ABBYY FlexiCapture Administrator’s Guide

ABBYY FlexiCapture
System Administrator’s Guide
© 2014 ABBYY Production LLC. All rights reserved.
2
marks or trademarks of ABBYY Software Ltd.
© 1984-2011 Adobe Systems Incorporated and its licensors. All rights reserved. Protected by U.S. Patents 5,929,866; 5,943,063; 6,289,364; 6,563,502; 6,639,593; 6,754,382; Patents Pend­ing. Adobe, the Adobe logo, Acrobat, the Adobe PDF logo, Distiller and Reader are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States and/or other countries.
Portions of this computer program are copyright © 2008 Celartem, Inc. All rights reserved. Portions of this computer program are copyright © 2011 Caminova, Inc. All rights reserved. Portions of this computer program are copyright © 2013 Cuminas, Inc. All rights reserved. DjVu is protected by U.S. Patent No. 6,058,214. Foreign Patents Pending. Powered by AT&T Labs Technology.
PixTools © 1994-2007 EMC Corporation. All rights reserved.
WIBU, CodeMeter, SmartShelter, SmartBind are registered trademarks of Wibu-Systems.
Portions of this software are copyright © 2012 University of New South Wales. All rights reserved. © 2001-2006 Michael David Adams
© 1999-2000 Image Power, Inc. © 1999-2000 The University of British Columbia
This software is based in part on the work of the Independent JPEG Group.
© 1991-2013 Unicode, Inc. All rights reserved. The Unicode Word Mark and the Unicode Logo are trademarks of Unicode, Inc.
Portions of this software are copyright © 1996-2002, 2006 The FreeType Project (www.freetype.org). All rights reserved.
© ParaType, 2003
EMC2, EMC, Captiva, ISIS and PixTools are registered trademarks, and QuickScan is a trademark of EMC Corporation.
Kodak is a registered trademark of Eastman Kodak Company.
.NET, Access, Active Directory, ActiveX, Aero, Excel, Hyper-V, InfoPath, Internet Explorer, JScript, Microsoft, Office, Outlook, PowerPoint, SharePoint, Silverlight, SQL Azure, SQL Server, Visual Basic, Visual C++, Vis­ual C#, Visual Studio, Windows, Windows Azure, Windows Power Shell, Windows Server, Windows Vista, Word are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
Oracle and Java are registered trademarks of Oracle and/or its affiliates.
All other trademarks are the property of their respective owners.
© 2014 ABBYY Production LLC. All rights reserved.
3
Table of Contents
Installing ABBYY FlexiCapture ............................................................................................................................................... 5
Standalone Installation ................................................................................................................................................................................................................................5
System Requirements Installation methods Interaction of the system components Manual (interactive) installation Command line installation
Distributed Installation ............................................................................................................................................................................................................................... 7
System Requirements General information Preparing the Application Server for installation on Windows 2012 Preparing the Application Server for installation on Windows Server 2008 R2 Installing the servers External components required for the correct operation of the system System components in IIS and their configuration Database server Interaction of the system components
.....................................................................................................................................................................................................5
...........................................................................................................................................................................................................5
.............................................................................................................................................................5
..............................................................................................................................................................................5
........................................................................................................................................................................................... 6
.................................................................................................................................................................................................... 7
.......................................................................................................................................................................................................... 15
................................................................................. 15
.................................................... 16
....................................................................................................................................................................................................... 19
........................................................................ 20
............................................................................................................................ 21
................................................................................................................................................................................................................. 34
...........................................................................................................................................................35
Installing the stations
Using Active Directory .............................................................................................................................................................................................................................. 37
Example: Deploying ABBYY FlexiCapture using Active Directory
Using SMS .................................................................................................................................................................................................................................................... 40
Example: Deploying ABBYY FlexiCapture using Microsoft SMS
Installing Remote Stations ........................................................................................................................................................................................................................ 44
Upgrading from ABBYY FlexiCapture 9.0 and 10 ............................................................................................................................................................................... 45
Updating projects created in a standalone edition of ABBYY FlexiCapture (*.fcproj) Updating projects and databases created in a distributed edition of ABBYY FlexiCapture Using ABBYY FlexiLayout Studio 9.0 or 10 projects (*.fsp) Using FlexiLayouts (*.afl) created in ABBYY FlexiLayout 9.0 or 10
......................................................................................................................................................................................................35
.................................................................................... 37
........................................................................................ 41
.................................... 45
..................... 45
.................................................................................................... 47
................................................................................ 47
Managing Your Licenses ............................................................................................................................................................ 48
Overview ....................................................................................................................................................................................................................................................... 48
ABBYY FlexiCapture 11 License Manager .............................................................................................................................................................................................. 48
License properties ....................................................................................................................................................................................................................................... 48
License statuses ........................................................................................................................................................................................................................................... 49
© 2014 ABBYY Production LLC. All rights reserved.
4
Buttons ......................................................................................................................................................................................................................................................... 49
Activating a license ..................................................................................................................................................................................................................................... 49
How is activation carried out?
Connecting stations to the Licensing Server ......................................................................................................................................................................................... 50
............................................................................................................................................................................... 49
Setting Up ABBYY FlexiCapture Distributed Installation ........................................................................ 51
Quick setup of ABBYY FlexiCapture for demonstration installations .............................................................................................................................................. 51
Detailed setup of ABBYY FlexiCapture ................................................................................................................................................................................................... 51
How to choose the user authentication type Creating a database Connecting to an existing database Uploading a project to the server Creating new users Setting up user roles and access rights Configuring the Processing Server
Oracle database settings ............................................................................................................................................................................................................................ 61
Web stations’ settings ................................................................................................................................................................................................................................ 63
Security settings in ABBYY FlexiCapture Distributed ........................................................................................................................................................................ 64
........................................................................................................................................................................................................52
................................................................................................................................................................ 55
....................................................................................................................................................................... 56
.......................................................................................................................................................................................................... 56
.................................................................................................................................................................. 59
............................................................................................................................................ 51
...................................................................................................................................................... 59
Recommendations for setting up ABBYY FlexiCapture ..................................................................................................................................................................... 65
General recommendation Using performance counters
.......................................................................................................................................................................................... 65
.................................................................................................................................................................................. 68
Logging .......................................................................................................................................................................................................... 74
Administration and Monitoring Console logs...................................................................................................................................................................................... 74
Task processing logs on the Processing Servers.................................................................................................................................................................................... 74
OS event logs on the servers ..................................................................................................................................................................................................................... 74
Working with Clusters ................................................................................................................................................................... 75
Setting Up the Processing Server ............................................................................................................................................................................................................. 75
Deploying the Processing Server on a Failover Cluster
Setting Up the Licensing Server ............................................................................................................................................................................................................... 94
Setting Up the Application Server (and clustering the Administration and Monitoring Console and Web Stations) ......................................................... 94
Setting Up an NLB Cluster for the Application Server
.............................................................................................................. 75
................................................................................................................... 94
Technical Support .............................................................................................................................................................................. 97
© 2014 ABBYY Production LLC. All rights reserved.
