ABB Welcome User Manual

Page 1
Door Entry System
System Manual
ABB-Welcome
Page 2
Welcome
Leading to a flexible and simple world
The new door entry system ABB - Welcome is a new product range for more flexible application in 2-wire technology.
By the simple 2-wire bus and modular design of outdoor stations, the installers will have a variety of choices for any kind of application of single-family house, multi-family buildings and residential complex, no matter for new buildings or renovation.
2 | ABB-Welcome
ABB-Welcome | 3
Page 3
Welcome
More flexibility and simplicity
Thanks to the modular design and extremely versatile 2-wire bus system, the new Welcome range is designed with the concept of flexibility, simplicity and elegance. Therefore installation and usage become much easier and more comfortable. With the wide range of well-designed products, Welcome meets all your needs for door entry.
01 02
03 04
10
06
07
11
08
12
09
13
05
4 | ABB-Welcome
01 One-family house 02 Multi-family house 03 Apartment building 04 High rise building 05 Residential Complex
06 Welcome video pushbutton outdoor station, white 07 Welcome video pushbutton outdoor station, aluminum 08 Welcome video keypad outdoor station, white 09 Welcome video keypad outdoor station, aluminum 10 Welcome 7" video hands-free indoor station, white 11 Welcome 4.3" video hands-free indoor station, white 12 Welcome 4.3" video handset indoor station, white 13 Welcome audio handset indoor station, 3 buttons , white
ABB-Welcome | 5
Page 4
Contents
Terminology
01 Examples of typical system
02 Planning
03 Installation
04 Commissioning
05 Operation
06 Overview of product range
07 Connection
08 Technical assistant tool
Legend
08/132
12/132
20/132
85/132
93/132
102/132
104/132
113/132
128/132
130/132
6 | ABB-Welcome
ABB-Welcome | 7
Page 5
Terminology
In order to logically and easily understand Welcome system for installation, terminologies are defined below with illustrations . It is strongly recommended to read them first before other chapters.
Insulated system
The insulated system is a system in which all devices are managed by one system controller and isolated by a gateway if get networked. The operation within an insulated system will work independently and not interrupt other insulated systems. This is an important concept, both power consumption and distance calculation are made based on the insulated system.
Fig.1
Branch connection
Branch connection is a connection layout of devices. With the branch connection, the same type of devices are not connected with each other like looping connection, sometimes an additional device, such as a video indoor distributor is needed. Usually, the branch connection of indoor stations or gateways is coexisting with looping connection of video distributor.
Common part
The common part is the bus of the networked system —the insulated system where gate station, gateway (only the part out of building) and other related system devices are installed.
System C is a typical networked system where the system controller manages the gate station, guard unit and gateways.
Fig.1
Building part
The building part is the bus of the individual building system
System B is a typical branch connection where the indoor stations are connected by branch and video indoor distributors are needed with looping connecting.
Internal bus
Fig.2
Fig.1
The system controller supplies the other bus subscribers with voltage and controls communication on the 2-wire bus. Starting from the system controller, the 2-wire bus is divided
into 2 parts — the internal bus and external bus. — the insulated system where the outdoor station and indoor stations and other related system devices are installed.
The internal bus is the bus for controlling devices of indoors
or sub insulated system devices. In the building system, it System A and B are typical building systems where the system controller manages the outdoor station, gateway, video indoor distributor, and audio/video indoor stations.
Fig.1
refers to the bus line from system controller to the last indoor
station. In the networked system, it refers to the bus line from
system controller to the last gateway.
Fig.1
A,B and C are 3 insulated systems
Fig.2
Internal bus and external bus in building system
In. — Internal bus Ex. — External bus
Looping connection
Looping connection is a connection layout of devices. With the looping connection, the same type of devices are connected one after another. The device can be indoor station, video distributor or gateway.
System A shows the looping connection of audio indoor stations in one building, and system C shows the looping connection of gateway (the ones inside the building) in a networked system.
Fig.1
External bus
Fig.2
The external bus is the bus for controlling devices of outdoors
of the same insulated system and outdoor related system
devices. In the building trunk system, it refers to the bus line
from system controller to outdoor station. In the networked
system, it refers to the bus line from system controller to the
gate station.
Internal bus and external bus in networked system
In. — Internal bus Ex. — External bus
Note: Graphic symbols are explained in the legend on page 130
8 | ABB-Welcome
ABB-Welcome | 9
Page 6
Fig.3
Fig.4
Apartment system
For multi-insulated systems with multi-system controllers, when an insulated system is for an apartment, this is called apartment system.
Fig.3
A group of villas/single-families linking into a networked system can also be taken as one form of apartment system.
Fig.4
The gateway address is set subsequently one upon another while no addressing is needed at the indoor station.
Floor system
For multi-insulated systems with multi-system controllers,
when an insulated system for a building oor that contains several apartments ( for example on a oor ) , this is called oor
system.
Fig.5
A group of multi-family buildings linking into a networked
system can also be taken as one form of oor system.
Fig.6
Video system
For insulated system with only one system controller, in addition to the transmission of the control information, the audio signal as well as the video signal is transmitted on a 2-wire bus, it is video system.
The right insulated system of Fig.6 (system B) is a typical video system.
For video systems, at least one video outdoor station should be present, the indoor station can be purely audio or at least one video indoor station.
Outdoor stations
Like one person may have different roles such as father, employee, etc., the outdoor station can be named differently when installed in different places. When no specific referring to certain installing environment, it is called outdoor station as a general.
Apartment system for apartments
Fig.5
Floor system for apartments in a floor
Apartment system for a group of villas
The gateway address should be set based on the address of
the rst indoor station managed by this gateway.
Building system
For multi-insulated systems with multi-system controllers, when an insulated system is for one building, this is called building system. A high-rise building with more than 250 apartments breaking down into several parts and being able to be called from the same gate station can also be taken as one form of building system.
Fig.7
The gateway address is set subsequently one upon another.
Audio system
For insulated system with only one system controller, in addition to the control information(unlock), only audio signal is transmitted on a 2-wire bus, it is audio system.
The left insulated system of Fig. 6 (system A) is a typical audio system.
Neither video outdoor station nor video indoor station will be present in audio systems.
When the outdoor station is installed in the door of an apartment or villa, it is called apartment/villa outdoor station.
When the outdoor station is installed in the door for several apartments on that floor, it is called floor outdoor station.
When the outdoor station is installed in the door for one building, it is called building outdoor station.
When the outdoor station is installed in a general entrance for the residential complexes, it is called gate station.
Parallel outdoor stations
With one system controller, when several outdoor stations are connected (with different addresses set), it is called parallel outdoor stations.
Parallel indoor stations
When several indoor stations are set as the same address for one apartment (expect apartment system), it is called parallel indoor stations.
While for apartment system, parallel indoor stations use different addresses, such as the case on page 60 Fig.74.
Fig.6 Fig.7
Floor system for a group of multi-family buildings
Building system for building with more than 250 apartments
250 apartments
250 apartments
250 apartments
10 | ABB-Welcome
ABB-Welcome | 11
Page 7
01 Examples of typical
system
01
Examples of typical system
Welcome answers to all your needs in all contexts, no matter
Fig.8
Single family home
»
System type: audio/video combined
»
Wiring: looped from devices to devices
»
Devices used » One video outdoor station, 1-row push button » One flush mounted box, size 1/2 » One mini system controller » One 4.3" hands-free video indoor station, white » One 4.3" handset video indoor station, white
» One audio handset indoor station, white
» One electric door opener (not provided by ABB)
for new construction or renovation of old buildings, no matter for single-family houses, multi-family houses, high-rise buildings with more than 250 apartments or residential complex.
Single-family house, audio/video
Welcome system consists at minimum of a system controller, outdoor station and indoor station. In Fig.1 three indoor stations are installed in one house. When a visitor rings the bell at the video outdoor station, the call can be answered at either the 4,3" video hands-free indoor station, the 4,3" handset video indoor station, or the audio indoor station.
Fig.8
Multi-family building, audio
Retrofitting a Welcome system in a multi-family house with existing wiring is very easy. Even a plain bell system can be converted to audio or video system. Depending on the local circumstances, an installation with recourse to a rising mains, as shown in Fig.2, is recommended. The wires branch off on each floor where the existing apartments are located – to where an audio indoor station with handset is mounted. There the user can answer incoming calls, open the pedestrian door and the garage door. Also door bell buttons can be used. These are connected to the indoor station.
Fig.9
The drawing shows the easy-to-install 2-wire bus. From the door opener to audio/video outdoor station. And from there to the mini system controller whose working mode is “one on”. And from there to 4.3" hands-free indoor station, which loops through to 4.3" handset indoor station and audio indoor station. No additional distributors are required.
Fig.9
Multi-family building, audio
»
System type: audio
»
Wiring: rising mains with branch connections
»
Devices used » One audio outdoor station with the composed of: » one audio module with 1-row push button » one cover frame » one 4-row push button module » one flush mounted box, size 1/2 » One mini system controller
» Ten audio handset indoor station, white » One electric door opener(not provided by ABB)
12 | ABB-Welcome
12 | ABB-Welcome
The audio solution for the multi-family houses. The drawing shows the easy-to-install 2-wire bus from the electrical door opener to outdoor audio station, from there to the system controller and from there to the audio indoor station with handset. No additional distributors are required. In case of future renovation into video system, then a video distributor is needed for every 4 indoor stations.
ABB-Welcome | 13
Page 8
High-rise building, audio/video
Fig.10
The setup of a video system or a combined audio/video system can include an existing rising mains. To correctly distribute the video image of the outdoor station inside the house, video distributors are installed in each branch box. Once one system controller can not cover all the power consumption of the devices, additional power supply in the bus should be added by the combination of gateway and system controller.
01 Examples of typical
system
Group of villas, audio/video
For a group of villas/single-family houses, a gate station can be equipped as the main entrance. The gateway installed in each villa/single-family ensures the independent operation of each villa/single-family and links the whole group as a networked system.
Fig.11
Fig.10
High-rise building, audio/video
»
System type: audio/video combined
»
Wiring: branch line by distributor connection
»
Devices used
»
One keypad outdoor station
»
One flush mounted box, size 1/4
»
Three system controllers
»
Two gateways
»
Twenty five video indoor distributors
»
Fifty audio handset indoor stations. white
»
Fifty video 4.3’’ hands-free indoor stations. white
»
One electric door opener (not provided by ABB)
The drawing shows the easy-to-install 2-wire bus from the electrical door opener to outdoor audio station, from there to the system controller and from there to the audio indoor station with handset. An additional system controller and a gateway works as auxiliary power supply is needed to support the bus line for power consumption.
Fig.11
Group of single family homes, audio/video
»
System type: audio/video combined
»
Wiring: branch line by distributor connection
» Devices used » One keypad outdoor station
» that includes:
» one camera module » one audio module » one cover frame » two pcs of 4-row pushbutton module
» one flush mounted box, size 1/4 » One system controller » Four video indoor distributors » Sixteen sets of villa kit » Sixteen gateways » One electric door opener (not provided by ABB)
The solution for a group of single family homes networked together. The drawing shows the easy-to-install 2-wire bus from the electrical door opener to gate station, from there to the system controller from there to the video indoor distributor, and from there to villa system and to video hands-free indoor station. Each villa system should add a gateway to be insulated from the networked bus.
14 | ABB-Welcome
ABB-Welcome | 15
Page 9
Fig.
High-rise building with floor entrance, video
12
For a high-rise building, a pushbutton outdoor station is present on each floor as the second entrance to reach the apartment door. The gateway installed on each floor ensures their independent operation within the building.
01 Examples of typical
system
Resident complexes, audio/video
For residential complexes that may include single family homes, multi-family houses and high-rise buildings, common gate station(s) are present with guard unit(s). The gateway installed in each single family home /high-rise building ensures their independent operation within the building and links the whole group as a networked system.
Fig.13
Fig.12
High-rise building with floor entrance, video
»
System type: audio/video combined
»
Wiring: branch line by distributor connection
»
Devices used
»
One keypad outdoor station
»
One flush mounted box, size 1/4
»
Five video outdoor stations, each containing:
»
one came modules
»
one audio modules
»
one cover frame
»
one flush mounted box
»
One system controller
»
Five mini system controllers
»
Five gateways
»
Five video indoor distributors
» Fifteen 4.3" video hands-free indoor stations, white
»
Six electric door opener (not provided by ABB)
The drawing shows the easy-to-install 2-wire bus from the electrical door opener to outdoor station, from there to the system controller, from there to floor gateway, and from there to floor system and to video hands-free indoor station. Each floor system should add a gateway to be insulated from the networked bus.
Fig.13
Residential complexes, audio/video
»
System type: audio/video combined
»
Wiring: branch line by distributor connection
» Devices used
» One keypad outdoor station » One flush mounted box, size 1/4 » Two video outdoor stations, each composed of:
» one camera module » one audio module » one cover frame » one flush mounted box
» Two audio outdoor stations, each composed of:
» one audio module with 1-row pushbutton » one 4-row pushbutton module » one cover frame » one flush mounted box, size 1/2
» Five mini system controllers » One video indoor distributor » Four gateways » Eight 4.3" hands-free video indoor stations, white
» Twenty audio handset indoor stations. white » Five electric door openers (not provided by ABB)
The drawing shows the easy-to-install 2-wire bus from the electrical door opener to gate station, from there to the system controller, from there to video distributor, and from there to each insulated building system and to audio handset indoor station. Each building system should add a gateway to be insulated from the networked bus.
16 | ABB-Welcome
ABB-Welcome | 17
Page 10
Commercial objects, audio/video
Fig.14
For buildings with several entrances (doctor's office, law firm, small businesses, etc.), these can be individually equipped with outdoor stations. A combination of audio outdoor stations and video outdoor stations is possible. For this application, a video outdoor distributor as MDRC unit must be used. The door, from which the bell is rung, is opened by the indoor station called.
01 Examples of typical
system
Fig.14
Commercial objects, video/audio
»
System type: audio/video combined
»
Wiring: looped from devices to devices
»
Devices used
»
Two video outdoor stations, each composed of: » one camera module
» one audio module
» one cover frame » one flush mounted box
»
Two audio outdoor stations composed of: » one audio module » one cover frame » two flush mounted boxes
»
One system controller
»
Three video outdoor distributors
»
One audio handset indoor station. white
»
One video hands-free indoor station. white
»
One video handset indoor station. white
» Four electric door opener (not provided by ABB)
The drawing shows the easy-to-install 2-wire bus connect indoor stations and multi outdoor stations. The outdoor distributor is needed to connect the multi outdoor stations together.
18 | ABB-Welcome
ABB-Welcome | 19
Page 11
02 Planning
02
Planning
Either by providing an all-round and easy-to-understand table to grasp all the possibilities of the combination of outdoor station, indoor station and system device, or by supplying a few simple rules for flexible topology and power consumption and distance calculation to meet the project requirement, this makes even complex projects easy to manage and easy to implement at a later stage.
In most cases, the existing lines can be used. The universally used 2-wire bus technology allows a bell system to be upgraded to a video system with outdoor camera.
Welcome system can be set up with one system controller or with multi-system controllers. For both types, every system controller makes an insulated system.
For each insulated system, it can be exclusively an audio system. In the building part, visitors and residents use it to communicate between audio outdoor stations and audio indoor stations. In the common part, if a guard unit is present, the visitor and guard can communicate with each other.
The insulated system can also be a video system. This makes the camera image of the video outdoor station visible at the video indoor stations in the building part, or image of video gate station visible at the guard units in the common part.
This chapter includes below sections to make the planning job easier
2.1 Capacity of Welcome system
2.2 Selection of the outdoor station
2.3 Selection of the indoor station
2.4 Selection of the system devices
2.5 System topology
2.6 Power consumer calculation and distance calculation to an insulated system
2.7 Easy reference for the modular outdoor station solution
20 | ABB-Welcome
ABB-Welcome | 21
Page 12
02 Planning System capacity
2.1 Capacity of Welcome system
The system capacity is determined by the valid address number of the devices. Two kinds of addressing are used in Welcome system: Independent addressing and combined addressing.
»
For independent addressing, the devices' addresses are independent in the common part and in the building part.
»
For combined addressing, the total address number of the devices in every building and the devices in common part-should
be less than a certain value.
Fig.15
Capacity of Welcome system
Outdoor station Switch actuatorIndoor station
-
(independent
addressing)
Total address:
(combined
addressing)
Total address of independent addressing =Common part or every individual building part, two parts are independent
* Total address of combine addressing =Common part + every individual building part , two parts are combined
250 60 - building gateway mode
Gateway Guard unit
9
99 - apartment/Floor gateway mode
-- -
Outdoor station
The outdoor station of Welcome system includes the building outdoor station,single family home outdoor station, gate station, and second confirmed outdoor station. The total address number of outdoor stations is 9 for all kinds of entry
Gateway
The address of gateway is using independent addressing. The total address of gateway varies when it is set as different modes for application.
level. The following are some examples of the address of door stations:
»
In one video system with only one building/single family home, 9 outdoor stations can be installed.
»
In a networked system, 4 gate stations in the common part,
The total address number of gateways when it is set as apartment gateway or floor gateway is 99. The available number of address of gateway when set as building gateway is 60. Please refer to page 41-45 for gateway setting for application.
and each building has 4 building outdoor stations and one second confirmed outdoor station in each of the apartment, total 9 (4+4+1) outdoor stations can be installed for the apartment.
Fig.15(B4)
Guard unit
The address of guard unit is using independent addressing. Total up to 9 guard units is allowed in a video system of one building or in the building part of networked system. In one
Or 5 building outdoor stations for one single family home and 4 gate stations in the common part, total 9 (5+4) outdoor stations can be installed for the apartment.
Fig.15(B54)
networked system, total up to 9 guard units is allowed in the common part.
Switch actuator
Indoor station
In a single building or in the building part of a networked system, the total address number of indoor stations is 250.
»
In one audio/video system for one building of up to 250
apartments.
»
In one networked system, with each building of up to 250
apartments
Fig.15(B1)
The address of switch actuator uses combined addressing. Up to 199 switch actuators can be connected. For example:
»
In a system with one building with 199 apartments, each
apartment can install one switch actuator.
»
In a networked system, 4 switch actuators can be installed
in the common part, and 195 switch actuators can be installed in every building.
-Total address:
1999
22 | ABB-Welcome
ABB-Welcome | 23
Page 13
02 Planning Outdoor station selection
2.2 Selection of the modular outdoor station
Welcome provides a wide range of outdoor stations with pushbutton by the combination of the modules, covers and boxes.
Fig.16
Composition of an pushbutton outdoor station
Audio pushbutton outdoor station composition
Composition of pushbutton outdoor station
For pushbutton outdoor stations, it multiples the application by setting as one column or double column for the same pushbutton module. The setting is made by the audio modules. We call the different pushbutton status "single row" or "double row". 3-row pushbutton and 4-row pushbutton are optional for application. For pushbutton outdoor stations, to compose an outdoor station, audio module (with no pushbutton, with 1-row pushbutton or 2-row pushbutton), pushbutton module (3-row pushbutton or 4-row pushbutton), cover frame and flush mounted boxes are compulsory. If surface mounting is required, a rain hood is needed.
Fig.16
There is a quick composition table for pushbutton outdoor station on page 21-24. Please follow the guide below and refer to the table to choose the articles for the desired pushbutton outdoor station.
Step 1: Audio or video? Please refer to page 21-22 for audio pushbutton outdoor station and page 23-24 for video pushbutton outdoor station.
Step 2: 3-row pushbutton or 4-row pushbutton? Please refer to the 3-row pushbutton or 4-row pushbutton table for different pushbuttonapplication.
