ZXR103900A/3200ASeries
IntelligentRoutingSwitch
HardwareInstallationManual
Version2.8.23.A
ZTECORPORATION
ZTEPlaza,KejiRoadSouth,
Hi-TechIndustrialPark,
NanshanDistrict,Shenzhen,
P .R.China
518057
Tel:(86)75526771900
Fax:(86)75526770801
URL:http://ensupport.zte.com.cn
E-mail:support@zte.com.cn
LEGALINFORMATION
Copyright©2006ZTECORPORATION.
Thecontentsofthisdocumentareprotectedbycopyrightlawsandinternationaltreaties.Anyreproductionordistributionof
thisdocumentoranyportionofthisdocument,inanyformbyanymeans,withoutthepriorwrittenconsentofZTECORPORATIONisprohibited.Additionally,thecontentsofthisdocumentareprotectedbycontractualcondentialityobligations.
Allcompany ,brandandproductnamesaretradeorservicemarks,orregisteredtradeorservicemarks,ofZTECORPORA TION
oroftheirrespectiveowners.
Thisdocumentisprovided“asis”,andallexpress,implied,orstatutorywarranties,representationsorconditionsaredisclaimed,includingwithoutlimitationanyimpliedwarrantyofmerchantability,tnessforaparticularpurpose,titleornon-infringement.ZTECORPORATIONanditslicensorsshallnotbeliablefordamagesresultingfromtheuseoforrelianceonthe
informationcontainedherein.
ZTECORPORATIONoritslicensorsmayhavecurrentorpendingintellectualpropertyrightsorapplicationscoveringthesubject
matterofthisdocument.ExceptasexpresslyprovidedinanywrittenlicensebetweenZTECORPORATIONanditslicensee,
theuserofthisdocumentshallnotacquireanylicensetothesubjectmatterherein.
ZTECORPORATIONreservestherighttoupgradeormaketechnicalchangetothisproductwithoutfurthernotice.
UsersmayvisitZTEtechnicalsupportwebsitehttp://ensupport.zte.com.cntoinquirerelatedinformation.
TheultimaterighttointerpretthisproductresidesinZTECORPORATION.
RevisionHistory
RevisionNo.RevisionDateRevisionReason
R1.020100114
FirstRelease
SerialNumber:SJ-20100114103959-001
Contents
AboutThisManual..............................................i
SafetyIntroduction...........................................1
SafetyIntroduction.........................................................1
SafetyDescriptions.........................................................1
SystemOverview..............................................3
ProductOverview...........................................................3
Functions......................................................................4
TechnicalFeaturesandParameters...................................5
StructureandPrinciple......................................9
WorkingPrinciples..........................................................9
HardwareStructure.......................................................10
ZXR103228A............................................................10
ZXR103228A-EI.......................................................11
ZXR103228A-FI........................................................12
ZXR103252A............................................................12
ZXR103928A............................................................13
ZXR103928A-FI........................................................14
ZXR103952A............................................................14
ZXR103928A-PS.......................................................15
Units/ComponentsDescription.......................17
ControlandSwitchingBoard...........................................17
LineInterfaceCard........................................................20
FGEI........................................................................20
FGFI........................................................................21
FGFE........................................................................21
FBFE........................................................................22
PowerModule.................................................23
PowerModuleOverview..................................................23
ActivePowerSupply......................................................23
StandbyPowerSupply...................................................25
3228A-EIMonitoringInterface.........................................25
550wPowerSupplyUnitforZXR103928A-PS..................25
InstallationandDebugging.............................27
EquipmentInstallation...................................................27
DesktopInstallation...................................................27
CabinetInstallation....................................................28
CableInstallation..........................................................29
PowerCableInstallation.............................................29
ConsoleCableInstallation...........................................31
NetworkCableInstallation.........................................32