5
Licensing Server
TCP/IP 10041
FlexiLayout
Studio
FormDesigner
Operator Station
Administrator
Station
Installing ABBYY FlexiCapture
Before purchasing the product, analyze your document processing needs and select either the local or the distributed version.
If you plan to process moderate amounts of documents (approximately 5,000 pages per day), employ one or two op­erators for the job, and do not require any sophisticated batch routing, then Standalone Installation is the best choice.
If you plan to automate data capture and processing, require sophisticated batch routing based on document or batch types, and need a scalable pool of centrally administered workstations, then select Distributed Installation.
Note: When installing the program under Windows Vista, Windows Server 2008 or newer operations systems, the UAC should be disabled before installation or the native administrator account must be used.
Important! The distributed and local versions cannot be installed on the same computer.
Standalone Installation
System Requirements
PC with Intel® Pentium®/Celeron®/Core™2 Duo/Quad/Xeon®/Core™ i5/Core™ i7, AMD
K6/Turion™/Athlon™/Duron™/Sempron™ with a minimum clock speed of 2 GHz
Operating system: Windows XP SP3, Windows Vista SP2, Windows 7 SP1, Windows 8/8.1, Windows Server
2003 SP2, Windows Server 2008 SP2 + Desktop Experience, Windows Server 2008 R2 SP1 + Desktop Ex­perience, Windows Server 2012 + Desktop Experience, Windows Server 2012 R2 + Desktop Experience (for localized interfaces, corresponding language support is required)
Memory: 512 MB for each CPU core, but no less than 1 GB  Hard disk space: 1.5 GB (including 1 GB for installation)  Scanner supporting TWAIN, WIA or ISIS  Video card and display with a resolution of 1024×768 Microsoft .NET Framework 3.5 SP1
Installation methods
The following installation methods are available to install the standalone version of ABBYY FlexiCapture:
manually (interactive installation) from the command line
Interaction of the system components
The following figure displays the system component interaction for standalone installation:
If you have one license and several operator stations, then for connecting operator stations to the Licensing Server, the 10041 port has to be opened manually in Firewall settings.
Manual (interactive) installation
To install the standalone version of ABBYY FlexiCapture:
© 2014 ABBYY Production LLC. All rights reserved.
6
1. In the Autorun menu, select Standalone Installation (you can run the autorun.exe file manually).
2. Select a setup language. The setup program will compare the locale of your system and the selected lan-
guage. If the languages are incompatible, a warning message is displayed.
3. Next, the setup program checks the version of your operating system and the availability of the administrative permissions. If the version of the operating system is not supported by the program or you do not have the administrative permissions, a warning message is displayed and the setup program is terminated.
4. If all the checks are passed successfully, the end-user license agreement will be displayed. Read the license agreement carefully and if you agree with the terms of the agreement, select the corresponding option and click Next.
5. A dialog box will open prompting you to enter some information about yourself. Enter the required information and continue with the installation.
6. In the next dialog box, select one of the available installation modes:
Administrator Station – The setup program installs the Administrator Station, FormDesigner, and
FlexiLayout Studio.
Operator Station – The setup program installs only the Operator Station. (The Administrator Station,
FormDesigner and FlexiLayout Studio will not be installed).
Administrator and Operator Stations – The setup program installs the Administrator Station, the Oper-
ator Station, FormDesigner and FlexiLayout Studio. By default this configuration is installed.
7. Next, select a destination folder. By default, the program is installed to %systemdrive%\Program Files\ABBYY FlexiCapture 11. If there is not enough space on the selected hard disk, a window is displayed
showing your hard disks, the available free space, and the space required by the installation. Select a disk with sufficient free space and continue with the installation.
8. The program files will be copied onto your computer. Once the installation is finished, the setup program will display a message saying that the application has been successfully installed.
9. License Manager will be launched automatically so that you can activate your serial number. See the “Man- aging Licenses” section for details.
Note: For information about configuring multiple workstations to work with a single license server, see Connecting
stations to the Licensing Server.”
Command line installation
In the default configuration, all recognition languages are installed on the local computer and the interface language is selected automatically based on the regional settings of the computer on which the program is installed. By default, the Administrator and Operator Stations installation mode will be selected (see above).
Run the setup.exe file located in the administrative installation folder using the command line options described be­low.
Advertise installation
For advertise installation, type Setup.exe /j The ABBYY FlexiCapture icon will appear in the Start menu. Clicking this icon automatically installs the program in
default configuration.
Silent installation
In the case of silent installation, no setup dialog boxes are displayed and the program is installed in default configura­tion.
Setup.exe /qn Change “/qn” to “/qb” if you want an installation progress bar to be displayed. No other dialog boxes will be displayed.
Additional command line options
/L<language code> disables auto selection of the interface language and installs the program with the interface lan­guage you specified.
The following language code values are available: 1033 English 1049 Russian
© 2014 ABBYY Production LLC. All rights reserved.
7
/V <command line> passes the specified command line directly to msiexec.exe. The <command line> string can be replaced with the following commands:
INSTALLDIR="<destination>" – the path to the folder where ABBYY FlexiCapture is to be installed. SETUPTYPE_CMD="<install mode>" – available installation modes.
The following modes are available: Full – Administrator and Operator Stations Admin – Administrator Station Operator – Operator Station Note: See the previous section for a description of the available installation modes. Example: Setup.exe /qn /L1049 /v INSTALLDIR="D:\FC11" SETUPTYPE_CMD=Full As a result, the Administrator and Operator Stations will be installed into D:\FC11, and Russian will be used the lan-
guage of the interface.
Removing ABBYY FlexiCapture in silent mode
msiexec /x {uninstall registry key}. The location of the uninstall registry key:
HKEY_LOCAL_MACHINE\Software\Microsoft\Windows\CurrentVersion\Uninstall (the Product ID is in the name of the subkey with the product name in its values). You can also determine the Product ID by executing the following command in the command line: "wmic product where "Name like '%FlexiCapture%'" get Name, Version,
IdentifyingNumber".
Distributed Installation
System Requirements
Servers Application Server
PC with Intel® Pentium®/Celeron®/Core™2 Duo/Quad/Xeon®/Core™ i3/Core™ i5/Core™ i7, AMD
K6/Turion™/Athlon™/Duron™/Sempron™ with a minimum clock speed of 2 GHz. The use of processor
which has 2 or more cores is recommended for Application Server.
Operating system: Windows Server 2008 SP2 + Desktop Experience, Windows Server 2008 R2 SP1 + Desk-
top Experience, Windows Server 2012 + Desktop Experience, Windows Server 2012 R2 + Desktop Experi­ence.
