Measuring and Monitoring Relays
Single-phase current monitoring relays
Order number
1SVR730840R0200
1SVR740840R0200
1SVR730841R0200
1SVR740841R0200
1SVR730841R1200
1SVR740841R1200
1SVR730840R0300
1SVR730841R0300
1SVR730841R1300
1SVR730840R0400
1SVR740840R0400
1SVR730841R0400
1SVR740841R0400
1SVR730841R1400
1SVR740841R1400
1SVR730840R0500
1SVR730841R0500
1SVR730841R1500
1SVR730840R0600
1SVR740840R0600
1SVR730840R0700
1SVR730760R0400
Type
CM-SRS.11S
CM-SRS.11P
CM-SRS.11S
CM-SRS.11P
CM-SRS.11S
CM-SRS.11P
CM-SRS.12S
CM-SRS.21S
CM-SRS.21P
CM-SRS.21S
CM-SRS.21P
CM-SRS.21S
CM-SRS.21P
CM-SRS.22S
CM-SRS.M1S
CM-SRS.M1P
CM-SRS.M2S
CM-SFS.21S
Rated control supply voltage U
24 - 240 V AC/DC
110 - 130 V AC
220 - 240 V AC
Measuring ranges AC/DC
3 - 30 mA
10 - 100 mA
0.1 - 1 A
0.3 - 1.5 A
1 - 5 A
3 - 15 A
Monitoring function
Over- or undercurrent
Windows current monitoring
Latching
Open circuit or closed circuit principle
Timing functions for tripping delay
ON delay, 0 or 0. 1 - 30 s
ON or OFF delay
Output
c/o contact 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
Connection type
Push-in terminals
Double-chamber cage connection terminals
s
J J J J J J J J J J J J
J J J J J J
J J J J J J
J J J J J J J J J J J J J J J J
J J J J J J J J J J J J J J J J
J J J J J J J J J J J J J J J J
J J J J J J J J
J J J J J J J J
J J J J J J J J
J J J J J J J J J J J J J J J J J J J J J
J J J
sel sel sel sel sel sel
sel sel sel sel sel sel
adj adj adj adj adj adj adj adj adj adj adj adj
sel sel sel
J J J J J J J J
J J J J J J J J J J J J J J J J
1SVR740760R0400
1SVR730760R0500
CM-SFS.21P
CM-SFS.22S
adj: adjustable
sel: selectable
8 ABB | EPR Selection Tables 2014 | 2CDC110083C0201
Measuring and Monitoring Relays
Single-phase voltage monitoring relays
Order number
1SVR730830R0300
1SVR740830R0300
1SVR730831R0300
1SVR740831R0300
1SVR730831R1300
1SVR740831R1300
1SVR730830R0400
1SVR740830R0400
1SVR730831R0400
1SVR740831R0400
Type
CM-ESS.1S
CM-ESS.1P
CM-ESS.1S
CM-ESS.1P
CM-ESS.1S
CM-ESS.1P
CM-ESS.2S
CM-ESS.2P
CM-ESS.2S
CM-ESS.2P
Rated control supply voltage U
24 - 240 V AC/DC
110 - 130 V AC
220 - 240 V AC
Measuring ranges AC/DC
3 - 30 V
6 - 60 V
30 - 300 V
60 - 600 V
Monitoring function
Over- or undervoltage
Windows voltage monitoring
Latching
Open circuit or closed circuit principle
Timing functions for tripping delay
ON delay, 0 or 0.1 - 30 s
ON or OFF delay
Output
c/o contact
Connection type
Push-in terminals
Double-chamber cage connection terminals
s
J J J J J J J J
J J J J
J J J J
J J J J J J J J J J J J J J J J
J J J J J J J J J J J J J J J J
J J J J J J J J J J J J J J J J
J J J J J J J J J J J J J J J J
J J J J J J J J J J J J J J
adj adj adj adj adj adj adj adj
1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2
J J J J J J J J
J J J J J J J J
1SVR730831R1400
1SVR740831R1400
1SVR730830R0500
1SVR740830R0500
1SVR730750R0400
CM-ESS.2S
CM-ESS.2P
CM-ESS.MS
CM-ESS.MP
CM-EFS.2S
J J
sel sel sel sel
sel sel sel sel
sel sel
1SVR740750R0400
CM-EFS.2P
Dimensional drawings
dimensions in mm
105.9 4.17”
103.7 4.08”
adj: adjustable
sel: selectable
22.5 0.89”
85.6 3.37”
2CDC110083C0201 | EPR Selection Tables 2014 | ABB 9