OpticalFiberInstallation.............................................33
Power-onProcedure.......................................................34
RPS180BackupPower....................................35
SystemOverview..........................................................35
ProductOverview.....................................................35
Functions................................................................35
TechnicalFeaturesandParameters..............................36
StructureandPrinciple...................................................36
WorkingPrinciples....................................................36
HardwareStructure...................................................37
Boards.........................................................................38
PowerConversionBoard.............................................38
CAPU.......................................................................38
CDPU.......................................................................38
LPDB.......................................................................39
InstallationandDebugging.............................................39
EquipmentInstallation...............................................39
DesktopInstallation..........................................39
CabinetInstallation..........................................39
CableInstallation.....................................................39
PowerCableInstallation....................................39
Power-onProcedure..........................................41
Figures............................................................43
Tables.............................................................45
PrerequisiteSkill
andKnowledge
WhatIsinThis
AboutThisManual
PurposeThismanualisZXR103900A/3200ASeries(V2.8.23.A)Intelli-
gentRoutingSwitchHardwareInstallationManual.Itprovides
proceduresandguidelinesthatsupporttheoperationonZXR10
3900A/3200ASeriesIntelligentRoutingSwitches,including:
�ZXR103928AIntelligentRoutingSwitch
�ZXR103928A-FIIntelligentRoutingSwitch
�ZXR103952AIntelligentRoutingSwitch
�ZXR103228AIntelligentRoutingSwitch
�ZXR103228A-FIIntelligentRoutingSwitch
�ZXR103228A-EIIntelligentRoutingSwitch
�ZXR103252AIntelligentRoutingSwitch
�ZXR103928A-PSIntelligentRoutingSwitch
Intended
Audience
Manual
ThismanualisintendedforengineersandtechnicianswhoperformoperationactivitiesonZXR103900A/3200AIntelligentRoutingSwitches.
Tousethehardwareinstallationmanualeffectively ,usersshould
haveageneralunderstandingofOSIModel.Familiaritywiththe
followingishelpful,
�Protocols
�RoutingconceptsandDataCommunicationT erminologies
Thehardwareinstallationmanualcontainsthefollowingchapters:
TABLE1CHAPTERSUMMARY
Chapter
Chapter1Safety
Instructions
Chapter2System
Overview
Chapter3Structureand
Principle
Chapter4Units/ComponentsDescription
Chapter5PowerModuleThischapterdescribesstructureand
CondentialandProprietaryInformationofZTECORPORATIONi
Summary
Thischapterdescribesthesafety
instructionsandsigns.
Thischapterdescribestheoverviewand
softwareandhardwarefeaturesofZXR10
3900A/3200Asystem.
ThischapterdescribesZXR103900A/3200A
structureandprinciples..
ThischapterdescribesZXR103900A/3200A
units/components.
parametersofZXR103900A/3200Apower
modules.
ZXR103900A/3200ASeriesHardwareInstallationManual
Chapter
Chapter6Installation
andDebugging
Chapter7RPS180
BackupPower
Documentation
Related
Thefollowingdocumentationisrelatedtothismanual:
�ZXR103900A/3200A(V2.8.23.A)SeriesIntelligentRouting
Summary
ThischapterdescribesZXR103900A/3200A
installationprocedureanddebugging
method.
ThischapterdescribesRPS180Backup
Power ,includingitsfunctions,technical
featuresandparameters,workingprinciple,
hardwarestructure,control&SwitchCard,
lineinterfacecard,powermoduleandfans.
SwitchHardwareManual
�ZXR103900A/3200A(V2.8.23.A)SeriesIntelligentRouting
SwitchUserManual(EthernetVolume)
�ZXR103900A/3200A(V2.8.23.A)SeriesIntelligentRouting
SwitchUserManual(BasicCongurationVolume)
�ZXR103900A/3200A(V2.8.23.A)SeriesIntelligentRouting
SwitchUserManual(IPv4Volume)
�ZXR103900A/3200A(V2.8.23.A)SeriesIntelligentRouting
SwitchUserManual(IPv6Volume)
iiCondentialandProprietaryInformationofZTECORPORATION
Chapter1
SafetyIntroduction
TableofContents
SafetyIntroduction.............................................................1
SafetyDescriptions.............................................................1
SafetyIntroduction
Inordertooperatetheequipmentinaproperway,followthese
instructions:
�Onlyqualiedprofessionalsareallowedtoperforminstallation,
operationandmaintenanceduetothehightemperatureand
highvoltageoftheequipment.
