The Altos R380 F3 is a robust two-socket 2U system that is ideal for almost any application. This dynamic system
can function as a head node, for virtualization purposes, or as a storage system for your HPC (High-Performance
Computing) and technical computing environments. Extremely expandable and highly efficient, this system is a
powerful core for your most demanding data-center needs.
Extremely powerful
The R380 F3 supports up to two Intel® Xeon® E5-2600 v3 product family processors, and high-performance DDR4
memory occupying twenty-four DIMM slots. There is no shortage of storage capability with up to twelve 3.5" or
twenty-four 2.5" front-accessible, hot-swap hard drives, two 2.5” internal drive bays and two 2.5” rear-accessible
hot-swap drive bay options. Hard drives can be configured in 12Gb/s SAS RAID and SAS HBA for increased
performance and data availability.
Highly efficient
As with all Acer rack servers, the R380 F3 uses only 80 PLUS-certified power supplies. This server can be equipped
with up to two 750 W or 1100 W 80 PLUS Platinum-level power supplies. Combine this with Load Reduced DIMM
memory modules and the latest power-saving chipset technologies, this system delivers maximum performance
with minimum power-draw. Six managed, hot-swappable fans keep the system running cool at all times.
Flexible and robust I/O
Qualified to work in any environment, this system has dual 10 Gigabit or Gigabit Ethernet connectors onboard. It
also has up to 7 PCIe 3.0 slots and 1 PCIe 2.0 slot, maximizing your expansion options. In addition, dedicated I/O
module and SAS module slots save customers valuable PCIe expansion. Users can rest assured the R380 F3 will
keep up in any high-performance scenario.
R380 F3
Page 2
Altos R380 F3 Specifications
Product views
Internal view
1. 2 x Intel
2. 24 x DDR4 ECC Registered/Load Reduced DIMMs
3. 2 x 750 W / 1100 W Platinum-level AC or 2 x 750 W Gold-level DC power supplies
(1+0/1+1 redundant, hot-swappable)
4. Onboard SATA RAID connections
5. 7 x PCIe 3.0 and 1 x PCIe 2.0 slots across three risers
1. Power button, LED indicators: power, HDD activity, LAN, system ID
2. Rack locking screw
3. Up to 12 x 3.5” SATA / SAS HDDs or 2.5” SSDs
4. Front USB 2.0
Front I/O (8 x 3.5”)
1. Power button, LED indicators: power, HDD activity, LAN, system ID
2. Front VGA and 2 x USB 3.0
3. Up to 8 x 3.5” SATA / SAS HDDs or 2.5” SSDs
4. Optional slimline optical drive
Front I/O (16 x 2.5”)
1. Power button, LED indicators: power, HDD activity, LAN, system ID
2. Front VGA and 2 x USB 3.0
3. Optional slimline optical drive
4. Up to 16 x 2.5” SATA / SAS HDDs and SSDs (with an option to replace four hard drives with four PCIe
SFF/NVMe SSDs)
3
Page 4
Altos R380 F3 Specifications
Front I/O (24 x 2.5”)
1. Power button, LED indicators: power, HDD activity, LAN, system ID
2. Rack locking screw
3. Up to 24 x 2.5” SATA / SAS HDDs and SSDs (with an option to replace four hard drives with four PCIe
SFF/NVMe SSDs)
4. Front USB 2.0
Rear View
Rear I/O
1. 2 x 750 W / 1100 W 80 PLUS Platinum-level AC or
2 x 750 W 80 PLUS Gold-level DC power supplies (1+0/1+1 redundant, hot-swappable)
2. Management port (RJ-45)
3. 3 x USB 3.0 ports
4. Video port
5. 2 x Gigabit or 10Gigabit LAN ports (RJ-45)
6. Serial Port B (optional)
7. PCIe expansion via riser cards
8. 2 x 2.5” SSDs (hot-swappable, optional)
9. Serial Port A (RJ-45)
4
Page 5
Altos R380 F3 Specifications
Product Specifications
What's New
New Intel
®
Xeon® E5-2600 v3 processors
DDR4 memory
Rear-accessible, hot-swappable drive bays
Supports four PCIe SFF/NVMe SSDs
USB 3.0 ports
Dual-port 10 Gigabit Ethernet on board
Smart Server Manager with improved management functionality
Processors and Chipset
Up to two Intel
Chipset: Intel
®
Xeon® E5-2600 v3 family processors
®
C612
Memory
24 x DDR4 Registered / Load Reduced DIMMs
Network Controllers
Dual-port Ethernet controller
Intel
®
X540 (10GbE) or Intel I350 (1GbE)
Storage
Hard disk form factor: 3.5” or 2.5”
Type: SAS / SATA / SSD with hot-plug capability
