3M PP User Manual

All Polypropylene Construction for Application Compatibility & Flexibility
Betafine™
PP & PG Series
All Polypropylene Filter Cartridges
Betane™ PP & PG series lter cartridges are specically engineered to achieve high throughputs for longer ltration life. Extensive testing has veried cartridge performance, subsequent lter protection and compatibility with components comply with the Food and Drug Administration’s (FDA) Code of Federal Regulations (CFR), Title 21 parts 170-199 for contact with food. Betane PP series lter cartridges are available with a 304 applications where high temperature sterilization is required. Betane PG series lter cartridges DO NOT ring. Therefore, recommended.
solvents, acids and bases. All polypropylene
stainless steel thermal reinforcing ring for
incorporate a thermal reinforcing
high temperature
sterilization procedures are not
Efficiency
Modied Oklahoma State University performance tests have been conducted to verify cartridge performance. The series lter cartridge absolute rating at ow rates not exceeding four gallons per minute per 10" element.
exhibits retention of > 99.99% at each grade’s
Betane PP & PG
Water Flow
Betane PP and PG series lter cartridges exhibit excellent water ow rates depicted in Graph 1 on the following page.
Features & Benefits
Pleated Media for Greater Surface Area
Longer service life compared to non-pleated media
Less down time due to fewer filter change-outs
Helps reduce operating costs
High Flow Rates with Lower Pressure Drops
Exceptional throughput, reduced processing time and reduced processing costs
Polypropylene Cartridge Components Free of Adhesives
Very low extractable levels for optimum filtrate purity
Broad chemical compatibility for most aggressive process applications
Thermally bonded end modifications of various styles allow for use in non-3M housings without the use of cartridge adapters
Durable construction provides long life under severe process conditions
FDA, CFR 21 Listed Materials of Construction
Suitable for a broad range of applications, including food, beverage and pharmaceutical applications
Applications
Betafine™ PP and PG series filter cartridges are ideal for a wide array of applications. Contact 3M Purification Inc. or your local distributor for assistance with your specific applications.
Chemical Processing
Pharmaceutical & Bioprocessing
Cosmetics Raw material clarification, final product clarification.
Electronics Manufacturing
Magnetic Tape Media
Photographic Film emulsions, make-up and rinse water.
1
1
High purity chemicals, solvents and reagents.
Solvents and recovery systems, glassware washers, biologicals, cough syrups, ointments, prefiltration for membrane filters and process water.
Pre-reverse osmosis water filtration, acids, etchants, photoresists and strippers.
Metal oxide dispersions, coatings and solvents.
304 Stainless Steel
1.0
0
2.0
3.0
4.0
5.0
0 4.0 8.0
Differential Pressure (psid)
Flow Rate (gpm)
060 (0.6 μm)
060 (0.6 μm)
120 (1.2 μm)
120 (1.2 μm)
250 (2.5 μm)
250 (2.5 μm)
10C (10 μm)
10C (10 μm)
500 (5.0 μm)
500 (5.0 μm)
6.0
2.0 6.0 10.0 12.0 14.0 16.0 18.0 20.0
Reinforcing Ring
(Betafine™ PP Series Only)
Polypropylene
End Cap
Adapter
Optional O-ring
Materials &
End Modifications
Polypropylene
Filter Media
Graph 1. Clean Water Flow Rate vs. Differential Pressure per 10" Filter Cartridge @ 25 ˚C
Biological Safety — Oxidizable Substances & Pyrogenicity
Betane™ PP and PG series lter cartridges were subjected to the USP 22 Class VI Safety Test in addition to Thirteen safety tests. Betane PP and PG series lter cartridges passed all safety tests listed below:
Cytotoxicity
• Direct Exposure
• Agar Overlay
• Neutral Red Uptake
• Chinese Hamster Ovary Cell
Hemocompatibility
• Human Red Blood Cell Hemolysis
• Recalcied Whole Blood Clotting Time
Safety & Histocompatibility
• USP 22 Class VI Safety Test
• Single Dose Oral Toxicity
• Single Dose Eye Irritation
• Primary Skin Irritation
• Kligman Guinea Pig Maximization
Mutagenicity
• Salmonella Preincubation (AMES)
• Human Lymphocompatibility
The Biological Safety Report for Betane PP and PG series lter cartridges is available upon request.
