Installation Guide
inBIO-Series
Access Control Panels
&
ZKAccess 5.2 software
ZKAccess.com
2
|
|
|
|
|
IN GND |
IN GND |
IN GND |
IN GND |
+12V GND 485485+ |
AUX 1 |
AUX 2 |
AUX 3 |
AUX4 |
EXT |
|
|
|
|
|
|
|
|
|
|
|
PWR RUN ACT GRD |
IN GND |
BEEP GLED WD1 WD0 GND +12V |
IN GND |
BEEP GLED WD1 WD0 GND |
+12V |
IN GND |
BEEP GLED WD1 WD0 |
GND +12V |
IN GND |
BEEP GLED WD1 WD0 GND +12V |
STATE |
BUTTON 1 |
READER 1 |
BUTTON 2 |
READER 2 |
|
BUTTON 3 |
READER |
3 |
BUTTON 4 |
READER 4 |
EXT |
PC |
CARD |
RUN |
POWER |
|
RS485 |
RS485 |
||||
|
|
|
Best Security Solution for the World
Advanced Access Control
LAN |
SWITCH |
PC |
AUXOUT1 |
AUXOUT2 |
AUXOUT3 |
AUXOUT4 |
|
LOCK1 |
|
LOCK2 |
|
LOCK3 |
|
LOCK4 |
LOCK |
POWER |
|||||||||||||||
|
485+ |
485SGND |
NO COM NC |
NO COM NC |
NO COM NC |
NO COM NC |
SEN GND NO COM NC |
SEN GND NO COM NC |
SEN GND NO COM NC |
SEN GND NO COM NC |
V+ V- |
+12V GND |
|||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 Screws & Anchors |
2 Screwdriver |
4 Diode |
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE
3
CONTENT
What’s in the Box........................................................................ |
2 |
Optional accessories................................................................ |
4 |
Safety Precautions..................................................................... |
5 |
Product PIN Diagram.............................................................. |
6 |
LED Indicators............................................................................... |
7 |
Product Dimension.................................................................. |
8 |
Installation of Panel & Cabinet......................................... |
9 |
Wiring Legend.......................................................................... |
10 |
Power Wiring Diagram ....................................................... |
11 |
FR1200 Connection.............................................................. |
12 |
DIP Switch Setting for FR1200 Device ID.............. |
13 |
Wiegand Connection.......................................................... |
14 |
REX Connections..................................................................... |
15 |
Lock Connection..................................................................... |
16 |
Normally Open Lock Powered From Lock Terminal.......... |
16 |
Normally Closed Lock Powered From Lock Terminal....... |
16 |
Switching Wet Contact to Dry Contact................................ |
17 |
Connecting a lock with external power supply................. |
18 |
Aux. I/O connection.............................................................. |
19 |
Aux. Input Connection.............................................................. |
19 |
Aux. Output Connection........................................................... |
19 |
Ethernet Connection .......................................................... |
20 |
LAN Connection.......................................................................... |
20 |
Direct connection....................................................................... |
20 |
RS485 Connection ................................................................ |
21 |
Restore factory setting............................................................... |
22 |
DIP Switch Setting.................................................................. |
23 |
RS485 Address.............................................................................. |
23 |
Terminal Resistance.................................................................... |
23 |
Typical Installation.................................................................. |
24 |
Troubleshooting...................................................................... |
25 |
PC 485 Setting Table............................................................. |
26 |
Electrical Specifications ..................................................... |
28 |
Specifications ............................................................................ |
29 |
ZKAccess 5.2
software
Installation and Setup
starts at page 30
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE
4
Wiegand Card Reader |
Prox Card |
RS485 Convertor |
K1-1 Exit Button |
ZK4500 Enrollment reader |
CR10E Card Enroller |
FR1200 FP & Prox Reader |
inBIO Cabinet |
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE
5
The following precautions are to keep user’s safe and prevent any damage. Please read carefully before installation
Do not install the device in a place subject to direct sun light, humidity, dust or soot
Do not place a magnet near the product. Magnetic objects such as magnet, CRT, TV, monitor or speaker may damage the device.
Do not place the device next to heating equipment
Be careful not to let liquid like water, drinks or chemicals leak inside the device.