»
It is technically possible but esthetically, inconsistent for combining audio module with pushbutton and 3-row pushbutton module. For better appearance as an outdoor station, the composition of pushbuttons follows the rule that every pushbutton should have the same height. Thus if 3-row pushbutton module is used, audio module with pushbutton and 4-row pushbutton module are not recommended.
Please decide whether single row or double row pushbutton is needed, then please turn to the button ranges to quickly locate the possible composition.
»
In case the light and call guard functions are required for the outdoor station, then the total buttons should be the combination of the apartment no. and button number for extra functions.
»
In case it is not sure whether single or double pushbuttons for one row is optimal, it is also possible to turn to the pushbutton range to see all the possibilities.
Step 4: Choose the right composition by balancing the cost
and esthetics
»
There may be more than one possibility of compositing
outdoor station in certain cases by choosing 3-row pushbutton module or 4-row pushbutton module, choosing a nameplate module or not and setting as single row or double row for the same pushbutton module. It is advised to consider the cost and esthetics together when making the composition decision.
Video pushbutton outdoor station composition
Nameplate module use case
Step 3: How many calls are needed?
24 | ABB-Welcome
Rainhood use case
ABB-Welcome | 25
Page 14
02 Planning Outdoor station selection
Audio outdoor station
Button Range
Single
Double
Row*
1 - 2 1 - 4 1 1 - 2 2 1 - 4
3 - 5 5 - 10 3 5 - 6 4 7 - 8 5 9 - 10 x1
6 - 8 11 - 16 6 11 - 12 7 13 - 14 8 15 - 16 x2
9 - 11 17 - 22 9 17 - 18 10 19 - 20 11 21 - 22 x3
12 - 14 23 - 28 12 23 - 24 13 25 - 26 14 27 - 28 x4
15 - 17 29 - 34 15 29 - 30 16 31 - 32 17 33 - 34 x5
18 - 20 35 - 40 18 35 - 36 19 37 - 38 20 39 - 40 x6 x1
21 - 23 41 - 46 21 41 - 42 22 43 - 44 23 45 - 46 x7
24 - 26 47 - 52 24 47 - 48 25 49 - 50 26 51 - 52 x8 x1
27 - 29 53 - 58 27 53 - 54 28 55 - 56 29 57 - 58 x9
30 - 32 59 - 64 30 59 - 60 31 61 - 62 32 63 - 64 x10 x1
33 - 35 65 - 70 33 65 - 66 34 67 - 68 35 69 - 70 x11
M251021A-. M251022A-. M251023A-. M251021P3 51021DN 51021CF-. +
Row*
x1 x1 x1
Single Double Single Double Single Double
Audio Module
* Optional to install rain hood
Pushbutton Module
&
Nameplate Module
3-row pushbutton
Article No.
Cover Frame & Flush Mounted Box
41021F
51022CF-. + 41022F
51021RH 51022RH 51023RH 51024RH 51028RH 51025RH 51026RH 51029RH 51027RH
51023CF-. + 41023F
51024CF-. + 41024F
51028CF-. + 41028F
51025CF-. + 41025F
51026CF-. + 41026F
51029CF-. + 41029F
51024CF-. + 41024F + 51021J
Video outdoor station
3-row pushbutton
Button Range
Single Row*
1 - 2 1 - 4 1 1 - 2 2 1 - 4
3 - 5 5 - 10 3 5 - 6 4 7 - 8 5 9 - 10 x1
6 - 8 11 - 16 6 11 - 12 7 13 - 14 8 15 - 16 x2
9 - 11 17 - 22 9 17 - 18 10 19 - 20 11 21 - 22 x3
12 - 14 23 - 28 12 23 - 24 13 25 - 26 14 27 - 28 x4
15 - 17 29 - 34 15 29 - 30 16 31 - 32 17 33 - 34 x5 x1
18 - 20 35 - 40 18 35 - 36 19 37 - 38 20 39 - 40 x6
21 - 23 41 - 46 21 41 - 42 22 43 - 44 23 45 - 46 x7 x1
24 - 26 47 - 52 24 47 - 48 25 49 - 50 26 51 - 52 x8
27 - 29 53 - 58 27 53 - 54 28 55 - 56 29 57 - 58 x9 x1
30 - 32 59 - 64 30 59 - 60 31 61 - 62 32 63 - 64 x10
Double Row*
Camera Module
M251021C
M251021A-. M251022A-. M251023A-. M251021P3 51021DN 51022CF-. +
x1 x1 x1 x1
Single Double Single Double Single Double
Audio Module
* Optional to install rain hood
Pushbutton Module
&
Nameplate Module
Article No.
Cover Frame & Flush Mounted Box
41022F
51023CF-. + 41023F
51022RH 51023RH 51024RH 51028RH 51025RH 51026RH 51029RH 51027RH
51024CF-. + 41024F
51028CF-. + 41028F
51025CF-. + 41025F
51026CF-. + 41026F
51029CF-. + 41029F
51024CF-. + 41024F + 51021J
Button Range
Single
Double
Row*
1 - 2 1 - 4 1 1 - 2 2 1 - 4
4 - 6 7 - 12 4 7 - 8 5 9 - 10 6 11 - 12 x1
8 - 10 15 - 20 8 15 - 16 9 17 - 18 10 19 - 20 x2
12 - 14 23 - 28 12 23 - 24 13 25 - 26 14 27 - 28 x3
16 - 18 31 - 36 16 31 - 32 17 33 - 34 18 35 - 36 x4
20 - 22 39 - 44 20 39 - 40 21 41 - 42 22 43 - 44 x5
24 - 26 47 - 52 24 47 - 48 25 49 - 50 26 51 - 52 x6 x1
28 - 30 55 - 60 28 55 - 56 29 57 - 58 30 59 - 60 x7
32 - 34 63 - 68 32 63 - 64 33 65 - 66 34 67 - 68 x8 x1
36 - 38 71 - 76 36 71 - 72 37 73 - 74 38 75 - 76 x9
40 - 47 79 - 84 40 79 - 80 41 81 - 82 42 83 - 84 x10 x1
44 - 46 87 - 92 44 87 - 88 45 89 - 90 46 91 - 92 x11
M251021A-. M251022A-. M251023A-. M251021P3 51021DN 51021CF-. +
Row*
x1 x1 x1
Single Double Single Double Single Double
Audio Module
* Optional to install rain hood
Pushbutton Module
&
Nameplate Module
4-row pushbutton
Article No.
Cover Frame & Flush Mounted Box
41021F
51022CF-. + 41022F
51021RH 51022RH 51023RH 51024RH 51028RH 51025RH 51026RH 51029RH 51027RH
51023CF-. + 41023F
51024CF-. + 41024F
51028CF-. + 41028F
51025CF-. + 41025F
51026CF-. + 41026F
51029CF-. + 41029F
51024CF-. + 41024F + 51021J
4-row pushbutton
Button Range
Single Row*
1 - 2 1 - 4 1 1 - 2 2 1 - 4
4 - 6 7 - 12 4 7 - 8 5 9 - 10 6 11 - 12 x1
8 - 10 15 - 20 8 15 - 16 9 17 - 18 10 19 - 20 x2
12 - 14 23 - 28 12 23 - 24 13 25 - 26 14 27 - 28 x3
16 - 18 31 - 36 16 31 - 32 17 33 - 34 18 35 - 36 x4
20 - 22 39 - 44 20 39 - 40 21 41 - 42 22 43 - 44 x5 x1
24 - 26 47 - 52 24 47 - 48 25 49 - 50 26 51 - 52 x6
28 - 30 55 - 60 28 55 - 56 29 57 - 58 30 59 - 60 x7 x1
32 - 34 63 - 68 32 63 - 64 33 65 - 66 34 67 - 68 x8
36 - 38 71 - 76 36 71 - 72 37 73 - 74 38 75 - 76 x9 x1
40 - 42 79 - 84 40 79 - 80 41 81 - 82 42 83 - 84 x10
Double Row*
Camera Module
M251021C
M251021A-. M251022A-. M251023A-. M251021P3 51021DN 51022CF-. +
x1 x1 x1 x1
Single Double Single Double Single Double
Audio Module
* Optional to install rain hood
Pushbutton Module
&
Nameplate Module
Article No.
Cover Frame & Flush Mounted Box
41022F
51023CF-. + 41023F
51022RH 51023RH 51024RH 51028RH 51025RH 51026RH 51029RH 51027RH
51024CF-. + 41024F
51028CF-. + 41028F
51025CF-. + 41025F
51026CF-. + 41026F
51029CF-. + 41029F
51024CF-. + 41024F + 51021J
26 | ABB-Welcome
ABB-Welcome | 27
Page 15
02 Planning Outdoor station selection
Fig.17
Keypad with pure audio module outdoor station
Fig.18
Keypad and display (in-built RFID reader )with pure audio module outdoor station
Options of keypad outdoor station
For condominium buildings and residential complexes, it is recommended to choose keypad outdoor station.
Keypad with pure audio module outdoor station
Fig.17
Besides the keyless access by inputting the correct password, it can also be used for inputting the correct call code to call the indoor stations.
The call code is default starting from 1, which will call the indoor station with the address of 1.
Keypad and display (in-built RFID reader) with pure audio module outdoor station
Fig.18
The display with in-built ID/IC reader can be used for multiple uses: keyless access by reading the registered proximity card, displaying some welcome messages, showing the status of calling progress, or processing the programming. Upon programming, the name or call code can also be displayed on the screen and scrolled up and down on the keypad module.
The call code is default starting from 1, which will call the indoor station with the address of 1.
Keypad with the pushbutton outdoor station
Fig.19
Keypad provides the keyless access for the residents of the building by inputting the correct password.
It is a good solution especially for the single family home solution. Then the pushbutton is largely for visitors only.
Display(in-built RF reader) with the pushbutton outdoor station
Fig.20
ID/IC proximity reader can be useful also for residents' keyless access by reading the registered proximity card. In case lost, it can also be easily wiped out in the system and a new card can be efficiently registered. Then the push button is largely for visitors only.
Keypad and display(in-built RF reader) with pushbutton outdoor station
Fig.21
It is the combination of keypad outdoor station and push button outdoor station. It provides the most convenient calling experience for the residents and the visitors. For the residents, he can input the correct password or swipe the registered proximity card. He can also press the push button or scroll up and down the screen and press call button in case the resident's name is stored there.
Fig.19
Keypad with pushbutton outdoor station
Fig.20
Display (in-built RFID reader) with pushbutton outdoor station
28 | ABB-Welcome
Fig.21
Keypad and display (in-built RFID reader) with pushbutton outdoor station
ABB-Welcome | 29
Page 16
02 Planning Outdoor station selection
2.3 Selection of the indoor station
In addition to the appearance, to select the indoor station for application needs to consider the functions needed for the project. The table below gives a general function list for the indoor station for application.
Functions 7" all touch video hands-free
indoor station
* Secret conversation x x x x
* Cyclical surveillance x x x -
* Manual call x x x -
* Door bell call x x x x
* Remote unlock x x x x
* Control two locks x x x x
* Room to room call x x x x
* Home to home call x x x x
* Paging/Broadcast - x x -
* Black list x x x -
* Call guard unit x x x x
* SOS x x x x
* Image saving x x x -
* Customized audio message
leaving
* Call forward x x x -
* Door status check x x x x
Variable ringtone x x x x
Customized password for keypad x x x -
* Picture frame and screen saver x - - -
* Automatic unlock x x x x
* QR code for user manual reach x x x -
* Mute one or mute all x x x - only mute itself
* Induction loop - x x x
Local power supply - x x -
Surface mounted installation x x x x
Desktop installation x x x -
Flush-mounted installation - x - -
x - - -
4.3" video hands-free
indoor station
** 4.3" video handset
indoor station
Audio handset
indoor station
Secret conversation
Fig.22
During the conversation between the outdoor station and the indoor station, all outdoor stations and indoors that are not involved in the conversation are temporarily excluded in order to guarantee the privacy of video door entry conversations. When calling from an outdoor station that is temporarily excluded, a time-out will indicate that the extension line is momentarily busy.
Cyclical surveillance
Fig.23
All indoor stations are equipped with a surveillance button which can be used to connect the outdoor stations at any time. The user sees the images from the default outdoor station; press repeatedly the button to display images from the additional camera (if present) connected to the default outdoor station, and then from other outdoor stations.
Fig.22
Secret conversation
Fig.23
Cyclical surveillance Door bell call
Manual call
Fig.24
During surveillance, by picking the handset up or activating audio in case of hands-free stations, the user starts a conversation with the selected call station.
Door bell call
Fig.25
Indoor stations are provided with two terminal pins used to connect the door bell button. If the button is pressed, the indoor station emits an about 3s ring, according to the selected call ring tone (different from those of the other calls). If the user has several indoor stations in parallel, and connect this button only to one indoor station, all indoor stations will ring together.
Fig.24
Manual call
Fig.25
Notes: * For the function description, please find the explanation in the following pages.
30 | ABB-Welcome
ABB-Welcome | 31
Page 17
BLACKLIST
BLACKLIST 1
Add New
02 Planning Outdoor station selection
Fig.28
Room to room call
Home to home call
Remote unlock
Fig.26
With the system at reset, the user can open the lock of the default outdoor station at any time. If during conversation, the user can release the door lock associated to the outdoor station making the call .
Control two locks
Fig.27
Two locks can be connected with outdoor station, one is for pedestrian gate and the other is for driveway gate. User can press "unlock" button and programmable button (e.g. button 1, release 2ndlock function is programmed first) to control the two doors respectively.
Room to room call&Home to home call
Fig.28
If there are several indoor stations in parallel, after programming an indoor station for internal intercom function, user can activate the intercom call at this indoor station, all other indoor stations will ring together.
For several different apartments, after programming an indoor station for external intercom function, user can activate the intercom call at this indoor station, the called indoor station will ring.
Paging/Broadcast
Fig.29
User can activate the broadcast function by entering broadcast menu, a message can be forwarded through all IS in the same apartment.
Blacklist
Fig.30
To be safe, for home to home call the unwanted caller can be set in blacklist.
Call guard unit
Fig.31
This function allows establishing a communication with the guard unit. Enter communication menu to send the call to the guard unit or press a programmable button (call guard unit function is programmed first ) to activate the call.
Send SOS
Fig.32
If there is emergency, user can send an SOS message to guard unit by pressing programmable button 1 for 3s. Guard unit will receive the SOS message and indicates which apartment is sending SOS.
Image saving
Fig.33
Users can find who has recently been at the door and what happened to him by history menu. Either manual snapshots during conversation or automatic snapshots after bell ringing in your absence will be saved in history.
Customized audio message leaving
Fig.34
Before going out you can record an audio message for a family member or visitors who ring the bell.
Fig.29 Fig.30
Paging/Broadcast
……
Fig.31
Call guard unit
Blacklist
Fig.32
Send SOS
(001)
SOS
>3s
Fig.26
Remote control
Remote unlock at any time for default outdoor station
32 | ABB-Welcome
Fig.27
Control 1st and 2nd locks
Fig.33 Fig.34
Image saving Customized audio message leaving
HIS TORY
=
Date-Time Direction 2013-03-22 01:05 2013-03-22 Out door-1 01:12 2013-03-22 Out door-1 01:15
ABB-Welcome | 33
Page 18
02 Planning Outdoor station selection
Fig.35
Call forward
Fig.36
Door status check
Call forward
Fig.35
It is possible to forward the income calling when absent from home. Through the setting at indoor station before leaving home, the incoming call can be forwarded from home to the selected neighbor or the guard unit.
Door status check
Fig.36
A sensor is connected with outdoor station, if this door is open for over 120s, LED of unlock button of indoor stations and guard units will flash. When the door is closed, the LED will be off. If 2 or more outdoor stations are associated, the LED will be off when all outdoor stations are closed and will flash when at least one outdoor station is open.
Variable ringtone
Users can select the ring tone for default outdoor station or other outdoor stations or the door bell ring tone among the 5 available ones.
Customized password for keypad
Users can set a private password (6-8 digits) at indoor station just at home, which is easy to remember.
Picture frame and screen saver
Fig.37
When the indoor station is at standby, its appearance will add the decor of the room. With a SD card the indoor station can display high-resolution files from the computer or camera directly on the touch display. The display time can be adjusted optionally.
Automatic unlock
Fig.38
This function is used mainly in the service sector (offices, doctors, professional). This feature can be activated or deactivated at the indoor station. With the function activated, LED unlock will light, and after receiving a call, unlock command will be sent automatically.
QR code for user manual reach
Fig.39
Users can scan QR-Code contained in the menu of video indoor stations directly to get the detailed manual. While for audio indoor station, QR-Code is contained in the quick guide.
Mute one / mute all indoor station
Fig.40
User can mute the ringtone when there's an incoming call. Press the mute button to mute the indoor station. If the user has several indoor stations in parallel, long-press the mute button for about 3s at one indoor station, and all indoor stations will mute together when there's an incoming call. When the function is activated, the LED MUTE turns on.
Induction loop
Fig.41
Indoor station with an induction loop allows hearing-impaired persons to wear a hearing aid (working in "T" mode) to hear the ringtone and the voice of visitors.
Local power supply
Indoor station can be powered by an additional power supply when a parallel indoor station needs to be installed without impact on the whole system.
5s 5s
Fig.37
Picture frame and screen saver
Fig.39
QR code for user manual reach
Fig.38
Automatic unlock
A
I
Fig.40
Mute one and mute all
=
AUTO UNLOCK
Auto Unlock
Time 1T ime 2
08 : 00 00 : 00
12 : 00 00 : 00
Disable cfoarlwla rd
120s
8:00 - 12:00
34 | ABB-Welcome
Fig.41
Induction loop for hearing aid
ABB-Welcome | 35
Page 19
02 Planning System device selection
2.4 Selection of system devices
It’s important to select the appropriate system devices to set up a Welcome system. Both function of the devices and topology for the application needs to be considered. System controller is a must for any insulated system; other system devices can be selected to meet the specific project requirement.
Fig.42
Application of system controller, local power supply and auxiliary power supply
System controller, local power supply and auxiliary power supply
System controller provides both power and communication command for a Welcome system. An extension of the system controller, auxiliary power supply and local power supply serve as the supplement to provide a flexible power solution to meet the requirement of all kinds of Welcome system. The illustration shown is a project case using three power sources.
Fig.42
System controller
Working as the "brain“ of all devices, a system controller is compulsory and exclusive in any insulated system. It not only provides power, but also manages all the communication and control between outdoor stations and indoor stations in the building part,and between gate stations and the gateway in the common part.
For those systems with multi-system illustration shown be broken down into several insulated systems and every insulated system needs separate power consumption and distance limit calculation.
Both standard system controllers and mini system controllers are provided to meet different project needs.
The system controller has two working modes: “all on” and “one on”, "all on" and "one on" are system behavior for screen switching on for the indoor stations with the same address (parallel indoor stations) in case of being called. Under "all on", the master video indoor station and other slave video indoor station(s) will all switch on the screens and ring at the same time upon being called from the outdoor stations or gate stations. Under "one on", only the "master" video indoor station will switch on the screen and ring, the other "slave" video indoor station(s) will ring but will not switch on the screen.
Fig.43
Power units of system controller
As system controller will provide the power for the system, it is important to calculate the available power unit of standard system controller or mini system controller for the system before application.
For a 2-wire system, the available power unit of a system controller needs to take the situation of 1 or ≥2 apartments into consideration firstly.
To achieve a comfortable door communication experience in applications, different value of working power will always be reserved first to handle the simultaneous working of different devices(door call, setting, door bell) before allocated to the standby devices.
Since the power calculation is based on the remaining standby current after subtracting the varied reserved working current in 1 or ≥2 apartments, thus, the power units of system controller varies when the system contains 1 or ≥2 apartments, which has been revealed in Table 1 (page 62 ).