Memory: no less than 2 GB for Application Server and 4 GB for MS SQL Server  Hard disk space: 100 MB for installation, 2 GB for SQL Server database. Additional space is required for the
file storage.
The computer where the server is installed must be connected to your domain  Internet Information Server 7 or higher.  Microsoft .NET Framework 4.0 (4.5 if running under Windows Server 2012)  Microsoft SQL Server 2005 SP2, 2008 SP1, 2008R2 SP2, 2012 SP1, 2014
Note: Microsoft Azure SQL is not supported.
Oracle 10g, 11g or 12c
Administration and Monitoring Console
Video card and display with a resolution of 1024×768 Internet Information Server 7 or higher.  Microsoft .NET Framework 4.0 (4.5 if running under Windows Server 2012)  Crystal Reports for Visual Studio 2010 (Version 13, 13.0.11.1467 is recommended), Crystal Reports
2008 (Version 12), Crystal Reports for Visual Studio 2008 (Version 10.5)
Internet Explorer 7, 8, 9, 10 or 11.
© 2014 ABBYY Production LLC. All rights reserved.
8
Note. To insure that Internet Explorer 11 works correctly, install .NET Framework 4.5 on the com­puter with the Application Server or add the address of an application server to the list of websites that are opened in compatibility mode.
FlexiCapture Authentication Module
Internet Information Server 7 or later  Microsoft .NET Framework 4.0 (4.5 if running under Windows Server 2012)
For operation of Web Module for login and registration one of the following web browsers is required: Internet Explorer 7, 8, 9, 10 or 11. Browser security settings: Internet Explorer medium-high protec-
tion level. If high protection level is used, the following option must be specified explicitly:
Note. To insure that Internet Explorer 11 works correctly, install .NET Framework 4.5 on the com­puter with the Application Server or add the address of an application server to the list of websites that are opened in compatibility mode.
Note. The Metro-style version of Internet Explorer 10 that comes with Windows 8 is not supported. Note. Internet Explorer 64-bit is only supported under Windows 7/2008+ if Silverlight 5 is installed.
Mozilla Firefox 14 or later (32-bit). Security settings for Mozilla Firefox:
Google Chrome 20 or later (32-bit). Security settings for Google Chrome:
Processing Server
Active scripting = Enable
Java scripting = Enable
JavaScript = Allow all sites
PC with Intel® Pentium®/Celeron®/Core™2 Duo/Quad/Xeon®/Core™ i3/Core™ i5/Core™ i7, AMD
K6/Turion™/Athlon™/Duron™/Sempron™ with a minimum clock speed of 2 GHz.
Operating system: Windows Server 2008 SP2 + Desktop Experience, Windows Server 2008 R2 SP1 + Desk-
top Experience, Windows Server 2012 + Desktop Experience, Windows Server 2012 R2 + Desktop Experi­ence.
Memory: no less than 2 GB  Hard disk space: 100 MB for installation  Video card and display with a resolution of 1024×768 The computer where the server is installed must be connected to your domain
Licensing Server
PC with Intel® Pentium®/Celeron®/Core™2 Duo/Quad/Xeon®/Core™ i3/Core™ i5/Core™ i7, AMD
K6/Turion™/Athlon™/Duron™/Sempron™ with a minimum clock speed of 2 GHz.
Operating system: Windows Server 2008 SP2 + Desktop Experience, Windows Server 2008 R2 SP1 + Desk-
top Experience, Windows Server 2012 + Desktop Experience, Windows Server 2012 R2 + Desktop Experi­ence.
Memory: no less than 2 GB  Hard disk space: 100 MB for installation  The computer where the server is installed must be connected to your domain
Stations Project Setup Station
PC with Intel® Pentium®/Celeron®/Core™2 Duo/Quad/Xeon®/Core™ i3/Core™ i5/Core™ i7, AMD
K6/Turion™/Athlon™/Duron™/Sempron™ with a minimum clock speed of 2 GHz
Operating system: Windows XP SP3, Windows Vista SP2, Windows 7 SP1, Windows 8/8.1, Windows Server
2003 SP2, Windows Server 2008 SP2 + Desktop Experience, Windows Server 2008 R2 SP1+ Desktop Ex­perience, Windows Server 2012 + Desktop Experience, Windows Server 2012 R2 + Desktop Experience (for localized interfaces, corresponding language support is required)
Memory: 512 MB for each CPU core, but no less than 1 GB  Hard disk space: 1.5 GB (including 1 GB for installation)
© 2014 ABBYY Production LLC. All rights reserved.
9
Scanner supporting TWAIN, WIA or ISIS  Video card and display with a resolution of 1024×768 The computer where the station is installed must be connected to your domain  Microsoft .NET Framework 3.5 SP1
Processing Station
PC with Intel® Pentium®/Celeron®/Core™2 Duo/Quad/Xeon®/Core™ i3/Core™ i5/Core™ i7, AMD
K6/Turion™/Athlon™/Duron™/Sempron™ with a minimum clock speed of 2 GHz.
Operating system: Windows XP SP3, Windows Vista SP2, Windows 7 SP1, Windows 8/8.1, Windows Server
2003 SP2, Windows Server 2008 SP2 + Desktop Experience, Windows Server 2008 R2 SP1 + Desktop Ex­perience, Windows Server 2012 + Desktop Experience, Windows Server 2012 R2 + Desktop Experience (for localized interfaces, corresponding language support is required)
Memory: 512 MB for each CPU core, but no less than 1 GB  Hard disk space: 1.5 GB (including 1 GB for installation)  The computer where the station is installed must be connected to your domain  Microsoft .NET Framework 3.5 SP1
Verification Stations
Verification Station
PC with Intel® Pentium®/Celeron®/Core™2 Duo/Quad/Xeon®/Core™ i3/Core™ i5/Core™ i7, AMD
K6/Turion™/Athlon™/Duron™/Sempron™ with a minimum clock speed of 2 GHz.
Operating system: Windows XP SP3, Windows Vista SP2, Windows 7 SP1, Windows 8/8.1, Win-
dows Server 2003 SP2, Windows Server 2008 SP2 + Desktop Experience, Windows Server 2008 R2 SP1 + Desktop Experience, Windows Server 2012 + Desktop Experience, Windows Server 2012 R2 + Desktop Experience (for localized interfaces, corresponding language support is re­quired)
Memory: 512 MB for each CPU core, but no less than 1 GB  Hard disk space: 1.5 GB (including 1 GB for installation)  Video card and display with a resolution of 1024×768  The computer where the station is installed must be connected to your domain  Microsoft .NET Framework 3.5 SP1
Remote Verification Station
PC with Intel® Pentium®/Celeron®/Core™2 Duo/Quad/Xeon®/Core™ i3/Core™ i5/Core™ i7, AMD
K6/Turion™/Athlon™/Duron™/Sempron™ with a minimum clock speed of 2 GHz.
