4.5CabinetInstallation
4.5.1InstallationModeInstruction
Accordingtodifferentinstallationenvironments,therearethreemodesofR8860EGU198 installation:
lPole-mountinstallation lWall-mountinstallation lGantry-mountinstallation lSimplied-cabinetintegrativeInstallation
4.5.2InstallationMethodsandAccessories
TherearetwoinstallationmethodsforR8860EGU198,asbelow:
lPolemountedinstallation(PoleMountingKit):Itissuggestedthatthediameterof
installationpoleshouldbe60mm~120mm.
lPolemountedinstallation(UniversalSheet-MetalKit):Itissuggestedthatthe
diameterofinstallationpoleshouldbe60mm~114mm.
lWallmountedinstallation.
Chapter4Installation
Note:
Theuniversalsheet-metalkitalsosupportchannelironandangleiron.Thesupported channelwidthis50mm–100mm.Thesupportedangleironwidthis63mm-80mm.(The installationmethodissimilartothepoleinstallation.)
4.5.2.1InstallationAccessories
TheinstallationaccessoriesofR8860EGU198andtheirfunctionsareshowninT able4-3.
4-21
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 2
ZXSDRR8860EGU198UserManual
Table4-3INSTALLATIONACCESSORIESOFR8860EGU198ANDTHEIRFUNCTIONS
NameShapeFunction
Wallmounted
installation
assembly
Clampassembly
forpolemounted
installation
Usedbywall
mountedandpole
mountedinstallation
(clampassembly
forpolemounted
installation)
Forthepolewith
1or2R8860E
GU198polemounted
installation
Mountingbracket
assemblyfor
polemounted
installation
4-22
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Forthepolewith3
R8860EGU198pole
mountedinstallation
Page 3
Chapter4Installation
NameShapeFunction
MountingBaseUsedbypole
mountedinstallation
ofR8860EGU198
MountingPieceUsedbyxingonthe
pole
Lightningpretector
piece
ExpansionpieceForthepolewith
Usedbypole
mountedinstallation
ofLightningpretector
box
thethirdR8860E
GU198polemounted
installation
4-23
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 4
ZXSDRR8860EGU198UserManual
NameShapeFunction
ProtectionshadeToshieldR8860E
4.5.2.2WallMountedInstallation
Fixtheassemblyforwallmountedinstallationonthewall,andthenxR8860EGU198on theassemblywithbolts,asshowninFigure4-7.
Figure4-7WALLMOUNTEDINSTALLA TIONFORR8860EGU198
GU198fromdirect
sunlight
4-24
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 5
4.5.2.3PoleMountedInstallation(PoleMountingKit)
Ifthereareonly1or2R8860EGU198s,usetheclampassemblytoxit/themonthepole, asshowninFigure4-8.
Figure4-8POLEMOUNTEDINSTALLA TIONFOR1OR2R8860EGU198s
Ifthereare3R8860EGU198s,usethemountingbracketassemblytoxthemonthepole, asshowninFigure4-9.
Chapter4Installation
Figure4-9POLEMOUNTEDINST ALLATIONFOR3R8860EGU198s
4.5.2.4PoleMounting(UniversalSheet-MetalKit)
InthesingleR8860EGU198solutiontheunitisxedonthepolebyanuniversalmounting kit,asshowninFigure4-10.
4-25
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 6
ZXSDRR8860EGU198UserManual
Figure4-10TheSingleR8860EGU198MountingSolution
InthedoubleR8860EGU198solutiontheunitisxedonthepolebyanuniversalmounting kit,asshowninFigure4-1 1.
Figure4-11TheDoubleR8860EGU198MountingSolution
InthetripleR8860EGU198solutiontheunitisxedonthepolebyanuniversalmounting kit,asshowninFigure4-12.
4-26
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 7
Figure4-12TheTripleR8860EGU198MountingSolution
Chapter4Installation
4.5.3R8860EGU198Installation
TheinstallationofR8860EGU198includestwoparts,thatis,mainpartinstallationand cableinstallation.TheinstallationowisshowninFigure4-13.
4-27
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 8
ZXSDRR8860EGU198UserManual
Figure4-13R8860EGU198INSTALLATIONFLOW
4.5.3.1WallMountedInstallationforR8860EGU198
Steps
1.DrillholesonthewallwithholingtemplateaccordingtotheR8860EGU198installation positionspeciedintheengineeringdesigndocuments,andinstalltheexpansion bolts.Thedepthoftheholeshouldbeabout60mm.Theholingtemplateisshownin
Figure4-14.
4-28
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 9
Figure4-14HOLINGTEMPLATE
Chapter4Installation
2.Assemblethewallmountedinstallationassembly,asshowninFigure4-15.Fixthe assemblyonthewallwithbolts.
4-29
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 10
ZXSDRR8860EGU198UserManual
Figure4-15ASSEMBLINGWALL-MOUNTEDINSTALLATIONASSEMBL Y
1.Expansionbolt
2.Insulationplate
3.Wall-mountingplate
4.Insulationflange
5.Flatwasher
6.Springwasher
7.Nut
3.HangtheR8860EGU198cabinetonthewallmountedinstallationassembly(alignit withtheclamps),andxthecabinettotheassemblywith2M6bolts,asshownin
Figure4-16.
4-30
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 11
Figure4-16FIXINGTHECABINET
Chapter4Installation
1.Wall-mountinginstallat ioncomponentsclamp
2.Screw
3.Fixationboard
–EndofSteps–
4.5.3.2PoleMountedInstallationforR8860PoleMountingKit
4.5.3.2.1Installing1R8860EGU198
Steps
1.Install2setsofclampassembliesonthepole,andfastenthemjustalittle.Adjustthe distancebetweenthepoleclampassembliesaccordingtothescrewholesandthen fastenM8bolts.Finally,fastenthescrewsonthepoleclampassemblies,asshown inFigure4-17.