Moreover, the "all on" and "one on" mode setting will impact the power consumer calculation when one apartment contains more than one video indoor station(parallel indoor stations). As we can see from the power and distance table in Table 1 on page 62, for one additional video 4.3" indoor station when the system controller is under "all on" mode, 23 more consumer units should be counted, while only 11 consumer units are counted when system controller is under "one on" mode. In the real project, the balance can be made between cost and comfort.
Auxiliary power supply
Auxiliary power supply
System controller
Fig.43
“All on” and “One on” setting of system controller
Master
Local power supply
Slave
Slave
36 | ABB-Welcome
All on
One on
Master
Slave
Slave
ABB-Welcome | 37
Page 20
02 Planning System device selection
Fig.44
Local power supply for parallel indoor stations
Local power supply
Local power supply and system controller are exactly the same devices, but they are named differently because of the different functions they serve.
»
Local power supply only provides the pure power source without giving communication commands like the system controller.
»
Unlike the system controller or auxiliary power supply that provides the power for all the devices in the external and internal bus line through the 2-wire bus terminal, local power supply provides the pure power to individual
devices directly by connecting the local power supply terminals.
»
Devices below contain local power supply terminals, and
can be powered by local power supply:
»
Audio module of outdoor station
»
4.3” video handset/hands-free indoor station
»
Guard unit
Despite the physical product is like system controller, the working mode setting of local power supply is useless .
Power units of local power supply
One mini local power supply can feed
»
Up to 4 pcs of parallel 4.3" video hands-free indoor station
»
Up to 4 pcs of parallel 4.3" video handset indoor station
»
Up to 4 pcs of parallel guard units
»
1 pc of any kind of pushbutton outdoor station
»
1 pc of any kind of keypad outdoor station
Even though one standard local power supply doubles the capacity compared to one mini local power supply, the user will not need it.
The increased number of devices can be the increased quantities of apartments in one building or the increased quantities of parallel indoor stations within one apartment.
Based on the calculation rule in Table 1 (page 62), specifically, for scenarios below when the power units of one system controller is smaller than required consumer units of devices, local power supply is highly recommended. This is due to the fact that compared to auxiliary power supply, local power supply solution will be less cost and easier wiring:
»
When the total consumer units of external and internal bus > power unit of system controller, while the total consumer units of the devices on internal bus ≤ power unit of system controller, one or all outdoor stations should be powered by local power supply.
»
When feeding the local power supply to parallel slave 4.3"
video hands-free or 4.3" video handset indoor station(s), the total power consumer units will become≤power units of system controller.
»
When feeding the local power supply to guard unit, the
total power consumer units will become ≤power units of system controller.
»
When adding the parallel 4.3" video hands-free or 4.3"
Fig.45
video handset indoor station to an apartment after the door communication system installation had been finished in the past. Since the additional device might cause the system controller to inadequately cover the increased consumer units, it is safe to put local power supply to additional 4.3" indoor station to that certain apartment without affecting the existing power solution.
Fig.46
Fig.45
Feed parallel 4.3” video indoor stations by mini local power supply
Note:
1. Standard system controller “all on” mode, supports 1 outdoor station + 5 parallel 4.3” video hands-free indoor stations
2. Mini local power supply, feeds 4pcs 4.3 video hands-free indoor stations
Note:
1. Standard system controller “all on” mode, supports 1 outdoor station + 3 parallel 7” video hands-free indoor stations
2. Mini local power supply, feeds 4pcs 4.3 video hands-free indoor stations
For parallel 4.3” video indoor stations in one apartment, the screen of any one fed by local power supply will always be on for incoming calls,even in “one on” setting in system controller.
Fig.44
When the device is fed by local power supply, it requires rather small power consumer unit from the system controller. Which is shown in Table 1 on page 62. The saved power of system controller can be used to increase the number of devices under this system controller.
Fig.46
Add parallel 4.3” video indoor stations to apartments after installation
Note: In 2013, the door entry system for this building had been installed. Later on, Apartment A, B and/or C can also equire to add one more video indoor station with local power supply without affecting other users.
38 | ABB-Welcome
ABB-Welcome | 39
Page 21
02 Planning System device selection
Auxiliary power supply
For one insulated system, when adding the local power supply to the devices in external bus or internal bus, if both ways still cannot cover the required consumption units of the devices, auxiliary power supply is suggested. The combination of gateway (under auxiliary power supply mode) and system controller will make an auxiliary, which can be used to split the system into two insulated systems.
Fig.47
Like system controller, the "all on" and "one on" mode setting will impact the power consumption calculation in parallel indoor stations.
Power units of auxiliary power supply
The Table 1-2 on page 63 can be used to count devices powered by auxiliary power supply. To have an easy reference please check Table 3-2, Table 3-3 and Table 3-4 on page 77-78, the capacity of both mini auxiliary power supply and standard auxiliary power supply are counted in.
Gateway
For the system with multi-system controllers, gateway is needed to make each insulated system(managed by one system controller) interact with devices installed in the common part.
Gateway offers high level flexibility for application with 5 different working modes. The modes of gateway can be set as below:
» Building gateway » Floor gateway » Apartment gateway » Auxiliary power supply » Line amplifier
For the setting of the working mode of gateway, please refer to page 98 in Chart 04.
Building gateway mode
Building gateway is mainly applied to building systems, which enables one building to be an independent sub insulated system within a residential complex. Each building supports up to 250 apartments.
Fig.48
Or it can be used for a building with more than 250 apartments by making 2 insulated building systems for this building.
Fig.49
It supports 60 such system for application. The address of building gateway should be set one upon another in sequence from 1 to 60.
Fig.47
Auxiliary power supply
System controller + gateway (auxiliary power supply mode)
Fig.48
Building gateway application for building systems within a
residential complex
Fig.49
Building gateway application for high-rise building with more than
250 apartments
63 apartments
63 apartments
Building gateway mode
63 apartments
Commissioning as gate station
40 | ABB-Welcome
ABB-Welcome | 41
Page 22
Floor gateway mode
Floor gateway is mainly applied to floor systems, which enables a floor outdoor station and multi-apartments on the same floor to be an independent sub insulated system within the building.
Fig.50
02 Planning System device selection
Fig.51
Floor gateway application for small residential complex
Apartment 01 A
Apartment 02 B
Apartment 01 A
Apartment 02 B
Apartment 03 C
Apartment 03 C
Apartment 04 D
Apartment 05 E
Apartment 06 F
Apartment 04 A
Apartment 05 B
Apartment 06 C
Also it can be used for a small residential complex that uses pushbutton outdoor station as gate station.
Fig.51
The starting address of one floor gateway should be minimal address of indoor station of this floor. But the available address number for floor gateway is 99. Please refer to page 99 for commissioning of gateway.
Fig.50
Floor gateway application for floor systems within the building
Outdoor station Left building
Outdoor station Gate entrance
Outdoor station Right building
42 | ABB-Welcome
building 1
ST. X100 X10 X1
2 0 0 3
ST. X100 X10 X1
2 0 0 2
ST. X100 X10 X1
2 0 0 1
Address
2
Apartment 01 A
Apartment 02 B
Apartment 03 C
Outdoor station Left building
Address
1
Apartment 01 A
Apartment 02 B
Apartment 03 C
Apartment 04 D
Apartment 05 E
Apartment 06 F
Outdoor station Gate entrance
Address3ST. X100 X10 X1
Apartment 04 A
Apartment 05 B
Apartment 06 C
Outdoor station Right building
3 0 0 4
ST. X100 X10 X1
3 0 0 5
ST. X100 X10 X1
3 0 0 6
ABB-Welcome | 43
Page 23
02 Planning System device selection
Fig.52
Apartment gateway application
1. For apartment systems within the building
2. For a group of villa that networked
Apartment gateway mode
Fig.52
Apartment gateway is mainly applied to apartment systems, which enable an apartment with a second confirmed outdoor station to be an independent sub insulated system within the building.
Also it can be used for the application of a group of villas/ single family houses in a residential complex. It supports 99 such systems for application. The address of apartment gateway should be set one upon another in sequence from 1 to 99.
Auxiliary power supply mode
The system controller must combine the gateway set as auxiliary power supply mode to feed the system with extra power. The additional system controller is used to split the system into two insulated systems.
There is no need to set address for auxiliary power supply.
Line amplifier mode
Line amplifier is used to extend the distance of signal when it is not enough. The distance extended by one amplifier will vary according to cable type.
Please refer to page 64 Table 2-3 for the distance calculation. The position to install the amplifier is recommended at the end of the maximum distance of the cable.
Fig.53
Example: A project of a residential complex with 10 buildings, looped through with 10 building gateways, whose wiring distance from gate station to last building is 300m, cable RVV, Ø=1mm is used.
User case analysis: The attenuation units of the 10 building gateways are 15 units (1.5 unit x10). If with cable RVV, Ø=1mm, according to the Table 2-3, the max. distance can be counted as 170m, which is <300m.
Solution: One gateway in amplifier mode is needed to split into section A and section B.
Fig.53
Line amplifier application
Gateway address
Actual distance
Solution:
Reference table:
1st 2nd 3rd 4th 5th 6th 7th 8th 9th 10th
30m 60m 90m 120m 150m 180m 210m 240m 270m 300m Section A is from gate station
to 5th building, the attenuation unit is 7.5 unit (1.5 unit x 5),the max. distance is 180m, ≥ the real distance 150m
Table 2-3 Table 2-3
Section B is from 5th building to 10th building, the attenuation unit is 7.5 unit (1.5 unit x 5), the max. distance is 180 m, ≥ the real distance 150m
So the solution is to install the gateway as line amplifier mode at 6th building for maximum use of cable.
There is no need to set address for line amplifier.
44 | ABB-Welcome
ABB-Welcome | 45
Page 24
02 Planning System device selection
Fig.55
Power consumption units of gateway
Maximum quantity limitation of gateway pass through to an apartment
Noted: a maximum of 4 gateways can be passed through to any apartment, regardless of the mode of gateway, except this combination:building gateway + floor gateway + apartment gateway. (The looping of gateway is not counted)
For example, for building n
Fig.54
» For floor 1 and floor 2, total 3 gateways » For floor 10, up to 4 gateways, which is the maximum
For each building, a maximum of 2 gateways for each apartment is allowed, either building gateway + floor gateway, building gateway + apartment gateway, or floor gateway + apartment gateway. It is not allowed building gateway + floor gateway + apartment gateway. So for floor 10, it is not allowed to have apartment gateway.
Power consumption units of gateway
For gateway except when it is set as line amplifier mode, the consumption unit is divided into two parts: the one provided by the internal bus of system controller of one insulated system , and the other part provided by the external bus of system controller of the sub insulated system (if any).
Fig.55
When set as line amplifier mode, the power consumption is provided independently by the system controller that controls it.
Please refer to page 62 for Table 1-1 of power consumption and distance calculation. The power consumption need to be calculated distinctively by the mode:
» When it is set as building gateway, floor gateway, apartment
gateway and auxiliary power supply mode, the total consumption is 7 units, with 2 units (C1) from internal bus of system controller of the insulated system and 5 units (C2) from external bus of system controller from system controller of the other connected insulated system.
» When it is set as line amplifier mode, the consumption unit
is 5 from the system controller that controls it.
Attenuation unit of gateway
For looping through of one gateway regardless of the mode,
1.5 attenuation unit will be consumed.
C2=5 units
C1=2 units
Fig.54
Maximum gateways passed through to apartments
Building 1 Building 2
Building n
46 | ABB-Welcome
ABB-Welcome | 47
Page 25
02 Planning System device selection
Fig.57
1. 1 level cascading connection for 2 outdoor stations with outdoor distributor
2. 2 level cascading connection for 3 outdoor stations with outdoor distributor
Switch actuator
Fig.56
As the function implementation device of the indoor station or outdoor station or guard unit, switch actuator can be installed in the internal bus or external bus in both building part and common part. Different modes can be set to realize different functions.
» If installing within the apartment, it can be used to extend
the call to a bell or a light (switch on for a period of time when it is called). The address of the switch actuator and the indoor station should be configured to be the same. This is called "Call repetition mode".
Fig.56-1
» If installing the switch actuator in the common part to
connect a lock or a light, it can be controlled by any indoor station, guard unit or outdoor station in the whole system. If installing it within a building, only the devices of the given building can control it. For all these scenarios:
» If the "unlock" button of indoor station or guard unit
controls the connected lock, the switch actuator address should be set as the address of outdoor station which the lock is associated with. This is called "Door opener mode".
Fig.56-2
» If the lock or light will be controlled by the programmable
button of indoor station ,guard unit or outdoor station, the mapping of the switch actuator address and the programmable button address should be configured. This is called "Time relay mode".
Fig.56-3
Outdoor distributor
Fig.57
As a video signal switching device in the external bus, outdoor station distributor should be used when more than one outdoor station or one gate station is present in a given project while at least one of the outdoor stations is video. If pure multiple audio outdoor stations are the case, the node connection is enough without the need of video outdoor distributor.
Each outdoor station distributor can connect 2 outdoor stations. The cascaded connection is also possible from outdoor station distributor to next level outdoor station distributors. As a passive device, it consumes no power, but the video signal drops a lot (15 attenuation units), thus as less level as possible of the video outdoor distributor should be achieved to have less signal attenuation for a given line.
2 level cascading connection for 4 outdoor stations with outdoor distributor
3 level cascading connection for 8 outdoor stations with outdoor distributor
The local power source should be provided to the connected lock or light, as the switch actuator only provides a dry contact.
Fig.56
1. Call repetition mode
2. Door opener mode 3. Time relay mode
48 | ABB-Welcome
ABB-Welcome | 49
Page 26
02 Planning System device selection
Fig.59
Use one auxiliary power supply in common part
Video distributor
As a video signal branching device in the internal bus, video distributors should be used when star connection is needed for the apartments in the building part and for the gateways in the common part. For the audio system, the video distributor is not needed in the building part and the common part.
Fig.58
Each video distributor can connect up to 4 apartments or 4 lines in the building part and 4 gateways in the common part. The cascaded connection is also possible. The impact of the distance can be reviewed from the distance calculation in Table 2 on page 64.
When video distributor is used in the common part, the total distance of all the lines branched by the video distributor under one system controller should be less than 800meters. Auxiliary power supply can be used to split the whole distance into several sections, which can ensure each section meet the 800 meters distance limit with one system controller. The distance constraint from different cables should also be considered, please check page 64 to view the details.
Fig.59
Guard unit
As the management interface, the desk-top supported guard unit in the 4.3" touch screen can interact with gate stations, outdoor stations, indoor stations and even the other guard units efficiently. PC or laptop can also be connected to edit the resident information efficiently by a universal USB cable.
Fig.60
For security concern, guard unit can act as a panic reception center, receiving the emergency call from any indoor station by activating the “SOS" signal. What is more, the interception in day/night mode can be set with customized timeline and receivers(for all or just VIPs), the call will be directed to the guard unit for monitoring purpose when the visitor call the resident directly from the gate/outdoor station. Finally, when the outdoor station or gate station 's "call guard" function is activated, for example by a one-button video gate station, the operator in the guard unit will intercede all the calls from the visitors and transfer the filtered call to the dedicated indoor station.
Fig.61
Fig.60
Connect guard unit and PC or laptop by USB cable
Fig.58
Star sharp connection in common part by distributors
Fig.61
Interception function of guard unit
50 | ABB-Welcome
ABB-Welcome | 51
Page 27
IP-Gateway
IP-Gateway enables ComfortTouch or smartphone and tablet ( iOS and Andriod ) with installed Welcome app as a video indoor station. It supports user to establish the call from vistors, control doors or switch on lights by WIFI or remote access under 3G/4G with the help of server provider. Also IP-Gateway is a configure interface for other Welcome products, like telephone gateway.
Fig.62
Up to 4 terminal devices (including comfort touch & tablet & smartphone) can be connected with one IP-Gateway. For the setup and use of the terminal devices with IP-Gateway, the following is required:
1. Register and logging into ABB portal. Get your own user account from the server.
2. Connect the IP-Gateway to ABB portal. Configure the IP-Gateway by PC, when this PC and IP-Gateway are connected to the same network by one router. Enter your own user account by “Portal Login” menu.
3. Install the APP on the terminal devices, and login by your own user account.
4. Coupling the IP-Gateway and terminal devices.
Fig.62
ComfortTouch and smartphone and
tablet (iOS and Andriod) with installed
Welcome app
02 Planning System topology
2.5 System topology
For any insulated system, there are 2 kinds of connection to make the topology – loop through connection and branch connection (node branch or branch with video distributor). In actual project there will be more than one topology for the same.
Topology of the external bus
For external bus, if there is more than one outdoor station or system devices in the insulated system, things should be considered to make the topology.
» For audio system, if there is more than one outdoor
station,the outdoor station can be looping through the device or node branch.
» For video system, if there is more than one outdoor station
(audio/video), the outdoor video distributor is needed for a cascading connection for parallel outdoor station. By cascading connection, the distance calculation for external bus line is between the longest parallel outdoor station and system controller, rather the total of the distance of each parallel outdoor station.
Fig.63
Fig.64
Fig.62
Smartphone and tablet (iOS and Andriod)
with installed Welcome app
52 | ABB-Welcome
Fig.63
Topology audio outdoor stations in a audio system
Loop though of outdoor station in audio system
Node branch of outdoor station in audio system
ABB-Welcome | 53
Page 28
Fig.64
Topology video outdoor stations in a video system
3 level cascading connection for 8 outdoor stations with outdoor distributor
02 Planning System topology
Topology of the internal bus
For internal bus, the RC rule is needed to be considered when making the topology. Below things need to be taken into consideration when making the topology.
Scope of distance calculation for external bus
Topology
Looping through the indoor station
Looping through the node(branch line/stub line)
looping through the video distributor(branch line/stub line)
looping through the gateway
RC rule if in audio system
RC=OFF in all the devices
Fig.65
RC=OFF in all the devices
Fig.67
RC=OFF in all the devices
RC=OFF in all the devices
Fig.69
RC rule if in video system
RC=ON in the last device RC=OFF in all other devices
Fig.66
-
RC=ON in the last device of each stub line and at the end of the riser main and RC=OFF in all other devices
Fig.68
RC=ON in the last device RC=OFF in all other devices
Fig.70
Can be used in building part?
YES
YES
YES
YES
Can be used in common part?
NO
NO
YES
YES
Advantage to use Caution to make
- Good for low rise building and parallel indoor stations
- Future proof even upgrading from audio system into video system
- Cost and power effective without video distributor
- When the BUS terminals of one indoor station which is in the middle of building is not well fixed, the rest of the indoor stations will not work
- The diameter of the cable is recommended no less than Ø=0.6mm
- Flexible wiring, "star shaped" is allowed
- Cost effective for audio system, no distributor is
Each node should be changed into video distributor if upgrading into video system
needed
- It will have longer distance compared to looping the same quantity of gateway or indoor station, especially when parallel indoor stations are looped within the apartment
- When one of the branch does not work, it will not
The total cable length should be less than 800 meters, this might not be enough in a big residential complex. Auxiliary power supply can be used to split the common part from one system controller into several system controllers
impact the others
- Allow the parallel bus lines
Long distance when the looping quantities are less(for example≤8),which is good for residential complex
When as building gateway in the residential complex, the distance will not be long enough when with many looping quantities
Remarks: In the real world, the combination of different topologies will be used to maximize the advantage while to avoid the constraint of each topology.
Fig.71 Fig.72 Fig.73
See for RC rule.