Operating system: Windows XP SP3, Windows Vista SP2, Windows 7 SP1, Windows 8/8.1, Win-
dows Server 2003 SP2, Windows Server 2008 SP2 + Desktop Experience, Windows Server 2008 R2 SP1 + Desktop Experience, Windows Server 2012 + Desktop Experience, Windows Server 2012 R2 + Desktop Experience (for localized interfaces, corresponding language support is re­quired)
Memory: 1 GB  Hard disk space: 100 MB  Video card and display with a resolution of 1024×768 Microsoft .NET Framework 3.5 SP1
Web Verification Station
Video card and display with a resolution of 1024×768 Silverlight 5.1.20913 or later. (Microsoft Internet Explorer 11 only supports SilverLight when running
under Windows 7 SP1 or Windows 8.1). One of the following web browsers: Internet Explorer 7, 8, 9, 10 or 11.
Browser security settings: Internet Explorer medium-high protection level. Detailed required settings
for Internet Explorer:
© 2014 ABBYY Production LLC. All rights reserved.
10
Run ActiveX controls and plug-ins = Enable  Script ActiveX controls marked safe for scripting = Enable  Active scripting = Enable  File Download = Enable (to install Silverlight)
Note. To insure that Internet Explorer 11 works correctly, install .NET Framework 4.5 on the com-
puter with the Application Server or add the address of an application server to the list of websites
that are opened in compatibility mode.
Note. The Metro-style version of Internet Explorer 10 that comes with Windows 8 is not supported.
Note. Internet Explorer 64-bit is only supported under Windows 7/2008+ if Silverlight 5 is installed.
Mozilla Firefox 14 or later (32-bit).
Security settings for Mozilla Firefox:
Java scripting = Enable  Firefox will remember history (Tools -> Options -> Privacy) = Disable
Google Chrome 20 or later (32-bit).
Security settings for Google Chrome:
JavaScript = Allow all sites  Plug-ins = Run automatically
Note. All plugins are disabled by default. To enable a plugin, open chrome://plugins/ in the browser and select the Always allowed option for the desired plugin.
Data Verification Stations
Data Verification Station
PC with Intel® Pentium®/Celeron®/Core™2 Duo/Quad/Xeon®/Core™ i3/Core™ i5/Core™ i7, AMD
K6/Turion™/Athlon™/Duron™/Sempron™ with a minimum clock speed of 2 GHz.
Operating system: Windows XP SP3, Windows Vista SP2, Windows 7 SP1, Windows 8/8.1, Win-
dows Server 2003 SP2, Windows Server 2008 SP2 + Desktop Experience, Windows Server 2008
R2 SP1 + Desktop Experience, Windows Server 2012 + Desktop Experience, Windows Server
2012 R2 + Desktop Experience (for localized interfaces, corresponding language support is re-
quired)
Memory: 1 GB  Hard disk space: 100 MB  Video card and display with a resolution of 1024×768 Microsoft .NET Framework 3.5 SP1
Web Data Verification Station
Video card and display with a resolution of 1024×768 Silverlight 5.1.20913 or later. (Microsoft Internet Explorer 11 only supports SilverLight when running
under Windows 7 SP1 or Windows 8.1). One of the following web browsers: Internet Explorer 7, 8, 9, 10 or 11.
Browser security settings: Internet Explorer medium-high protection level. Detailed required settings
for Internet Explorer:
Run ActiveX controls and plug-ins = Enable  Script ActiveX controls marked safe for scripting = Enable  Active scripting = Enable  File Download = Enable (to install Silverlight)
Note. To insure that Internet Explorer 11 works correctly, install .NET Framework 4.5 on the com-
puter with the Application Server or add the address of an application server to the list of websites
that are opened in compatibility mode.
Note. The Metro-style version of Internet Explorer 10 that comes with Windows 8 is not supported.
© 2014 ABBYY Production LLC. All rights reserved.
11
Note. Internet Explorer 64-bit is only supported under Windows 7/2008+ if Silverlight 5 is installed.
Mozilla Firefox 14 or later (32-bit).
Security settings for Mozilla Firefox:
Google Chrome 20 or later (32-bit).
Security settings for Google Chrome:
Scanning Stations
Scanning Station
PC with Intel® Pentium®/Celeron®/Core™2 Duo/Quad/Xeon®/Core™ i3/Core™ i5/Core™ i7, AMD
K6/Turion™/Athlon™/Duron™/Sempron™ with a minimum clock speed of 2 GHz.
Operating system: Windows XP SP3, Windows Vista SP2, Windows 7 SP1, Windows 8/8.1, Win-
dows Server 2003 SP2, Windows Server 2008 SP2 + Desktop Experience, Windows Server 2008
R2 SP1 + Desktop Experience, Windows Server 2012 + Desktop Experience, Windows Server
2012 R2 + Desktop Experience (for localized interfaces, corresponding language support is re-
quired)
Memory: 1 GB  Hard disk space: 1 GB (including 200 MB for installation and space for scanned images)
Java scripting = Enable  Firefox will remember history (Tools -> Options -> Privacy) = Disable
JavaScript = Allow all sites  Plug-ins = Run automatically
Note. All plugins are disabled by default. To enable a plugin, open chrome://plugins/ in the browser and select the Always allowed option for the desired plugin.
Scanner supporting TWAIN, WIA or ISIS  Video card and display with a resolution of 1024×768 Microsoft .NET Framework 3.5 SP1
ClickOnce Scanning Station
PC with Intel® Pentium®/Celeron®/Core™2 Duo/Quad/Xeon®/Core™ i3/Core™ i5/Core™ i7, AMD
K6/Turion™/Athlon™/Duron™/Sempron™ with a minimum clock speed of 2 GHz.
Operating system: Windows XP SP3, Windows Vista SP2, Windows 7 SP1, Windows 8/8.1, Win-
dows Server 2003 SP2, Windows Server 2008 SP2 + Desktop Experience, Windows Server 2008
R2 SP1 + Desktop Experience, Windows Server 2012 + Desktop Experience, Windows Server
2012 R2 + Desktop Experience (for localized interfaces, corresponding language support is re-
quired)
Memory: 1 GB  Hard disk space: 1 GB (including 90 MB for installation and space for scanned images). The size of
downloadable file is 41 MB.
