Not e: Not al l the dev ices hav e the fin gerpr int cov er. The real
pro duct pr evail s.
Procedure to be followed before installation
38.0
7.1
83.3
STEP 1
72.0
Remove both the screws
121.3
1
61.0
12V
RED
GND
BLACK
YELLOW
485+
PURPLE
485-
GND
BLACK
Page 3
Installation
Take out the front panel as shown below
STEP 2
Method 1: Mounting on the standard Single gang junction box
Lay the cables from the desired hole in Single gang junction box and fix the machine part
to the box part.
The Single gang junction box's size
recommendations:
Location column: 83.3mm
Inside of the box Depth: Minimum 36mm
Outside the box size: maximum length
120mm , maximum width 76mm
76
mm
m
m
3
3.
8
0mm
2
1
m
36m
2
Page 4
Method 2: Mounting inside the wall
Place the mounting sticker
STEP 1
to the place where device
needs to be installed
Fixing Hole
The depth o f the ins talla tion
groove i s 36mm
Instruction for the Mounting Paper
Before the device is fastened, please
stick the paper to the place where you
want to install it, then make holes and
lay cables according to the mounting
paper.
Fixing Hole
10
Moun ting Pap er
(onl y for your r efere nce)
11
If cables need to be laid from
STEP 3STEP 4
behind then it must be done
before installing
12V
RED
GND
BLACK
YELLOW
485+
PURPLE
485-
GND
BLACK
After installing the back plate attach the machine part in the
STEP 5
same reverse manner as shown in previous page
STEP 2
3
Drill fixing holes and dig mounting
groove deep of 36mm
wall
m
6m
3
Install the device with the screws
Page 5
Wiring Terminals
ProF P is an inn ovati ve Silk I D reader. I t need s to be conn ected t o a host ma chine
so th at fing erpri nt info rmati on can be t ransfe rred th rough R s485.
Rea der wir es nome nclat ure and Di p Switc h
6
5
4
Dip S witch
3
1 2
12V
RED
GND
BLACK
YELLOW
485+
PURPLE
485-
GND
BLACK
1. Co nnect ion wit h a Contro l Panel.
RED 12 V
BLAC K GND
YELLO W 485+
PURP LE 485-
BLAC K GND
SWITCH
EXT
RS485
PC
RS485
Conn ected a s inBIO P ro Read er(wi th Exte rnal 48 5), max imum 8 re aders
can be c onnec ted. The r eader r equire s a separ ate pow er supp ly.
+12V
EXT
GND
485-
PWR
STATE
485+
+
-
DC12V
1 2 8
+
-
DC12V
so on.. ....
4
+
-
Page 6
Working Principle
> Dip Switch setting with control panel
Address
Switch Se ttingSwitch Se tting
Address
Terminal
Resistance
1
6
5
4
8
3
4
12V
RED
GND
BLACK
YELLOW
485+
PURPLE
485-
GND
BLACK
Number 1, 2, 3, 4 of the dip switch are used to set the address of RS485, 5 is the
reset switch, and 6 is the Terminal Resistance.
Number 5 is the reset switch: dial up and dial down. The machine will restart and
reset successfully
2
1 2
1
1 2
2
1 2
3
1 2
4
1 2
The right side figure shows the address number setting.
Number 6 switch is used to set the terminal resistance in RS485.
Communication: If the 485 communication wire is longer, than 100 meters, it is
needed to set the number 6 dip switch of the last reader to ON state, that is
parallel a terminal resistance of 120 ohm between 485+ and 485-.
5
5
3
4
5
6
3
4
5
6
3
4
5
6
3
4
5
6
1 2
3
4
6
1 2
3
4
7
1 2
3
4
8
1 2
3
4
5
6
5
6
5
6
5
6
Page 7
2. Connection with a Standalone Access Controller
+12V
GND
485B
GND
485A
1
+12V
GND
4
1
GND
485A
485B
5
When using ProFP with Standalone access controller device, please move the
dial code β1β to the ON position as shown above.
+12V
GND
GND
485+
485-
6
Page 8
Verification Proccess
Connection with the controller:
Unsuccessful: LED flashes blue light twice every one second.
Successfully: LED flashes blue light once every one second.
When verifying the fingerprint or punching the card:
Successful Verification:
Authentication error:
Data Error:
Timeout:
Authentication failed: Red LED, two short BEEP
No rights: Red LED, three short BEEP
Verify unfinished: Red LED flashes three times
Green LED lights, short BEEP
Red LED lights, two short and a long BEEP
Red LED lights, one short and a long BEEP
Red LED lights, four short BEEP
Safety Precautions
1. Power cable should be connected at last, after all the wiring. If the device is
working abnormally, immediately shutdown the device.
2. Please read the terminals description and wiring by rule strictly. Any damage
caused by improper operations will be out of the range of our guarantee.
3. Please connect the βGNDβ before all the other wiring especially under the
serious electrostatic environment.
4. Keep the exposed part of wire less than 5mm to avoid unexpected connection,
and result in machinery damage.
5. If the distance between power supply and device is little long, please do not
use the Internet cable or other types of cable instead. When choosing the
power supply cable, you should consider that the transmission distance may
cause voltage attenuation.
7
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.