Front: up to 12 x 3.5” or 24 x 2.5” hard drives or SSDs (with an option to replace four hard drives with four
PCIe SFF/NVMe SSDs)
Rear: up to 2 x 2.5” SSDs (optional)
Internal: up to 2 x 2.5” SSDs (optional)
Slimline optical drive (optional)
Storage Controllers
Intel
®
C612 chipset with 10 x 6 Gb/s SATA ports
2 x single port SATA connectors
2 x 4-port mini SAS HD connectors
1 x eUSB 2x5 pin connector for 2mm low profile eUSB SSDs
Intel RSTe 4.1 embedded software SATA RAID
Intel Embedded Server RAID Technology 2 (ESRT2) 1.41 with optional RAID 5 key support
Optional Hardware SAS RAID with RAID 0, 1, 5, 6, 10, 50, 60 support
5
Page 6
Altos R380 F3 Specifications
Expansion slots
Three riser slots provide:
Riser slot 1:
3-slot riser card: 2 x PCIe
2-slot riser card: 1 x PCIe 3.0 x16 (x16 connector) and 1 x PCIe 3.0 x 8 (x8 connector)
Riser slot 2:
3-slot riser card: 2 x PCIe
2-slot riser card: 1 x PCIe 3.0 x16 (x16 connector) and 1 x PCIe 3.0 x 8 (x8 connector)
Riser slot 3:
2-slot riser card: 1 x PCIe 3.0 ×8 (x8 connector) and 1 x PCIe 2.0 x 4 (x8 connector)
1 x I/O module expansion slot
1 x SAS RAID module expansion slot
Management
Acer Smart Server Manager
Embedded BMC controller with IPMI 2.0 compatibility
System ID LED buttons, System Health LED
Smart Console remote monitoring and optional KVM over IP management to OS level
Optional Local Control Panel
®
3.0 ×8 (x16 connector) and 1 x PCIe® 3.0 ×8 (x8 connector), or
®
3.0 ×8 (x16 connector) and 1 x PCIe® 3.0 ×8 (x8 connector), or
BIOS
UEFI BIOS
SMBIOS 2.0
Deployment/Serviceability
BIOS Update Tool
IPMI Firmware Update Tool
Operating Systems
Windows Server 2012 R2
Red Hat Enterprise Linux 6.5
SUSE Linux Enterprise Server 11 SP3
VMware ESXi
™
5.5
Graphics
Integrated 2D video controller
16 MB DDR3 memory
Chassis/Form Factor
2U rack-optimized
6
Page 7
Dimensions
750 W SKU
439 (W) x 769 (D) x 89 (H) mm (17.25 x 30.25 x 3.5 inches)
1100 W SKU
439 (W) x 793.8 (D) x 89 (H) mm (17.25 x 31.25 x 3.5 inches)
System inlet temperature
Operating
10° - 35° C (50° - 95° F)
Non-operating
-40° - 70° C (-40° - 158° F)
Relative humidity
Non-operating
50 - 90 %
Acoustics
Idle
LWAd
< 7.0 BA
Operating
LWAd
< 7.0 BA
Power
Rated Steady –state
power
750 W or 110 W
Altos R380 F3 Specifications
Power Supply
1+0/1+1 redundant, hot-swappable power supply units. Three power supply options:
750 W 80 PLUS
1100 W 80 PLUS
®
Platinum-certified AC power supply
®
Platinum-certified AC power supply
750 W 80 PLUS® Gold-certified DC power supply
Security
Administrator/user password
Power-on password
Setup password
Device boot control
Secure command line interface (SSH)
Secure browser interface (Secure socket layer - SSL support)
Secure IPMI LAN interface (Authentication, Integrity, and Confidentiality algorithm)
Regulatory Compliant Standards
EMC
FCC (Class A)
CE (Class A)
BSMI (Class A)
CCC
Safety
MET
CB
Environmental Specifications
7
Page 8
Riser
Slot
Riser Card
Type
Location
Connector
Type
Bus
Width1
Voltage
CPU2
Add-in Card Form
Factor
1
3-slot Riser
Card
Top Slot
x16
PCIe® Gen3
x8
3.3V 1 Full height/Full length
Middle Slot
x16
PCIe® Gen3
x8
3.3V 1 Full height/Full length
Bottom Slot
x8
PCIe® Gen3
x8
3.3V 1 Full height/Half length
2-slot Riser
Card
Top Slot
x16
PCIe® Gen3
x16
3.3V 1 Full height/Full length
Bottom Slot
x8
PCIe® Gen3
x8
3.3V 2 Full height/Half length
2
3-slot Riser
Card
Top Slot
x16
PCIe® Gen3
x8
3.3V 2 Full height/Full length
Middle Slot
x16
PCIe® Gen3
x8
3.3V 2 Full height/Full length
Bottom Slot
x8
PCIe® Gen3
x8
3.3V 2 Full height/Half length
2-slot Riser
Card
Top Slot
x16
PCIe® Gen3
x16
3.3V 2 Full height/Full length
Bottom Slot
x8
PCIe® Gen3
x8
3.3V 2 Full height/Half length
3
Low profile
Riser Card
Top Slot
x8
PCIe® Gen2
x4
3.3V 2 Low-profile
Bottom Slot
x8
PCIe® Gen3
x8
3.3V 2 Low-profile
Altos R380 F3 Specifications
Technical specifications
PCIe® specifications
The primary I/O bus for the main board is PCIe Gen3. The following table lists the characteristics of the PCI-E bus
segments. Details about each bus segment follow the table.