Do not let children touch the device without supervision
Do not drop or damage the device
Do not disassemble, repair or alter the device.
Do not use the device for any other purpose than specified.
Clean the device often to remove dust on it. In cleaning, do not splash water on the device but wipe it out with smooth cloth or towel.
Contact your supplier in case of a problem.
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE
6
|
|
|
|
4 Aux Inputs |
|
|
|
FR1200 Fingerprint Reader |
|
|
State Indictor #1 Door Card Reader |
|
|
#1 Door Exit Button |
#2 Door Exit Button |
|
|
#2 Door Card Reader |
#3 Door Exit Button |
|
|
#3 Door Card Reader |
#4 Door Exit Button |
|
|
#4 Door Card Reader |
|||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
IN GND |
IN GND |
IN GND |
IN GND |
+12V GND 485485+ |
AUX 1 |
AUX 2 |
AUX 3 |
AUX4 |
EXT |
PWR RUN ACT GRD |
IN GND |
BEEP GLED WD1 WD0 GND +12V |
IN GND |
BEEP GLED WD1 WD0 GND |
+12V |
IN GND |
BEEP GLED WD1 WD0 |
GND +12V |
IN GND |
BEEP GLED WD1 WD0 GND +12V |
STATE |
BUTTON 1 |
READER 1 |
BUTTON 2 |
READER 2 |
|
BUTTON 3 |
READER |
3 |
BUTTON 4 |
READER 4 |
EXT |
PC |
CARD |
RUN |
POWER |
|
RS485 |
RS485 |
||||
|
|
|
Best Security Solution for the World
Advanced Access Control
LAN |
SWITCH |
PC |
AUXOUT1 |
|
AUXOUT2 |
|
AUXOUT3 |
AUXOUT4 |
|
LOCK1 |
|
LOCK2 |
|
LOCK3 |
|
LOCK4 |
LOCK |
POWER |
|||||||||||||||
|
485+ |
485SGND |
NO COM NC |
|
NO COM NC |
|
NO COM NC |
NO COM NC |
SEN GND NO COM NC |
SEN GND NO COM NC |
SEN GND NO COM NC |
SEN GND NO COM NC |
V+ V- |
+12V GND |
|||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SD Card Slot |
LINK LED Ethernet Port |
ACT LED DIP Switches |
RS485 Communication |
4 Aux Output |
4 Lock & Door Sensor |
Lock Power inBIO Power |
Figure 1
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE
LED Indicators
1 2 3 4
O
Figure 2
1 2 3 4
O
Figure 3
EXT |
PC |
RS485 |
RS485 |
Figure 4
EXT |
PC |
RS485 |
RS485 |
Figure 5
RUN |
POWER |
Figure 6
RUN |
POWER |
Figure 7
CARD |
RUN |
Figure 8
7
LINK Solid Green LED indicates TCP/IP communication is normal
Flashing (ACT )Yellow LED indicates data communication is in progress
EXT RS485 (TX/RX) Flashing Yellow & Green LED indicates communication is in progress
PC RS485 (TX/RX) Flashing Yellow & Green LED indicates communication is
in progress
Flashing (POWER) Red LED indicates the panel is powered on.
Flashing (RUN) Green LED indicates that panel is in normal working state.
Flashing (CARD) Yellow LED indicates that the card is read by the panel.