4-31
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 12
ZXSDRR8860EGU198UserManual
Figure4-17INSTALLINGCLAMPASSEMBL Y
1.M8nut
2.Springwasher
3.Flatwasher
4.Insulationflange
5.Wall-mounting installationassemblies
6.Insulationboard
7.Hoop
8.Bolt
9.Pole
10.Plainwasher
11.Springwasher
12.NutHoop
13.Hoop
2.HangtheR8860EGU198cabinetonthewallmountedinstallationassembly(alignit withtheclamps),andxthecabinettotheassemblywith2M6bolts,asshownin
Figure4-18.
4-32
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 13
Figure4-18FIXINGTHECABINET
Chapter4Installation
1.Screw2.Clipboard3.Fixationboard
–EndofSteps–
4.5.3.2.2Installing2R8860EGU198s
Steps
1.Install4setsofclampassembliesonthepole,andfastenthemjustalittle,asshown inFigure4-19.
4-33
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 14
ZXSDRR8860EGU198UserManual
Figure4-19INSTALLINGCLAMPASSEMBL Y
1.Nut
2.Springwasher
3.Plainwasher
4.Hoop
5.Bolt
Note:
Wheninstalling2R8860EGU198s,decidethelengthofclampassemblybolts accordingtotheresultofengineeringsurvey.Ifthepolediameterisintherange60 mm~90mm,useboltswiththelength80mm.Ifthepolediameterisintherange90 mm~120mm,useboltswiththelength130mm.
2.Assemble2setsofwallmountedinstallationassembliesandfastentheM8bolts,as showninFigure4-20.Fastentheboltsoftheclampassemblies.
4-34
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 15
Chapter4Installation
Figure4-20ASSEMBLINGWALL-MOUNTEDINSTALLATIONASSEMBL Y
1.Bolt
2.Springwasher
3.Plainwashe
4.Insulationflange
5.Wall-mounting installationassemblies
6.Insulationwasher
7.Hoop
3.HangtheR8860EGU198cabinetonthewallmountedinstallationassembly(alignit withtheclamps),andxthecabinettotheassemblywith2M6bolts,asshownin
Figure4-21.
Figure4-21FIXINGTHECABINET
1.Screw2.Wall-mounting
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
installationassemblies
4-35
Page 16
ZXSDRR8860EGU198UserManual
3.Fixationboard
–EndofSteps–
4.5.3.2.3Installing3R8860EGU198s
Steps
1.Install4setsofmountingbracketassembliesonthepole,backtoback,andfasten themjustalittle,asshowninFigure4-22.
Figure4-22INSTALLINGMOUNTINGBRACKETASSEMBL Y
1.Fixationplate
2.Nut
3.Springwasher
4.Plainwasher
2.Assemble3setsofwallmountedinstallationassembliesandfastentheM8bolts,as showninFigure4-23.Fastentheboltsoftheclampassemblies.
4-36
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
5.Bolt
Page 17
Chapter4Installation
Figure4-23ASSEMBLINGWALL-MOUNTEDINSTALLATIONASSEMBL Y
1.Fixationplate
2.Largeinsulationplate
3.Wall-mounting installationassemblies
4.Insulationflange
5.Plainwasher
6.Springwasher
7.Bolt
3.HangtheR8860EGU198cabinetonthewallmountedinstallationassembly(alignit withtheclamps),andxthecabinettotheassemblywith2M6bolts,asshownin
Figure4-24.
Figure4-24FIXINGTHECABINET
1.Screw2.Wall-mounting
installationassemblies
4-37
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
3.Fixationboard
Page 18
ZXSDRR8860EGU198UserManual
Note:
Theemptysideofmountingbracketcanbebesidethewallorusedtoinstalloutdoor lightningprotectionbox.
–EndofSteps–
4.5.3.3PoleMounting(UniversalSheet-MetalKit)
4.5.3.3.1PoleMounting(SingleUnitSolution)
Steps
1.Fixtwosetsoffrontmountingpieces(keepthescreenprintingonthetop)onto themountingbasebyfourM8×35bolts,andinsertfourM10×180longboltstothe mountingbaseandattachthemountingbasetothepole,thenattachtwomounting pieces(keepthescreenprintingonthetop)totheoppositepositionofthepoleand connectthemtothelongboltasshowninFigure4-25.
Figure4-25FixingtheMountingPiece
1.MountingPiece(the
screenprintingonthe top)
2.Pole
3.MountingBase
4.InsulatingFlange
5.M8×35Bolt
6.FlatWasher
7.LockWasher
8.M10×180LongBolt
2.AttachtheR8860EGU198ontothehooksonthemountingbaseandfastenitwith fourM6×20allenscrews,asshowninFigure4-26.
4-38
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 19
Figure4-26MountingR8860EGU198
–EndofSteps–
4.5.3.3.2PoleMounting(DoubleUnitSolution)
Chapter4Installation
Steps
1.Fixtwosetsoffrontmountingpieces(keepthescreenprintingonthetop)ontothe mountingbasebyfourM8×35bolts.AndInsertfourM10×180longboltstothe mountingbase.
2.Fixtwosetsofrearmountingpieces(keepthescreenprintingonthetop)ontoanother mountingbasebyfourM8×35bolts.
