CE Mark Declaration of Conformance for EMI and Safety (EEC)
This is to certify that this product complies with ISO/IEC Guide 22 and EN45014. It conforms to the
following EMC specifications:
EN55022(1988)/CISPR-22(1985) Class A
EN60555-2(1995) Class A
EN60555-3
IEC1000-4-2(1995) 4kV CD, 8kV AD
IEC1000-4-3(1995) 3V/m
IEC1000-4-4(1995) 1kV - (power line),
0.5kV - (signal line)
IEC 1000-4-6(1995) 3Vrms
This product complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC
Directive 89/336/EEC.
VCCI Class A Compliance (Japan)
Warranty
Accton warrants to the original owner that the product delivered in this package will be free from
defects in material and workmanship for a period of three (3) years from the date of purchase from
Accton or its Authorized reseller. For the warranty to apply, you must register your purchase by
returning the registration card indicating the date of purchase and including proof of purchase.
There will be a minimal charge to replace consumable components, such as fuses, power
transformers, and mechanical cooling devices. The warranty does not cover the product if it is
damaged in the process of being installed. Accton recommends that you have the company from
whom you purchased this product install it.
THE ABOVE WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, WHETHER EXPRESS, IMPLIED OR
STATUTORY, INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY, FITNESS
FOR A PARTICULAR PURPOSE, OR ANY WARRANTY ARISING OUT OF ANY PROPOSAL,
SPECIFICATION OR SAMPLE. ACCTON SHALL NOT BE LIABLE FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES. ACCTON NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO
ASSUME FOR IT ANY OTHER LIABILITY.
Copyright
Copyright © 1999 by Accton Technology Corporation. All rights reserved. All trademarks or brand names
mentioned herein are trademarks or registered trademarks of their respective companies.
International Headquarters USA Headquarters
No. 1 Creation Road III, 6 Hughes
Science-based Industrial Park Irvine, CA 92618
Hsinchu 300, Taiwan, R.O.C. Phone Numbers Phone: 886-3-5770-270 Sales: 800-926-9288
FAX: 886-3-5770-267 Support: 888-398-4101 or 949-707-4847
Internet: support@accton.com.tw RMA: 800-762-4968
FAX: 949-707-2460
EM4582-SX-SC
E0699-R01
150079-102
EM4582-SX-SC Module
Users Guide
The EM4582-SX-SC Slide-in Module
The EM4582-SX-SC slide-in module is
designed for use in various Accton switch
models. At present, suitable units include:
CheetahSwitch Workgroup-3514F (ES3514F)
CheetahSwitch Workgroup-3526F (ES3526F)
CheetahSwitch Workgroup-3526G (ES3526G)
Contact your distributor for advice on newly
released switches which may be designed for
use with these modules.
Caution: Do not install this module in any
other units.
The EM4582-SX-SC includes 1 1000BASE-SX
(SC-Type) port which can be used for a highspeed backbone or server connection. Detailed
information on configuring this module and
advice about Gigabit Ethernet configuration
rules can be found in the switchs user guide.
Safety Warning
Before installing or removing the EM4582-SX-SC,
first disconnect the switch from the main power
supply. For full safety instructions, please refer to
the user guide that accompanies the switch.
Warning: Optical Safety for Fiber Optic Modules
When using a fiber optic media
expansion module, never look at
the transmit laser while it is powered on. Also,
never look directly at the fiber TX port and fiber
cable ends when they are powered on.
Avertissment: Ports pour fibres optiques - sécurité
sur le plan optique
Ne regardez jamais le laser tant
qu'il est sous tension. Ne regardez jamais
directement le port TX (Transmission) à fibres
optiques et les embouts de câbles à fibres optiques
tant qu'ils sont sous tension.
Warnhinweis: Faseroptikanschlüsse - Optische
Sicherheit
Niemals ein Übertragungslaser
betrachten, während dieses eingeschaltet ist.
Niemals direkt auf den Faser-TX-Anschluß und auf
die Faserkabelenden schauen, während diese
eingeschaltet sind.
Handling the Module
Caution: The EM4582-SX-SC can easily be
damaged by electrostatic discharge.
To prevent electrostatic damage, observe the
following guidelines:
Do not remove the EM4582-SX-SC from its
packaging until you are ready to install it.