Fig.65
Fig.66
Looping through the indoor station in audio system Looping through the indoor station in video system
54 | ABB-Welcome
ABB-Welcome | 55
Page 29
Fig.67
Looping through the node(branch line/stub line)
02 Planning System topology
Fig.69 Fig.70
Looping through the gateway in audio system Looping through the gateway in video system
Fig.68
Looping through the distributor (branch line/stub line)
RC-OFF RC-OFF RC-OFF RC-OF F
Fig.71
In audio system Looping through the video distributor with each distributor branching into 4 lines . The terminal resistor must be set as “OFF”, to all the gateway and distributor
RC-OFF RC-OFF RC-O NRC-OFF
56 | ABB-Welcome
Fig.72
In video system Looping through the video distributor with each distributor branching into 4 lines. The terminal resistor must be set as "ON" on the last gateway each stub line and at the end of last distributor
ABB-Welcome | 57
Page 30
Fig.73
Looping through gateway as auxiliary power supply. Each distributor is connected to branching into 4 lines. Each line looping through the building gateway.
Topology for some special application
Welcome is a flexible system for many special applications. For some cases, by allocating all the devices in a certain topology will conquer the limitation such as the power consumer and distance.
For example, for a big villa, more than 1 video outdoor stations are needed, more than 4pcs 7” video indoor stations are required, and dedicated intercom (one room can call the dedicated room, while all the rest keep idle), then the topology can be made as the illustration.
Fig.74
In some cases, for example the pushbutton modules of outdoor station need to be installed at a lower place for wheelchair users, or be installed separately with audio outdoor station for renovation from audio system to video system, it can make topology like the illustration.
Fig.75
02 Planning System topology
But it must be noted that the maximum distance of the cable from camera modules to audio module is only 10 m.
58 | ABB-Welcome
ABB-Welcome | 59
Page 31
Fig.74
Topology of a big villa with 12 7” hands-free indoor stations
02 Planning Power consumer and distance calculation
Dedicated intercom
Customized name as living room
Auxiliary power supply mode Addressing is unnecessary
Apartment Gateway mode
Remarks: Special software should be supplied for both gateway and 7”, please contact your installer for this application
Fig.75
Auxiliary power supply mode Addressing is unnecessary
Special application of camera module
Customized name as kitchen
Auxiliary power supply mode Addressing is unnecessary
2.6 Power consumer and distance calculation to an insulated system of Welcome system
The set up of a Welcome system needs to calculate both the power consumer and distance. Based on the table 1 and table 2, installers can make plans for any kind of projects by following the process below:
Fig.76
Process of power consumer and distance calculation
60 | ABB-Welcome
3pairs 2-wire bus together Max: 10 metres
ABB-Welcome | 61
Page 32
Table 1-1: Power consumer calculation& attenuation unit (system controller)
Note: All below consumer and distance calculation is based on each insulated system
Device
Number( n ) Consumer
Unit ( c )
n x c n x aAttenuation
Unit( a )
Distance based on cable selected(m)--Check Table 2
External Bus--Outdoor Station
Camera module Audio module(0/1/2-row button) Push button module(3-row or 4-row) Keypad module Display module(ID or IC) Nameplate module
6 or 0* 14 or 0* 1 or 0* 2 or 0* 20 or 0* 1 or 0*
-
-
-
-
-
-
External Bus--System device
Outdoor distributor Gateway Gateway (line amplified mode) Switch actuator Guard Unit
**
­5 5 6 15 or 0*
15
-
­1 1
Total consumer units for external bus
Internal Bus-Indoor Station
Audio handset--- (no additional consumer unit for
1
-
parallel indoor stations in audio system)
4.3" handset & hands-free--(additional consumer unit should be counted in parallel indoor stations)
7" hands-free--(additional consumer unit should be counted in parallel indoor stations)
1
17
1 or 0***
1 or 0***
Additional consumer unit in case parallel 4.3" indoor stations or 4.3' and audio in video system(Only consider the apartment with max. parallel indoor stations), the system controller is set as "one on"
Fig.77
11 or 0*
1
Additional consumer unit in case parallel 4.3" indoor stations or 4.3' and audio in video system(Only consider the apartment with max. parallel indoor
23 or 0*
1
stations), the system controller is set as "all on" Additional consumer unit in case parallel 7" indoor
stations or 7" and 4.3" or 7" and audio in video system(Only consider the apartment with max.
17
1
parallel indoor stations)
Internal Bus-System Device
Guard Unit Gateway Gateway (line amplified mode) Video distributor Switch actuator IP-Gateway
15 or 0* 2 5 1 6 17
Total consumer units for internal bus
Total consumer units
1
1.5
­2 1 1
Total attenuation units
B= (max. distance from system controller to the furthest indoor staion)
A= (max. distance from outdoor station to the furthest indoor station)
The total consumer units should be less than below power unit whose value varies in 1 or >=2 apartments building >=2 apartments 1 apartment One standard system controller in audio&video system,Total conumer units <=96 <=127 One mini system controller in audio system, Total consumer units <=60 <=72 One mini system controller in video system, Total consumer units <=27 <=58
Note: * When the device is powered by local power supply, the value of consumer unit=0. See example.3 for its application. ** The number counted for the attenuation will base on how many levels so to achieve the least attenuation. For example 4 outdoor stations, 3 outdoor distributors, but 2 levels
is counted. Check page 54 for the levels.
*** When looping through the indoor station, the attenuation unit=1, and when the indoor station is branched from the distributor, the attenuation=0
02 Planning Power consumer and distance calculation
If one system controller or even by the provision of local power supply is not enough to feed all the devices, auxiliary power supply can be uselationat Please be informed that the power unit for system controller and auxiliary power supply are the result of different formula, even the same value is made to have easy memory.
Table 1-2: Power consumer calculation & attenuation unit (auxiliary power supply)
Note: All below consumer and distance calculation is based on each insulated system
Device
Number( n ) Consumer
Unit ( c )
n x c n x aAttenuation
Unit( a )
Internal Bus-Indoor Station
Audio handset--- (no additional consumer unit for
1
-
parallel indoor stations in audio system)
4.3" handset & hands-free--(additional consumer unit should be counted in parallel indoor stations)
7" hands-free--(additional consumer unit should be counted in parallel indoor stations)
1
17
1 or 0***
1 or 0***
Additional consumer unit in case parallel 4.3" indoor stations or 4.3' and audio in video system(Only consider the apartment with max. parallel indoor stations), the system controller is set as "one on"
Fig.77
11 or 0*
1
Additional consumer unit in case parallel 4.3" indoor stations or 4.3' and audio in video system(Only consider the apartment with max. parallel indoor
23 or 0*
1
stations), the system controller is set as "all on" Additional consumer unit in case parallel 7" indoor
stations or 7" and 4.3" or 7" and audio in video system(Only consider the apartment with max.
17
1
parallel indoor stations)
Internal Bus-System Device
Guard Unit Gateway Gateway (line amplified mode) Video distributor Switch actuator
IP-Gateway
15 or 0* 2 5 1 6
17
1
1.5
­2 1
1
Total consumer units for internal bus
The total consumer units should be less than below power unit whose value varies in 1 or >=2 apartments building >=2 apartments 1 apartment One standard auxiliary power supply in audio&video system,Total conumer units <=79 <=122 One mini auxiliary power supply in audio system, Total consumer units <=43 <=67 One mini auxiliary power supply in video system, Total consumer units <=38 <=53
Note: * When the device is powered by local power supply, the value of consumer unit=0. *** When looping through the indoor station, the attenuation unit=1, and when the indoor station is branched from the distributor, the attenuation=0
Fig.78
Distance calculation
Distance based on cable selected(m)--Check Table 2
B= (max. distance from system controller to the furthest indoor staion)
Fig.77
Parallel 4.3" indoor stations or 4.3" and audio in video system, the system controller is set as "one on"
62 | ABB-Welcome
Note: when make calculation of power consumer, the apartment with max. indoor stations. For the illustrated figure,the value of the additional quantity that should be counted is 2.
B: The distance from system controller to the furthest indoor staion (Table 2-1) A: The distance from outdoor station to the furthest indoor station (Table 2-2) A*:The distance from outdoor station to the furthest gateway (Table 2-3)
ABB-Welcome | 63
Page 33
B: Max. distance from system controller to the furthest indoor station, calculation is based on total power unit of internal bus(check Table1)
Table 2-1: Distance calculation for different cables (distance B)
unit:m
02 Planning Power consumer and distance calculation
Cable
Power consumer units
1-4 5-8 9-12 13-16 17-20 21-24 25-28 29-32 33-36 37-40 41-44 45-48 49-52 53-56 57-60 61-64 65-68 69-72 73-76 77-80 81-84 85-88 89-92 93-96
A: Max. distance from furthest outdoor station to furthest indoor station or gateway, calculation is based on the total attenuation unit (check Table 1) For audio system, the value of A is fixed
Cable
For Video system, the value of A varies due to differtent total attenuation unit from outdoor station to the last device
Table 2-2: Max distance from furthest outdoor station to furthest indoor station (distance A)
Cable
Attenuation unit 1-5 6-10 11-15 16-20 21-25 26-30 31-35 36-40 41-45 46-50 51-55 56-60 61-65 66-70
Coax, 75-5 Ø=0.75 mm, 0.45 mm²
Video system
370 340 310 290 270 250 240 230 210 200 190 190 180 170 160 160 150 150 140 140 130 130 120 120
Audio system
600 570 540 480 430 390 350 330 300 280 260 250 230 220 210 200 190 180 170 170 160 150 150 140
Coax, 75-5
650
Coax, 75-5
470 450 430 410 390 370 350 330 310 290 280 260 240 220
RVV, Ø=1 mm, 2 x 0.75 mm²
Video system
350 320 300 270 260 240 230 210 200 190 180 170 170 160 150 150 140 140 130 130 120 120 120 110
RVV, Ø=1 mm,
610 410 230 640
RVV, Ø=1 mm,
290 280 260 250 240 230 220 200 190 180 170 160 150 130
Audio system
570 540 510 450 400 370 330 310 280 260 250 230 220 210 200 190 180 170 160 160 150 140 140 130
J-Y(ST)-Y, Ø=0.8 mm, 2 x 0.5 mm²
Video system
230 210 200 180 170 160 150 140 130 130 120 120 110 110 100 100 90 90 90 90 80 80 80 80
J-Y(ST)-Y,Ø=0.8 mm,
J-Y(ST)-Y,Ø=0.8 mm,
150 140 140 130 120 120 110 110 100 90 90 80 80 70
Audio system
370 350 340 300 270 240 220 200 190 180 170 160 150 140 130 120 120 110 110 100 100 100 90 90
J-Y(ST)-Y, Ø=0.6 mm, 2 x 0.28 mm²
Video system
130 120 110 100 100 90 80 80 80 70 70 70 60 60 60 60 50 50 50 50 50 50 40 40
J-Y(ST)-Y,Ø=0.6 mm,
J-Y(ST)-Y,Ø=0.6 mm,
130 130 120 120 110 110 100 90 90 80 80 70 70 60
Audio system
200 190 190 170 150 140 130 120 110 100 90 90 80 80 70 70 70 60 60 60 60 50 50 50
UTP 5, 2 x Two pairs, each core Ø=0.5 mm 8 x 0.2 mm²
Video system
360 330 300 280 260 240 230 220 210 200 190 180 170 160 160 150 140 140 130 130 130 120 120 110
Audio system
580 550 520 460 410 370 340 310 290 270 250 240 220 210 200 190 180 170 170 160 150 150 140 140
unit:m
UTP 5, 2 x 2pairs
unit:m
UTP 5, 2 x 2pairs
300 290 280 270 250 240 230 220 200 190 180 170 150 140
Sample project 1: big single family home with 3 outdoor stations
One big villa with 3 outdoor stations all with one 1 button. First one is video with display as reader, second one as video with keypad, without display, third one is audio only, inside the apartment, 1 x 7", and 1 audio handset. All on mode with branch line connection by a video distributor. The cable will use RVV, Ø=1mm, The cable run is estimated to be around 200 meters from outdoor station to the 7".
Device
External Bus--Outdoor Station
Camera module Audio module(0/1/2-row button) Keypad module Display module(ID or IC)
External Bus--System Device
Outdoor distributor
Total consumer units for external bus 76
Internal Bus--Indoor Station
Audio handset 7" handsfree Additional consumer unit in case parallel 7" indoor
stations or 7" and 4.3" or 7" and audio in video system(Only consider the apartment with max. parallel indoor stations)
Total consumer units for internal bus 35
Total consumer units 111
System controller in video system,Total conumer units<=127
Conclusion: The power consumption is ok with one system controller. The max distance from outdoor station is 220m, so the distance is also OK.
Number( n ) Consumer
2 3 1 1
2
1 1
1
Unit ( c )
6 14 2 20
-
1 17
17
n x c n x aAttenuation
12 42 2 20
-
1 17
17
Unit( a )
-
-
-
-
15
0 1
1
Total attenuation units
Distance based on RVV, Ø=1mm,Check Table 2
-
-
-
-
30
0 1
1
B= (max. distance from system controller to the furthest indoor staion)
A= (max. distance from
32
outdoor station to the furthest indoor station)
200m
220m
Table 2-3: Max distance from furthest outdoor station to furthest gateway ( distance A*)
1-5 6-10 11-15 16-20 21-25 26-30 31-35 36-40 41-45 46-50 51-55 56-60 61-65 66-70
64 | ABB-Welcome
Coax, 75-5Attenuation unit
310 290 280 260 240 220 200 180 160 140 120 100 80 60
RVV, Ø=1 mm,
190 180 170 160 150 130 120 110 100 90 70 60 50 40
J-Y(ST)-Y,Ø=0.8 mm,
100 90 90 80 80 70 60 60 50 40 40 30 30 20
J-Y(ST)-Y,Ø=0.6 mm,
90 80 80 70 70 60 60 50 50 40 30 30 20 20
unit:m
UTP 5, 2 x 2pairs
200 190 180 170 150 140 130 120 100 90 80 70 50 40
ABB-Welcome | 65
Page 34
Fig.79
Big single family home with 3 outdoor stations
» System type: audio/video combined » Wiring: looping through
» Devices used: » Two camera modules » Three audio modules » One keypad module » One display module » Two cover frames, size 1/3 » One cover frame, size 1/1 » Two flush mounted boxes, size 1/3 » One flush mounted box, size 1/1 » Two outdoor distributors » One system controller » One 7” video hands-free indoor station » One audio handset indoor station » Three electric door opener (not provided by ABB)
The power consumption is fine with one system controller. The max distance from outdoor station is 220m, so the distance is also OK without amplifier
02 Planning Power consumer and distance calculation
Sample project 2: condominium with 12 apartments
One keypad OS (display is included+4pcs name plate modules) with 12 apartments, 10 apartments with 3 pcs 4.3" in each apartment and 2 apartments with 1 audio handset per apartment, one standard system controller under "one on" working mode. Branch line connection with 3pcs of video distributor (4 apartments per distributor). Cable will use J-Y(ST)-Y,Ø=0.6mm. The cable run will be around 100m from outdoor station to last indoor station.
Device
External Bus--Outdoor Station
Camera module Audio module(0/1/2-row button) Keypad module Display module(ID or IC) Nameplate module
Total consumer units for external bus 46
Internal Bus--Indoor Station
Audio handset
4.3" handset & hands-free Additional consumer unit in case parallel 4.3" indoor
stations or 4.3" and audio in video system(Only consider the apartment with max. parallel indoor
stations), the system controller is set as "one on"
Internal Bus--System Devices
Video distributor
Total consumer units for internal bus 57
Total consumer units 103
One standard system controller in video system,Total conumer units<=96
Conclusion: The power consumption 96<103, so one standard system controller is not enough, and the distance is OK.
Number( n )
1 1 1 1 4
2 30
2
3
Consumer Unit ( c )
6 14 2 20 1
1 1
11
1
n x c
6 14 2 20 4
2 30
22
3
Attenuation Unit( a )
-
-
-
-
-
0 0
1
2
Total attenuation units
Distance based on J-Y(ST)-
n x a
Y,Ø=0.6mm, Check Table 2
-
-
-
-
-
0 0
2
6
B= (max. distance from system controller to the furthest indoor staion)
A= (max. distance from
8
outdoor station to the furthest indoor station)
60m
130m
Solution: The outdoor station is locally powered by one mini system controller
Device
External Bus--Outdoor Station
Camera module Audio module(0/1/2-row button)
Keypad moduleNameplate module Display module(ID or IC) Nameplate module
Total consumer units for external bus 0
Internal Bus--Indoor Station
Audio handset
4.3" handset & hands-free
Additional consumer unit in case parallel 4.3" indoor stations or 4.3" and audio in video system(Only consider the apartment with max. parallel indoor stations), the system controller is set as "one on"
Internal Bus--System Devices
Video distributor
Total consumer units for internal bus 57
Total consumer units 57
One standard system controller in video system, Total consumer units<=96
Conclusion: The power consumption is ok with this solution. The max distance from outdoor station is 130m, so the distance is also OK .
Number( n )
1 1 1 1 4
2 30
2
3
Consumer Unit ( c )
0 0 0 0 0
1 1
11
1
n x c
0 0 0 0 0
2 30
22
3
Attenuation Unit( a )
-
-
-
-
-
0 0
1
2
Total attenuation units
Distance based on J-Y(ST)-
n x a
Y,Ø=0.6mm, Check Table 2
-
-
-
-
-
0 0
2
6
B= (max. distance from system controller to the furthest indoor staion)
8
A= (max. distance from outdoor station to the furthest indoor station)
60m
130m
66 | ABB-Welcome
ABB-Welcome | 67
Page 35
Fig.80
Condominium with 12 apartments
» System type: audio/video combined » Wiring: branch line by distributor connection
» Devices used: » One camera module » One audio module » One keypad module » Four nameplate modules » One cover frame, size 2/4 » One flush mounted box, size 2/4 » One system controller » One mini system controller » Three video distributors » Thirty 4.3” video hands-free indoor stations » Two audio handset indoor stations » One electric door opener (not provided by ABB)
One standard system controller is not enough, need to add a local power supply for outdoor station.
02 Planning Power consumer and distance calculation
Sample project 3: Condominium with 3 outdoor stations and 12 apartments
1 building with 3 video push button outdoor stations of 12 apartments, each apartment is equipped with 3x4.3" video hands­free indoor stations, all the screens should be turned on in case being called from outdoor station. The topology is going to be looping the video distributor with one supporting 2 apartments in which looping the indoor station will be uses.The cable will use J-Y(ST)-Y,Ø=0.6mm. The cable run will be around 40m from outdoor station to system controller, and 40m from system controler to last indoor station.
Device
External Bus--Outdoor Station
Camera module Audio module(0/1/2-row button) Push button module(3-row or 4-row)
External Bus--System device
Outdoor distributor
Total consumer units for external bus 72
Internal Bus--Indoor Station
4.3" handset & hands-free Additional consumer unit in case parallel 4.3" indoor
stations or 4.3" and audio in video system(Only consider the apartment with max. parallel indoor staions), the system controller is set as "all on".
Internal Bus--System Devices
Video distributor
Total consumer units for internal bus 88
Total consumer units 160
One standard system controller in video system,Total conumer units<=96
Conclusion: The power consumption 96<160, so one standard system controller is not enough, and the distance is OK.
Number( n )
3 3 12
2
36
2
6
Consumer Unit ( c )
6 14 1
-
1
23
1
n x c
18 42 12
-
36
46
6
Attenuation Unit( a )
-
-
-
15
0
1
2
Total attenuation units
Distance based on J-Y(ST)-
n x a
Y,Ø=0.6mm, Check Table 2
-
-
-
30
0
2
12
B= (max. distance from system controller to the furthest indoor staion)
A= (max. distance from
44
outdoor station to the furthest indoor station)
50m
90m
Solution: Each of the outdoor stations are locally powered by one mini system controller
Device
External Bus--Outdoor Station
Camera module Audio module(0/1/2-row button) Push button module(3-row or 4-row)
External Bus--System device
Outdoor distributor
Total consumer units for external bus 0
Internal Bus--Indoor Station
4.3" handset & hands-free
Additional consumer unit in case parallel 4.3" indoor stations or 4.3" and audio in video system(Only consider the apartment with max. parallel indoor staions), the system controller is set as "all on".
