Terxon MX Alarm Control Panel
Art. no. AZ4100
Expandable as a hybrid system up to 32 zones
•
4 partitions enable independent security for multiple building sections
•
Programming with LCD key pad or software
•
Integrated analogue dialler for transmitting digital monitoring centre protocols
•
High security because of tampered panel, control panels and detectors
•
Page 1 of 2
The Terxon MX Alarm Control Panel is the burglary alarm system made by ABUS Security-Center. This alarm device
allows you to integrate all wired detectors and all wireless components of the Secvest 2WAY, thus extending the
system into a hybrid system. Up to 32 alarm zones guarantee complete all-over protection. From private homes to
larger building complexes: The Terxon MX provides many options for securing your property. The motherboard
offers 8 freely programmable zones for 8 wired detectors. Zone 9 is configured as tamper zone. Extension
modules can be connected via 4-wire bus cables - for 8 wireless zones or 8 wired zones. The motherboard of the
Terxon M provides 1 transistor output and 2 relay switching outputs, which are activated in the case of specific
events (alarm, fire, or robbery). If desired, you can incorporate an additional relay board with 8 outputs in the
Terxon MX. The scope of delivery already includes an LCD control unit, which allows the system to be conveniently
programmed or activated and deactivated. Three additional control units can be connected. The system can also
be programmed via PC. You can configure the Terxon MX as a single-user system or as a partitioned system. It has
an integrated telephone dialling unit (AWUG) and it is both VSÖ and INCERT certified.
Technical alterations reserved. Misprints and errors excepted. Copyright. © ABUS 02/2020

Terxon MX Alarm Control Panel
Art. no. AZ4100
Technical Data:
Dimensions (WxHxD) 390x310x90 mm
Connections 230 V screw terminal, 13.8
V screw terminal,
loudspeaker, zone-screw
terminal, 11 x switching
outputs, RS-232, PSTN
Number of control panels 4
Number of users 16
Number of wired zones 8
Number of events 250
Number of tamper zones 1
Display Two-line LCD
alphanumerical display
Battery type 12V DC, 7.0 Ah lead
rechargeable battery
Width 390 mm
Event log Yes
Extensible (hybrid) Yes
Remote configuration Yes
Housing material Alarm centre: Metal,
control unit: ABS
Height 310 mm
Integrated siren No
Communication/alarming Integrated analog dialer
for transferring digital
monitoring station
protocols
Length 90 mm
Max. number of control
4
panels
Max. operating
40 °C
temperature
Max. battery charging time 24 h
Max. humidity 75 %
Max. run time on backup
12 h
power
Page 2 of 2
Min. operating
temperature
Net weight 5 kg
Backup power supply Yes
Configuration (1) Via control panel, per
Protocols NSL: Fast Format, Contact
Tamper lines 2
Tamper monitoring Yes
Switching outputs 1 x 500 mA transistors, 2 x
Security level 2
Fuse 230 V / 250 mA; 12 V: 1 A
Voltage monitoring Yes
AC voltage supply 230 V
OSD language 11 selectable languages
Power consumption 200 mA
Partitions/surveillance
partitions
Environmental class II
Certifications INCERT, VSÖ, REQ
Zone closure NC, DEOL
-10 °C
software, per modem
ID, SIA
1000 mA relays, 8 x 50 mA
transistors, freely
programmable
fast; battery: 2 A fast
4
Powered by TCPDF (www.tcpdf.org)