attached to the coax cable, simply screw the “F” connectors to the Master Controller and the Point Pad™. The cable and connectors are available either through ACR Electronics, your local Radio Shack or other sources of electronic hardware.
Y1-03-0141F 5
Loading...
+ 14 hidden pages