Gravimetric Extractables
Betane PP and PG series lter cartridges were tested for total gravimetric extractables by a four hour agitated soak test. The test results indicate that Betane PP and PG series lter cartridges have extractable levels of < 2 mg/ft2 of lter area in 21 °C water.
Polypropylene
Inner Core
& Outer Cage
Cartridge
Polypropylene
Support
Layers
Materials of Construction
Betane PP and PG series lter cartridges are produced from a pleated lter composite containing multiple layers of non-woven polypropylene, supported by upstream and downstream support material. Multiple cartridge lengths of various end modications are produced by thermal bonding which eliminates the need for adapters. No adhesives are used in the cartridge assembly process. All materials used comply with FDA CFR, Title 21 parts 170-199 for contact with food.
Chemical Compatibility
The compatibility data provided in Table 1 on page 3 is intended as a guide. It is recommended that compatibility with any process be established under actual ltration conditions, since operating parameters may inuence compatibility. Consideration must also be given in the selection of suitable gasket materials to conrm complete compatibility.
2
Table 1. Chemical Compatibility
Solution °C
Acetic Acid 25% 22 G G
Acetic Acid Glacial 22 G G
Acetone 22 G G
Acetonitrile 22 L L
Ammonia 10% 22 G G
Ammonium Hydroxide 10% 22 G G
Ammonium Hydroxide 28% 22 G G
Benzaldehyde 22 G G
Butylaldehyde 22 G G
Butyl Carbitol Acetate 22 G G
Butyl Cellosolve 22 G G
n-Butanol 22 G G
n-Butyl Acetate 22 G G
Butyl Carbitol 22 G G
Carbon Tetrachloride 22 L L
Cellusolve Acetate 22 G G
Cellusolve Solvent 22 G G
Chloroform 22 L L
Cotton Seed Oil 22 G G
Cyclohexanone 22 L L
Diethanolamine 22 G G
Di-Ethyl Formamide 22 G G
Di-Methyl Fomamide 22 G G
Di-Methyl Sulfoxide 22 G G
Ethanol Absolute 22 G G
Ethyl Acetate 22 L L
Ethyl Oleate 22 G G
Ether Diethyl 22 L L
Ethylene Glycol 22 G G
Ethylene Oxide 12-88% 22 L L
Betafine™
PP Series
Betafine™
PG Series
Betafine™ PP & PG Series
All Polypropylene Filter Cartridges
Solution °C
Formaldehyde 37% 22 G G
Formic Acid Concentrate 22 G G
Glycerol 22 G G
Hydrazine 22 G G
Hydrochloric Acid 37% 22 N G
Hydrofluoric Acid 22 N G
Hydrogen Peroxide Concentrate 22 G G
Isobutyl Alcohol 22 G G
Isopropyl Alcohol 22 G G
Methanol 22 G G
Methylene Chloride 22 L L
Methyl Cellosolve 22 G G
Methyl Isobutyl Ketone 22 L L
Monethanolamine 22 G G
Nitric Acid 22 G G
n-Propanol 22 G G
Phosphoric Acid, Glacial 22 G G
Propylene Glycol 22 G G
Pyridine Concentrate 22 L L
Sodium Hydroxide Concentrate 22 G G
Sodium Hypochlorite 22 G G
Sulfuric Acid Concentrate 22 G G
Tertiary Butyl Alcohol 22 G G
Toluene 22 N N
Trichloroethylene 22 L L
Trichlorotrifluoroethane (Freon) 22 G G
Triethylene Glycol 22 G G
Water 22 G G
Water 90 G G
Xylene 22 N N
G = Good compatibility to the temperature Indicated. L = Limited compatibility, testing recommended. N = No compatibility.
Betafine™
PP Series
Betafine™
PG Series
Operating Parameters & Specifications
Materials of Construction
Filter Media & Supports Polypropylene
Inner Core, Outer Cage, End Cap Adapters
Gasket & O-ring Options
Reinforcing Ring (BetafineTM PP Series only)
Dimensions 060 120 250 500 10C
Filtration Surface Area* 7.5 f t28.0 ft28.0 ft28.0 ft28.0 ft
Outer Diameter 2.8"
Length 10", 20", 30" & 40"
Polypropylene
Silicone, Fluorocarbon, EPR,
Nitrile
304 Stainless Steel
* Per 10” element.
