Terxon SX Starter Set
Art. no. AZ4298
Ideal starter set for wired alarm systems
•
Includes control panel, siren, motion detector, 2 opening detectors and 50 m alarm cable
•
Can be flexibly extended at any time
•
With 8 freely configurable zones
•
Page 1 of 4
Terxon Alarm System SX as a starter kitThe Terxon SX starter set contains all components for effective protection. If
required, the system can be expanded at any time. The Terxon SX starter set offers all the advantages of the
Terxon SX. 8 freely programmable zones are available for installation.Effective sabotage protectionThe ninth zone
is the sabotage zone. Only NC detectors can be connected. The type of wiring can be freely selected. The indoor
siren is included in the package and has its own reserved zone on the main board.Convenient
activation/deactivation via codeIn addition to the Alarm Panel, the heart of the system, a control Panel for
activating and deactivating the Alarm Panel as well as a motion detector and 2 magnetic contacts are included in
this kit.
Technical Data:
VdS class none
Technical alterations reserved. Misprints and errors excepted. Copyright. © ABUS 08/2020
Terxon SX Starter Set
Art. no. AZ4298
Terxon SX Alarm Control Panel
Dimensions (WxHxD) 240x240x85 mm
Connections 230 V screw terminal, 13.8
V screw terminal,
loudspeaker, zone-screw
terminal, 11 x switching
outputs
Number of control panels 4
Number of users 16
Number of wired zones 8
Number of events 250
Number of tamper zones 1
Display Two-line LCD
alphanumerical display
Battery type 12V DC, 7.0 Ah lead
rechargeable battery
Width 240 mm
Event log Yes
Extensible (hybrid) No
Remote configuration No
Housing material Alarm centre: Metal,
control unit: ABS
Height 240 mm
Integrated siren Yes
Communication/alarming Only compatible via
external dialer: AZ6301,
AZWG10020
Length 85 mm
Max. number of control
panels
Max. operating
temperature
Max. battery charging time 24 h
Max. humidity 75 %
Max. run time on backup
power
4
40 °C
12 h
Page 2 of 4
Min. operating
temperature
Net weight 2,45 kg
Backup power supply Yes
Configuration (1) Via control panel
Tamper lines 2
Tamper monitoring Yes
Switching outputs 3 x 500 mA transistors, 8 x
Security level 2
Fuse 230 V / 250 mA; 12 V: 1 A
Voltage monitoring Yes
AC voltage supply 230 V
OSD language 11 selectable languages
Power consumption 200 mA
Partitions/surveillance
partitions
Environmental class II
Certifications INCERT
Zone closure NC, DEOL
-10 °C
50 mA transistors, freely
programmable
fast; battery: 2 A fast
4
Technical alterations reserved. Misprints and errors excepted. Copyright. © ABUS 08/2020