Internal Bus--System Devices
Video distributor
Total consumer units for internal bus 88
Total consumer units 88
One standard system controller in video system,Total conumer units<=96
Conclusion: The power consumption 88<96, so one standard system controller plus 3 local power supply are enough, the distance is also OK.
Number( n )
3 3 12
2
36
2
6
Consumer Unit ( c )
0 0 0
-
1
23
1
n x c
0 0 0
-
36
46
6
Attenuation Unit( a )
-
-
-
15
0
1
2
Total attenuation units
Distance based on J-Y(ST)-
n x a
Y,Ø=0.6mm, Check Table 2
-
-
-
30
0
2
12
B= (max. distance from system controller to the furthest indoor staion)
A= (max. distance from
44
outdoor station to the furthest indoor station)
50m
90m
68 | ABB-Welcome
ABB-Welcome | 69
Page 36
Fig.81
Condominium with 3 outdoor station and 12 apartments
» System type: video » Wiring: branch line by distributor connection » Devices used » Three camera module » Three audio module » Twelve button module, 3/6 pushbutton » Three cover frame, size 2/3 » Three flush mounted box, size 2/3 »
Two outdoor distributor
»
One system controller
»
Three mini system controller
»
Six video distributor
»
Thirty six 4.3” video hands-free indoor station
»
Three electric door opener(not provided by ABB) One standard system controller is not enough, and distance is ok, need to add a local power supply for each outdoor station.
02 Planning Power consumer and distance calculation
Sample project 4: residential complex with 4 entrances
4 gate stations, one is keypad with display (ID card reader), and the other is video push button modules with up to 7x4­row modules, 4 buildings are looped with building gateway together with 1 guard unit, the system controller is used to feed all the above products in the common part. The max. distance from gate station to last building is around 250m. RVV, Ø=1mm, is going to be used.
Device
External Bus--Outdoor Station
Camera module Audio module(0/1/2-row button) Keypad module Display module(ID or IC)
External Bus--System device
Outdoor distributor
Total consumer units for external bus 168
Internal Bus-System Devices
Guard unit
Gateway in the common part
Total consumer units for internal bus 23
Total consumer units 191
One standard system controller in video system,Total conumer units<=96
Conclusion: The power consumption191>96, so one standard system controller is not enough, and also the distance can not be met without
amplifier
Number( n )
4 4 4 4
2
1
4
Solution: gate stations are powered by local power supply, while like only one gate station is counted to have the consumer
units, 1 gateway as amplifier can be used in the first building
Device
External Bus--Outdoor Station
Camera module Audio module(0/1/2-row button) Keypad module Display module(ID or IC)
External Bus--System Device
Outdoor distributor
Total consumer units for external bus 42
Internal Bus-System Device
Guard unit
Gateway (line amplifier mode) Gateway
Total consumer units for internal bus 28
Total consumer units 70
One standard system controller in video system,Total conumer units<=96
Conclusion: The power consumption 70<96, so one standard system controller plus 3 local power supplies are enough, the distance can be met by a line amplifier
Number( n )
1 1 1 1
2
1
1
4
Analysis: The network system involves 5 insulated systems: 4 buildings and one in the common part. Each insulated system should be evaluated respectively. Only the insulated system in the common part will be examplified.
Consumer Unit ( c )
6 14 2 20
-
15
2
Consumer Unit ( c )
6 14 2 20
-
15
5
2
n x c
24 56 8 80
-
1581
n x c
6 14 2 20
-
15
Total attenuation units for system controller
5
8
Attenuation Unit( a )
-
-
-
-
15
1.5
Total attenuation units
Attenuation Unit( a )
-
-
-
-
15
1
-
1.5
Total attenuation units
Distance based on RVV, Ø=1mm
n x a
Check Table 2
-
-
-
-
30
1
6
B= Max. distance from system controller to the furthest building
A= (Max. distance from
37
gate station to the furthest building) (check Table 2-3)
Distance based on RVV, Ø=1mm
n x a
Check Table 2
-
-
-
-
30
1
A1=Max. distance from
31
gate station to the added gateway (check Table 2-3)
-
6
B= (Max. distance from system controller to the furthest building(check Table 2-1)
A2=Max. distance from the
6
added gateway to the furthest building(check Table 2-3)
240m
110m
120m
230m
180m
70 | ABB-Welcome
ABB-Welcome | 71
Page 37
Fig.82
Residential complex with 4 entrance
02 Planning Power consumer and distance calculation
» System type: video » Wiring: branch line by distributor connection » Devices used (common part only) » Four keypad outdoor stations, with ID card reader
Four flush mounted boxes, size 1/4
» » Three outdoor distributors » One guard unit » One system controller » Three mini system controllers » Four electric door openers (not provided by ABB)
One standard system controller is not enough, and distance is problem, need to add a local power supply for each outdoor station and a gateway in the internal bus of common part.
Sample project 5: high-rising building with 140 apartments
1 building with 2 video keypad outdoor station with display. The building has 140 apartments, with 110 apartments with one audio handset, and 28 with one 4.3" hands-freee indoor station, two last apartments with 2 x 4.3" hands-free
Step1: For the 140 apartments, check the "The mixed power solution for keypad outdoor station with display"table
Divide the 140 apartments into Four insulated systems, and "auxiliary power supply+gateway" is used for the last three insulated systems.
indoor stations/apartment. For these 2 apartments, each are
»
equipped with a second confirmed outdoor station before the private door. Whole system is branch line connection through
1st insulated system: 2 keypad outdoor stations with 3
gateway in the internal bus -- one standard system controller.
distributor with each supporting 4 indoor stations. System
»
controller is set under "all on" working mode. The cable will use RVV, Ø=1mm, the distance from outdoor station to the furthest indoor station is estimated to be 150m.
Analysis: For the140 apartments, please check the "The mixed power solution for keypad outdoor station with display" to get an easy reference.
2nd insulated system: 62 apartments(62 pcs audio indoor stations) with 16 vdieo distributors -- one standard auxiliary system controller.
»
3rd insulated system: 62 apartments(48 pcs audio indoor stations + 14 pcs 4.3" video handsfree indoor stations) with 16 vdieo distributors -- one standard auxiliary system controller.
For the last 2 apartements equipped with 2 second-confirmed
»
outdoor stations, apatment gateway should be used.
4th insulated system: 16 apartments(14 pcs 4.3" video handsfree indoor stations + last 2 apartment systems) with 4 vdieo distributors -- one mini auxiliary system controller
For 1st insulated system:
Device
External Bus--Outdoor Station
Camera module
Audio module(0/1/2-row button)
Keypad module
Display module(ID or IC)
External Bus--System Device
Outdoor distributor
Total consumer units for external bus 84
Internal Bus-System Device
Gateway
Mini system controller in video system,Total conumer units<=96
Conclusion: The power consumption 90<96, so one standard system controller is OK, and distance is also OK.
Number( n )
2
2
2
2
1
3
Total consumer units for internal bus 6
Total consumer units 90
Consumer Unit( c )
6
14
2
20
-
2
n x c
12
28
4
40
-
6
Attenuation Unit( a )
-
-
-
-
15
1.5
Total attenuation units
n x a
-
-
-
-
15
4.5
19.5
Distance based on RVV, Ø=1mm, Check Table 2
B=Max. distance from system controller to the furthest gateway
A=Max. distance from outdoor station to the furthest gateway (check Table 2-3)
320m
160m
72 | ABB-Welcome
For 2nd/3rd/4th insulated systems, the value is OK accroding to Table "the mixed power solution for keypad outdoor station with display".
Step2: For the 2 apartments with second-confirmed outdoor station, each is equipped with a mini system controller and apartment gateway.
Device
External Bus--Outdoor Station
Camera module
Audio module(0/1/2-row button)
External Bus--System Device
Gateway
Total consumer units for external bus 25
Internal Bus-Indoor Station
4.3" handset & hands-free Additional consumer unit in case parallel 4.3"
indoor stations or 4.3'"and audio in video system(Only consider the apartment with max. parallel indoor stations), the system controller is set as "all on"
Mini system controller in video system,Total conumer units<=58
Conclusion: The power consumption 50<58, so one mini system controller for each of apartment with second-conrmed outdoor station is OK
Number( n )
1
1
1
2
1
Total consumer units for internal bus 25
Total consumer units 50
Consumer Unit( c )
6
14
5
1
23
n x c
6
14
5
2
23
Attenuation Unit( a )
-
-
-
1
1
n x a
-
-
-
2
1
Distance based on RVV, Ø=1mm, Check Table 2
ABB-Welcome | 73
Page 38
Fig.83
High-rising building with 140 apartments
» System type: audio/video combined » Wiring: branch line by distributor connection »
Devices used
» Two keypad outdoor station » Two flush mounted box, size 1/4 » Two camera module » Two audio module, 1/2 pushbutton » Two cover frame, size 1/2 » Two flush mounted box, size 1/2 » Thirty six video distributor » One outdoor distributor » Three system controller » Five gateway » Three mini system controller » One hundred and ten audio handset » Thirty-two 4.3" video handsfree » Four electric door opener (not provided by ABB)
It is OK to use one mini system controller for each of the apartment system of the last 2 apartment with second confirmed outdoor station, distance is also OK.
02 Planning Power consumer and distance calculation
Rule to maximize the distance calculation in the common part
In the residential complexes, the actual distance from the gate station to the furthest gateway can be really long. So, by balancing the wiring topology and system total cable length, the combination of looping the gateway and looping the distributor together with auxiliary power supply in the common part can be used to maximize the distance calculation rule.
Checking the Table 2, if 3 gateways are looped through in the trunk of the common part, it can be allowed a maximum of 200m (check Table 2-3) by UTP cable for A1 (3x1.5=4.5 units), and the max. cable distance from last gateway in auxiliary power supply in the trunk to the furthest building gateway of Area6 with A2≤190m (check Table2-3) of UTP cable (2+3x1.5=6.5 units).
Fig.84
Fig.84
Rule to maximize the distance of cable
74 | ABB-Welcome
ABB-Welcome | 75
Page 39
02 Planning Power consumer and distance calculation
Based on Table 3-1, for audio or video keypad outdoor station whose power units value are fixed, then, the capacity for different types of indoor station are available as below:
Reverse calculation for capacity of system controller andauxiliary power supply
Based on Table 1-1 and Table 1-2, suppose after deducting the consumer units of other devices in external bus and internal bus(for example the outdoor station), the remaining power units for indoor station and video distributor(if has) in the internal bus=R. then, below Table3-1 is the reverse calculation to efficiently know the capacity of different power supply.
Table 3-1: Internal bus capacity formula for system controller and auxiliary power supply
Indoor
The
station
setting of
type
Standard
System
controller
Audio
indoor
"One On"
station
or " All on"
in audio
system
Audio
indoor
station
or 4.3"
"One On"
video
indoor
station
in video
system
"All On"
For example:
For an audio system with 1 audio outdoor station with keypad but without display(total 14+2=16 units), mini system controller is used, then
»
R=60-16=44 units. From above table, it can support max. 44/3=14 apartments with 3 indoors stations/apartments.
For a video system, 2 parallel outdoor stations are fed by local power supply, standard system controller is used with "one on", then R=96-
»
0=96 units. From the above table, it can support (96-22)/3.25=22 apartments with 3 IS/apartment, the no. of video distributor 22/4=6. with each
supporting 4 apartments.
For a video system, 1 keypad outdoor station is fed by local power supply, standard system controller is used with "all on", then R=96-0=96
»
units. From the above table, it can support(96-23)/2.5=29 apartments with 2 x4.3" video IS/apartment, the no. of video distributor 29/2=15 with
each supporting 2 apartments.
For a video system, 1pc push button outdoor station with 1 push button module(Total 6+14+1=21 units) is used, standard system controller is
»
used with "all on", then R=96 - 21=75 units. From above table, it can support (75-46)/3.5=8 apartments with 3x4.3" video IS/apartments, the no.
of video distributor =8/2=4 pcs with each supporting 2 apartments.
1 indoor station /apartment 2 indoor stations /apartment 3 indoor stations /apartment 4 indoor stations /apartment
Max. No. of apartment
R - - R/2 - - R/3 - - R/4 - -
R/1.25 R/2.5 - (R-11)/2.25 (R-11)/2.25/4 - (R-22)/3.25 (R-22)/3.25/4 - (R-33)/4.25 (R-33)/4.25/4 -
R//1.5 - R/3 (R-11)/2.5 - (R-11)/2.5/2 (R-22)/3.5 - (R-22)/3.5/2 (R-33)/4.5 - (R-33)/4.5/2
R - - (R-11)/2 - - (R-22)/3 - - (R-33)/4 - -
R/1.25 R/2.5 - (R-23)/2.25 (R-23)/2.25/4 - (R-46)/3.25 (R-46)/3.25/4 - (R-69)/4.25 (R-69)/8.5 -
R//1.5 - R/3 (R-23)/2.5 - (R-23)/2.5/2 (R-46)/3.5 - (R-46)/3.5/2 (R-69)/4.5 - (R-69)/4.5/2
R - - (R-23)/2 - - (R-46)/3 - - (R-69)/4 - -
No. of video distributor with each supporting 4 apartments
No. of video distributor with each supporting 2 apartments
Max. No. of apartment
No. of video distributor with each supporting 4 apartments
No. of video distributor with each supporting 2 apartments
Max. No. of apartment
No. of video distributor with each supporting 4 apartments
No. of video distributor with each supporting 2 apartments
Max. No. of apartment
No. of video distributor with each supporting 4 apartments
No. of video distributor with each supporting 2 apartments
Table 3-2: Internal bus capacity for one standard system controller with only one keypad outdoor station
Indoor
station
type
Audio
indoor
station
in audio
system
with one
audio
keypad
outdoor
station
Audio
indoor
station
or 4.3"
video
indoor
station
in video
system
with one
video
keypad
outdoor
station
The
setting of
Standard
System
controller
"One On" or " All on"
"One On"
"All On"
1 indoor station /apartment 2 indoor stations /apartment 3 indoor stations /apartment 4 indoor stations /apartment
Max. No. of apartment
60 - - 30 - - 20 - - 15 - -
43 11 - 19 (5 - 9 3 - 4 1 -
36 - 18 17 - 9 9 - 5 4 - 2
43 11 - 13 4 - 2 1 - - - -
36 - 18 12 - 6 2 - 1 - - -
No. of video distributor with each supporting 4 apartments
No. of video distributor with each supporting 2 apartments
Max. No. of apartment
No. of video distributor with each supporting 4 apartments
No. of video distributor with each supporting 2 apartments
Max. No. of apartment
No. of video distributor with each supporting 4 apartments
No. of video distributor with each supporting 2 apartments
Max. No. of apartment
No. of video distributor with each supporting 4 apartments
No. of video distributor with each supporting 2 apartments
Based on Table 3-1, for audio or video keypad outdoor station whose power units value are fixed, then, the capacity for different types of indoor station are available as below:
Table 3-3: Internal bus capacity for one standard auxiliary power supply
Indoor
The
station
setting of
type
Standard
System
controller
Audio
"One On" or " All on"
indoor
station
in audio
system
Audio
"One On" 63 16 - 30 8 - 17 5 - 10 3 -
indoor
station
or 4.3"
video
"All On 63 16 - 24 6 - 10 3 - Local power supply is recommended
indoor
station
in video
system
7" indoor
"One
station
On" or "
in video
All on"
system
1 indoor station /apartment 2 indoor stations /apartment 3 indoor stations /apartment 4 indoor stations /apartment
Max. No. of apartment
79 - - 39 - - 26 - - 19 - -
52 - 26 27 - 14 16 - 8 10 - 5
52 - 26 22 - 11 9 - 5
4 1 - 2 1 - 1 1 or 0 by looping through 1 1 or 0 by looping through
4 - 2 2 - 1
No. of video distributor with each supporting 4 apartments
No. of video distributor with each supporting 2 apartments
Max. No. of apartment
No. of video distributor with each supporting 4 apartments
No. of video distributor with each supporting 2 apartments
Max. No. of apartment
No. of video distributor with each supporting 4 apartments
No. of video distributor with each supporting 2 apartments
Max. No. of apartment
No. of video distributor with each supporting 4 apartments
No. of video distributor with each supporting 2 apartments
Remark: To see the whole picture of all kinds of indoor station supported by auxiliary power supply, despite the 7" capacity is the result out of the table 1-2, it is still shown in this table. Also for 2 indoors/apartment. the result is still valid despite conflict with the result counted by Table 1-2, in which some buffer has been given.
76 | ABB-Welcome
ABB-Welcome | 77
Page 40
2pairs
UTP 5, 2 x
J-Y(ST)-
Y,Ø=0.6mm,
J-Y(ST)-
Y,Ø=0.8mm,
Table 3-4: Internal bus capacity for one mini auxiliary power supply
Indoor
The
station
setting of
type
Standard
System
controller
Audio
"One On" or " All on"
indoor
station
in audio
system
Audio
"One On" 30 8 - 12 3 - 4 1 - Local power supply is recommended
indoor
station
or 4.3"
video
"All On 30 8 - 6 2 - Local power supply is recommended Local power supply is recommended
indoor
station
in video
system
7" indoor
"One
station
On" or "
in video
All on"
system
1 indoor station /apartment 2 indoor stations /apartment 3 indoor stations /apartment 4 indoor stations /apartment
Max. No. of apartment
No. of video distributor with each supporting 4 apartments
No. of video distributor with each supporting 2 apartments
Max. No. of apartment
No. of video distributor with each supporting 4 apartments
43 - - 21 - - 14 - - 10 - -
25 - 13 10 - 5 4 - 2
25 - 13 6 - 3
2 1 - 1 1 - - -
2 - 1 1 - 1
No. of video distributor with each supporting 2 apartments
Max. No. of apartment
No. of video distributor with each supporting 4 apartments
No. of video distributor with each supporting 2 apartments
Max. No. of apartment
No. of video distributor with each supporting 4 apartments
No. of video distributor with each supporting 2 apartments
02 Planning
Quick reference
Distance range and cable type
B=From system controller to the furthest indoor station
A=From one or parallell outdoor stations to the furthest indoor station
+ 51021J
51024CF-
. +41024F
51029CF-
. +41029F
51026CF-
. +41026F
51025CF-
. +41025F
51028CF-
. +41028F
51024CF-
. +41024F
51023CF-
. +41023F
51022CF-
.+ 41022F
RVV,
Ø=1mm,
Coax, 75-5
51021CF-
Audio Outdoor Station Composed by 3-row Button Modules
Module
Nameplate
Button
Module
fed by
or mini
standard system sontroller
No. of audio outdoor station
System
controller
.+ 41021F
Audio Module Cover Frame & Flush-mounted Box
M251021P3 51021DN M251021A-. M251022A-. M251023A-.
OS modules are
system controller
The article no. of the composed
M2300
or M2301
x1 x1
selected audio module
push button module and the
x1
Below apartment no. is composed by selected
By
M2301
By
M2300
By
shown in the right
M2301
By
M2300
51021RH 51023RH 51028RH 51026RH 51027RH51022RH 51024RH 51025RH 51029RH
* Optional to install rain hood
78 | ABB-Welcome
or
No.
Indoor
2.7 Easy reference for the modular outdoor station solution
The mixed power solution for pushbutton outdoor station
station
M2200.-.
Apartment No.