Scanner supporting TWAIN, WIA or ISIS  Video card and display with a resolution of 1024×768 Internet Explorer 7 or higher for ClickOnce deployment
Note. To insure that Internet Explorer 11 works correctly, install .NET Framework 4.5 on the com-
puter with the Application Server or add the address of an application server to the list of websites
that are opened in compatibility mode. Microsoft .NET Framework 3.5 SP1
Web Scanning Station
Operating system: Windows XP SP3, Windows Vista SP2, Windows 7 SP1, Windows 8/8.1, Win-
dows Server 2003 SP2, Windows Server 2008 SP2 + Desktop Experience, Windows Server 2008
R2 SP1 + Desktop Experience, Windows Server 2012 + Desktop Experience, Windows Server
2012 R2 + Desktop Experience (for localized interfaces, corresponding language support is re-
quired) Video card and display with a resolution of 1024×768
© 2014 ABBYY Production LLC. All rights reserved.
12
ABBYY Scanning Plug-In
OS
Permissions
UAC
CAB
EXE
Windows
Server 2003
SP2
Administrator
-
User
-
*
Installation is forbidden by
default
Windows XP
SP3
Administrator
-
User
-
Internet Explorer 8 or higher is
required
Windows
Vista SP2,
Windows
Server 2008
SP2
Administrator
Yes
No
Scanner supporting TWAIN. WIA scanners are visible to the station but they are not guaranteed to
work. Silverlight 5.1.20913 or later. (Microsoft Internet Explorer 11 only supports SilverLight when running
under Windows 7 SP1 or Windows 8.1). One of the following web browsers: Internet Explorer 7, 8, 9, 10 or 11.
Browser security settings: Internet Explorer medium-high protection level. Detailed required settings
for Internet Explorer:
Run ActiveX controls and plug-ins = Enable  Script ActiveX controls marked safe for scripting = Enable  Active scripting = Enable  File Download = Enable (to install Silverlight)
Note. To insure that Internet Explorer 11 works correctly, install .NET Framework 4.5 on the com-
puter with the Application Server or add the address of an application server to the list of websites
that are opened in compatibility mode.
Note. The Metro-style version of Internet Explorer 10 that comes with Windows 8 is not supported.
Note. Internet Explorer 64-bit is only supported under Windows 7/2008+ if Silverlight 5 is installed.
Mozilla Firefox 14 or later (32-bit).
Security settings for Mozilla Firefox:
Java scripting = Enable  Firefox will remember history (Tools -> Options -> Privacy) = Disable
Google Chrome 20 or later (32-bit).
Security settings for Google Chrome:
JavaScript = Allow all sites  Plug-ins = Run automatically
Note. All plugins are disabled by default. To enable a plugin, open chrome://plugins/ in the browser and select the Always allowed option for the desired plugin.
The table below lists the operating systems on which the ABBYY Scanning Plug-In can be installed with vari­ous permissions.
© 2014 ABBYY Production LLC. All rights reserved.
13
User
Yes
The administrator password
will be required
No
Internet Explorer 8 or higher is
required
Windows 7
SP1,
Windows
Server
2008 R2
SP1
Administrator
Recommended
No
User
Recommended
The administrator password
will be required
No
Windows
8/8.1
Administrator
Recommended
No
User
Recommended
The administrator password
will be required
No
Windows
Server 2012
Administrator
Recommended
**
Installation is forbidden by
default
© 2014 ABBYY Production LLC. All rights reserved.
14
No
**
Installation is forbidden by
default
User
Recommended
**
Installation is forbidden by
default
No
**
Installation is forbidden by
default
Windows
Server 2012
R2
Administrator
Recommended
**
Installation is forbidden by
default
No
**
Installation is forbidden by
default
User
Recommended
**
Installation is forbidden by
default
No
**
Installation is forbidden by
default
*Note: To allow the ABBYY Scanning Plug-In to be installed by users, select the Disable Windows Installer option (select Computer Configuration -> Administrative Templates -> Windows Components -> Windows In- staller) and set it to Never.
**Note: To allow the ABBYY Scanning Plug-In to be installed on Windows Server 2012, run the executable file Setup.exe as Administrator or change the security policy by setting the value of the registry key HKEY_LOCAL_MACHINE\Software\Policies\Microsoft\Windows\Installer DisableMSI to “0”.
Note: For detailed instructions on how to install the ABBYY Scanning Plug-In, see Web Scanning Station Help.
Web Capture Station
Operating system: Windows XP SP3, Windows Vista SP2, Windows 7 SP1, Windows 8/8.1, Windows Server
2003 SP2, Windows Server 2008 SP2 + Desktop Experience, Windows Server 2008 R2 SP1 + Desktop Ex-
perience, Windows Server 2012 + Desktop Experience, Windows Server 2012 R2 + Desktop Experience (for
localized interfaces, corresponding language support is required)
Video card and display with a resolution of 1024×768 Scanner supporting TWAIN. WIA scanners are visible to the station but they are not guaranteed to work.  Silverlight 5.1.20913 or later. (Microsoft Internet Explorer 11 only supports SilverLight when running under
Windows 7 SP1 or Windows 8.1).
One of the following web browsers: Internet Explorer 7, 8, 9, 10 or 11.
Browser security settings: Internet Explorer medium-high protection level. Detailed required settings for In-
ternet Explorer:
Run ActiveX controls and plug-ins = Enable  Script ActiveX controls marked safe for scripting = Enable  Active scripting = Enable
File Download = Enable (to install Silverlight)
© 2014 ABBYY Production LLC. All rights reserved.
15
Note. To insure that Internet Explorer 11 works correctly, install .NET Framework 4.5 on the computer with
the Application Server or add the address of an application server to the list of websites that are opened in
compatibility mode.
Note. The Metro-style version of Internet Explorer 10 that comes with Windows 8 is not supported.
Note. Internet Explorer 64-bit is only supported under Windows 7/2008+ if Silverlight 5 is installed.
Mozilla Firefox 14 or later (32-bit).
Security settings for Mozilla Firefox:
Java scripting = Enable  Firefox will remember history (Tools -> Options -> Privacy) = Disable
Google Chrome 20 or later (32-bit).
Security settings for Google Chrome:
JavaScript = Allow all sites  Plug-ins = Run automatically
Note. All plugins are disabled by default. To enable a plugin, open chrome://plugins/ in the browser and select the Always allowed option for the desired plugin.
For operation of Web Capture Station, ABBYY Scanning Plug-In must be installed. Installation restrictions
are listed in the table. For detailed instruction on how to install ABBYY Scanning Plug-In, see Web Scanning
Station help.
Supported virtual machines
The following virtual machines are supported:
VMware Server 2.0 (this platform is no longer supported by the manufacturer)  VMware Workstation 6.5 - 9.0  VMware ESXi 4.1.0 (server component of VMware vSphere)  Hyper-V 6.0, 6.1 or 6.2 (Hyper-V version corresponds to the version of the operating system. Under Windows
Server 2008, Hyper-V 6.0 is used.) Note: Hyper-V virtual machines do not work with USB devices. VMware ESXi virtual machines work with Wibu drivers
only, iKey drivers are not supported.