NOTE: The signaling bit rate of PCI Express is8.0 Gbit/s one direction per lane for Gen 3.
NOTE:
1. Indicates the number of physical electrical lanes running to a PCIe
2. CPU 2 indicates that a second CPU is required to access that specific PCIe
®
connector.
®
slot.
3. If only one CPU is used:
It is not possible to use more than the top two slots on a 3-slot riser card or the top slot on a 2-slot riser
card (in riser slot 1).
Riser slot 2 and Riser slot 3 cannot be used.
Two riser card assemblies are used, one for slot 1, and a butterfly configuration for slots 2 and 3.
Riser slot 1
Riser slots 2 and 3
8
Page 9
Item
Description
Controller
Intel® C612 Platform Controller Hub
Simultaneous drive transfer channels
10 onboard SATA ports
AHCI SATA controller: 4 x SATA ports from the Mini SAS HD
connector and 2 x SATA ports on the server board
AHCI sSATA controller: 4 x SATA ports from the Mini SAS HD
connector on the server board.
Max throughput per channel
6 Gb/s
Data transfer method
Non-RAID mode
RAID mode
Drive type supported
Serial ATA
RAID levels support
Default: Intel ESRT2 SATA RAID 0, 1, 5, 10 (RAID 5 requires key) or
Intel RSTe software SATA RAID 0, 1, 5, 10 (Windows OS support only)
RAID function support
Supports multiple logical volumes
Setup through ROM based Array Configuration Utility
Installation scripting support
RAID OS support
Windows Server 2012 R2
Red Hat Enterprise Linux 6.5
SuSE Linux Enterprise Server 11
NOTE: Acer does not qualify mixed memory configurations of
memory type, capacity or make.
Population
Farthest fill first rule on any channel (populate blue slot /
Slot 1 first)
Install DIMMs in order (CPU-1: Channels A, B, C and D; CPU-
2: Channels E, F, G and H)
Only remove DIMM blanks when populating memory in that
slot
Maximum of 8 ranks can be installed on any one channel
Do not mix DIMM types (RDIMM or LRDIMM) and frequencies
or latencies within or across CPUs
Population per CPU by DIMM type listed below.
NOTE: Support for 16 / 32 / 64 GB DIMMs may vary by regional
availability.
A CPU must be populated for memory to be read.
Altos R380 F3 Specifications
Memory specifications and population
Memory support and population
10
Page 11
Altos R380 F3 Specifications
Independent mode:
•Also known as performance mode, each DDR channel is addressed individually via burst lengths of 8
bytes.
• All CPUs support SECDED ECC with x8 DRAMs.
• All CPUs support SDDC with x4 DRAMs.
Lockstep mode:
• Also known as RAS mode, each pair of channels shares a Write Push Logic unit to enable lockstep.
• Channels are paired together as a domain. For CPU1, channels A and B, and channels C and D. For
CPU2, channels E and F, and channels G and H.
•All CPUs support SDDC with x4 or x8 DRAMs.
Memory RAS mode:
• RAS mode that require matching populations.
• Same slot position across channels must hold the same DIMM type (ranks, banks, rows and column)
Intra-Socket Memory Mirroring mode:
•For mirroring mode, the memory image in channel A is maintained the same as channel C and channel
B is maintained the same as channel D. Therefore, the effective size of memory is reduced by one-half.