3.Attachthefront/rearmountingpiecestothepole(keepthescreenprintingonthetop). FastentheM10×180longbolts(notetheboltsgothroughtheinsulatingange),as showninFigure4-27andFigure4-28.
4-39
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 20
ZXSDRR8860EGU198UserManual
Figure4-27MountingbaseDoubleUnitSolution
Figure4-28MountingbaseSingleUnit+LightningProtectorBoxSolution
4-40
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 21
Chapter4Installation
Note:
Thefastenersareshowninthelastsectionsingleunitsolution.
ThedoubleunitmountingbasesolutionsupportstwoR8860EGU198oroneR8860E GU198andalightarrestorunit.
4.FastentheM10×180boltsandattachR8860EGU198tothemountingbase.Fasten theconnectionwiththeM6×20Allenbolts,asshowninFigure4-29andFigure4-30.
Figure4-29MountingTwoR8860EGU198
4-41
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 22
ZXSDRR8860EGU198UserManual
Figure4-30MountingoneR8860EGU198andOneLightningProtectorBox
Note:
Thelightningprotectorboxisxedontothelightningprotectorboxmountingbasewith theboltsfastened,asshowninFigure4-31.
Figure4-31FixingtheLightningProtectorBox
–EndofSteps–
4-42
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 23
4.5.3.3.3PoleMounting(TripleUnitSolution)
Steps
1.Securetwosetsofmountingpiecesandmountingbasesonthepoleandattachtwo R8860EGU198,asshowninFigure4-32.
Figure4-32MountingTwoR8860EGU198
Chapter4Installation
2.AttachtheexpansionpiecetoasideofthepoleandfastenwithM6×60bolts.Install thelowerpiecebeforethehigherpiece,asshowninFigure4-33.
Figure4-33MountingtheExpansionPiece
4-43
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 24
ZXSDRR8860EGU198UserManual
3.AttachthemountingbaseontotheexpansionpieceandfastenwiththeM10×35bolts, asshowninFigure4-34.
Figure4-34AttachingtheMountingbase
4.AttachtheR8860EGU198ontothehooksonthemountingbaseandfastenitwith fourM6×20Allenscrews,asshowninFigure4-35.
4-44
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 25
Figure4-35AttachtheR8860EGU198totheMountingbase
Chapter4Installation
–EndofSteps–
4.5.3.4InstallingProtectionShade
Steps
1.HangtheR8860EGU198cabinetonthewall.
2.Fixtheprotectionshadeonthe4xingpositionsonthefrontofR8860EGU198 cabinet,andfastenitonthehandlesontopofthecabinetwith2M6bolts,asshown inFigure4-36.
4-45
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 26
ZXSDRR8860EGU198UserManual
Figure4-36INSTALLINGPROTECTIONSHADE
1.M6screw
2.Protectionshade
3.Handle
4.Buckle
–EndofSteps–
4.6ExternalCableInstallation
4.6.1ExternalCableLayout
TheconnectionrelationshipofR8860EGU198externalcablesisdescribedinT able4-4.
Table4-4R8860EGU198ExternalCableConnectionRelationship
NameConnectionRelationshipDescription
PowercableConnectstheR8860EGU198
powerinterface(DCIN)to
thepowersupplyequipment
interface
4-46
5.R8860EGU198
Oneendistheaviationplugand
theotherendisreservedfor
powercablemadeonsite.The
lengthofcableisbasedonthe
engineeringsurvey.
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 27
NameConnectionRelationshipDescription
Chapter4Installation
GroundingcableConnectsoneR8860EGU198
groundbolttothecopperbar
OpticalFiberTherearetwotypesofR8860E
GU198ber:BBUconnection/
R8860EGU198cascading.
EnvironmentmonitoringcableConnectstheR8860EGU198
environmentmonitoring
interfaceMONtotheexternal
monitoringcomponentsorthe
drycontact.
Thegroundingcableismade
upofstrandsofame-retardant
wire.Thecrosssectionalarea
ofR8860EGU198grounding
cableis10mm
2
.Thecolorof
groundingcableisyellowand
green.Copperlugsarecrimped
atbothendsoftheR8860E
GU198groundingcable.
TherearetwotypesofR8860E
GU198opticalber:oneused
inBBUconnectionandtheother
usedincascadingbetween
R8860EGU198s.
Aendoftheenvironment
monitoringcableisPINdesign.
Bend,with3mlengthintotal,
needsmakingbasedonthe
on-siteengineering.
AISGcontrolcableConnectstheR8860EGU198
debugginginterface(AISG)
tothecontrolinterfaceof
electrical-adjustmentantenna.
Frequencypointextension
cable
InterconnectstheR8860E
GU198RXin/RXoutinterfaces.
Antenna,feederandjumperConnectstheR8860EGU198
tothemainfeeder .
AISGisusedforcontrolofthe
electrical-adjustmentantenna.
Thefrequencypointextension
cableusuallyadoptsthenished
1/2″jumperwith2mlength.
Thejumpercanbeself-made
basedonthereal-timecondition
onsite.
AandBendsofjumperareN
connectors(male).
TheRFjumperusuallyadopts
thenished1/2″jumperwith
2mlength.Thejumpercan
beself-madebasedonthe
real-timeconditiononsite.
TheendofjumperisN
connector(male)andtheother
endisDINconnector(female).
4-47
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 28
ZXSDRR8860EGU198UserManual
4.6.2ExternalCableInstallationFlow
Figure4-37liststheinstallationowofexternalcable.Thisowcanbeadjustedbasedon
thereal-timecondition.