Do not touch any of the modules pins,
connectors or components.
Hold the module only by its edges or front
panel.
Wear an anti-static wristband connected to a
suitable earth ground whenever handling the
module.
Store or transport these modules only in
appropriate anti-static packaging.
Installing the EM4582-SX-SC
1 Ensure that the switch is disconnected from
the main power supply, and you are
wearing an anti-static wristband connected
to a suitable earth ground.
2 Place the unit on a flat surface. Using a
flathead screwdriver, remove the screws
from the cover plate of an empty slot on the
rear panel of the switch.
3 Keep the cover plate in a safe place.
If you remove the module, replace the
cover plate to prevent dust and debris from
entering the unit and to maintain proper air
flow.
4 Holding the module with the text on the
front panel upright, slide it into the unit,
ensuring that the edge connector is fully
engaged. Be sure the front panel of the
module is flush against the switch, and then
attach it to the unit with the retainer screws
attached to the face plate.
Making Fiber Optic Connections
1 Remove the cover from the fiber connector
on the module. Keep it in a safe place, and
place it back on the connector if you unplug
the fiber cable from the module.
2 Plug the fiber connector on the cable into
the fiber optic socket on the module.
3 Connect the other end of the cable to any
device that has a standard 1000BASE-SX
Gigabit Ethernet fiber interface. Maximum
length for Gigabit cable is listed below.
eziSrebiF htdiwdnaBrebiF htgneLmumixaM
norcim521/5.26mk/zHM061)tf227-7(m022-2
mk/zHM002)tf209-7(m572-2
norcim521/05mk/zHM004)tf1461-7(m005-2
mk/zHM005)tf5081-7(m055-2
Note: This module operates at 1Gbps, and
supports auto-negotiation for duplex mode
(half duplex or full duplex) and flow control.
Putting the Switch Online
1 Power up the switch.
2 Check the LED indicators on the switch to
ensure that the module is operating
correctly. Refer to the switchs user guide
for a description of the LED indications.
Troubleshooting
If you experience any problems with the
module, check the following items before
contacting your distributor:
Ensure the switch with the slide-in module is
powered up.
Ensure that the device attached to the
module is powered up and operating
correctly.
Ensure that the module is properly seated in
the slot.
Verify that the port is configured to match the
communication mode of the attached
device (1Gbps and half/full duplex mode).
Check all connectors on both ends of the
cables to be sure they are properly engaged.
When inserting fiber cable into an SC-type
port, be sure the plug clicks into place to
ensure that it is properly seated.
If you are using an SC-ST converter, try
switching the TX and RX connections.
Clean the cable plugs by wiping them gently
with a clean tissue or cotton ball moistened
with a little ethanol. Dirty fiber terminators on
the fiber optic cables will impair the quality of
the light transmitted through the cable.
Specifications
Ports 1 1000BASE-SX, SC type
Communication Mode Half duplex, full duplex,
auto-negotiation
Cable Type 50/125µm, 62.5/125µm MMF
Switching Method Store-and-forward
Filtering/Forwarding Full line speed
Queue Buffer 2 Mbytes
Power Compumption 2.4W maximum
Temperature 0-50°C (32-122°F) Std. Opr.
-40-70°C (-40-158°F) Storage
Humidity 5% to 95% (Non-condensing)
Standards IEEE 802.3z
ISO/lEC 8802-3
Certification CE Mark
Emissions FCC Class A, VCCI Class A,
CISPR Class A
Immunity IEC 1000-4-2/3/4/6
EMI Certification
FCC Class A (USA)
This equipment has been tested with a Class A
computing device and has been found to comply
with part 15 of FCC Rules. Operation in a
residential area may cause unacceptable
interference to radio and TV receptions requiring
the operator to take whatever steps are
necessary to correct the interference.
Class A (Canada Department of Communications)
This digital apparatus does not exceed the
Class A limits for radio noise emissions from
digital apparatus as set out in the interferencecausing equipment standard entitled "Digital
Apparatus", ICES-003 of the Department of
Communications.
Cet appareil numérique respecte les limites de
bruits radioélectriques applicables aux
appareils numériques de Classe A prescrites
dans la norme sur le matériel brouilleur:
"Appareils Numérques", NMB-003 édictée par
le ministère des Communications.