Standard terminals for E1.2 fixed are Front. Standard terminals for E2.2 - E6.2 are Rear Horrizontal except for UL E4.2 3200A and E6.2 6000A, which are Rear Vertical
2)
Not available for UL E4.2 3200A or UL E6.2 6000A. Not UL listed.
3)
Available for E1.2 only
4)
Not available for UL E4.2 3200A or E6.2 6000A, it is their standard termination
5)
Available for E2.2 - E6.2 only
6)
Available for E2.2 IEC only; not available as factory installed with other terminal combinations
7)
Not yet available. Contact ABB
8)
Not UL listed.
Note: Additional, non-factory installed options are available.
9/2 | 1SXU200040C0201 | ABB catalog
1)
———————
—Upper Terminals
—Rear Horiz
2)
Rear Horiz
2)
3)
C
Rear VertHJ
8)
Front
3)8)
Ext Front
FcCuAl Cable
Spread Rear Horiz
Spread Rear Vert
NPQ
T UVWX——
3)8)
23456——
6)8)
—————7—
6)8)
——————8
Rear VertFront
DEFG——
4)
8)
Ext Front
3)8)
FcCuAl Cable
3)8)
KLM——
5)
RS——
Spread Rear Horiz
6)8)
Spread Rear Vert
6)8)
Page 2
Z2HFUJAE48NBEAA0QCEA
12345&67891011121314151617181920
8 — Trip Unit
Switch Disconnector
W/Std 250V Bell A larm
W/24V Digital Bell Alarm
Note: An LCD screen version trip unit is available as a separate item for Ekip Touch, Ekip Hi-touch and Ekip
G versions
1)
The Ekip Power Controller requires the use of either the Ekip Measuring or the Ekip Measuring Pro module
0———
—LILSILSIG
DIPABC
TouchDEF
1)
Touch + Power Controller
GHI
Hi-Touch—JK
1)
Hi-Touch + Power Controller
—LM
G Touch——N
1)
G Touch + Power Controller
——P
G Hi-Touch——Q
1)
G Hi-Touch + Power Controller
——R
—LILSILSIG
DipST U
TouchVWX
1)
Touch + Power Controller
YZ1
Hi-Touch—23
1)
Hi-Touch + Power Controller
—45
G Touch——6
1)
G Touch + Power Controller
——7
G Hi-Touch——8
1)
G Hi-Touch + Power Controller
——9
9 — Measuring and Power Supply
None0——
—Measuring Measuring Pro Future
—12N
Pwr Sply 24-48VDC345P
Pwr Sply 110-240VAC/ DC678Q
UTMO—ABR
EMO—CDS
UTMO + P wr Sply 24 -48VDC—E FT
UTMO + P wr Sply 110-240VAC/D C
—GHU
EMO + Pwr Sply 24-48VD C—JKV
EMO + Pwr Sply 110-240VAC/DC
Note: Ekip Hi-Touch and all Ekip G trip units are supplied with Measuring Pro as standard.
Note: Voltage outlets are installed on the bottom terminals as standard.
UTMO = Upper terminal mounting option of voltage outlets
EMO = External mounting option of voltage outlets
Future Arangement is the pre-wiring for the ability to easily add a measuring module at a future date
Ekip Synchrocheck requires the use of the Ekip Measuring Pro module.
Note: Communication, Ekip 2K and Ekip Synchrocheck modules are not usable with Ekip Dip trip units or for Switch Disconnectors. Ekip Link is compatible with all trip units, but not with switch disconnectors.
If the redundant communication plus another module is selected (D-F), the redundant module will automatically match the selected communication type of digit 10.
If two communication options are selected in digit 10, then the specific redundant module required is needed (2-7).
The maximum number of modules allowed for the combination of digit 10 and 11 is 3 for E2.2-E6.2 and 2 for E1.2.
Standard key for Same Key option is #20005. Locks with keys #20006, #20007, #20008 and #20009 are available as separate items.
Note: Key lock options for Castell and Ronis/Profalux are available for order as separate items.
ADEFGHJK
CTUVWXYZ
9
19 — 1st Racking Lock Options
NoneX———
—1st KLP-Same Keys
—ABCD
PLP Padlock
1)
Standard key for Same Key option is #20005. Locks with keys #20006, #20007, #20008 and #20009 are available as separate items.
2)
Two Castell adapters cannot be used together, but a Castell adapter can be used in either position with another style lock.
Note: The racking locks above are for E2.2-E6.2 only; for E1.2 they are located on the cradle. The supplement for locking in racked out only is located on the cradle for all breaker sizes.
EFGHJ
1)
1st KLP-Diff Keys1st KLP-Kirk/Ron/Prof 1st KLP - Castell