Figure4-37ExternalCableInstallationFlow
4-48
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 29
4.6.3InstallingPowerCable
Context
TheR8860EGU198cabinetadopts-48VDCforpowersupply.EndAistheaviationplug andEndBisreservedforself-madepowercableonsite.Thelengthofpowercableis accordingtotheengineeringsurvey.
R8860EGU198Figure4-38showsthestructureofpowercable.
Figure4-38PowerCablestructure
Table4-5describesthecolorsandspecicationsofinsidecorecable.
Table4-5ColorandSpecication
ColorSpecication
Chapter4Installation
Blue-48V
Black-48VGND
Note:
1.Ifthetwo-corecableisadopted,thebluecorecablestandsfor-48Vandtheblack corecablestandsfor-48VGND;
2.Ifthefour-corecableisadopted,thetwobluecorecablesconnectedinparallelstand for-48Vandtheblackcorecablesconnectedinparallelstandfor-48VGND.
Steps
1.ConnectEndAofpowercablewithDCINinterfacelocatedatthebottomofR8860E GU198.
2.StriptheprotectivecoatofEndBandconnectitwiththeDCinputpowersource accordingtocolorsoftheinsidecorecable.
3.MakewaterproofprotectionofEndB.
4.Attachlabelsatbothendsofthepowercable.
5.Fixthepowercable.
–EndofSteps–
4-49
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 30
ZXSDRR8860EGU198UserManual
4.6.4InstallingGroundingCable
Context
Thegroundingcableismadeupofstrandsofame-retardantwire.Thecrosssectional areaofR8860EGU198groundingcableis10mm yellowandgreen.CopperlugsarecrimpedatbothendsoftheR8860EGU198grounding cable,asshowninFigure4-39.
Figure4-39GroundingCableStructure
Steps
2
.Thecolorofgroundingcableis
1.CoverandxacopperlugontheagroundingboltoftheR8860EGU198cabinet.
2.Connecttheothercopperlugtotheearth-networkingcopperbarandxitwithabolt, asshowninFigure4-40.
Figure4-40Earth-networkCopperBar(Unit:mm)
3.Attachthelabelonthegroundingcable.
4.Measurethegroundingresistanceandmakesureitlessthan5Ω.
–EndofSteps–
4-50
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 31
4.6.5InstallingFiberbetweenBBUandRRU
Prerequisites
TheR8860EGU198cabinetmustbeinstalledandxedsuccessfully.
Context
Figure4-41showsberconnectionbetweenR8860EGU198andBBU.
Figure4-41FiberConnectionbetweenR8860EGU198andBBU
1.OutdoorSealComponent
WhileconnectingaBBUtoR8860EGU198,makesurethatthebasebandRFber interface(LC1/2)oftheR8860EGU198isconnectedtotheopticalinterfaceconnector oftheBBU.
Chapter4Installation
Steps
1.Attachlabelsatbothendsoftheber.
2.AdjustthesideofEndAwiththecolormarkandinserttheR8860EGU198ber interface,andscrewdownthenuts,asshowninFigure4-42
4-51
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 32
ZXSDRR8860EGU198UserManual
Figure4-42OpticalFiberInstallation
1.Colormark
3.ConnectEndAofthebertothebasebandRFberinterface(LC1/2)oftheR8860E GU198.
4.ConnectEndBoftheber,whichisaDLCconnector,totheBBUopticalconnector.
5.ScrewdowntheoutdoorsealcomponentatEndAforwaterproong.
–EndofSteps–
4.6.6InstallingFiberbetweenRRUandRRU
Prerequisites
ThecascadingR8860EGU198cabinetsmustbeinstalledandxedsuccessfully.
Context
Figure4-43showsberconnectionbetweenR8860EGU198s.
Figure4-43FiberConnectionbetweenR8860EGU198s
1.OutdoorSealComponent
4-52
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 33
Chapter4Installation
WhileinterconnectingtheR8860EGU198s,makesurethatthetwobasebandRFber interfaces(LC1/2)oftheR8860EGU198areconnected.
Steps
1.Attachlabelsatbothendsoftheopticalber.
2.AdjustthesideofEndAwiththecolormarkandinserttheR8860EGU198ber interface,andscrewdownthenuts,asshowninFigure4-44.
Figure4-44OpticalFiberInstallation
1.Colormark
3.ConnectEndAoftheopticalbertothebasebandRFberinterface(LC1/2)ofthe R8860EGU198.
4.ConnectEndBoftheopticalbertotheotherbasebandRFberinterface(LC1/2)of theR8860EGU198.
5.ScrewdowntheoutdoorsealcomponentatEndAforwaterproong.
–EndofSteps–
4.6.7InstallingEnvironmentMonitoringCable
Prerequisites
TheR8860EGU198cabinetmustbeinstalledandxedsuccessfully.
4-53
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 34
ZXSDRR8860EGU198UserManual
Context
Theenvironmentmonitoringcableprovidesa485interface,usedforR8860EGU198 environmentmonitoring.Inaddition,thecablealsoprovidesfourextensionaccessesfor externaldrycontactmonitoring.
EndAisthe37PINconnector,andEndBismadebyon-siteengineering.Thetotallength is3m.Figure4-45showstheappearanceofenvironmentmonitoringcable.
Figure4-45EnvironmentMonitoringCable
Theconnector,connectingtheenvironmentmonitoringcabletotheR8860EGU198, adopts37–coreaviationjack.TheconnectoraccordswiththeGJB599specication.The connectorappearanceisasshowninFigure4-46
Figure4-46AviationJackAppearance
Table4-6describestheconnectorpins.
