ACR Electronics RCL-100 SEARCHLIGHT User Manual

Product Support Manual
RCL-100D™ Remote Control Searchlight Master Controller Point Pad
Y1-03-0138
Rev. K
ACR Electronics, Inc.
5757 Ravenswood Road
Fort Lauderdale, Fl 33312
Tel : +1(954) 981-3333
Fax: +1 (954) 983-5087
www.acrelectronics.com
Email: Info@acrelectronics.com
RCL-100D
TABLE OF CONTENTS
SECTION
1.0 Forward 1
2.0 General 2
3.0 Searchlight 2
4.0 Remote Control System 2
5.0 URP-102 Point Pad™ 3
6.0 URC-102 Master Controller 11
7.0 RCL-100D Specifications 15
8.0 Bulb Replacement 17
9.0 RCL-100D Searchlight Components 17
10.0 Remote Control System Components 18
FIGURES TITLE PAGE
Figure 1 Remote Control Searchlight System 1 Figure 2 Point Pad™ Connection Block Diagram 4 Figure 3 URP-102 Point Pad™ Functions 5 Figure 4 URP-102 Point Pad™ Surface Mount Case 6 Figure 5 URP-102 Point Pad™ Flush Mount Case 7 Figure 6 URP-102 Point Pad™ Surface Mount Case w/Gasket and Flush Mount Case with Gasket 8 Figure 7 URC-102 Master Controller Wiring Diagram 11 Figure 8 URC-102 Master Controller 12 Figure 9 Searchlight User Replaceable Parts List 14
TITLE PAGE
i
Y1-03-0138 Rev. K
RCL-100D, 12/24V
REMOTE CONTROL SEARCHLIGHT SYSTEM
1.0 FORWARD
Congratulations and thank you for purchasing the ACR RCL-100D Searchlight. The combination of computer aided design, high quality raw materials, and quality-controlled manufacturing produce a superior product. The Test Facility at ACR can reproduce some of the harshest environmental conditions known to man. This assures that the products we produce can stand up to the tough marine environment. With proper care and maintenance your searchlight will be in service for years to come.
ACR is proud to be ISO 9001 certified, the International Standard for Quality.
Note: It is important to read this entire instruction manual carefully for proper installation and operation of this product.
FIGURE 1: REMOTE CONTROL SEARCHLIGHT SYSTEM
1
Y1-03-0138 Rev. K
2.0 GENERAL
The RCL-100D was specially designed for mariners who require a high intensity remote controlled searchlight that can stand up to the tough marine environment.
The RCL-100D Searchlight System contains a narrow beam searchlight that produces 200,000 peak candle power by combining two 55W halogen lamps with our unique optical quality parabolic reflectors.
All functions of the Searchlight can be electrically operated by remote control from the pilot area of the vessel using the URP-102 Point Pad™, URC-102 Master Controller, and interconnect cable supplied with the RCL-100D. Searchlights equipped with the URC-102 Master Controller now have ACR's unique XRCiZ feature. The XRCiZ feature routinely operates all moving parts in the Searchlight to keep the motors and drive mechanism freely running.
3.0 SEARCHLIGHT
The sleek design and modern construction of the Searchlight body makes it attractive for recreational and commercial vessels. The Searchlight is totally enclosed and is made of rugged aluminum alloy. It is gasketed and finished to be resistant to the weather.
Mounting
Make sure the area is clean and dry. The Searchlight can be mounted where desired, using appropriate length 3/16" diameter, stainless steel fasteners. Four (4) nylon shoulder washers are supplied with the RCL-100D Searchlight. The nylon washers prevent a galvanic reaction between the mounting hardware and the base of the Searchlight. Be sure these washers have been inserted in the base mounting holes and that the mounting base gasket is securely in place before bolting down. Silicone grease should be applied to the bottom of the gasket to help in waterproofing the unit. When mounting, be sure that the Searchlight is able to rotate 360° without hitting any obstructions. For the drilling hole pattern, refer to the Searchlight Mounting Template, supplied in the Mounting Templates.
CAUTION: Do not mount the searchlight upside down. Moisture will not be able to drain from the inverted light head assembly.
NOTE
: The Searchlight should be left uncovered if the XRCiZ feature is enabled.
4.0 REMOTE CONTROL SYSTEM
The Remote Control System consists of the URC-102 Master Controller and the URP-102 Point Pad™. This system is compatible with 12 VDC and 24 VDC systems without modification. The Remote Control System may be used with 12 V or 24 V Searchlights, ONLY
THE LAMPS IN THE LIGHT HEAD ASSEMBLY MUST BE CHANGED TO MATCH THE VOLTAGE RATING.
2 Y1-03-0138 Rev. K
5.0 URP-102 POINT PAD™
Case Options
The URP-102 Point Pad™ is supplied as a surface mount unit (see Figure 4). A flush mount option is provided (see Figure 5). To switch mounting options, unscrew the six (6) screws on the unit’s back plate and remove the front cover. Fit the Point Pad™ with the flush mount cover, replace the back plate, and screw the unit back together.
Mounting
Both the surface mount and flush mount options require access to the backside of the mounting location. Make sure there are no obstructions behind the area where the switch is to be located (e.g. bulkheads, wires, plumbing, or hardware). Check in advance that the coax cable from the Master Controller can be routed to this location. Generally, the Point Pad™ should be mounted in a protected area.
Install the surface mount Point Pad™ by drilling 3 holes in the dashboard location using the Point Pad™ Surface Mount Template supplied in the Mounting Templates. Mount the Point Pad™ to the dashboard using the gasket, washers, and nuts supplied. Use a sealant around the bolt holes to protect from moisture intrusion.
When the flush mount option is selected, cut a rectangular hole in the dashboard location using the Point Pad™ Flush Mount Template supplied in the Mounting Templates. Use the gasket, washers, nuts, and the two U-Clamps provided to secure the Point Pad™. Use a sealant around the cut out to protect from moisture intrusion.
Connecting to the Master Controller
The Point Pad™ communicates with the Master Controller via standard television type RG-59 coaxial cable. The connectors are standard "F" type television connectors. The connector on the back of the Point Pad™ is located in the center of the panel for ease of installation. After the coax cable has been routed and the “F” connectors attached to the coax cable, simply screw the “F” connectors to the Master Controller and the Point Pad™. The cable and connectors are available either through ACR Electronics, your local Radio Shack or other sources of electronic hardware.
Additional Point Pads™ (up to three (3) Pads) may be used with one (1) Master Controller. A standard "T" connector or RG-59 television type "splitter" is used for each additional Point Pad (see Figure 2). Limit the total length of all coax cable used to 300 feet.
The URP-102 Point Pad™ is backwards compatible with all RCL-100/50 Searchlights and with the URC-101 Master Controller.
NOTE:
100 Master Controllers.
The URP-102 Point Pad™ is not recommended for use with the first generation URC-
3 Y1-03-0138 Rev. K
URC-102
Master
Controller Unit
Fuse
Power
Source
Single Point Pad
RG-59 Coaxial Cable
URP-102
Point Pad
Power
Source
RG-59 Coaxial Cable
URC-102
Master
Controller Unit
Fuse
“T” Conn. or Splitter
URP-102
Point Pad
Multiple Point Pad s
RG-59 Coaxial Cable
RG-59 Coax ial Cable
URP-102
Point Pad
FIGURE 2: POINT PAD™ CONNECTION BLOCK DIAGRAM