1-2 1-4 1 6 4 6 4 - - 1 1-2 2 3-4 650m 600m 610m 570m 410m 370m 230m 200m 640m 580m
Single Double Single Double Single Double Single Double Single Double A B A B A B A B A B
3-5 5-10 1 5 3 5 2 1 - 3 5-6 4 7-8 5 9-10 650m 540m 610m 510m 410m 340m 230m 190m 640m 520m
6-8 11-16 1 5 2 4 2 2 - 6 11-12 7 13-14 8 15-16 650m 480m 610m 450m 410m 300m 230m 170m 640m 460m
9-11 17-22 1 4 2 3 1 3 - 9 17-18 10 19-20 11 21-22 650m 390m 610m 370m 410m 240m 230m 140m 640m 370m
12-14 23-28 1 4 2 3 1 4 - 12 23-24 13 25-26 14 27-28 650m 350m 610m 330m 410m 220m 230m 130m 640m 340m
15-17 29-34 1 3 2 2 1 5 - 15 29-30 16 31-32 17 33-34 650m 300m 610m 280m 410m 190m 230m 110m 640m 290m
18-20 35-40 1 3 1 2 - 6 1 18 35-36 19 37-38 20 39-40 650m 280m 610m 260m 410m 180m 230m 100m 640m 270m
21-23 41-46 1 3 1 2 - 7 - 21 41-42 22 43-44 23 45-46 650m 250m 610m 230m 410m 160m 230m 90m 640m 240m
24-26 47-52 1 2 1 1 - 8 1 24 47-48 25 49-50 26 51-52 650m 230m 610m 220m 410m 150m 230m 80m 640m 220m
27-29 53-58 1 2 1 1 - 9 - 27 53-54 28 55-56 29 57-58 650m 210m 610m 200m 410m 130m 230m 70m 640m 200m
be locally powered. For example, for a building with 32
apartments, the 3-row single button modules are used, totally,
3 outdoor stations are required, then 2 outdoor stations can
be powered by standard system controller, and the third one
should be powered by mini local power supply.
possible with the combination of audio module with button, it
is recommended to use pure audio module with 3-row button
module. Then for example for 28 buttons, the 5 pcs of 3-row
30-32 59-64 1 2 1 1 - 10 1 30 59-60 31 61-62 32 63-64 650m 200m 610m 190m 410m 120m 230m 70m 640m 190m
33-35 65-70 1 2 1 1 - 11 - 33 65-66 34 67-68 35 69-70 650m 180m 610m 170m 410m 110m 230m 60m 640m 170m
Remarks:
1. For each of the additional parallel outdoor station , it should
button module should be used.
2.For double button outdoor station, despite techenically
ABB-Welcome | 79
Page 41
2. For each of the additional parallel outdoor station , it should than 73, as thestandard system controller can not fully cover
the required power units
be locally powered. For example, for a building with 64
apartments, the 4-rowdouble button modules are used, totally,
2 outdoor stations are required, then one outdoor station is
powered by standard system controller,and the second one
should be powered by mini local power supply.
Remarks:
1. * means the outdoor station should be powered by one mini
local power supply when the no. of indoor stations are more
* Optional to install rain hood
43-46 87-92 1 2 - 1* - 11 - 43-44 87-88 45 89-90 46 91-92 650m 150m 610m 140m 410m 90m 230m 50m 640m 140m
39-42 79-84 1 2 - 1* - 10 1 39-40 79-80 41 81-82 42 83-84 650m 160m 610m 150m 410m 100m 230m 60m 640m 150m
35-38 71-76 1 2 - 1* - 9 - 35-36 71-72 37 73-74 38 75-76 650m 170m 610m 160m 410m 110m 230m 60m 640m 170m
31-34 63-68 1 2 - 1 - 8 1 31-32 63-64 33 65-66 34 67-68 650m 190m 610m 180m 410m 120m 230m 70m 640m 180m
27-30 55-60 1 2 1 1 - 7 - 27-28 55-56 29 57-58 30 59-60 650m 210m 610m 200m 410m 130m 230m 70m 640m 200m
23-26 47-52 1 3 1 1 - 6 1 23-24 47-48 25 49-50 26 51-52 650m 230m 610m 220m 410m 150m 230m 80m 640m 220m
19-22 39-44 1 3 1 2 - 5 - 19-20 39-40 21 41-42 22 43-44 650m 260m 610m 250m 410m 170m 230m 90m 640m 250m
15-18 31-36 1 3 2 2 - 4 - 15-16 31-32 17 33-34 18 35-36 650m 300m 610m 280m 410m 190m 230m 110m 640m 290m
11-14 23-28 1 4 2 3 1 3 - 11-12 23-24 13 25-26 14 27-28 650m 350m 610m 330m 410m 220m 230m 130m 640m 340m
7-10 15-20 1 4 2 4 1 2 - 7-8 15-16 9 17-18 10 19-20 650m 430m 610m 400m 410m 270m 230m 150m 640m 410m
3-6 7-12 1 5 3 4 2 1 - 3-4 7-8 5 9-10 6 11-12 650m 540m 610m 510m 410m 340m 230m 190m 640m 520m
1-2 1-4 1 6 4 6 4 - - 1 1-2 2 3-4 650m 600m 610m 570m 410m 370m 230m 200m 640m 580m
Single Double Single Double Single Double Single Double Single Double A B A B A B A B A B
M2300
By
M2301
M2300
M2301
push button module and the
selected audio module
shown in the right
By
By
By
Below apartment no. is composed by selected
x1
x1 x1
Apartment No.
M2200.-. M2300
or M2301
The article no. of the composed
OS modules are
M251021P4 51021DN M251021A-. M251022A-. M251023A-.
station
Indoor
No.
or
controller
System
No. of audio outdoor station
standard system sontroller
system controller
or mini
fed by
Module
Button
Nameplate
Module
Audio Module Cover Frame & Flush-mounted Box
02 Planning
Quick reference
Distance range and cable type
B=From system controller to the furthest indoor station
A=From one or parallell outdoor stations to the furthest indoor station
-. + 51021J
51024CF
41024F +
-. +
41029F
51029CF
-. +
41026F
51026CF
-. +
41025F
51025CF
2pairs
UTP 5, 2 x
J-Y(ST)-
Y,Ø=0.6mm,
J-Y(ST)-
Y,Ø=0.8mm,
Ø=1mm,
Coax, 75-5 RVV,
50m 30m- - - - -20m 20m 40m
For each one of video parallel OS, for A, below amount of distance should be subtracted.
51021RH 51023RH 51028RH 51026RH 51027RH51022RH 51024RH 51025RH 51029RH
.+ 41021F
.+ 41022F
. +41023F
. +41024F
. +41028F
. +41025F
. +41026F
. +41029F
. +41024F
+ 51021J
51021CF-
51022CF-
51023CF-
51024CF-
51028CF-
51025CF-
51026CF-
51029CF-
51024CF-
Audio Outdoor Station Composed by 4-row Button Modules
Video Outdoor Station Composed by 3-row Button Modules
Audio Module Cover Frame & Flush-mounted Box
Nameplate
Button
Module
Module
-. +
51028CF
-. +
51024CF
-. +
51023CF
-. +
M251021A-. M251022A-. M251023A-. 51022CF
41028F
41024F
41023F
41022F
x1
button
x1
module and the selected audio module
x1
Below apartment no. is composed by selected push
51022RH 51023RH 51024RH 51028RH 51025RH 51026RH 51029RH 51027RH
Optional to install rain hood
80 | ABB-Welcome
Coax, 75-5
Ø=1mm,
RVV,
Y,Ø=0.8mm,
J-Y(ST)-
Y,Ø=0.6mm,
J-Y(ST)-
UTP 5, 2 x
2pairs
A=From one or parallell outdoor stations to the furthest indoor station
B=From system controller to the furthest indoor station
Distance range and cable type
Camera
outdoor
No. of video
station fed by
standard system
System
controller
No.
Video
distributor
or
No.
Indoor
station
Module
sontroller or mini
system controller
Apartment No.
M251021C M251021P3 51021DN
the
modules
composed OS
The article no. of
M2304 M2300
M2231.-.
are shown in the
or M2301
M2230.-.
rightt
or
standard system controller.(M2300)
station in addtion to the system controller(M2301)
be locally powered. For example, for a building with 32
apartments, 2 outdoorstations are required, then one outdoor
station is powered by standard system controller, and the
second outdoor station should be poweredby mini local power
supply.
possible with the combination of audio module with button, it
is recommended touse pure audio module with 3-row button
module. Then for example for 28 buttons, the 5 pcs of 3-row
1-2 1-4 1 1 1 4 or 1* 4 or 1* 1 - - 1 1-2 2 3-4 470m 340m 290m 320m 150m 210m 130m 120m 300m 330m
3-5 5-10 1-2 2-3 1 4 3 1 1 - 3 5-6 4 7-8 5 9-10 450m 290m 280m 270m 140m 180m 130m 100m 290m 280m
6-8 11-16 2 3-4 1 3 3 1 2 - 6 11-12 7 13-14 8 15-16 450m 270m 280m 260m 140m 170m 130m 100m 290m 260m
9-11 17-22 3 5-6 1 3 2 1 3 - 9 17-18 10 19-20 11 21-22 430m 240m 260m 230m 140m 150m 120m 80m 280m 230m
12-14 23-28 3-4 6-7 1 3 2 1 4 - 12 23-24 13 25-26 14 27-28 430m 210m 260m 200m 140m 130m 120m 80m 280m 210m
15-17 29-34 4-5 8-9 1 2 2 1 5 1 15 29-30 16 31-32 17 33-34 410m 190m 250m 190m 130m 120m 120m 70m 270m 190m
18-20 35-40 5 9-10 1 2 1 1 6 - 18 35-36 19 37-38 20 39-40 410m 180m 250m 170m 130m 110m 120m 60m 270m 170m
21-23 41-46 6 11-12 1 2 1 1 7 1 21 41-42 22 43-44 23 45-46 390m 160m 240m 160m 120m 100m 110m 60m 250m 160m
24-26 47-52 6-7 12-13 1 2 1 1 8 - 24 47-48 25 49-50 26 51-52 370m 150m 230m 150m 120m 90m 110m 50m 240m 140m
27-29 53-58 7-8 14-15 1 1 1** 1 9 1 27 53-54 28 55-56 29 57-58 370m 140m 230m 140m 120m 90m 110m 50m 240m 130m
Single Double Single Double Single Double Single Double Single Double Single Double A B A B A B A B A B
30-32 59-64 8 15-16 1 1 1** 1 10 - 30 59-60 31 61-62 32 63-64 350m 140m 220m 130m 110m 90m 100m 50m 230m 130m
Remarks:
1. * means one mini system controller, others are the no. of
2. ** means the local power supply should power that outdoor
3. For each of the additional parallel outdoor station , it should
button module should be used.
4. For double button outdoor station, despite techenically
ABB-Welcome | 81
Page 42
2. ** means the local power supply should power that outdoor
3. For each of the additional parallel outdoor station , it should station in addtion to the system controller(M2301)
be locally powered. For example, for a building with 32
apartments, 2 outdoorstations are required, then one outdoor
station is powered by standard system controller, and the
second outdoor station should be powered by mini local
power supply.
Remarks:
1. * means one mini system controller, others are the no. of
standard system controller(M2300)
Optional to install rain hood
51022RH 51023RH 51024RH 51028RH 51025RH 51026RH 51029RH 51027RH
39-42 77-84 8 15-16 1 1 1** 1 10 - 39-40 79-80 41 81-82 42 83-84 350m 120m 220m 110m 110m 80m 100m 40m 230m 110m
35-38 69-76 7-8 14-15 1 1 1** 1 9 1 35-36 71-72 37 73-74 38 75-76 370m 120m 230m 120m 120m 80m 110m 40m 240m 120m
31-34 61-68 6-7 12-13 1 1 1** 1 8 - 31-32 63-64 33 65-66 34 67-68 370m 130m 230m 120m 120m 80m 110m 50m 240m 130m
27-30 53-60 6 11-12 1 2 1 1 7 1 27-28 55-56 29 57-58 30 59-60 390m 150m 240m 140m 120m 90m 110m 50m 250m 140m
23-26 45-52 5 9-10 1 2 1 1 6 - 23-24 47-48 25 49-50 26 51-52 410m 160m 250m 150m 130m 100m 120m 60m 270m 150m
19-22 37-44 4-5 8-9 1 2 1 1 5 1 19-20 39-40 21 41-42 22 43-44 410m 170m 250m 160m 130m 110m 120m 60m 270m 160m
15-18 29-36 3-4 6-7 1 3 2 1 4 - 15-16 31-32 17 33-34 18 35-36 430m 190m 260m 180m 140m 120m 120m 70m 280m 190m
11-14 21-28 3 5-6 1 3 2 1 3 - 11-12 23-24 13 25-26 14 27-28 430m 210m 260m 200m 140m 130m 120m 80m 280m 210m
7-10 13-20 2 3-4 1 3 3 1 2 - 7-8 15-16 9 17-18 10 19-20 450m 250m 280m 240m 140m 160m 130m 90m 290m 240m
3-6 5-12 1-2 2-3 1 4 3 1 1 - 3-4 7-8 5 9-10 6 11-12 450m 290m 280m 270m 140m 180m 130m 100m 290m 280m
1-2 1-4 1 1 1 4 or 1* 4 or 1* 1 - - 1 1-2 2 3-4 470m 340m 290m 320m 150m 210m 130m 120m 300m 330m
Single Double Single Double Single Double Single Double Single Double Single Double A B A B A B A B A B
M2231.-.
M2230.-.
or
Apartment No.
station
No.
or
Indoor
02 Planning Quick reference
M2304 M2300
or M2301
composed OS
modules
the
M251021C M251021P4 51021DN
x1
The article no. of
M251021A-. M251022A-. M251023A-. 51022CF
are shown in the
rightt
Below apartment no. is composed by selected push
system controller
module and the selected audio module
x1
button
x1
41022F
-. +
51023CF
41023F
-. +
51024CF
41024F
-. +
51028CF
41028F
-. +
distributor
Video
No.
controller
System
sontroller or mini
standard system
station fed by
No. of video
outdoor
Camera
Module
Module
Button
Nameplate
Module
Audio Module Cover Frame & Flush-mounted Box
Video Outdoor Station Composed by 4-row Button Modules Distance range and cable type
The mixed power solution for keypad outdoor station with display
Building <=250 apartments
Apartment No. =Indoor station No.
Audio system with audio keypad outdoor station with display --- without auxiliary power supply A B A B A B A B A B
1-24 - 2 24 - - - - - - - - - 650m 390m 610m 370m 410m 240m 230m 140m 640m 370m
25-60 - 1 60 - - - - - - - - - 650m 210m 610m 200m 410m 130m 230m 70m 640m 200m 61-96 - 1* 96 - - - - - - - - 650m 140m 610m 130m 410m 90m 230m 50m 640m 140m
Audio system with audio keypad outdoor station with display --- for auxiliary power supply B B B B B
Audio system with audio keypad outdoor station with display --- with auxiliary power supply A1** B A1** B A1** B A1** B A1** B
97-158 - 2 - - 79 - 79 - - - - - 650m 170m 610m 160m 410m 100m - - 640m 160m 159-237 - 2 - - 79 - 79 - 79 - - - 650m 170m 610m 160m 410m 100m - - 640m 160m 238-250 - 2 13 - 79 - 79 - 79 - - - 650m 170m 610m 160m 410m 100m - - 640m 160m
Video system with video keypad outdoor station with display, indoor station is 4.3 video handset/hands-free or audio handset.---without auxiliary power supply
9 3 2 9 3 - - - - - - - - 390m 310m 240m 300m 120m 200m 110m 110m 250m 300m 10-43 11 1 43 11 - - - - - - - - 390m 170m 240m 160m 120m 110m 110m 60m 250m 160m 44-76 19 1* 76 19 - - - - - - - - 330m 120m 200m 110m 110m 80m 90m 40m 220m 110m
Video system with video keypad outdoor station with display, indoor station is 4.3 video handset/hands-free or audio handset.---for auxiliary power supply
- - - - - 63 16 - - - - - - - 140m - 130m - 90m - 50m - 130m
Video system with video keypad outdoor station with display, indoor station is 4.3 video handset/hands-free or audio handset---with auxiliary power supply
77-103 26 1 40 10 63 16 - - - - - - 240m 140m 150m 130m 80m 90m 150m 130m
104-126 32 2 - - 63 16 63 16 - - - - 260m 140m 160m 130m 80m 90m - - 170m 130m
127-189 48 2 - - 63 16 63 16 63 16 - - 260m 140m 160m 130m 80m 90m - - 170m 130m 190-250 63 2 - - 63 16 63 16 63 16 61 16 240m 140m 150m 130m 80m 90m - - 150m 130m
Remarks: * means the outdoor station(s) are all fed by local power supply, and the power of system controller is used purely to power the indoor stations. Please be noted that the total cable length of the system should be less than 800 meters. **means the Max. distance from futhest outdoor station to the furthest indoor station/gateway under one auxiliary power supply. Unit:m
In case each building should be connected into a residential complexes, a building gateway with 5 consumer units should be considered, which will
»
result in:
1) 5 less audio indoor station in audio system for the standard system controller. Eg. A max. of 55 audio indoor stations with 1 audio keypad outdoor station can be powered by one system controller plus a building gateway.
2) 4 indoor stations and 1 video distributor in video system for the standard system controller. Eg. A max. of 72 video indoor stations with 18 video distributors and 1 video keypad outdoor station(fed by mini local power supply) can be powered by one system controller
In case several auxiliary power supplies or several standard system controller with building gateway are used, if possible, it is recommended to power
»
the same amount of devices for each auxiliary power supply or system controller.
Standard System Controller
Total
How many OS fed by standard system controller
Apartment No. with 1indoor station/ apartment
distributor No.
- - - 79 - - - - - - - - 170m - 160m - 100m - 60m - 160m
How many distributor
1st Standard Auxiliary Power Supply
How many
How many
apartment.
distributor with 1indoor station/ apartment
2nd Standard Auxiliary Power Supply
How many apartment. with 1indoor station/ apartment
How many distributor
3rd Standard Auxiliary Power Supply
How many
How many
apartment.
distributor with 1indoor station/ apartment
4th Standard Auxiliary Power Supply
How many
How many
apartment.
distributor with 1indoor station/ apartment
Fig.58 Fig.59
Fig.85
Cable type and distance A:Max. distance from outdoor station to the furthest indoor station A1:Max.distance from outdoor station to the furthest gateway B: Max. distance from furthest system controller to the furthest indoor station
Coax, 75-5 RVV,
A B A B A B A B A B
A1** B A1** B A1** B A1** B A1** B
Ø=1 mm,
B B B B B
J-Y(ST)-Y, Ø=0.8 mm,
J-Y(ST)-Y, Ø=0.6 mm,
UTP 5, 2 x 2pairs
For each one of video parallel OS, for A, below amount of distance should be subtracted.
50m 30m- - - - -20m 20m 40m
51021J
Coax, 75-5 RVV,
Ø=1mm,
Y,Ø=0.8mm,
J-Y(ST)-
Y,Ø=0.6mm,
J-Y(ST)-
UTP 5, 2 x
2pairs
51025CF
41025F
-. +
51026CF
41026F
-. +
51029CF
41029F
-. +
41024F +
51024CF
-. +
A=From one or parallell outdoor stations to the furthest indoor station
B=From system controller to the furthest indoor station
For building with more than 250 apartments, it can be handled by using gate station as the apartment outdoor station, and splitting the whole building into several sections with section connected by one building gateway .
Building <=250 apartments
Total apartment No. =Indoor station No.
251-315 80 2 - - 63 16 63 16 63 16 63 16 63 16 - -
316-378 96 2 - - 63 16 63 16 63 16 63 16 63 16 63 16
Total distributor No.