Table4-6CablePinDescription
PinCore-CableColorSignalDescription
15/16Whiteandblue/blueDrycontact4-/+
17/18Whiteandorange/orangeDrycontact3-/+
19/20Whiteandgreen/greenDrycontact2-/+
21/22Whiteandbrown/brownDrycontact1-/+
23/24Redandblue/blueRS485receive
25/26Redandorange/orangeRS485transmit
Steps
1.ConnectEndAtotheMONinterfacelocatedatthebottomofR8860EGU198.
4-54
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 35
2.ConnectEndBwithexternalmonitoringdevicesordrycontacts.
3.AttachthelabelatEndB.
–EndofSteps–
4.6.8InstallingAISGControlCable
Context
TheAISGcontrolcableisusedforcontroloftheelectricaladjustmentantenna.
Figure4-47showsthestructureoftheAISGcontrolcable.
Figure4-47AISGControlCableStructure
Chapter4Installation
Table4-7describestheserialNo.meaningofAISGcontrolcable.
Table4-7AISGControlCableDescription
SerialNo.NameMeaning
1TRX_ANT_485_+RS485+
2TRX_ANT_485_-RS485-
3,4TRX_ANT_28V28V
5,6TRX_ANT_28VGND28VGND
7,8NCNull
Steps
1.ConnectEndAtotheR8860EGU198debugginginterface(AISG)andscrewdown thebolt;
2.ConnectEndBtothecontrolinterfaceofelectricaladjustmentantennaandscrew downthebolt.
–EndofSteps–
4-55
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 36
ZXSDRR8860EGU198UserManual
4.6.9InstallingFrequencyPointExtensionCable
Prerequisites
ThetwoR8860EGU198cabinetstobecombinedmustbeinstalledandxedsuccessfully.
Context
Afterthecombinationofcabinets,theR8860EGU198cansupport8carriersectorsat most.
ThetwoR8860EGU198cabinetsareconnectedthroughtheirconnectinginterfacessuch asRXinandRXoutbytwofrequencypointextensioncables.Figure4-48showsthe structureofthefrequencypointcable.EndAandEndBareNconnectors(male).
The2M1/2″jumperisoftenusedforthefrequencypointextensioncable.Itmaybe preparedonsiteifnecessary.
Figure4-48FrequencyPointExtensionCable
Steps
1.ConnectEndAofthefrequencypointextensioncabletothefrequencypointextension interfaceRXINofoneR8860EGU198;
2.ConnectEndBtoRXoutoftheotherR8860EGU198;
3.ConnecttheremainingRXin/RXoutinterfacesofthetwocombinedcabinetswiththe otherfrequencypointextensioncable.
–EndofSteps–
4.6.10InstallingJumper
Context
OneendofRFjumperconnectswiththemainfeederandtheotherendconnectswiththe antennafeederinterfaceofR8860EGU198cabinet.BeforeinstallingtheRFjumper,the mainfeederisinstalled.
TheRFjumperadoptsthe1/2″jumperwitha2mlength.Thejumpercanalsobeself-made accordingtotheon-sitecondition.
TheinstallationpositionofRFjumperisasshowninFigure4-49.
4-56
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 37
Figure4-49RFJumperInstallation
PerformthefollowingstepstoinstalltheRFjumper.
Steps
Chapter4Installation
1.ConnecttheDINconnector(male)ofRFjumperwiththeDINconnector(female)of mainfeeder.
2.ConnecttheDINconnector(male)ofRFjumperwiththeDINconnector(female)of R8860EGU198cabinet.
3.SealtheconnectorswithwaterproofadhesivetapesandPVCtapes.
–EndofSteps–
4.7HardwareInstallationInspection
4.7.1CheckingCabinetInstallation
Steps
1.Ensurethatthecabinetinstallationpositioncomplieswiththeengineeringdesign drawing.
2.Erectcabinetrmlysoastoresistanearthquakemeasuringupto7.0onRichterscale.
3.Ensurethathorizontalandverticalerrorislessthan3mm.
4.Ensurethatcabinetsurfaceiscleanandtidyandcoveredwellbyoilpaint.Allparts ofthecabinetarecompleteandallmarkingonthecabinetarecorrect,clearand complete.
5.Ensureallscrewsarexedtightwithatwashersorspringwashers.
–EndofSteps–
4-57
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 38
ZXSDRR8860EGU198UserManual
4.7.2CheckingCableInstallation
4.7.2.1CablesInstallationGeneralSpecification
OpticalFiber
Note:
Thelengthofopticalberisdecidedbyengineeringsurvey(1Tx,1Rx).
Thetechnicalspecicationsofopticalberareasfollows:
lTheopticalberisasinglemodewithEndBadoptingtwoDLC/PCconnectors. lTheinsertionlossislessthat0.3dB. lThereturnlossislessthan45dB. lIfopticalberistobeusedoutdoor,then
1.T akewaterproofandanti-ultravioletprotectionmeasures.
2.Makesurethatworkingtemperatureisinbetween-40to80
lThesheathofopticalberisblackincolorwithadiameterof7mm.Underthesheath,
therearetwocoresopticalwires(yellowandbluecolor)withsubstantialamountof protectionpadding.
lThemaximumdistancebetweencoreopticalwires(includingbothDLC/PC
connectors)andsheathedopticalberis350mm.
lZTEsupplies15m,25m,35m.50m,70m,100m,and130mlongbercables. lThe20mmlongblackPyrocondensationcannulashouldbeaddedinbetweenoptical
corewiresandsheathedopticalber.
lThelabelattachedatbothendsshouldsatisfytherequirementsofZTECable
DesigningCriteria–LabelDesigningandUsageRequirements.
o
C.
