BASIC WIRING AND DIMENSIONS
Page 1 of 3Airotronics - Delay On Make - TGC CUBE
Cube Relay
TGC Timers
TGC series Cube Relay Delay on
Make timers are a unique
combination of digital CMOS timing
circuitry with a relay output in a
compact 2" x 2" configuration. For
users of solid-state timers, these
units provide the same functional
performance as plug-in relay timers,
but at significant cost savings.
Timing Mode
Application of input voltage to the timer starts the
time delay. At the end of the delay period, the
load is energized. To reset, remove the input
voltage to the timer.
? High current carrying capacity up to 20
amps
?
Transient protected
? 100% Load isolation
?
No leakage in N.O. position
?
No heat sinking required
? Available in any time delay period required
? Digital CMOS timing
? No minimum load required
?
Totally encapsulated for
protection from harsh
environments
? 100% Operational testing
before shipping
?
1/18/2007http://www.airotronics.com/delayonmake/tgc_cube.htm
SPECIFICATIONS
Input Voltage:
?
VDC: 12, 24 or 48
? VAC: 24, 48, 120 or 230, 50/60 Hz
Time Delay:
?
Timing Mode: Delay On Make
? Type: Digital CMOS
? Time Range: 0.2 seconds to 24 hours
?
Time Adjustments: Factory-fixed time
period; variable, with adjustments on
timer, or terminals for external resistor
or potentiometer
Repeatability: ±0.5%
Setting Accuracy:
? Fixed time period: 10% of nominal
time.
? Variable time range: +15% -5% max.
time, -10% min. time
Relay Life Expectancy:
?
Mechanical: 20 million operations
?
Electrical: 100,000 operations
? Contact Material: Silver nickel, gold
plated, or silver cadmium oxide
Protection:
? Polarity Protection: All DC units have
reverse polarity protection
? Transient Protection: 18 joules
?
Dielectric Strength: 1800V RMS 60 Hz
Temperature Ranges:
? Storage: -25° C to +85° C
? Operating: -40° C to +85° C
Page 2 of 3Airotronics - Delay On Make - TGC CUBE
Reset/Recycle Time: 25 milliseconds
Initiate Time: 6 milliseconds or less
Relay Output:
Form:
? Standard – SPST N.O.
?
Optional – SPST N.C., SPDT
SELECTION PROCEDURE
Mode of
Operation
Series
Input
Voltage
1.
2.
3. 24 VAC
Physical Data:
?
? Connection & Termination: 0.25" quick
Time Ranges
VARIABLE TIME PERIODS
0001 0.5 to 1 sec.
Mounting: Surface with one #8 screw
connects
Time
Adjustment
A.
integral,
knob on
Relay
Output
Form
1.
2.
Options
H Heavy
duty, 10
amps (6
1/18/2007http://www.airotronics.com/delayonmake/tgc_cube.htm