AbsolutAire THC User Manual

FEATURES
Page 1 of 3Airotronics - Delay On Make - THC
CUBE–SOLID STATE
Timing Mode
Application of input voltage to the timer starts the time delay. At the end of the delay period, the load is energized. To reset, remove the input voltage to the timer.
THC Timers
THC timers are solid-state output units with digital timing. The TH comes in a 2" square case.
Ease of installation and hook-up is a primary design benefit. All models with integral time adjustment knob or factory-fixed time require only two connections. They may be wired in­line just like a single pole switch. Units with external time adjustment have two additional terminals for the resistor or potentiometer.
? Digital timing, solid-state output
?
1 Amp current load handling
? 10 Amps single-cycle surge handling ? 4 Overlapping AC voltage ranges
(from 19 to 277 volts)
? 1% Repeat accuracy ? Virtually unlimited time ranges
?
Factory-fixed or variable-timing adjustment
? Totally encapsulated for protection
from harsh environments
BASIC WIRING AND DIMENSIONS
? O-ring sealed exposed controls
?
Single screw mounting through center mounting hole
? Standard 6.35mm (.250") quick
connect blade terminals
? 100% Operational testing before
shipping
?
1/18/2007http://www.airotronics.com/delayonmake/thc.htm
SPECIFICATIONS
SELECTION PROCEDURE
Repeat Accuracy:: ±0.1%under fixed conditions
Time Ranges: 0.1 sec. to 24 hours (1 sec., 10 sec.,
100 sec., and 1000 secs. are standard) Special time ranges available on request.
Reset/Recycle Time: 100 milliseconds
Tolerances: Fixed: ±10% of normal time (optional: -
±5%,±1%) Variable: -0%, +15% Limit:-10% at minimum time
Protection:
?
Polarity Protection: All DC units have reverse polarity protection
? Transient Protection: 18
joules
? Dielectric Strength: 1800V
RMS 60 Hz
Power Requirement: .25 watts max.
Page 2 of 3Airotronics - Delay On Make - THC
Recycle Effect: None
Temperature Ranges:
? Storage: -40°C to +85°C
?
Operating: -25°C to +85°C
Life Expectancy: No predictable failure if used within operating parameters
Mode of Operation
Delay On Make
Series
THC
Input Voltage
1 40-140 VAC 50/60 Hz
2 90-260 VAC 50/60 Hz
3 19-48 VAC/DC 50/60 Hz
8 90-277 VDC 50/60 Hz
Time Ranges
VARIABLE TIME PERIODS 0001 .1 to 1 sec.
0010 .1 to 10 sec. 0100 1 to 100 sec. 1000 10 to 1000 sec.
Any range up to 24 hours avaialble on special order
FIXED TIME PERIODS
Specify time in seconds(S) or hours(H) Examples: 400S is 400 secs 05H5 is 5.5 hours
Weight: 3 oz. (85g) maximum
Load Current: 1 amp continuus, 10
amps single-cycle surge
Time Cycle Interrupt: Resets timer to original state (input Voltage
Break)
Time Adjustment Method
A. Variable, integral,
knob on timer.
B. Variable, external
remote potentiometer timer.
C. Fixed, internal,
factory set
D. External, remote
resistors
Airotronics
2747 Route 20 East
Cazenovia, New York 13035
Tel: 315-655-8476 Fax: 315-655-3862
1/18/2007http://www.airotronics.com/delayonmake/thc.htm