General information
Server operation system like Microsoft Windows Server 2008, 2008R2, 2012 should be used for server part of ABBYY FlexiCapture installation.
The distributed installation of FlexiCapture includes three servers:
Application Server  Licensing Server  Processing Server
The Application Server coordinates the work of the stations ensures the correct operation of ABBYY FlexiCapture. The following three steps are required to install the distributed version of ABBYY FlexiCapture:
1. Prepare the Application Server.
2. Install the servers.
3. Install the workstations.
Preparing the Application Server for installation on Windows 2012
These instructions can also be used when installing the Application Server on Windows 8. The following components must be installed on your computer before you can install the Application Server:
.Net Framework 4.0  IIS (Internet Information Services)  This component can be installed by selecting Install External Components in the Autorun menu.
The .Net Framework 4.5 component is installed by default on Windows 2012 and Windows 8. Information about the installed versions of .Net Framework can be found in the Windows registry. For more information, please refer to the
Microsoft website.
© 2014 ABBYY Production LLC. All rights reserved.
16
IIS is installed using the server administration console. Press the Add roles and features button and select the Web Server (IIS) value in the roles list to install IIS. You may need the Windows installation disk to perform this operation.
The following IIS components must be installed:
.Net Framework 4.5 Features
ASP.NET 4.5
Web Server (IIS)
Web Server
Common HTTP Features
Static Content
Default Document
HTTP Errors
HTTP Redirection
Application Development
.Net Extensibility 4.5
ASP.NET 4.5
ISAPI Extensions
ISAPI Filters
Security
Basic Authentication
Windows Authentication
Request Filtering
Management Tools
IIS Management Console
IIS 6 Management Compatibility
IIS 6 Metabase Compatibility
IIS 6 WMI Compatibility
IIS 6 Scripting Tools You may also install other IIS components.
Preparing the Application Server for installation on Windows Server 2008 R2
This instruction can also be used when installing the Application Server on Windows 2008, Windows 7 and Windows Vista.
Important! Before you start, it is recommended to disable the UAC or to perform all actions using the native adminis­trator account.
To disable UAC:
1. In Control Panel open User Accounts.
2. Click Change User Account Control settings link and in the dialog box that opens, decrease the level of user control to Never notify.
© 2014 ABBYY Production LLC. All rights reserved.
17
3. For changes to take effect, restart the computer after turning off UAC.
The Application Server coordinates the work of the stations ensures the correct operation of ABBYY FlexiCapture. The following components must be installed on your computer before you can install the Application Server:
.Net Framework 4.0
Select Install External Components in the Autorun menu to install this component. Note: Information about the installed versions of .Net Framework can be found in in the Windows regis-
try. For more information, please refer to the Microsoft website.
IIS (Internet Information Services)
The Application Server can only be installed on a computer on which Microsoft Internet Information Server 7 or later is installed. IIS is required for the correct operation of the Application Server, the Administration and Monitoring Console and Web Stations.
To install IIS, do the following:
1. In My Computer local menu, choose Manage.
2. In the Server Manager console that opens, click Add Roles and from the roles list select Web Server (IIS).
© 2014 ABBYY Production LLC. All rights reserved.
18
3. During installation, Windows may ask you for the source distribution files, so you need to have Windows in­stallation CD.
4. Enable installation of the following IIS internal components:
Web Server Common HTTP Features Static Content Default Document HTTP Errors HTTP Redirection Application Development .Net Extensibility 4.5
© 2014 ABBYY Production LLC. All rights reserved.
19
ASP.NET 4.5 ISAPI Extensions ISAPI Filters Security Basic Authentication Windows Authentication Request Filtering Management Tools IIS Management Console IIS 6 Management Compatibility IIS 6 Metabase Compatibility IIS 6 WMI Compatibility IIS 6 Scripting Tools
Other IIS components can be installed according to user preferences, e.g., perform a complete installation of IIS.
Installing the servers
Once you have made the preparations for installing the Application Server, install the servers. By default, all servers are installed on the same computer. However, you can install them on different computers by
disabling the redundant servers in the setup program. To install the ABBYY FlexiCapture servers:
1. In the Autorun menu, select Distributed Installation. Next, select Install Servers to start the installation.
2. Select a setup language. The setup program will compare the locale of your system and the selected lan-
guage. If the languages are incompatible, a warning message is displayed.
3. Next, the setup program checks the version of your operating system and the availability of the administrative permissions. If the version of the operating system is not supported by the program or you do not have the appropriate permissions, a warning message is displayed and the setup program is terminated.
4. If all the checks are passed successfully, the end-user license agreement will be displayed. Read the license agreement carefully and if you agree with the terms of the agreement, select the corresponding option and click Next.
5. A dialog box will open prompting you to enter some information about yourself. Enter the required information and continue with the installation.
6. Next, select the servers to install. You can also specify a destination folder. By default, the program is in- stalled to: %systemdrive%\Program Files (x86)\ABBYY FlexiCapture 11 Servers (%systemdrive%\Program Files\ABBYY FlexiCapture 11 Servers if 32-bit OS version is used).
Processing Server – the server that controls the operation of the Processing Stations Licensing Server – the server that stores and manages licenses. When you install servers on different
workstations, you must specify the address of this server or the Licensing Server in the format server, without \\ or http:// (or IP-address)
Application Server – the server that controls the operation of the other components. When you install
servers on different workstations, you must specify the address of this server or the Application Server in the format server, without \\ or http://
Web Stations – the Application Server components which allow operators to connect to the server and
work using a web-browser.
FlexiCapture Authentication Module – the Application Server component which allows operators of
Web stations to register with the system and create requests for access rights to the Web station. Pro­vides operators of Web stations with a single entry point into the system. By default, this feature is not in­stalled. For more information on how to choose the authentication method, please refer to How to choose
the user authentication type.
Stations Installer – selecting this option will copy the stations’ setup files onto the Application Server so
that you can then deploy them from the server. SMS and Active Directory deployment are supported. Once you select this component, you can specify the destination folder where to copy the setup files.
© 2014 ABBYY Production LLC. All rights reserved.
20
7. Next, the setup program will check if .Net Framework 4.0 (or 4.5, if running under Windows Server 2012) and
IIS are installed on your computer. If any of the components is missing on your computer, the setup program will display a warning message.
8. The program files will be copied onto your computer. Once the installation is finished, the setup program will display a message saying that the application has been successfully installed.
9. Once the installation is complete, License Manager will be launched automatically so that you can activate your serial number. See Managing Your Licenses for details. The Monitoring Station will also be launched, where you can set up the installed Application Server.
10. If you see an error message in the Administration and Monitoring Console, open the IIS Manager console (select Start -> Administrative Tools -> Internet Information Services (IIS) Manager) and check if IIS server and Default Web Site are running:
If the server is stopped, in the Manage Server menu, choose Start. Similarly, check whether Default Web Site is running.