Standard System Controller
How
Apartment
many OS
No. with
fed by
1indoor
standard
station/
system
apartment
controller
How many distributor
1st Building Gateway+ Standard System Controller
How
How
many
many
apartment.
distributor with 1indoor station/ apartment
2nd Building Gateway+ Standard System Controller
How
How
many
many
apartment.
distributor with 1indoor station/ apartment
Fig.7
3rd Building Gateway+ Standard System Controller
How
How
many
many
apartment.
distributor with 1indoor station/ apartment
4th Building Gateway+ Standard System Controller
How
How
many
many
apartment.
distributor with 1indoor station/ apartment
5th Building Gateway+ Standard System Controller
How
How
many
many
apartment.
distributor with 1indoor station/ apartment
6th Building Gateway+ Standard System Controller
How
How
many
many
apartment.
distributor with 1indoor station/ apartment
Cable type and distance A1: The max. distance from outdoor station to the furtherst gateway B: Max. distance from furthest stem controller to the furthest indoor station
Coax,
R VV,
J-Y(ST)-
J-Y(ST)-
75-5
Ø=
Y,Ø=
1mm,
0.8mm,
A1 + B A1 + B A1 + B - A1 + B
240m
150m
+
130m
150m
+
130m
80m
90m
80m
90m
+
+
140m
240m
140m
+
+
Y,Ø=
0.6mm,
-
-
UTP 5, 2 x 2pairs
General Remarks :
In case more keypad outdoor stations are needed, each additional outdoor station should be powered by local power supply, the distance will
»
impacted. In case one video distributor does not support 4 indoor stations, please base on one standard auxiliary power supply can feed total 79 units to count
»
the capacity (84-5 units of gateway) For example it can be 52 indoor stations plus 26 video distributors with one supporting 2 indoor stations. In case parallel indoor stations are present, please base on the power consumer units calculation rule to count the capacity in Table 1 and Table 2.
»
150m
130m
150m
130m
+
+
82 | ABB-Welcome
ABB-Welcome | 83
Page 43
Fig.84
Keypad outdoor station solution example: One building with 3 keypad video outdoor station with display, total 240 apartments, each auxiliary power supply with 60pcs 4.3" hands-free indoor station
03 Installation
03 Installation
Following is general information for the installation of an ABB Welcome system in new and existing buildings. The installation of flush-mounted and surface-mounted devices as well as MDRC units and Kit is described in detail in the operating manuals of the devices. There will have video describing the installation in more detail.
Installation instructions for new buildings
The following should be ensured when setting up a reliable, simple, economical and future-oriented Welcome system:
»
Despite many kinds of cables are workable for the Welcome system, the distance subjects to the type of cable used, please check the page 64 to select the correct cable to the given project.
»
For small systems: Looping the internal bus from device to device is recommended.
»
For high rising building: setup of a structure with a rising mains is recommended.
»
For small networked system. Looping trunk line from one villa/building to next villa/building through gateway is recommended. If two or more trunk lines are provided, many internal bus lines can be used. But please pay attention to the distance restraint of this topology to keep the sum of the wiring distance smaller than 800 meters.
»
For big networked residential complex.
Branch line connections for the trunk line is recommended by gateway plus video distributor is recommended.
Please check chapter 2 for the distance and capacity for all above mentioned scenarios.
Welcome audio system should make later conversion to video easy. The conversion includes the exchange of at least one audio outdoor station with a video outdoor station and at least one audio indoor station with a video indoor station. The system controller needn't not be replaced. However, if the total power consumption of the conversed system exceeds the capacity of the original system controller, additional bus power supply(gateway + system controller) should be put in the bus.
For branch connections in the system, video distributors must be installed for the conversion. This is very important, If not, the conversion will become very time-consumping, as even the exchange of one audio indoor station with one video indoor station will require a total change of the original node connection into branch line connection by video distributor. These are not required in the internal bus – if it is looped from device to device. The setting of the terminal resistors of the system must be checked after the conversion. (see page 55-58)
84 | ABB-Welcome
ABB-Welcome | 85
Page 44
03 Installation
Installation instructions for modernization
The modernization of a building is an ideal opportunity for replacing an existing door entry system with a Welcome system within the design of the other electrical installations.
Here, as a rule – independent of the type of wiring of the old system (pure bell system, system with "1+n“ technology or comparable systems with 2-wire bus technique) – existing lines can be used. In case of existing cable material a possible reduction of the transmission range is to be checked.
Conversion of old bell systems in one-family houses to Welcome
Available:
» At the door: one button » Indoors: one door bell » In the sub-distribution: one transformer for the door bell and
the name plate
The conversion of the bell system in a one-family house to Welcome system is easy if a cable is available from the front door to the distribution and a cable from the distribution into the building, e.g. in the hallway. This layout is used by the system controller, outdoor station and indoor station.
The conversion of old bell and intercom systems to ABB­Welcome ("1+n" technique, with coaxial cable for video if necessary) The multifamily house has available:
» At the door: bells (with "1+n" wiring) + loudspeakers /
microphones
» Indoors: in each apartment, one indoor station
with door bell and a button for opening the front door
» In the sub-distribution: one bell transformer for
the buzzer/electronic door opener, one transformer for the house telephones
For systems with "1+n" wiring as rising mains installation with branch connections to the indoor stations only two wires are required from the multi-wire cable. The indoor stations of the ABB-Welcome system are also connected to the rising mains via the branch line. For a video system one indoor FM video distributor should be installed in the branch box.
Fig.86
This enables buildings with only a bell system to be retrofitted with audio or video system.
86 | ABB-Welcome
ABB-Welcome | 87
Page 45
Fig.86
Conversion of "1+n"system to Welcome (Including audio system and video system)
03 Installation
Existing“1+n" system
Installation of the outdoor stations
The composition process from modules into an outdoor station is screwless and convenient. The direction to snap the module should be heeded. A "click" sound will be heard when the module is well placed. The installation video is available to see the whole process.
Fig.87
For all outdoor stations an installation wall box is available for flush-mounting. The rainy hood serves as surface-mounting box as well as the device to protect dirt, water or snow falling on the camera lens. Flush-mounting is suitable for all types of walls, whether rendered, clinker or cavity wall. because the installation box has a full perimeter frame. For flush-mounting in a cavity wall (thickness between 2 and 25 mm), the glass glue or similar adhesive material is recommended to seal and adhere the flush box and wall.
Fig.88
In case a 10-module frame and box are not enough for the actual application, the conjunction by 3 or more 4-module frame and flush box by jointing fixture is possible. However, the rainy hood is only available 3 pcs of 4-module frames in horizontal connection.
Fig.89
For dismantling the end strip, a distance of 1 cm should be kept to the right of the outdoor station.
Fig.90
The camera has a large detection angle . The view area can be manually adjusted by a simple tool with range of +15 ,-15 at all direction.
Fig.91
Note: The camera of the video outdoor station
should not face powerful light sources, such as street lights. This should be taken into consideration when choosing the correct position for mounting. Lamps in the entrance area should uniformly illuminate the face of the visitor. The recommended installation height is 1.50 m. This optimally captures persons of average body size. Bright or backgrounds with a deep contrast should be avoided. It could reduce the quality of the picture.
88 | ABB-Welcome
Conversion for audio system Conversion for video system
Fig.87
Composition of outdoor station Flush-mounting box installation
Fig.88
ABB-Welcome | 89
Page 46
Fig.89
The conjunction of 3 pcs of 4-moudle outdoor stations
03 Installation
Fig.90
The distance zones for the installation of the outdoor station
Installation of indoor stations
The Welcome audio indoor station and video 4.3" handset indoor station and 7" video handsfree indoor station are easy to install as a surface mounted device with the aid of the enclosed mounting frame. The devices can also be mounted on a commercially available VDE or Italian( or equirement) flush
Fig.92
mounted wall box.
Fig.93 Fig.94
The 4.3" video hands-free indoor station can be installed in the design of 5 various easily changeable color frames so to comply with or contrast the decoration color in an apartment. Both surface mounted and flush mounted are possible. For surface mounted, the device can be mounted on VDE/ Italian( or equirement) flush mounted wall box. For the flush mounted version, a metal flush box is recommended to ensure the efficient and sleek installation. For flush-mounting in a cavity w a l l (thickness between 0.2 and 2.54cm),a cavity wall mounting set consisting of mounting anchors is available.
Fig.95
Note: In order to enable disabled people to use and set video
handsets, we recommend an installation height of 120-125 cm.
Additional information is contained in the operating manuals. The associated QR codes are listed starting from page 106.
Installation of system devices
Recommendation: All MDRC units should be mounted in the central distribution of the building. This can be fixed depending on the size of the building and topology selected.
Fig.96
For example, when installing an auxiliary power supply in the sub-distribution of the apartment, for connecting the devices.
The ABB-Welcome indoor video distributor is suitable for mounting in rising mains below a door bell button in a deep flush-mounted wall box.
Fig.97
Fig.91
Mechanical adjustment and detection angle of camera
90 | ABB-Welcome
Fig.92
Surface mounted and desktop of 7” video hands-free indoor station
ABB-Welcome | 91
Page 47
Fig.93
Surface mounted and desktop of 4.3" video handset indoor station
Fig.94
Surface mounted and desktop of audio handset indoor station
Fig.95
Surface mounted, desktop mounted and flush mounted of 4.3’’ video hands-free indoor station
04 Commissioning
04
Commissioning
Well-prepared for everything. Several settings need to be made
prior to the installation of a Welcome system. These can be carried out by the electrical installer already at the factory, so that the devices can be directly installed at the customer's premises.
Fig.96
Mounting of the MDRC devices
Setting the address of the outdoor station:
The allocation to one of the nine inputs of the Welcome system is made at the outdoor stations and the associated switch actuators for lock and light via the setting of the address.
Here the rotary knob house/outdoor is set on an address between 1 and 9. The knob is located at the rear of the outdoor station.
Fig.98
Rotary knob for setting the address of an outdoor station
Fig.98
Setting the button sounds on/off:
At the outdoor stations the acoustic feedback signal is switched on and off via the "TT" button sounds switch when a push button is pressed. The switch is located at audio module of outdoor station.
Fig.97
Mounting of the video distributor
92 | ABB-Welcome
Address: Address of outdoor station
TT: Button sounds(ON=active)
S/D: Single or double button for one row(ON=double buttons)
MODE: Working mode of 1st/ 2nd button
ABB-Welcome | 93
Page 48
04 Commissioning
Overview of the different setting options
Device Setting Note
ABB-Welcome outdoor station Address of the outdoor station
Button sounds on/off
Single or double button for one row
"MODE"switch for 1st/2nd button
Volume from indoor station to outdoor station
Setting of door lock release time
Setting of the video signal format
ABB-Welcome indoor station Address of the indoor station
Only if several outdoor
Setting of the default outdoor station stations are used in the one
system
Setting of the master indoor station
Setting of the terminal resistor
ABB-Welcome system controller Setting of the system working mode "One on "or "All on"
ABB-Welcome gateway Address of gateway
Setting of the working mode of gateway
Setting of the terminal resistor
ABB-Welcome switch actuator Address of switch actuator
Setting of working mode of switch actuator
Setting of the terminal resistor
Setting of the door opener time and light time
ABB-Welcome video distributor Setting of the terminal resistor
ABB-Welcome guard unit Address of guard unit
Setting of the standard outdoor
Setting of the master guard unit
Setting of the terminal resistor
Setting the single or double button for one row
Fig.99
In case the push button is present on the outdoor station, once the single or double buttons for one row is set on "S/D" switch, all the push button modules on the outdoor station will behave the same manner, either one button for each of all the button modules or double buttons for each of all the button modules
Setting the "MODE" switch for 1st/2nd button
Fig.100
For each row of push button, both in single button and double buttons scenarios, 4 modes are possible to set the function of first and second button. When switching the light is desired, the switch actuator is needed to enable the function.
Setting of indoor station->outdoor station volume
The volume from all the indoor stations to outdoor station during communication can be set on the sliding switch in case the outdoor station is installed in the noisy area.
Setting of door lock release time
This setting determines the operating period of the door lock (from one to ten seconds).
Setting of the video signal format
Fig.101
The setting allows selection of the standard of the video signal of the system, either PAL or NTSC. PAL Standard video 50 Hz NTSC Standard video 60 Hz The jumper is located on the back of the camera module.
94 | ABB-Welcome
ABB-Welcome | 95
Page 49
2
ON
S/D 1
2
3
4
2
ON
S/D 2468135
7
2
3
ON MODE
4
S/D 1
2
3
4
3
ON MODE
4
S/D 1
2
3
2
3
ON MODE
4
S/D 1
2
3
2
3
ON MODE
4
S/D 1
2
Fig.99
1. Setting of single button
04 Commissioning
2. Setting of double button
Fig.100
Setting of mode for 1st and 2nd button
1. Setting of not extra function
2. Setting of lighting
Setting the address of the indoor station:
Fig.102
At the indoor stations the apartment is assigned via the setting of the address. Up to 250 apartments can be addressed within a Welcome system.
For handset indoor station, the address of an indoor station (e.g. "024") is set with the aid of the jumpers "X100","X10" and "X1" at the indoor stations, where "X100" specifies the hundreds digit (here "0"), "X10" the tens digit (here "2") and "X1" the units digit (here "4"). The jumpers are located at the rear or outside of the indoor stations.
For 4.3" hands-free indoor station, the address of an indoor station (e.g."024") is set with the aid of the rotary knobs & dip-switches "X200","X100","X10" and "X1" at the indoor stations, where "X200" & "X100" specifies the hundreds digit (here "off"), "X10" the tens digit (here "2") and "X1" the units digit (here "4").
Attention that, for 7" hands-free indoor station, if address is more than 99, the setting must be done when entering system setting and "X10" & "X1" is set as "0".
Setting of the "default outdoor station"
For several outdoor stations in a Welcome system the “default outdoor station" must be set at the indoor stations and guard unit. Here the rotary knob STATION is set on the address of the standard outdoor station – between 1 and 9. For handset indoor station, the setting is done with the aid of jumper. The rotary knob or jumper is located at the rear or outside of the indoor stations.
Setting of the master indoor station
In each apartment the switch "M/S" must be activated at one indoor station. This means "M/S=ON". For additional indoor stations in the apartment the switch here must be on "M/S=OFF". The master/slave setting is on all indoor stations as well as guard unit. The switch is located at the back of the indoor stations and guard unit.
Setting of the terminal resistor
The terminal resistor "RC" in Welcome audio systems is always switched to "RC=OFF". For video systems, the terminal resistors are to be switched to "RC=ON" for the last devices of a branch and to "RC=OFF" for all others.
3. Setting of call guard unit 4. Setting of both call guard unit and lighting
Fig.101
Setting of video signal format.
Fig.102
1. Setting of 4.3" video handset indoor
3. Setting of 4.3" video hands-free indoor
The terminal resistors are set via the switch "R/C" on all indoor stations as well as guard unit, video indoor distributors, switch actuator and gateway.
2. Setting of audio handset indoor station
4. Setting of 7" video hands-free indoor
96 | ABB-Welcome
ABB-Welcome | 97
Page 50
04 Commissioning
Setting of the system controller working mode "One on" or "All on"
Fig.103
System working mode "One on" or "All on" is controlled by system controller. If in "One on" mode, when there's an incoming call, all indoor stations in the same apartment ring together, but only master indoor station switches on screen. If in "All on" mode, when incoming call, all indoor stations in the same apartment ring and switches on screen together. (refer to illustration on page 36)
All indoor stations which are powered by the same system controller follow this rule.
Setting the "MODE" for gateway
Fig.104
At the gateway, the building no. or apartment no. is assigned via the setting of the address according to different working mode of gateway. 5 modes are possible to set the function of gateway.
» Building gateway (MODE:1->OFF, 2->OFF, 3->OFF)
-Enable one building as an independent subsystem( outdoor station/guard unit can be connected), support up to 60 such systems within the whole system.
Refer to page 41.
» Floor gateway (MODE:1->OFF, 2->OFF, 3->ON)
-Enable multi-apartments as an independent subsystem ( another outdoor station can be connected, for example in
front of the door of floor with multi-apartments). Refer to page 42.
» Apartment gateway (MODE:1->OFF, 2->ON, 3->OFF)
- Enable one apartment as an independent sub-ystem(2nd confirmed outdoor station can be connected), support up to 99 such systems within the whole system. Refer to page 44
» Additional power supply mode (MODE:1->OFF, 2->ON, 3- >ON).
- Enable a system controller to provide additional power
source for system. Refer to page 44.
» Line amplifier (MODE:1->ON, 2->OFF, 3->OFF)
- Strengthen the video signal and extend transmission
distance. The increased distance please refer to Page 44.
Setting the address of the gateway
At the gateway, the building no. or apartment no. is assigned via the setting of the address according to different working modes of gateway.
Building gateway - the address is equal to the riser number. Floor gateway - address is equal to the minimum
address of the indoor station inside the sub-system.
Fig.105
Apartment gatewy - address is equal to the apartment
number. There is no need to set address for auxiliary power supply and line amplifier.
Setting the "MODE" for switch actuator
Fig.106
3 modes are possible to set the function of switch actuator.
» Call repetition (MODE:2->OFF, 3->OFF)
Switch actuator is enabled upon an incoming call to control an external bell or light. The device is disabled after the call is answered or after a customized time out (adjusted from 1 to 30 seconds).
» Door opener (MODE:2->OFF, 3->ON)
Switch actuator is enabled by pressing unlock button of indoor stations / guard units, to release a lock connected. The device is disabled after a customized time out (adjusted from 1 to 10 seconds).
» Time relay (MODE:2->ON, 3->OFF)
Switch actuator is enabled by pressing program button of indoor stations/ guard units or light button of outdoor station in the same sub-system, to release a lock connected or switch on a light. The device is disabled after a customized time out (adjusted from 1 second to 5 minutes). Please refer to page 48 for the illustration of above function.
Setting the address of the switch actuator
The address of the switch actuators is associated with the outdoor station or indoor station which controls the actuator. Up to 199 switch actuators can be addressed in one system.
Fig.103
Setting of working mode on system controller/ mini system controller Setting of gateway for different working mode
Fig.104
The address of a switch actuator (e.g. "001") is set with the aid of the rotary knobs & dip-switch "X100","X10" and "X1", where "X100" specifies the hundreds digit (here "off"), "X10" the tens digit (here "0") and "X1" the units digit (here "1").
Fig.107
Setting the address of guard unit
The commissioning of guard unit is same as 4.3” video handset indoor station, except the valid address for guard is only 9.
Fig.108
User can use the USB connector for the connection to the PC: download/upload the configuration. e.g. download the contact lists.
98 | ABB-Welcome
ABB-Welcome | 99
Page 51
Fig.105
Setting address of floor gateway
Setting the IP-Gateway & APP
The IP-Gateway is be configured by the PC, which is connected in the same network with IP-Gateway by a router. User can set the address of the associated indoor station with the IP-Gateway, also the default outdoor station address, and others. Meanwhile, user can set the different permission of each paired APP in the “APP Management” menu.
Fig.110
Fig.109
Also, firmware update, data and time setting, configure ComfortTouch and others can be done by the web browser.
Fig.109
Fig.106 Fig.107
Setting mode of switch actuator
Fig.108
Setting address of switch actuator
Setting the address of guard unit
Fig.110
100 | ABB-Welcome
ABB-Welcome | 101
Page 52
05 Operation
05
Operation
Always intuitively correct. ABB-Welcome system makes this
possible from the very first contact. Because the eyes, hands and ears quickly orient themselves. In this way the intelligent system fulfills individual wishes and requirements.
Operating the outdoor and indoor stations
The outdoor and indoor stations are operated intuitively. Familiar style elements and easy-to-understand icons are used. For the 7" all touch and 4.3" hands-free and 4.3" handset indoor station, the menu structure is used. The functions of all devices are described in the respective operating manuals, which can be scanned from the QR code either from the quick guide or from the screen of the device under "information".
System behavior
Optional connection activation.