Operating Conditions
Maximum Differential Pressure 60 psid
Maximum Operating Temperature 80 °C 60 °C
Heat Sterilization** 121 °C N/A
Recommended Rinse 15 minutes @ 3 gpm
Specified Parameters 060 120 250 500 10C
Nominal Rating 0.2 μm 0.65 μm 0.8 μm 2.2 μm 5.4 μm
Absolute Rating 0.6 μm 1.2 μm 2.5 μm 5.0 μm 10.0 μm
2
Efficiency @ Absolute > 99.99%
Extractables < 2 mg/ft2 of Filter Area
Rinse Up To 18 MΩ** < 15 minutes
Betafine™ PP Series Betafine™ PG Series
** Auto clave or in situ steam.
3
Betafine™ PP & PG Series Filter Cartridge Ordering Guide
Code
Nominal
Length Code
70002 01 10
Single Open End (SOE) 02 19
Code 7, 226 O-ring & Bayonet Lock 03 29
04 39
70003 01 10
SOE, Code 8, 222 O-ring & Bayonet Lock 02 19
03 29
04 39
70012 01 10
3
16
/
"
15
16
/
"
11
16
/
"
7
16
/
"
7
32
/
"
31
32
/
"
23
32
/
"
15
32
/
"
1
4
/
"
Gasket/O-ring Material Code
Grade Code/
& Rating
A — Silicone 060 (0.6 µm) P — Polypropylene P — Reinforced B — Fluorocarbon 120 (1.2 µm) G — General C — EPR 250 (2.5 µm)
D — Nitrile 500 (5.0 µm)
10C
(10.0 µm)
SOE, 222 O-ring 02 22"
03 31"
70025 01 10
SOE, Code 3, 222 O-ring 02 19
03 29 04 39
70048 01 9
SOE 222 O-ring 02 19
7
32
/
"
31
32
/
"
23
32
/
"
15
32
/
"
31
32
/
"
23
32
/
"
70002 70003 70025 7004870012 70005 70006
70005 01 10" A — Silicone 060 (0.6 µm) P — Polypropylene G — General
Double Open End (DOE), Flat Gasket 02 20" B — Fluorocarbon 120 (1.2 µm)
03 30" C — EPR 250 (2.5 µm) 04 40" D — Nitrile 500 (5.0 µm)
10C
(10.0 µm)
70006 01 9
DOE, Flat Gasket 02 19
03 29
3
4
/
"
1
2
/
"
1
4
/
"
04 39"
Media Code Control Grade Code
CAUTION: Care must be exercised in applying Betafine equivalent cartridges to competitive housings. While every effort has been made to ensure compatibility, exceptions may exist.
A dimensional check is recommended.
Important Notice
The information described in this literature is accurate to the best of our knowledge. A variety of factors, however, can affect the performance of the Product(s) in a particular application, some of which are uniquely within your knowledge and control. INFORMATION IS SUPPLIED UPON THE CONDITION THAT THE PERSONS RECEIVING THE
SAME WILL MAKE THEIR OWN DETERMINATION AS TO ITS SUITABILITY FOR THEIR USE. IN NO EVENT WILL 3M PURIFICATION INC. BE RESPONSIBLE FOR DAMAGES OF ANY NATURE WHATSOEVER RESULTING FROM THE USE OF OR RELIANCE UPON INFORMATION.
It is your responsibility to determine if additional testing or information is required and if this product is fi t for a particular purpose and suitable in your specifi c application.
3M PURIFICATION INC. MAKES NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER NATURE HEREUNDER WITH RESPECT TO INFORMATION OR THE PRODUCT TO WHICH INFORMATION REFERS.
Limitation of Liability
3M Purifi cation Inc. will not be liable for any loss or damage arising from the use of the Product(s), whether direct, indirect, special, incidental, or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.
Your Local Distributor:
3M Purifi cation Inc.
400 Research Parkway Meriden, CT 06450 U.S.A. Phone (800) 243-6894 (2 03 ) 23 7-5 541 Fax (203) 630-4530 www.3Mpurifi cation.com
Betafine is a trademark of 3M Company used under license.
Please recycle. Printed in U.S.A.
3M is a trademark of 3M Company.
© 3M 2011. All rights reserved.
70-0201-8787-1 REV 0911