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE
8
inBIO-160 |
inBIO-260 |
inBIO-460 |
|
|
|
|
|
EXT RS485 |
|
|
|
|
v |
|
|
|
|
|
Ad |
PC RS485 |
|
|
|
|
anced |
CARD |
|
|
|
|
Access |
RUN |
|
|
|
|
|
|
|
|
|
|
Control |
POWER |
|
|
|
|
||
|
|
|
|
|
|
7.125in |
(181mm) |
|
|
|
EXT RS485 |
|
|
|
8.89in |
|
|
|
(226mm) |
|
EXT RS485 |
|
PC RS485 |
v |
|
v |
|
Ad |
PC RS485 |
Ad |
CARD |
anced |
CARD |
anced |
|
Access |
RUN |
Access |
RUN |
Control |
POWER |
Control |
POWER |
4.17in (106mm) |
4.17in (106mm) |
4.17in (106mm) |
1.42in (36mm) |
Figure 9
inBIOMetal Cabinet
|
13in |
|
(330mm) |
15.7in (400mm) |
3.56in |
|
|
|
(90.5mm) |
Figure 10 |
|
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE
9
Installation of Panel & Cabinet
Cable Conduit |
(Punch Hole for cables) |
Advanced Access Control
-- +
Temper Switch
inBIO Panel
Heat Dissipation Grill |
Power Supply
Backup Battery
Figure 11
Step 1 |
Step 2 |
Step 3 |
Pass the cable through holes |
Mount the Metal Cabinet |
Insert the inBIO Panel as it shown |
State Indicators |
Mounting Holes |
Inserting Panel to Rail |
1
2
Mounting Rail
Figure 12
We recommend drilling the mounting plate screws into solid wood (i.e. stud/beam). If a stud/beam cannot be found, then use the supplied drywall plastic mollies (anchors).
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE
10
Wiring Legend
Detector |
IR Sensor |
Exit Button |
Card Reader |
Exit Button |
Card Reader |
FIRE ALARM |
PUSH |
PUSHT |
|
OT |
|
T
O
T
HSUP
No Touch |
EXIT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
IN GND |
IN GND |
IN GND |
IN GND |
|
+12V GND 485485+ |
|||||||||||
AUX 1 |
AUX 2 |
AUX 3 |
AUX4 |
|
|
EXT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PWR RUN ACT GRD |
IN GND |
BEEP GLED WD1 WD0 GND +12V |
|
IN GND |
BEEP GLED WD1 WD0 GND |
+12V |
IN GND |
BEEP GLED WD1 WD0 |
GND +12V |
IN GND |
BEEP GLED WD1 WD0 GND +12V |
|||||
STATE |
BUTTON 1 |
|
READER 1 |
BUTTON 2 |
READER 2 |
|
BUTTON 3 |
READER |
3 |
BUTTON 4 |
|
READER 4 |
EXT |
PC |
CARD |
RUN |
POWER |
|
RS485 |
RS485 |
||||
|
|
|
Best Security Solution for the World
Advanced Access Control
LAN |
SWITCH |
PC |
AUXOUT1 |
AUXOUT2 |
AUXOUT3 |
AUXOUT4 |
|
LOCK1 |
|
LOCK2 |
|
LOCK3 |
|
LOCK4 |
LOCK |
POWER |
|||||||||||||||
|
485+ |
485SGND |
NO COM NC |
NO COM NC |
NO COM NC |
NO COM NC |
SEN GND NO COM NC |
SEN GND NO COM NC |
SEN GND NO COM NC |
SEN GND NO COM NC |
V+ V- |
+12V GND |
|||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RS485 |
ALARM |
Ethernet Cable |
485 Convertor |
Floodlight |
Normally Open Lock |
Normally Close Lock |
12V DC Power Supply |
12V DC Power |
|
|
|
Figure 13 |
|
|
|
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE
11
Without Backup Battery