IMPORTANT! The Application Server should be available on the Internet if you wish to use the remote stations over the Internet.
Removing ABBYY FlexiCapture servers in silent mode
msiexec /x {uninstall registry key}. The location of the uninstall registry key:
HKEY_LOCAL_MACHINE\Software\Microsoft\Windows\CurrentVersion\Uninstall (the Product ID is in the name of the subkey with the product name in its values). You can also determine the Product ID by executing the following command in the command line: "wmic product where "Name like '%FlexiCapture%'" get Name, Version,
IdentifyingNumber".
External components required for the correct operation of the system
iKey driver
This component is required if you plan to use a license stored on an iKey USB dongle manufactured by Rain­bow. On a 64-bit operating system, you must install a 64-bit version of iKey driver manually. It can be in­stalled by selecting Install External Components in the Autorun menu.
On 32-bit operating systems, no additional steps are required to install the iKey driver, as it will be installed automatically.
© 2014 ABBYY Production LLC. All rights reserved.
21
CodeMeter runtime
This component is required if you plan to use a license stored on a CodeMeter USB dongle manufactured by Wibu-Systems. No additional steps are required to install the driver. Installation will be done automatically when the Licensing Server is installed.
Microsoft Core XML Services (MSXML6)
This component is required for the operation of the Application Server. It is installed automatically.
Crystal Reports
This component is used by the Administration and Monitoring Console to generate reports. Crystal Reports can be installed on the same computer where the Application Server is installed. Without this component, you will not be able to generate reports. However, all other Application Server management functionality will be available. ABBYY FlexiCapture supports Crystal Reports basic for Visual Studio .NET 2008 and Crystal Reports 2010. Crystal Reports is not installed automatically and should be installed manually. A 32-bit ver­sion of Crystal Reports basic for Visual Studio .NET 2008 can be installed by selecting Install External Com­ponents in the Autorun menu.
Note: Whether to install a 32- or 64-bit version of Crystal Reports is determined by the mode, in which the pool of the Administration and Monitoring Console is running in IIS (FlexiCapture 11 Monitoring). For details,
see “System components in IIS and their configuration.” By default the pool of Administration and Monitoring
Console runs in 32-bit mode. However, it can be transferred to 64-bit mode, which allows you to use Crystal Reports 64-bit. For details, see “Switching system components to 64-bit mode.”
If the bit does not match or Crystal Reports is not installed, the following error message will appear: A runtime error occurred:
CrystalReports loading failed Details: Description Exception has been thrown by the target of an invocation. Source mscorlib Stack trace at System.RuntimeTypeHandle.CreateInstance(RuntimeType type, Boolean publicOnly, Boolean noCheck, Boolean& canBeCached, RuntimeMethodHandle& ctor, Boolean& bNeedSecurityCheck) at Sys­tem.RuntimeType.CreateInstanceSlow(Boolean publicOnly, Boolean fillCache) at Sys­tem.RuntimeType.CreateInstanceImpl(Boolean publicOnly, Boolean skipVisibilityChecks, Boolean fillCache) at System.Activator.CreateInstance(Type type, Boolean nonPublic) at Sys­tem.RuntimeType.CreateInstanceImpl(BindingFlags bindingAttr, Binder binder, Object[] args, CultureInfo cul­ture, Object[] activationAttributes) at System.Activator.CreateInstance(Type type, BindingFlags bindingAttr, Binder binder, Object[] args, CultureInfo culture, Object[] activationAttributes) at Sys­tem.Reflection.Assembly.CreateInstance(String typeName, Boolean ignoreCase, BindingFlags bindingAttr, Binder binder, Object[] args, CultureInfo culture, Object[] activationAttributes) at ReportManager.loadCrystalReports()
System components in IIS and their configuration
This section describes the IIS configuration which is required for the operation of FlexiCapture. This configuration is selected automatically when you install the program. However, if any errors occur, the information in this section may help you make sure that IIS is configured correctly.
Application pools
During the installation of the Application Server, the installer automatically adds three IIS application pools associated with ABBYY FlexiCapture 11. Application pools enable interaction with workflows bound to one or more applications and sharing data between them.
FlexiCapture 11 Monitoring – enables the operation of the Administration and Monitoring Console FlexiCapture 11 Web Services – enables the operation of the Application Server. FlexiCapture 11 Web Stations – enables the operation of the Web stations: Web Verification station, Web Data Veri-
fication station, and Web Capture station. All pools are configured automatically during the installation of ABBYY FlexiCapture. Pool settings critical for correct
operation of the Application Server, are listed below:
- .Net Framework Version = v4.0
© 2014 ABBYY Production LLC. All rights reserved.
22
- Managed Pipeline Mode = Integrated
- Identity = NetworkService
ABBYY FlexiCapture application pools work in 32-bit mode. In IIS Manager Console, you can check if 32-bit mode is enabled. For this, do the following:
1. Run the IIS Manager Console by selecting Start -> Administrative Tools -> Internet Information Services (IIS) Manager.
2. Choose Application Pools.
© 2014 ABBYY Production LLC. All rights reserved.
23
3. Choose a desired pool from the list. In the Actions menu, select Advanced Settings…
The value of Enable 32-Bit Application must be True. It means that the pool works in 32-bit mode. Besides, the installer adds the following applications to Default Web Site (the set of applications depends on the con-
figuration selected during the installation): Default Web Site\FlexiCapture11\Monitoring the Administration and Monitoring Console
© 2014 ABBYY Production LLC. All rights reserved.
24
Default Web Site\FlexiCapture11\Server – the Application Server, in particular: Default Web Site\FlexiCapture11\Server\WebServices.dll – a web service of the Application Server which supports
both Windows and Basic authentication. Default Web Site\FlexiCapture11\Server\WebServicesExternal.dll a web service of the Application Server which
supports authentication by means of the FlexiCapture Authentication Module (this will be added if FlexiCapture Au­thentication Module was selected during the installation of ABBYY FlexiCapture Servers).
Default Web Site\FlexiCapture11\Login a Web-based interface for login and registration (this will be added if FlexiCapture Authentication Module was selected during the installation of ABBYY FlexiCapture Servers)
Default Web Site\FlexiCapture11\DataVerification Web Data Verification Station (will be added if the Web Sta- tions component is selected during the installation of ABBYY FlexiCapture Servers)
Default Web Site\FlexiCapture11\Verification Web Verification Station (this will be added if the Web Stations component is selected during the installation of ABBYY FlexiCapture Servers)
Default Web Site\FlexiCapture11\Scanning Web Scanning Station (will be added if the Web Stations component is selected during the installation of ABBYY FlexiCapture Servers)
Default Web Site\FlexiCapture11\Capture Web Capture Station (will be added if the Web Stations component is selected during the installation of ABBYY FlexiCapture Servers)
Authentication settings for FlexiCapture Web Applications
To control access to the applications via http protocol, it is necessary to configure authentication settings (log­in/password-based connection verification of a user’s identity). For this, choose a desired application and then choose the Authentication item.