The advanced technology of Welcome system offers the user a large variety of options. A connection can be established by ringing the button at the second-confirmed outdoor station or apartment outdoor station or gate station. Or it can be established at the indoor station by switching on the microphone and/or the camera of the outdoor station. A connection lasts at most two minutes after which it is automatically terminated.
station(second-confirmed outdoor station, apartment outdoor station, gate station or guard unit) always have a higher priority than the connections that are established between two indoor stations-intercom. This means that an existing intercom will be interrupted as soon as the bell is rung from outdoor station.
» In case an existing connection between outdoor station and
indoor station is established, a new connection(intercom) will not be established, however, an occupied status of the system is displayed at the indoor station
Simultaneous connection and setting.
To achieve a comfortable user experience, the door bell button can be rung irrespective of an existing connection between outdoor station and indoor station or between one indoor station and the other indoor stations. In the case of parallel indoor stations in the same apartment, all indoor stations will ring at the same time for the door bell. A third indoor station in the building can be still under setting without interrupting the door bell and existing connection.
Fig.111
Fig.112
Simultaneous connection and setting.(1+1+1) .
A maximum of one apartment is being called(can be the connection between outdoor station and indoor station, or the indoor station and the other indoor station), one apartment is rung by door bell button, and one indoor station is under setting at the same time.
Apartment 4: During the moment all other three apartments are under simultaneous working, no activity can be done
Apartment 2: Connection between outdoor station and indoor station, or intercom
Apartment 3: Connection between both indoor stations and door bell button
Apartment 1: Setting can be operated at one indoor station, the other indoor station is idle.
Connection priority.
To guarantee that no call of a visitor is missed at an outdoor station, the following simple rule applies.
» Connections that are established at the outdoor
102 | ABB-Welcome
ABB-Welcome | 103
Page 53
06
Overview of product range
06 Overview of product range
06 Overview of product range
Camera module
Features
» Scratch and fire resistant finish » Video camera with large detection angle (H 86°,V 67°, D
104°) and manually mechanical adjustment (H ± 15°, V ± 15°)
» Anti-fog design with in-built heater » Built-in infrared lighting ensures clear picture at night » Secret "surveillance" enables users to surveil one area
through the camera of the outdoor station, whose backlight
will not be switched on
» Optional to connect one additional output of camera for
surveillance inside the video indoor station
» Optional to choose the standard of the video signal, either
PAL or NTSC (according to the local power frequency) for clear video quality
Audio module
Features
» 1 output for door opener without the need of additional
power supply
» 1 output for floating output, door opener (30V AC/DC 1A) » 1 input for door status check » 1 input for exit pushbutton » 2 options: aluminum brush and white coating » 4 options of functions: audio without pushbutton,
audio with 1 row of pushbutton, audio with 2 rows of
pushbuttons, audio without pushbutton but with speech
synthesis
» 3 led indications: call established / system busy,
communication possible, door unlocked
» Adjustable feedback ringtone of pushbutton » Adjustable lock release time » Adjustable speaker volume » Integrated optic sensor for day/night mode » Mode setting for the first/second button as switch on
lightings, call indoor station or call guard unit
» Mode setting for pushbutton as single column or double
columns
Pushbutton module
Features
» Two options of article: 3 rows and 4 rows » Two options: single column or double columns » Extractable nameplate by tool without the need to
disassemble the panel
» Backlight ensures clear visibility at night » UV resistant
Keypad module
Features
» Name scrolling by up and down or by inputting letters of
the calling name (display must be accompanied, sorting is progressive upon inputting next letter of name)
» The calling code can be numbers only or the combination
of numbers and letters
» Call can be activated automatically or by pressing after
inputting code
» Download name directory from PC or directly enter to edit
from the keyboard
» Up to 3,000 names » Public password and up to 6,000 customized passwords
are allowed
» Repeatedly inputting wrong password will be locked » Password can be set with 6~8 digits » Calling code can be set with 1~6 digits » Call guard unit is available » Backlight ensures clear visuality at night
Technical data
» Waterproof: IP 54, vandal proof: IK 07. » Operation temperature: -40 °C – +70 °C; -40 °F – 158 °F » Bus voltage: 20-30 VDC
QR code service
104 | ABB-Welcome
Technical data
» Waterproof: IP 54, vandal proof: IK 07. » Operation temperature: -40 °C – +70 °C; -40 °F – 158 °F » Power supply, door opener (Lock-GND): 18 V 4 A
impulsive, 250 mA holding
» Floating output: door opener (COM-NC-NO): 30 V
AC/DC,1 A
» Single-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Fine-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Bus voltage: 20-30 VDC
QR code service
Technical data
» Waterproof: IP 54, vandal proof: IK 07 » Operation temperature: -40 °C – +70 °C; -40 °F – 158 °F » Bus voltage: 20-30 VDC
QR code service QR code service
Technical data
» Waterproof: IP 54 vandal proof: IK 07 » Operation temperature: -40 °C – +70 °C; -40 °F – 158 °F » Bus voltage: 20-30 VDC
ABB-Welcome | 105
Page 54
06 Overview of product range 06 Overview of product range
Display module
Features Features
» 2 options for in-built RFID proximity reader: ID card and IC
card
» Wiegand output available » Up to 3000 different cards » Register and delete cards locally in setting menu » Different feedback sounds when accepting or rejecting the
reading card
» Customized message is programmable » Withstand down to -40 °C
Nameplate module
» It can be used to hold the address of the building or the
resident directory for keypad outdoor station, or simply to complete the module within the cover frame
» Backlight ensures clear visibility at night
7" video hands-free indoor station
Features
» Large 17.8 cm (7") color display with intuitive touch
control
» 6 touch film buttons for communication, unlocking, mute,
programmable button (can be set as intercom, call guard unit, etc.), surveillance and setting
» During resident's absence, voice message of the resident
will be played automatically in case of door calls, and 3 pictures of the visitor will be automatically stored
» The no. of pictures that can be stored is decided by the
capacity of the SD card (not provided)
» Call transfer among different apartments and guard unit is
available
» Doctor function for automatic unlock » 5 ringtones for different call sources, i.e. from default
outdoor station, secondary outdoor station, door bell,
intercom or guard unit
» Send SOS alarm to guard unit in emergency » Surface mounting and desktop mounting » The detailed user manual can be downloaded though
scanning the QR code on the screen
4.3" video hands-free indoor station
Features
» 4.3" color display with OSD » 6 touch film buttons for communication, unlocking, mute,
programmable button (can be set as intercom, call guard unit, etc.), surveillance and setting
» 2 pictures of the visitor will be automatically stored in the
picture memory for door calls during resident's absence
» The no. of the pictures is up to 60 pcs » Call transfer among different apartments and guard unit is
available
» Doctor function for automatic unlock » 5 ringtones for different call sources, i.e. from default
outdoor station, secondary outdoor station, door bell,
intercom or guard unit
» Broadcast by simply long pressing the communication
button
» Surface mounting, flush mounting and desktop mounting » The detailed user manual can be downloaded though
scanning the QR code on the screen
Technical data
» Waterproof: IP54, vandal proof: IK07 » Operation temperature: -40 °C – +70 °C; -40 °F – 158 °F » Bus voltage: 20-30 VDC
QR code service QR code service
106 | ABB-Welcome
Technical data
» Waterproof: IP54, vandal proof: IK07 » Operation temperature: -40 °C – +70 °C; -40 °F – 158 °F » Bus voltage: 20-30 VDC
Technical data
» Display resolution: 800 x 480 » Display size: 7" » Operating temperature: -10 °C - +55 °C;14 °F – 131 °F » Protection: IP 30 » Single-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Fine-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Bus voltage: 20-30 VDC
QR code service QR code service
Technical data
» Display resolution: 480 x 272 » Display size: 4.3" » Operating temperature: -10 °C - +55 °C;14 °F – 131 °F » Protection: IP 30 » Single-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Fine-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Bus voltage: 20-30 VDC
ABB-Welcome | 107
Page 55
06 Overview of product range 06 Overview of product range
4.3" video handset indoor station
Features
» Slim indoor station with handset (depth of 45 mm) » 4.3" color display with OSD » 6 touch film buttons for communication, unlocking, mute,
programmable button (can be set as intercom, call guard unit, etc.), surveillance and setting
» 2 photos of the visitor will be automatically stored in the
picture memory for door calls during resident's absence
» Up to 25 photos » Call transfer among different apartments and guard unit is
available
» Doctor function for automatic unlock » 5 ringtones for different call sources, i.e. from default
outdoor station, secondary outdoor station, door bell,
intercom or guard unit
» Surface mounting and desktop mounting » The detailed user manual can be downloaded through
scanning the QR code on the screen
Audio handset indoor station
Features
» 1 easy pushbutton for unlock, and 2 additional buttons for
self setting functions, e.g. intercom, door status check,
second lock release or even calling the security guard, etc
» Max-mid-mute volume adjuster on the side » 2 LEDs to indicate different working status » 5 ringtones for different call sources, i.e. from default
outdoor station, secondary outdoor station, door bell,
intercom or guard unit
» The activating or deactivating of automatic unlock can
be made by simply pressing the unlock button for 10
seconds
» Surface mounted
System controller
Features Features
» Control the entire system, the "brain" of the individual
system
» Over-heat protection, over-current protection, lightening
protection
» Two working modes to switch between "all on" and "one
on"
» 1LED for normal working condition indication » Overheat, short-circuit and lightening protection » As auxiliary BUS power supply when connecting to
gateway under certain mode
Mini system controller
» Control the entire system, the "brain“ of the individual
system
» Over-heat protection, over-current protection, lightening
protection
» Two working modes to switch between "all on" and "one
on"
» 1LED for normal working condition indication » Overheat, short-circuit and lightening protection » As auxiliary BUS power supply when connecting to
gateway under certain mode
Technical data
» Display resolution: 480 x 272 » Display size: 4.3" » Operating temperature: -10 °C – +55 °C;14 °F – 131 °F » Protection: IP 30 » Single-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Fine-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Bus voltage: 20-30 VDC
QR code service QR code service
108 | ABB-Welcome
Technical data
» Operating temperature : -10 °C – +55 °C ;14 °F – 131 °F » Protection: IP 30 » Single-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Fine-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Bus voltage: 20-30 VDC
Technical data
» Operating temperature: -25 °C – +55 °C; -13 °F – 131 °F » Protection: IP 20 » Single-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Fine-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Mains voltage: 100-240 V, 50 / 60 Hz, 1.0 A » Bus voltage: 28 ± 2 VDC, 1.2 A » Size: 8 U
QR code service QR code service
Technical data
» Operating temperature: -25 °C – +55 °C; -13 °F – 131 °F » Protection: IP 20 » Single-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Fine-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Mains voltage: 100-240 V, 50 / 60 Hz, 0.6 A » Bus voltage: 28 ± 2 VDC, 0.65 A » Size: 4 U
ABB-Welcome | 109
Page 56
06 Overview of product range 06 Overview of product range
Gateway Video outdoor distributor
Features
» It offers 5 different modes which can be set by dipswitch:
apartment gateway, floor gateway, building gateway,
Features
» 2 way inputs connect different outdoor stations » Used in buildings with more than one video outdoor station
auxiliary BUS power supply interface and line amplifier
Guard unit Video distributor
Features
Features
» 4.3" touch screen and 6 touch film buttons can ensure
the communication with calls from outdoor station, indoor station or other guard unit (if any)
» It can be manually or automatically set into intercept mode
to increase security level for all users or only VIPs
» This compact device supports 4-way outputs connected to
different apartments or different high-rise buildings
» Flush-mounted into VDE/Italian box or surface mounted
through the hole in the middle
» Surveillance can be done through the camera of outdoor
stations or integrated analog camera
» Missed calls and alarm messages stored in the memory
can be reviewed
» It can be surface mounted on the wall or desktop
mounted
Technical data Technical data
» Operating temperature: -25 °C - +55 °C; -13 °F – 131 °F » Protection: IP 20 » Single-wire clamps: 2 x 0,28 mm² – 2 x 1 mm² » Fine-wire clamps: 2 x 0,28 mm² – 2 x 1 mm² » Bus voltage: 20-30 VDC
» Operating temperature: -25 °C - +55 °C; -13 °F – 131 °F » Protection: IP 20 » Single-wire clamps: 2 x 0.28 mm2–2 x 1 mm » Fine-wire clamps: 2 x 0.28 mm2–2 x 1 mm » Bus voltage: 20-30 VDC » Size: 2U
QR code service QR code service
110 | ABB-Welcome
Technical data
» Display resolution: 480 x 272 » Display size: 4.3"
2
2
» Operating temperature: -10 °C - +55 °C;14 °F – 131 °F » Protection: IP 30 » Single-wire clamps: 2 x 0.28 mm² – 2 x 1 mm²
Technical data
» Operating temperature: -25 °C to +55 °C; -13 °F – 131 °F » Protection: IP 20 » Single-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Fine-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Bus voltage: 20-30 V
» Fine-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Bus voltage: 20-30 VDC
QR code service
QR code service
ABB-Welcome | 111
Page 57
07
Connection
07 Connection06 Overview of product range
Switch actuator
Features
» 1 output for connecting an electronic lock or light » 1 output for local pushbutton » 3 working modes: extend door bell, switch on lighting,
door lock release
» The switching duration of unlock or switch on lighting is
adjustable
» Flush-mounted
IP-Gateway
Features
» Enables Smartphones (iOS and Android) and tablet by
installing the app as video indoor station
» Supports both WIFI and remote access under 3G/4G with
the help of service provider
» Enables the integration with ABB Comfort touch as indoor
station
» Enables to configure other Welcome products using a web
browser
The flexible solutions made by easy connection. ABB Welcome
system can also be easily and quickly connected for all kinds of buildings. The following examples of terminal diagrams provide optimum orientation and guarantee effective installation.
Technical data
» Operating temperature: -25 °C - +55 °C; -13 °F – 131 °F » Protection: IP 30 » Single-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Fine-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Floating output for light: 230 V AC, 3 AX » Floating output for door opener: 30 V AC/DC; 3 A » Bus voltage: 20-30 VDC
QR code service
112 | ABB-Welcome
Technical data
» Operating temperature: -25 °C – +55 °C; -13°F-131°F » Protection: IP 20 » Single-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Fine-wire clamps: 2 x 0.28 mm² – 2 x 1 mm² » Bus voltage: 20-30 VDC » Size: 10 TE
QR code service
ABB-Welcome | 113
Page 58
114 | ABB-Welcome
ABB-Welcome | 115
Page 59
Single-family house/villa
» System type: audio/video combined
» Wiring: looped from devices to devices
Multi-family, audio only
» System type: audio only
» Wiring: Branch line connection, node
» 1 entrance, 10 apartments, 1 pc of audio
handset for each apartments
116 | ABB-Welcome
ABB-Welcome | 117
Page 60
Multi-family, video
» System type: video
» Wiring: Branch line connection with video distributor
» 2 entrances, 10 apartments, 1 pc of 4.3’’ video hands-
free and 1 pc of 4.3’’ video handset for each apartment
118 | ABB-Welcome
ABB-Welcome | 119
Page 61
Multi-family, video
» System type: video
» Wiring: Branch line connection with video distributor
» 1 entrance, 60 apartments, 1pc of 4.3" indoor
stations each apartment except apartment No.1 & apartment No.2 with 1 pc of 4.3’’ video hands-free and 1 pc of 4.3’’ video handset
120 | ABB-Welcome
ABB-Welcome | 121
Page 62
Residential complex, audio/video
» System type: audio/video
» Wiring: Loop connection for the common part
» 1 gate station, 1 guard unit for the common part, 3
sub-insulated systems (audio/video)
122 | ABB-Welcome
ABB-Welcome | 123
Page 63
Residential complex, audio/video
» System type: audio/video
» Wiring: Branch line connection for the common part
» 1 gate station, 4 sub-insulated system (audio/video)
a
b
DC
GND
LOCK
COM
NC
NO
DS
Exit
a
b
L
Mains 100-240V~
N
IN
OUT1
OUT2
OUT3
OUT4
a
b
IN
OS
a
b
a
b
OUT
a
b
IN
OS
OUT
a
b
a
b
a
b
L
Mains 100-240V~
N
a
b
DC
GND
LOCK
a
b
a
b
L
Mains 100-240V~
N
COM
NC
NO
DS
Exit
a
b
a
b
a
b
a
b
a
b
DC
GND
LOCK
COM
NC
NO
DS
Exit
Address
1
124 | ABB-Welcome
TT S/D MODE
1 2 3 4
M2300
s
One on
All o n
M2304 M2302
G s
MODE
X10X 1
01
RC on
RC off
Address
2
TT S/D MODE
1 2 3 4
RC on
RC off
M2300
One on
All o n
Address
2
TT S/D MODE
1 2 3 4
G
MODE
X10X 1
02
RC on
RC of f
M2300M2302
s
One on
All o n
ABB-Welcome | 125
Page 64
Residential complex, audio/video
» System type: audio/video
» Wiring: Branch line connection with auxiliary power supply
» 1 gate station, 8 sub-insulated system (audio/video)
a b
DC
GND
LOCK
COM
NC
NO
DS
Exit
a b
a b
a b
IN
a b
OS
a b
OUT
a b
a b
IN
a b
OS
a b
OUT
a b
a b
IN
a b
OUT1
a b
OUT2
L
Mains 100-240v~
N
L
Mains 100-240v~
N
a b
OUT3
a b
L
Mains 100-240v~
N
OUT4
a b
OUT1
a b
OUT2
a b
OUT3
a b
OUT4
Address
1
126 | ABB-Welcome
TT S/D MODE
1 2 3 4
M2300
S S
G
MODE
x1x10
0 1
One on
All on
RC on
RC off
M2300 M2304M2302
One on
All on
RC on
RC off
G
MODE
0 1
RC on
RC off
M2300
M2304M2302
S
x1x10
One on
All on
RC on
RC off
ABB-Welcome | 127
Page 65
08 Technical assistant tool
08
Technical assistant tool
Welcome system provides a series of tools for installation. The technical tools can be downloaded by the given link or scanning the QR code of each tools.
Quotation software
The quotation software enables the easy and efficient system composition and quotation automatically. Three key advantages as below:
1. Can upload customized price easily for better price management.
2. Can generate possible matched modular outdoor stations(with cost and general effect)for selection.
3. Once the indoor station is also selected, the other system devices will be selected automatically.
Topology wizard
With single family house, multi-family house and high-rise building simulation application scenario to be used as the topology background, it is very easy for the designer or architect to make a "DRAWING" topology. With the Visio sharp source, the designer or architect just need to drag in or out the related device, then the desired topology is done. It is as easy as A-B-C.
Setting and wiring wizard
The Visio and CAD version product library are available to help the designer, architects and those who need the drawing etc., which will help to make the drawing and setting more efficiently. The wiring and setting will move accordingly once the product device moves.
The product library include:
» Each product device with illustration, connection terminals
and setting instruction.
» The 2-wire BUS and normal 2 wire » The sketch of the third party products, such as lock and
analog camera.
128 | ABB-Welcome
Conguration software
With configuration software, just a few data input will be enough to configuration the system.
» It enables the efficient inputting, editing and deleting
resident names for keypad outdoor station or keypad gate
station.
» It supports easy proximity card management. » It also supports uploading the data from the excel sheet
into the software.
» On-line labeling tool enables the efficient and professional
printing 3 difference names or numbers' printing, which
are for 3-row push button module or 4-row push button
module, or nameplate module.
Installation video
Besides the installation manual, below videos are available for easy and better understanding.
1. Video for assembly modules into an finished outdoor station, mounting and wiring of outdoor stations.
2. Video for mounting and wiring of indoor stations.
3. Video for mounting and wiring of system devices.
4. Video for KIT connection for easier DIY solution.
The attached QR code for the direct and easier scanning and review in mobile phone or tablet
ABB-Welcome | 129
Page 66
130 | ABB-Welcome
ABB-Welcome | 131
Page 67
Contact us
2TMC107015M0201
06-2014 SH-SO 2000