�Observethelocalsafetycodesandrelevantoperationpro-
ceduresduringequipmentinstallation,operationandmaintenancetopreventpersonalinjuryorequipmentdamage.Safety
precautionsintroducedinthismanualaresupplementarytothe
localsafetycodes.
�ZTEbearsnoresponsibilityincaseofuniversalsafetyoper-
ationrequirementsviolationandsafetystandardsviolationin
designing,manufacturingandequipmentusage.
SafetyDescriptions
ContentsdeservingspecialattentionduringZXR103900A/3200A
congurationareexplainedinT able2.
TABLE2SAFETYDESCRIPTION
Convention
Note
Important
Result
ExampleItprovidesinstanceillustration.
Meaning
Itprovidesadditionalinformation.
Itprovidesgreatsignicanceorconsequence.
Itprovidesconsequenceofactions.
CondentialandProprietaryInformationofZTECORPORATION1
ZXR103900A/3200ASeriesHardwareInstallationManual
Thispageisintentionallyblank.
2CondentialandProprietaryInformationofZTECORPORATION
Chapter2
SystemOverview
TableofContents
ProductOverview...............................................................3
Functions..........................................................................4
TechnicalFeaturesandParameters.......................................5
ProductOverview
ZXR103900A/3200AareindependentlydevelopedbyZTE.These
productsarewidelyusedinaccesslayerandconvergencelayerin
enterprisenetworkandtheysupportlayer–3application.Inconvergencelayer,theymeetthecustomer'sdemandsonupgradeby
gigstackingdevices.Inaccesslayer ,asingledevicecanmeetcustomer'sbasicrequirements.ZXR103900A/3200Acanalsobeused
incarriernetworkservingastandemswitchandaccessswitchor
otherdeviceintelecommunicationMAN.
ZXR103900A/3200Aprovides100MpbsEthernetinterfaceandgigabitEthernetinterfaces.AllportssupportL2/L3linespeedforwardingtomeetincreasingrequirementsonbandwidth.Additionally,ZXR103900A/3200Asupportsdiverseunicastandmulticast
protocols.
Withthenetworkdevelopment,moreandmoreservicesaresupportedondatanetworks.Thus,higherrequirementsonnetwork
devicequalityandsecurityshouldbemet.ZXR103900A/3200A
providesabundantpoliciesandresourcesfortheQualityofService
(QoS)andACLtoensuretheQoSandsystemsecurity .
ZXR103928A-PSEthernetswitchinZXR103900A/3200Asupports
PoE.Allofthe24100MpbsportsonthisswitchsupportPoEpower
supply,PoEinCISCOstandardandIEEE802.3afstandard.The
maximumone-portoutputis15.4w.Atthesametime,2415.4w
portscanbesupported.ThisPOEswitchcanbeusedtoconnect
deviceonEthernetreceivingend,includingCISCOIPtelephone,
accesspointandcamera.Alldown-streamEthernetreceivingend
switchcanbepoweredthroughPoEoutputport.ByusingPoE
switch,youdonotneedtoinstallwalloutletorpurchaseagreat
amountofcablesandcircuitsinIPtelephoneandWLANdeployment.Additionally,powerconnectororPoEcrossovercablesare
notrequiredforrunningIPdevices.
ZXR103900A/3200Ahasthefollowingfeatures:
�Carrier-classreliability
�Full-speedforwardingandlteringcapability
CondentialandProprietaryInformationofZTECORPORATION3
ZXR103900A/3200ASeriesHardwareInstallationManual
�Abundantnetworkprotocols
�Openarchitecturedesignwithgreaterupgradecapability
Functions
ZXR103900Acontainsthefollowingfourproducts:ZXR103928A,
ZXR103928A-FI,ZXR103952A,ZXR103928A-PS.Inthesame
way,ZXR103200Acontainsfourproductstoo:ZXR103228A,
ZXR103228A-FI,3228A-EI,ZXR103252A.AlltheaboveEthernetswitchseriesproductsusethesamesolution.
