ABB T7 Catalog Page

Thermal overload relays
T ype T7 Class 10
Description
• Designed for close couple mounting for two contactors, B6 and B7
• Separate base mounting available
• Class 10 adjustable overload relays
• Reset can also be adjusted to function as a stop button
• Screwdriver guide holes
• All terminal screws are available from the front
• UL File No: E149922
• CSA File No: LR702107
• Trip indication
• Single phase and phase unbalance protection
• Isolated alarm circuit (N.O.) contact
• Ambient compensation:
-25°C to +50°C (-13°F to 122°F)
• Manual test
• Manual or automatic reset
• Factory calibrated and tested
• Wide adjustment range
Catalog number explanation
T7DU 0.16
Frame size
AC 1000.1 — 10/98
This catalog is published for information purposes only and is not all inclusive. For additional information on products or technical information, consult ABB Control Inc. The installation and use of ABB Control Inc. products should be in accordance with the provisions of the U.S. National Electrical Code and/or other local codes or industry standards that are pertinent to the particular end use. Installation or use not in accordance with these codes and standards could be hazardous to personnel and/or equipment.
ABB Control Inc.
Amp rating
1
T7DU
Thermal overload relay T7DU
For mini contactors Selection
Thermal overload relay — for contactors B6,B7, BC6, BC7, B6S, B7S, VB6(7), VBC6(7), VB6A(7A), VBC6A(/7A)
Setting range Catalog List
Amps number price
0.1–0.16 T7DU0.16
0.16–0.24 T7DU0.24
0.24–0.4 T7DU0.4
0.4–0.6 T7DU0.6
0.6–1.0 T7DU1.0
1.0–1.6 T7DU1.6 $ 32
1.6–2.4 T7DU2.4
2.4–4.0 T7DU4.0
4.0–6.0 T7DU6.0
6.0–9.0 T7DU9.0
9.0–12.0 T7DU12.0
Loading capacity of auxiliary switches
Type T 7 DU
Rated operating voltage Ue/V Thermal current A6 6 Rated operating current I
Pilot duty rating
General use
R
R
IEC / UL508
e
at AC-15 220/240 V A 1.5 1.5 at AC-15 380/415 V A 0.7 0.5 at AC-15 500 V A 0.5 0.3 at DC-15 220 V A 0.2 0.2
AC D300 D300 DC R300 R300
240V 1.5A 1.5A 600V 0.6A 0.6A
N.C. N.O.
95 – 96 97 – 98
V 500 / 300 500 / 300
Thermal overload relay T7DU
Setting range Short circuit protection (fuses, circuit breakers) Joule losses
Coordination Type 2 (IEC) Coordination Type 1(IEC) 600V, 5kA Resistance at upper
A – A A A
0.1–0.16 0.5 20 1 15A 62.3 1.6
0.16–0.24 1 20 1 15A 27 1.6
0.24–0.4 2 20 1 15A 11.7 1.9
0.4–0.6 2 20 1 15A 4.61 1.7
0.6–1.0 4 20 3 15A 1.66 1.7
1.0–1.6 6 20 6 15A 0.63 1.6
1.6–2.4 6 20 6 15A 0.27 1.6
2.4–4.0 10 20 15 15A 0.107 1.7
4.0–6.0 10 20 20 15A 0.049 1.8
6.0–9.0 10 20 35 15A 0.021 1.7
9.0–12.0 20 20 45 15A 0.010 1.4
gL/gG gL/gG
R
Fuse MCCB setting
per phase current
WW
per phase
AC 1000.1 — 10/98
2
Discount schedule MB
ABB Control Inc.
Loading...