Then select a required authentication method from the list and enable it.
© 2014 ABBYY Production LLC. All rights reserved.
25
To access ABBYY FlexiCapture applications, different authentication types are used: Windows authentication a user tries to login to the server using the same credential under which the user browser
runs. (Using UTF-8-encoded characters in the user name and the password may be not supported.) To pass Windows authentication, the user must be either a local user of the computer or a user of the domain which includes this com­puter.
Basic authentication – login and password are transmitted over the network in clear text. To pass Windows authen­tication, the user must be either a local user of the computer or a user of the domain which includes this computer.
Anonymous authentication – the server does not require the client to transfer the credential. Users accessing the server operate under a special local account, that is, they are considered local users and are authenticated on their computers.
FlexiCapture Authentication Module (ABBYY FlexiCapture Authentication) user name and password are passed the same way as when using Basic authentication, authentication is performed against a FlexiCapture data-
base which stores users’ logins and password hashes. To pass the authentication, it is necessary that the login and
password of the account match the login and password specified in the FlexiCapture database. This makes it possible to use logins and passwords which are not related to Windows user accounts.
By default, the FlexiCapture Authentication Module is not installed during the installation of servers. In this case, the following authentication settings are specified in IIS:
Default Web Site\FlexiCapture11\Monitoring (Administration and Monitoring Console) - only Windows authentica­tion:
© 2014 ABBYY Production LLC. All rights reserved.
26
Default Web Site\FlexiCapture11\Server (Application Server) - both Windows authentication and Basic authentica­tion are enabled:
© 2014 ABBYY Production LLC. All rights reserved.
27
Default Web Site\FlexiCapture11\DataVerification (Web Data Verification Station) - only Anonymous authentication is enabled:
Default Web Site\FlexiCapture11\Verification (Web Verification Station) - only Anonymous authentication is ena­bled.
Default Web Site\FlexiCapture11\Scanning (Web Scanning Station) - only Anonymous authentication is enabled. Default Web Site\FlexiCapture11\Capture (Web Capture Station) - only Anonymous authentication is enabled.
If the FlexiCapture Authentication Module was installed, the following authentication settings are specified in IIS: Default Web Site\FlexiCapture11\Monitoring (Administration and Monitoring Console) - only FlexiCapture authenti-
cation is enabled for this folder and all its files and subfolders, except for the Default Web Site\FlexiCapture11\Monitoring\DBConnection.aspx page, for which only Windows authentication is enabled, and for the Server folder. For all pages, except for the DBConnection.aspx page, redirecting to the Default Web Site\Login page is configured in the case of the HTTP 401 error, which enables automatic switching to the login page if the user cannot pass the FlexiCapture authentication.
Default Web Site\FlexiCapture11\Server (Application Server) - Windows, Basic, and FlexiCapture authentications are enabled for this folder and all its files and subfolder, except for the Default Web
Site\FlexiCapture11\Server\WebServices\External.dll file, for which only FlexiCapture authentication is enabled. Default Web Site\FlexiCapture11\Login (Web-based interface for logging on existing users or registering new users)
- only Anonymous authentication is enabled. Default Web Site\FlexiCapture11\DataVerification (Web Data Verification Station) - only Anonymous authentication
is enabled. Default Web Site\FlexiCapture11\Verification (Web Verification Station) - only Anonymous authentication is ena-
bled.
© 2014 ABBYY Production LLC. All rights reserved.
28
Default Web Site\FlexiCapture11\Scanning (Web Scanning Station) - only Anonymous authentication is enabled. Default Web Site\FlexiCapture11\Capture (Web Capture Station) - only Anonymous authentication is enabled.
Handler Mappings
In IIS services, handlers process requests to sites and applications. The handlers are mapped to resources on a web server and create responses to those requests. Like the modules, the handlers are implemented using native or man­aged components, such a dynamic DLL or managed code.
After the installation of ABBYY FlexiCapture Application Server, the installer performs the following actions:
1) Adds to IIS the mappings required for correct processing requests from the Application Server. These map­pings can be view in the IIS Manager console. For this, select the Handler Mappings item for Default Web Site\FlexiCapture11\Server (the Application Server).
For correct operation of the Application Server, the installer creates a mapping “ABBYY FlexiCapture WebService”
with the following parameters:
Request path = “*.dll” Executable = ”C:\inetpub\wwwroot\FlexiCapture11\Server\WebServicesIsapi.dll”
© 2014 ABBYY Production LLC. All rights reserved.
29
Access = “Script”
Note: It may happen that a third-party application is installed on the same computer as the Application Server, and it can intercept requests of ABBYY FlexiCapture. In this case, the following error message will occur when starting the Administration and Monitoring console:
A runtime error occurred: Cannot get file storage path Details: Description Client found response content type of 'text/html; charset=utf-8', but expected 'text/xml'. The request failed
with the error message: -- Server Error in Application "DEFAULT WEB SITE/FLEXICAPTURE11/SERVER"Internet Information Services 7.5
Error Summary HTTP Error 500.0 - Internal Server Error There is a problem with the resource you are looking for, so it cannot be displayed. Detailed Error InformationModule
IsapiModule Notification ExecuteRequestHandler
© 2014 ABBYY Production LLC. All rights reserved.
30
Handler Custom Handler Error Code 0x8007007f Requested URL http://127.0.0.1:80/FlexiCapture11/Server/WebServices.dll?Handler=Default Physical Path C:\inetpub\wwwroot\FlexiCapture11\Server\WebServices.dll Logon Method Negotiate Logon User WORKGROUP\WIN-COSLCUOARGA$ In this case, a handler which intercepts the request to the Application Server is called Custom Handler.
2) For the Default Web Site\FlexiCapture11\Scanning and Default Web Site\FlexiCapture11\Capture appli­cations, installs the level AccessPolicy = Read, Script (Execute = false). To set the parameter value manual­ly, choose the application in the applications tree, go to the Handler Mappings section, and choose the Edit Feature Permissions command from the Actions menu.
ISAPI and CGI Restrictions
The installer of FlexiCapture servers creates an allowance for the ISAPI-extension of the Application Server. To view the list of allowed ISAPI-extensions, at the upper level of the IIS Manager console (the level of IIS server)
select ISAPI and CGI Restrictions.
“FlexiCapture 11 Web Services” extension (path “C:\inetpub\wwwroot\FlexiCapture11\Server\IsapiLoader.dll”) must be allowed.
© 2014 ABBYY Production LLC. All rights reserved.