ABUS AZ4200 Service Manual

Terxon LX Hybrid Alarm Control Panel
Art. no. AZ4200
Hybrid system, scalable up to 256 wireless/wired zones
• 8 partitions enable independent security for multiple building sections
• Programming with LCD key pads or software
• Integrated analogue dialler for transmitting digital monitoring centre protocols
• Connect up to 128 control panels
• High security because of tampered control panel, key pad, and detector
Page 1 of 2
The Terxon LX Hybrid Alarm Control Panel is the alarm system for commercial properties and larger building complexes. You can both integrate wired detectors and all Secvest 2WAY wireless components, thus extending the system to a hybrid system. The motherboard of the Terxon LX provides 8 freely programmable zones for 8 wired detectors. Each zone has its own tampering zone. Up to 128 control units and 32 extension modules can be connected via bus wiring, for 8 wireless zones or 8 wired zones. This way, you can extend the Terxon LX to 264 zones at any time. Additionally, the system can be split into 8 separately controlled sub-sections. The 23 switching outputs of the motherboard can be extended to a total of 93 outputs. If desired you can automatically switch the external devices that you have attached to these outputs (according to a specified schedule). Altogether, you can create 99 users in the system with 12 different authorization levels. The scope of delivery already includes an LCD control unit, allowing the system to be programmed or activated and deactivated. The system can also be programmed via PC (USB or RS232) or downloader software. Via the analogue telephone dialling unit (AWUG) already integrated in the system, you can notify an emergency call center in the event of an alarm. Thus, the Terxon LX hybrid alarm panel provides continuous all-round protection to the owner.
Technical alterations reserved. Misprints and errors excepted. Copyright. © ABUS 02/2020
Terxon LX Hybrid Alarm Control Panel
Art. no. AZ4200
Technical Data:
Dimensions (WxHxD) 390x310x90 mm Connections 230 V screw terminal, 13.8
V screw terminal, loudspeaker, zone-screw terminal, 23 x switching outputs, RS-232, PSTN, USB,
2 x bus Number of control panels 128 Number of users 99 Number of wired zones 8 Number of events 2.000 Number of tamper zones 8 Display Two-line LCD
alphanumerical display Battery type 12 V DC, 7.0 Ah or 17 Ah
lead battery Width 390 mm Event log Yes Extensible (hybrid) Yes Remote configuration Yes Housing material Alarm centre: Metal,
control unit: ABS Height 310 mm Integrated siren No Communication/alarming Integrated analog dialer
for transferring digital
monitoring station
protocols Length 90 mm Max. number of control
128 panels Max. operating
40 °C temperature Max. battery charging time 24 h Max. humidity 75 % Max. run time on backup
15 h power
Page 2 of 2
Min. operating temperature Net weight 5 kg Backup power supply Yes Configuration (1) Via control panel, per
Protocols ARC: fast format, contact
Tamper lines 9 Tamper monitoring Yes Switching outputs 1 x siren, 1 x flash, 3 x 500
Security level 2 Fuse 230 V / 250 mA; 12 V: 1 A
Voltage monitoring Yes AC voltage supply 230 V OSD language 11 selectable languages Power consumption 200 mA Partitions/surveillance partitions Environmental class II Zone closure NC / DEOL
-10 °C
software, per modem
ID, SIA
mA transistors, 2 x 1000 mA relays, 16 x 50 mA transistors
fast; rechargeable battery 2 A fast
8
Powered by TCPDF (www.tcpdf.org)
Technical alterations reserved. Misprints and errors excepted. Copyright. © ABUS 02/2020