AISGCable
ThefollowingarethetechnicalspecicationofAISGcable:
lTable4-8illustratestheconnectionrelationshipofbothends.Makesuretoenclose
EndAconnectionbyblackcannulacompletelyafterconnecting.
Table4-8ConnectionRelationship
Serial
Number
1485+Pin3Pin1-
2485-Pin5Pin2-
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Signal
Denition
EndAPin
4-58
EndBPin
Number
Number
ConnectedCable
Page 39
Chapter4Installation
Serial
Number
328VPin6Pin3,4TwocablesfromPin6
428VGNDPin7Pin5,6TwocablesfromPin7
Signal
Denition
EndAPin
Number
EndBPin
Number
ConnectedCable
ofAendareweldedto
Pin3and4ofBend.
ofAendareweldedto
Pin5and6ofBend.
lThePin6andPin7(SeeT able4-8)areneededtobeweldedwithtwocables. lTheEndAconnectorshouldbeequippedwithmetaldust-proofcover lThelabelsprintingandpastingshouldsatisfytherequirementsofQ/ZX04.1 13.4Cable
DesigningCriteria–LabelDesigningandUsageRequirements.
MonitoringCable
Thefollowingarethetechnicalspecicationofmonitoringcable:
lTheEndAisa37-pinfemaleconnector. lEndBisanopenendwithoutanyconnector.TheconnectorattheEndBshouldbe
preparedon-siteaccordingtotheon-siterequirements.
lMakesurethatconnectorattheEndAisproperlywelded. lThelabelattachedatbothendsshouldsatisfytherequirementsofZTECable
DesigningCriteria–LabelDesigningandUsageRequirements.
lTable4-9showstheconnectionrelationshipofEndA.
Table4-9ConnectionRelationship
EndA(Pins)ColorSignalDenition
15/16White/blueDrycontact4-/+
17/18White/orangeDrycontact3-/+
19/20White/greenDrycontact2-/+
21/22White/brownDrycontact1-/+
23/24Red/blue485Rx-/+
25/26Red/orange485Tx-/+
OtherPinsarefreeOthercorewiresarefree
4.7.2.2PowerandGroundingCablesInstallationCheck
Context
Ensurethepowerandgroundingcablesinstallationisdoneinaccordancewiththe followingchecks:
4-59
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 40
ZXSDRR8860EGU198UserManual
Steps
1.Thepowerandgroundingcablesarelaidseparatelyfromothercables.Ifthepower andgroundingcablesaretobelaidparallelwithothercables,thenatleastadistance of20cmismaintainedbetweenthem.
2.Thecablelabelsareintactonbothsidesofpowerandgroundingcables.Thelabels areattachedatalmost2cmfromcablecopperlug.
3.Entirepowerandgroundingcablesaremadefromonematerialwithnoconnections inbetween.
4.Asinglegroundingpointonthegroundingbusbarjustconnectstoapieceof equipment.
5.Copperlugsonbothendsofpowerandgroundingcablesaresolderedorpressed rmly.
6.Theshortestroutebetweenthegroundingcablesandgroundingbusbarisadopted.
7.Powerandgroundingcablesatconnectingterminalsandlughandlesareproperly insulatedusingeitherinsulatedtapesorheatshrinktubes.
8.Theredundantlengthofpowerandgroundingcablesiscuttoavoidwrappingeach other.
–EndofSteps–
4.7.2.3OpticalFiberInstallationCheck
Context
Thebercableinstallationshouldmeetthefollowingspecications:
Steps
1.Donotfoldopticalberat90 twistradiusshouldbeatleastgreaterthan90mm.Whereasforopticalberthatisto belaidindoors,minimaltwistradiusshouldbeatleastgreaterthan30mm.
2.Afterinstallation,anysurplusopticalbershouldbeputbackinthebercardfor convenience.
3.Duringinstallation,minimizeopticalbertwistandturn,asmuchaspossible.
4.Thebindingforceshouldbepropertoensurethatbindinggapsareless0.5m.
o
.Foropticalberthatistobelaidoutdoors,minimal
5.Makesurethatlabelsatbothendsofopticalberareintactandclear.
–EndofSteps–
4-60
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 41
4.7.3CheckingMainAntennaSystemInstallation
Steps
1.Ensuretheheightofantennaisconsistentwiththenetworkplanning,andthe installationpositionisconsistentwiththeengineeringdesigndrawing.
2.Ensuretheazimuthanddown-tiltoftheantennaisconsistentwiththeengineering designdrawing.
3.Ensuretheantennaiswithintheprotectionareaoflightningrod.
4.EnsuretheVSWRnotmorethan1.5.
5.Ensureproperconnectionbetweenantennaandjumperaswellasbetweenjumper andmainfeedercorrect.
6.Makesurethatthejumperandantennaatthejunctionkeepstraightwithin30cmat least.
–EndofSteps–
Chapter4Installation
4.8Poweronandoff
4.8.1PoweronPreparation
Context
Makesurethatfollowingconditionsarefullledbeforepowering-onR8860EGU198:
Steps
1.Makesurethatinputpowersupplyiswithintheacceptablerange.
2.MakesurethatpowercableconnectedtoR8860EGU198cabinetisproperly grounded.
–EndofSteps–
Result
Thepreparationtopoweronthecabinetissuccessfullycompleted.
4.8.2PowerON
Context
Performthefollowingstepstopower-ontheR8860EGU198.
4-61
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 42
ZXSDRR8860EGU198UserManual
Steps
1.ThereisnopowerswitchONtheR8860EGU198cabinet.Closetheexternalpower switchtopoweronR8860EGU198.
