Acer P6600, P6500 Energy-related Product directive

Product type Projector
Manufacturer name, address
Acer Italy s.r.l, Via Lepetit, 40, 20020 Lainate (MI) Italy
Product model number P6500, P6600
Year of manufacture 2015
Off mode power consumption Not applicable
Networked standby mode power consumption
2.87 Watt
Power consumption of the product in networked standby if all wired network ports are connected and all wireless network ports are activated
Not applicable
For products with an display or light source, the total content of mercury is
45 mg
The default time after which the power management function, or similar function, has switched the equipment into standby mode
15 minutes
The default time after which the power management function, or similar function, has switched the equipment into off mode
Not applicable
The default time after which the power management function, or similar function, has switched the equipment into another condition which does not exceed the applicable power consumption requirements for off mode and/or standby mode when the equipment is connected to the mains power source.
15 minutes
The default time after which the power management function, or similar function, has switched the equipment into networked standby mode
15 minutes
Technical justification that the requirements set out in points 2(c) and/or 2(d) and/or 3(b), are inappropriate for the intended use of equipment
Not applicable
Measurement methodology for standby mode
According to IEC 62301:2011 and EN 50564:2011
Measurement methodology for off mode Not Applicable
Technical Documentation of (EC) No 1275/2008
Measurement methodology for networked standby mode
According to IEC 62301 and EN 50564
Description of how standby mode was selected or programmed
1. Plug in power cord, but no input source.
2. Will show the status by LED indicator. (LED will show in steady RED color)
Description of how off mode was selected or programmed
Not applicable
Sequence of steps for achieving a stable condition with respect to power demand
Allow the Test Unit to warm up (Power On) for a minimum of 20 minutes
Sequence of events leading to the condition where the equipment automatically changes to standby mode
1. To disable the network setting in OSD .
2. While system is on and with no singal after 15min, will automatically switch to standby mode, or
3. While Security is on and no entering password, system will automatically switch to standby mode.
Sequence of events leading to the condition where the equipment automatically changes to off mode
Not applicable
Sequence of events leading to the condition where the equipment automatically changes to networked standby mode
1. To enable the network setting in OSD .
2. While system is on and with no singal after 15min, will automatically switch to standby mode, or
3. While Security is on and no entering password, system will automatically switch to standby mode.
Notes regarding the operation of the equipment
Setting projector by OSD definition
Guidance on how to activate and deactivate wireless network ports
Not applicable
Test parameter for ambient temperature 25 ℃
Test parameter for test voltage 230 V
Test parameter for frequency 50 Hz
Test parameter for total harmonic distortion of the electricity supply system
0.03 %