1.PhysicalPort
�Supportingportrate,duplexmodeandauto-sensing
�Supportingportmirroring
�Supportingbroadcaststormsuppression
�Supportinglinediagnosis&analysis
2.VLAN
�SupportingVLANbasedonport,protocol,andsubnet
�SupportingIEEE802.1Q,allowingupto4094VLANs
�SupportingPVLAN
�SupportingSVLAN
�SupportingSuperVLAN
3.Layer2Protocols
�SupportingSTP,RSTPandMSTP
�SupportingstaticTrunkandLACP
�SupportingIGMPSnooping
4.RoutingProtocols
�Supportingunicastroutingprotocolssuchasstaticroute,
RIPv1/v2,OSPF,IS-IS,BGP
�SupportingmulticastroutingprotocolssuchasIGMPv1/v2,
PIM-SM,MSDP
5.ACL
�SupportingbasicACL,extendedACL,L2ACLandhybrid
ACL
�SupportingACLtimerangelimit
6.QoS
�Supporting802.1p
�SupportingSPandWRRqueueschedulemode
�Supportingtrafcmonitoring
�Supportingow-basedegressredirection
�Supportingtrafcmirroringandtrafcstatistics
4CondentialandProprietaryInformationofZTECORPORATION
Chapter2SystemOverview
7.AccessAuthentication
�SupportingRADIUSClient
�SupportingDHCPRelayandDHCPServer
8.Reliability
�SupportingVRRP
�Supportingroutingloadbalance
9.NetworkManagement
�Supportingcommandlineinterface(CLI)conguration
mode
�Supportingcongurationthroughtheconsoleport,Telnet
andSSH
�SupportingSNMPandRMON
�SupportingNetNumenN31uniednetworkmanagement
system(NMS)
10.ZXR103228A–EI
�Supportingthreechannelbackbonenodesignalinput
�Supportingvechannelbackbonenodesignaloutput
11.ZXR103928A–PS
�Supporting24PoEportswith15.4w-output,providing
seamlessconnectiontoPoE,CISCOIPtelephone,Cisco
Aironet®accesspointandcameraandanyterminaldevice
meetingIEEE802.3afstandard.
�Powerfulandexiblemanagement,powersupplysetting
withmoredetailsthanIEEEstandard
TechnicalFeaturesand
Parameters
ZXR103900A/3200Atechnicalfeaturesandparametersarelisted
inT able3.
TABLE3ZXR103900A/3200ATECHNICALFEATURESAND
PARAMETERS
Item
Dimensions
Description
ZXR103228A:43.6mm(height)×442mm
(width)×280mm(depth)
ZXR103228A-FI:43.6mm(height)×442mm
(width)×280mm(depth)
ZXR103228A-EI:43.6mm(height)×442mm
(width)280mm(depth)
ZXR103252A:43.6mm(height)×442mm
(width)×360mm(depth)
CondentialandProprietaryInformationofZTECORPORATION5
ZXR103900A/3200ASeriesHardwareInstallationManual
Item
Description
ZXR103928A:43.6mm(height)×442mm
(width)×280mm(depth)
ZXR103928A-PS:43.6mm(height)×442mm
(width)×400mm(depth)
ZXR103928A-FI:43.6mm(height)×442mm
(width)×280mm(depth)
ZXR103952A:43.6mm(height)×442mm
(width)×360mm(depth)
WeightZXR103228A:3.5kg
ZXR103228A-FI:4kg
ZXR103228A-EI:3.5kg
ZXR103252A:4.5kg
ZXR103928A:3.5kg
ZXR103928A-PS:5.9kg
ZXR103928A-FI:4kg
ZXR103952A:4.5kg
PowersupplyACpowersupply:100V~240V ,50Hz~60Hz
DCpowersupply:-57V~-40V
Power
consumption
ZXR103228A:20w
ZXR103228A-FI:60w
ZXR103228A-EI:20W
ZXR103252A:35w
ZXR103928A:20w
ZXR103928A-PS:435w(maincontrolbord:65w,
MOPofPoE:370w)
ZXR103928A-FI:60w
ZXR103952A:35w
ReliabilityMTBF:>200000hours
MTTR:<30minutes
Lightning
4KV
protection
Environment
temperature
Environment
Operatingambienttemperature:-50Cto45
Storagetemperature:-40
Relativehumidity:10%to90%,non-condensing
humidity
Memorysize
ZXR103228A:256M
ZXR103228A-FI:256M
ZXR103228A-EI:256M
ZXR103252A:256M
ZXR103928A:256M
ZXR103928A-PS:256M
ZXR103928A-FI:256M
ZXR103952A:256M
6CondentialandProprietaryInformationofZTECORPORATION
0
C.