2.DuringpowerON,ifsomeabnormalphenomenaoccurs,disconnecttheexternal powerswitchortheplugimmediately,andcheckthereason.
–EndofSteps–
4.8.3PowerOFF
Context
PerformthefollowingstepstopowerOFFtheR8860EGU198.
Steps
1.ThereisnopowerswitchontheR8860EGU198cabinet.Disconnecttheexternal powerswitchtopoweroffR8860EGU198.
–EndofSteps–
4-62
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 43
Chapter5
RRUConnectionswith AntennaFeederSystem
TableofContents
TypicalSingle-RRUAntennaFeederSystemCongurations......................................5-1
ConguringRRUwithCommonAntennasandWithoutADTMA.................................5-1
ConguringRRUwithCommonAntennasandADTMA..............................................
ConguringRRUwithElectricalAntennasandWithoutADTMA(I).............................5-3
ConguringRRUwithElectricalAntennasandWithoutADTMA(II)............................
ConguringRRUwithElectricalAntennasandADTMA..............................................5-5
5.1TypicalSingle-RRUAntennaFeederSystem
5-2
5-4
Configurations
Thetypicalcongurationsofasingle-RRUfeedersystemareasfollows:
lTheRRUisconguredwithcommonantennas lTheRRUisconguredwithcommonantennasandAISGdualT owerMounted
Amplier(ADTMA)
lTheRRUisconguredwithelectricalantennas(I) lTheRRUisconguredwithelectricalantennas(II) lTheRRUisconguredwithelectricalantennasandADTMA
5.2ConfiguringRRUwithCommonAntennasand WithoutADTMA
InstalltheRRUclosetotheantennaontherooftop.DirectlyconnecttheRRUtothe antennathrough1/2”feeders,orinsomesituations,5/4”or7/8”feeders.
5-1
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 44
ZXSDRR8860EGU198UserManual
Figure5-1CONNECTINGRRUTOCOMMONANTENNASWITHOUTTWA
5.3ConfiguringRRUwithCommonAntennasand ADTMA
InstalltheRRUunderthetowerandinstalltheantennaonthetower.ConnecttheRRUto theantennathrough5/4”or7/8”feeders.
5-2
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 45
Chapter5RRUConnectionswithAntennaFeederSystem
Figure5-2CONNECTINGRRUTOCOMMONANTENNASANDADTMA
5.4ConfiguringRRUwithElectricalAntennasand WithoutADTMA(I)
InstalltheRRUclosetotheantennaontherooftop.ConnecttheRRUtotheantenna through1/2”feeders,orinsomesituations,5/4”or7/8”feeders.
5-3
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 46
ZXSDRR8860EGU198UserManual
Figure5-3CONNECTINGRRUWITHELECTRICALANTENNAS(I)
5.5ConfiguringRRUwithElectricalAntennasand WithoutADTMA(II)
InstalltheRRUunderthetowerandinstalltheantennaonthetower.ConnecttheRRUto theantennathrough5/4”or7/8”feeders.
5-4
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 47
Chapter5RRUConnectionswithAntennaFeederSystem
Figure5-4CONNECTINGRRUWITHELECTRICALANTENNAS(II)
5.6ConfiguringRRUwithElectricalAntennasand ADTMA
InstalltheRRUunderthetowerandinstalltheantennaonthetower.ConnecttheRRUto theantennathrough5/4”or7/8”feeders.
5-5
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 48
ZXSDRR8860EGU198UserManual
Figure5-5CONNECTINGRRUTOELECTRICALANTENNASANDADTMA
5-6
SJ-20101210110401-002|2011-05-31ZTEProprietaryandCondential
Page 49
Figures
Figure1-1R8860EGU198POSITIONINGSM/UMTSNETWORK..........................1-2
Figure1-2BASESTATION(BBUANDRRU)............................................................
Figure1-3DISTRIBUTEDBASESTATIONSYSTEMSTRUCTURE.........................1-3
Figure1-4RUNNINGENVIRONMENTOFR8860EGU198.....................................1-4
Figure1-5R8860EGU198Appearance...................................................................1-5
Figure1-6OPERA TIONANDMAINTENANCEOFR8860EGU198.........................1-9
Figure3-1ExternalInterfacesatChassisBottom.....................................................3-1
Figure3-2R8860EGU198IndicatorsandButtons....................................................3-3
Figure3-3HARDWARESYSTEM............................................................................
Figure3-4R8860EGU198SOFTWAREARCHITECTURE......................................3-7
Figure4-1PACKINGOFR8860EGU198..............................................................4-16
Figure4-2FLOWOFUNPACKINGANDCHECKING.............................................4-17
Figure4-3R8860EGU198InstallationFlow...........................................................4-18
Figure4-4T akingoutCabinet.................................................................................4-19
Figure4-5BindingCabinetwithRope.....................................................................
Figure4-6HoistingOperationSchematicDiagram..................................................4-20
Figure4-7WALLMOUNTEDINSTALLATIONFORR8860EGU198.......................4-24
1-2
3-4
4-19
Figure4-8POLEMOUNTEDINSTALLATIONFOR1OR2R8860E
GU198s................................................................................................4-25
Figure4-9POLEMOUNTEDINSTALLATIONFOR3R8860EGU198s..................4-25
Figure4-10TheSingleR8860EGU198MountingSolution.....................................4-26
Figure4-1 1TheDoubleR8860EGU198MountingSolution....................................4-26
Figure4-12TheTripleR8860EGU198MountingSolution......................................4-27
Figure4-13R8860EGU198INSTALLATIONFLOW...............................................4-28
Figure4-14HOLINGTEMPLATE...........................................................................4-29
Figure4-15ASSEMBLINGWALL-MOUNTEDINSTALLATIONASSEMBLY...........
