Terxon LX Hybrid Alarm Control Panel
Art. no. AZ4200
Hybrid system, scalable up to 256 wireless/wired zones
•
8 partitions enable independent security for multiple building sections
•
Programming with LCD key pads or software
•
Integrated analogue dialler for transmitting digital monitoring centre protocols
•
Connect up to 128 control panels
•
High security because of tampered control panel, key pad, and detector
•
Page 1 of 2
The Terxon LX Hybrid Alarm Control Panel is the alarm system for commercial properties and larger building
complexes. You can both integrate wired detectors and all Secvest 2WAY wireless components, thus extending the
system to a hybrid system. The motherboard of the Terxon LX provides 8 freely programmable zones for 8 wired
detectors. Each zone has its own tampering zone. Up to 128 control units and 32 extension modules can be
connected via bus wiring, for 8 wireless zones or 8 wired zones. This way, you can extend the Terxon LX to 264
zones at any time. Additionally, the system can be split into 8 separately controlled sub-sections. The 23
switching outputs of the motherboard can be extended to a total of 93 outputs. If desired you can automatically
switch the external devices that you have attached to these outputs (according to a specified schedule).
Altogether, you can create 99 users in the system with 12 different authorization levels. The scope of delivery
already includes an LCD control unit, allowing the system to be programmed or activated and deactivated. The
system can also be programmed via PC (USB or RS232) or downloader software. Via the analogue telephone
dialling unit (AWUG) already integrated in the system, you can notify an emergency call center in the event of an
alarm. Thus, the Terxon LX hybrid alarm panel provides continuous all-round protection to the owner.
Technical alterations reserved. Misprints and errors excepted. Copyright. © ABUS 02/2020

Terxon LX Hybrid Alarm Control Panel
Art. no. AZ4200
Technical Data:
Dimensions (WxHxD) 390x310x90 mm
Connections 230 V screw terminal, 13.8
V screw terminal,
loudspeaker, zone-screw
terminal, 23 x switching
outputs, RS-232, PSTN, USB,
2 x bus
Number of control panels 128
Number of users 99
Number of wired zones 8
Number of events 2.000
Number of tamper zones 8
Display Two-line LCD
alphanumerical display
Battery type 12 V DC, 7.0 Ah or 17 Ah
lead battery
Width 390 mm
Event log Yes
Extensible (hybrid) Yes
Remote configuration Yes
Housing material Alarm centre: Metal,
control unit: ABS
Height 310 mm
Integrated siren No
Communication/alarming Integrated analog dialer
for transferring digital
monitoring station
protocols
Length 90 mm
Max. number of control
128
panels
Max. operating
40 °C
temperature
Max. battery charging time 24 h
Max. humidity 75 %
Max. run time on backup
15 h
power
Page 2 of 2
Min. operating
temperature
Net weight 5 kg
Backup power supply Yes
Configuration (1) Via control panel, per
Protocols ARC: fast format, contact
Tamper lines 9
Tamper monitoring Yes
Switching outputs 1 x siren, 1 x flash, 3 x 500
Security level 2
Fuse 230 V / 250 mA; 12 V: 1 A
Voltage monitoring Yes
AC voltage supply 230 V
OSD language 11 selectable languages
Power consumption 200 mA
Partitions/surveillance
partitions
Environmental class II
Zone closure NC / DEOL
-10 °C
software, per modem
ID, SIA
mA transistors, 2 x 1000 mA
relays, 16 x 50 mA
transistors
fast; rechargeable battery 2
A fast
8
Powered by TCPDF (www.tcpdf.org)
Technical alterations reserved. Misprints and errors excepted. Copyright. © ABUS 02/2020