11
Page 12
2D Mode
2D Video Mode Support
8 bpp
16 bpp
24 bpp
32 bpp
640x480
X X X
X
800x600
X X X X 1024x768
X X X
X
1152x864
X X X
X
1280x1024
X X X X 1600x1200**
X X
Altos R380 F3 Specifications
•The DIMM configuration in mirrored channels must be identical. Channel A & channel C with identical
DIMMs and also channel B & channel D with identical DIMMs. The DIMM type, size, manufacturer should
be the same.
Rank Sparing mode:
•An unused spare rank is reserved on each channel. The spare rank is used to copy the contents of a failing
rank on the channel to keep a system working when a rank starts to fail. The reserved rank is not able to be
used before the other rank fail.
Memory Identification
Generally, there are some memory information printed on the label of DIMM, but different vendor may have
different format. For example:
4 GB 2R×4 PC4-14900R xx xx xxx
Integrated Graphics Core with 2D Hardware accelerator
DDR-3 memory interface with 16MB memory
Supports all display resolutions up to 1600 x 1200 16bpp @ 60 Hz
High speed Integrated 24-bit RAMDAC
Single lane PCIe host interface running a Gen1 speed
Supported video modes
12
Page 13
Loading
100%
50%
20%
10%
Minimum efficiency
91%
94%
90%
82%
Output power
10% load
20% load
50% load
100% load
Power factor
>0.65
>0.80
>0.90
>0.95
Parameter
Min
rated
Max
Start up Vac
Power off Vac
110 Vac
90 Vrms
100-127 Vrms
140 Vrms
85 Vac ± 4 Vac
75 Vac ± 5 Vac
220 Vac
180 Vrms
200-240 Vrms
264 Vrms
Frequency
47 Hz
50/60 Hz
63 Hz
Loading
Holdup time
750 W
70%
12 msec
1100 W
70%
10 msec
Loading
100%
50%
20%
10%
Minimum efficiency
88%
92%
88%
80%
Parameter
Min
Rated
VMax
DC voltage
-40.5 Vdc
-48 Vdc / -60 Vdc
-75 Vdc
Input current
24A
12.5A
Loading
Holdup time
70%
0.2 msec
Altos R380 F3 Specifications
Power specifications
750 W / 1100 W AC Platinum-certified power supply
Efficiency
Power factor
AC input voltage range
AC line holdup time
AC Line Inrush
Shall not exceed 55 A peak
750 W DC Gold-certified power supply
Efficiency
DC input voltage
DC holdup time
Acer server software utilities
Smart Console with optional iKVM management
Web-based management utility to simplify system management with embedded BMC, system monitoring and
alerting, event handling, remote power control and KVM-over-IP. Smart Console is OS independent and offers
virtual media through floppy, ODD, and removable disk.
Note:
The integrated BMC has support for basic and advanced server management features. Basic management
feature are available by default. Advanced management features are enabled with the addition of an
optionally installed RMM (Remote Management Module) module.
Two concurrent web sessions from up to two different users is supported.
Note: 32GB LRDIMM availability may vary by region.
Altos R380 F3 Specifications
Smart Server Manager
Offers 24-7 monitoring for system health and performance.
Delivers proactive event management features including system event logging, event handling from e-mail
and SNMP Trap (PET) alerting
Monitors onboard hardware, operating systems and virtual machines
Allows remote control from KVM and Power control
Satisfies management in web-based UI, role-based administration, and automated management scripts
Remote firmware deployment and scheduled updates
Customizable BIOS settings and deployment to networked nodes
*Note: Intel’s 10GbE and 40GbE cards vary in terms of their connector type.
Note: All cards marked (I/O module) indicate the card is inserted in the I/O module connector on the node. It does
not use the standard PCIe slot
InfiniBand
Note: All cards marked (I/O module) indicate the card is inserted in the I/O module connector on the node. It does
not use the standard PCIe slot
Management module
Service and support
Acer Servers offer a comprehensive service suite to take care of daily IT needs. Users can select the 3-year
standard warranty or choose extended warranties and services.
In a continuing effort to improve the quality of our products, information in this document is subject to change
without notice. Images shown are only representations of some of the configurations available for this model.
Availability may vary depending on region.
Microsoft and Windows are registered trademarks of Microsoft Corporation. Intel, the Intel logo, Xeon and Xeon
Inside are trademarks of Intel® Corporation.
NOTE: Extension warranty services may vary by country. Please contact Acer authorized resellers for more
information.
16
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.