Figure4-16FIXINGTHECABINET........................................................................4-31
Figure4-17INST ALLINGCLAMPASSEMBL Y.......................................................4-32
Figure4-18FIXINGTHECABINET........................................................................4-33
Figure4-19INST ALLINGCLAMPASSEMBL Y.......................................................4-34
Figure4-20ASSEMBLINGWALL-MOUNTEDINSTALLATIONASSEMBLY...........4-35
Figure4-21FIXINGTHECABINET........................................................................
4-30
4-35
I
Page 50
ZXSDRR8860EGU198UserManual
Figure4-22INST ALLINGMOUNTINGBRACKETASSEMBLY...............................4-36
Figure4-23ASSEMBLINGWALL-MOUNTEDINSTALLATIONASSEMBLY...........
Figure4-24FIXINGTHECABINET........................................................................4-37
Figure4-25FixingtheMountingPiece....................................................................4-38
Figure4-26MountingR8860EGU198....................................................................4-39
Figure4-27MountingbaseDoubleUnitSolution...............................................4-40
Figure4-28MountingbaseSingleUnit+LightningProtectorBoxSolution............
Figure4-29MountingTwoR8860EGU198.............................................................4-41
Figure4-30MountingoneR8860EGU198andOneLightningProtectorBox...........4-42
Figure4-31FixingtheLightningProtectorBox........................................................4-42
Figure4-32MountingTwoR8860EGU198.............................................................4-43
Figure4-33MountingtheExpansionPiece.............................................................4-43
Figure4-34AttachingtheMountingbase................................................................4-44
Figure4-35AttachtheR8860EGU198totheMountingbase.................................
Figure4-36INST ALLINGPROTECTIONSHADE...................................................4-46
Figure4-37ExternalCableInstallationFlow...........................................................4-48
Figure4-38PowerCablestructure.........................................................................4-49
4-37
4-40
4-45
Figure4-39GroundingCableStructure..................................................................4-50
Figure4-40Earth-networkCopperBar(Unit:mm)..................................................4-50
Figure4-41FiberConnectionbetweenR8860EGU198andBBU..........................
Figure4-42OpticalFiberInstallation.......................................................................4-52
Figure4-43FiberConnectionbetweenR8860EGU198s.......................................4-52
Figure4-44OpticalFiberInstallation.......................................................................4-53
Figure4-45EnvironmentMonitoringCable.............................................................4-54
Figure4-46AviationJackAppearance....................................................................4-54
Figure4-47AISGControlCableStructure..............................................................
Figure4-48FrequencyPointExtensionCable........................................................
Figure4-49RFJumperInstallation.........................................................................
Figure5-1CONNECTINGRRUTOCOMMONANTENNASWITHOUTTWA...........5-2
Figure5-2CONNECTINGRRUTOCOMMONANTENNASANDADTMA...............5-3
Figure5-3CONNECTINGRRUWITHELECTRICALANTENNAS(I).......................5-4
Figure5-4CONNECTINGRRUWITHELECTRICALANTENNAS(II)......................5-5
Figure5-5CONNECTINGRRUTOELECTRICALANTENNASANDADTMA
...............................................................................................................5-6
4-51
4-55
4-56
4-57
II
Page 51
Tables
Table1-1EQUIPMENTSRELA TEDTOR8860EGU198RUNNING.........................1-4
Table2-1WindSpeed@150km/h...........................................................................
Table2-2WindSpeed@240km/h...........................................................................2-2
Table3-1ExternalInterfaces....................................................................................3-2
Table3-2IndicatorsandButtons...............................................................................3-3
Table3-3COMPOSITIONOFM8206CABINETHARDWARE..................................3-5
Table4-1SafetySymbolsDescription.......................................................................4-3
Table4-2ToolandMeterList..................................................................................4-10
Table4-3INSTALLATIONACCESSORIESOFR8860EGU198ANDTHEIR
FUNCTIONS..........................................................................................4-22
Table4-4R8860EGU198ExternalCableConnectionRelationship........................
Table4-5ColorandSpecication...........................................................................4-49
Table4-6CablePinDescription.............................................................................4-54
Table4-7AISGControlCableDescription..............................................................4-55
Table4-8ConnectionRelationship..........................................................................4-58
Table4-9ConnectionRelationship..........................................................................4-59
2-2
4-46
III
Page 52
Thispageintentionallyleftblank.
Tables
Page 53
Glossary
AISG
-AntennaInterfaceStandardsGroup
Abis
-AbisInterfacebetweenBSCandBTS
BBU
-BaseBandUnit
BSC
-BaseStationController
BTS
-BaseTransceiverStation
CN
-CoreNetwork
DPD
-DigitalPre-Distortion
EDGE
-EnhancedDataratesforGSMEvolution
FP
-FrameProtocol
GPRS
-GeneralPacketRadioService
GPS
-GlobalPositioningSystem
GSM
-GlobalSystemforMobileCommunication
HSPA
-HighSpeedPacketAccess
Iub
-InterfacebetweenanRNCandaNodeB
LTE
-LongT ermEvolution
MS
-MobileStation
NodeB
-NodeB
V
Page 54
ZXSDRR8860EGU198UserManual
OAM
-Operation,AdministrationandMaintenance
PA
-PowerAmplier
RF
-RadioFrequency
RNC
-RadioNetworkController
RRU
-RemoteRadioUnit
UE
-UserEquipment
UMTS
-UniversalMobileTelecommunicationSystem
Uu
-Uinterfaceinmobilenetwork
VI