0
Cto70
0
C
Chapter2SystemOverview
Item
Switching
capacity
Packet
forwardingrate
Routingtable
entry
MACaddress
tabledepth
Description
ZXR103228A:18.8G
ZXR103228A-FI:18.8G
ZXR103228A-EI:18.8G
ZXR103252A:29.6G
ZXR103928A:18.8G
ZXR103928A-PS:18.8G
ZXR103928A-FI:18.8G
ZXR103952A:29.6G
ZXR103228A:13.98M
ZXR103228A-FI:13.98M
ZXR103228A-EI:13.98M
ZXR103252A:22.02M
ZXR103928A:13.98M
ZXR103928A-PS:13.98M
ZXR103928A-FI:13.98M
ZXR103952A:22.02M
ZXR103900A/3200A:12K
ZXR103900A/3200A:16K
CondentialandProprietaryInformationofZTECORPORATION7
ZXR103900A/3200ASeriesHardwareInstallationManual
Thispageisintentionallyblank.
8CondentialandProprietaryInformationofZTECORPORATION
Chapter3
StructureandPrinciple
TableofContents
WorkingPrinciples..............................................................9
HardwareStructure...........................................................10
WorkingPrinciples
ZXR103900A/3200Aseriesproductsarethebox(L3)line-rateEthernetswitchesdevelopedbyZTE.Thisseriesswitchesadoptmodulardesignandhavestrongcapabilityinservicecontrolanduser
managementsoastoprovidenetworkingsolutionstoconvergence
ofenterprisenetwork,IPMANnetworkandresidentialblock.
Thisseriesproductshavepowerfulfunctionsandsoundperformance.Accordingtosystemfunctions,theproductscontainthe
followingmodules:controlmodule,switchingmodule,interface
moduleandpowermodule.
1.Controlmodule:Itcontainsmainprocessorandsomeother
externalfunctionalchipsandisusedforsystemtoprocessvariousapplications.Itprovidesconsoleportfordatamanipulationandmaintenance.
2.Switchingmodule:themainpartofswitchingmoduleispacket
processor ,usedforprocessingandswitchingofpacketssent
fromports.
3.Interfacemodule:Itiscomposedofinterfacechipsandperipheralscircuitstoconnecttheexternaluserandreceive/send
packets.
4.Powermodule:Themoduleadopts220VACor-48VDCtosupplyneededpowertotheothercomponentswithinthesystem.
5.Monitormodule(providedonlybyZXR103228A-EI):signal
inputonthreepairsofbackbonenodes,signaloutputonve
pairsofbackbonenodes.
ZXR103900A/3200AsystemprinciplediagramisshowninFigure
1.
CondentialandProprietaryInformationofZTECORPORATION9
ZXR103900A/3200ASeriesHardwareInstallationManual
FIGURE1ZXR103900A/3200ASYSTEMPRINCIPLE
ZXR103900A/3200Asystemadoptsstandard19-inchplug-inbox,
whichcanbeinstalledoutsideseparatelyorwithinthestandard
cabinet.
HardwareStructure
ZXR103228A
ThechassisheightofZXR103228Ais1U(1U=44.45mm).ZXR10
3228Acansupport24100MpbsEthernetelectricalinterfacesand
2xedgigabitEthernetopticalinterfaces.Theelectricalinterface
isRJ45,supportingtwistedpairsofCAT5andabove.Theoptical
interfaceisSFP ,supportingvariousgigabitopticalmodulesmeetingSFPstandard.Thereisoneslotonthefrontpanel,supporting
fourdifferentinterfacecards.
ThefrontpanelofZXR103228AisshowninFigure2.
FIGURE2ZXR103228AFRONTPANEL
ThebackplaneofACpowersupplyinZXR103228Aisshownin
Figure3
FIGURE3ZXR103228ABACKPLANE(AC)
.
10CondentialandProprietaryInformationofZTECORPORATION