Advanced Access Control
LOCK POWER
V+ V- |
+12V GND |
AC 24VAC
N L + - BT+ BT-
Ground
Switching Power Supply
Figure 14
With Backup Battery
LOCK POWER
V+ V- |
+12V GND |
Advanced Access Control
AC 24VAC
-- +
N L + - BT+ BT-
Ground
Switching Power Supply
Figure 15
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE
12
FR1200 Connection
ETHERNET |
X4
GND
|
|
|
|
|
|
|
+12V |
|
LAN |
|
|
2AUX2 1 AUX |
IN |
EXT |
GND |
|
|
|
GND |
|
|||
|
|
|
|
|
GND |
|
485- |
|
|
|
|
|
IN |
|
|
|
|
|
|
AUX |
IN |
|
|
NC |
AUXOUT3AUXOUT2AUXOUT1PCSWITCH |
|
EXT RS485 |
3 |
GND |
BUTTO |
|
|
BUTTON1READERSTATE1BUTTONEXTAUX4 |
IN |
485+ |
||||
|
|
|
|
|
|
||
|
|
|
|
|
GND |
|
|
|
|
|
|
|
+12V |
|
|
|
|
|
|
|
GND |
|
|
|
|
|
|
|
485- |
|
|
485+ |
|
|
|
|
485+ |
|
|
485- |
|
|
|
|
|
|
|
SGND |
|
|
|
|
|
|
|
NO |
|
|
|
|
PWR |
|
|
COM |
|
|
|
|
RUN |
|
|
NC |
|
|
|
|
ACT |
|
|
NO |
|
|
|
|
GRD |
|
|
COM |
|
|
|
|
IN |
|
|
NC |
|
|
|
|
GND |
|
|
NO |
|
|
|
|
BEEP |
|
|
COM |
|
|
|
|
GLED |
|
|
|
|
|
|
|
WD1 |
|
|
SEN |
AUXOUT4 |
|
PC RS485 |
|
WD0 |
|
|
|
|
GND |
|
|
|||
NO |
|
|
|
|
GND |
|
|
COM |
|
|
|
|
+12V |
|
|
NC |
|
|
|
|
IN |
|
|
GND |
LOCK1 |
|
|
2READER |
GND |
|
|
SEN |
|
|
|
|
|||
NO |
|
|
|
|
BEEP |
|
|
COM |
|
|
|
|
GLED |
|
|
NC |
|
|
|
|
WD1 |
|
|
|
|
|
|
|
WD0 |
|
|
GND |
LOCK2 |
Adv |
CARD |
3BUTTON |
+12V |
|
|
NO |
|
|
|
||||
COM |
|
|
|
|
IN |
|
|
NC |
|
|
|
|
GND |
|
|
SEN |
|
|
|
|
BEEP |
|
|
GND |
POWERLOCKLOCK4LOCK3 |
ControlAccessanced |
POWERRUN |
4READER4BUTTON3READER |
GLED |
|
|
NO |
WD1 |
|
|
||||
COM |
|
|
|
|
WD0 |
|
|
NC |
|
|
|
|
GND |
|
|
SEN |
|
|
|
|
+12V |
|
|
|
|
|
|
|
|
|
|
GND |
|
|
|
|
IN |
|
|
NO |
|
|
|
|
GND |
|
|
COM |
|
|
|
|
BEEP |
|
|
NC |
|
|
|
|
GLED |
|
|
V+ |
|
|
|
|
WD1 |
|
|
V- |
|
|
|
|
WD0 |
|
|
+12V |
|
|
|
|
GND |
|
|
GND |
|
|
|
|
+12V |
|
|
|
|
12V DC |
12V DC |
1 FR1200 |
2 FR1200 |
3 FR1200 |
8 FR1200 |
|
|
Figure 16 |
|
inBIO panels can not supply power to more than 2 FR1200 readers. Addidional FR1200 will require external power supplies.
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE
13
DIP Switch Setting for FR1200 Device ID
|
|
6 |
|
|
5 |
|
|
4 |
|
|
3 |
|
|
2 |
|
|
1 |
|
|
ON |
|
|
DIP Switch |
|
|
Figure 17 |
Address |
Switch Settings |
Address |
RS485 Terminal Resistance
8
4
2
1
Switch Settings
ON |
ON |
1 |
|
|
|
|
|
5 |
|
|
|
|
|
1 |
2 |
3 |
4 |
5 |
6 |
1 |
2 |
3 |
4 |
5 |
6 |
ON |
|
|
|
|
|
ON |
|
|
|
|
|
2 |
|
|
|
|
|
6 |
|
|
|
|
|
1 |
2 |
3 |
4 |
5 |
6 |
1 |
2 |
3 |
4 |
5 |
6 |
3 |
ON |
|
|
|
|
|
|
|
|
|
|
|
|
7 |
ON |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
1 |
|
2 |
|
3 |
|
4 |
|
5 |
|
6 |
|
|
|
|
1 |
|
2 |
|
3 |
|
4 |
|
5 |
|
6 |
|
ON |
|
|
|
|
|
ON |
|
|
|
|
|
4 |
|
|
|
|
|
8 |
|
|
|
|
|
1 |
2 |
3 |
4 |
5 |
6 |
1 |
2 |
3 |
4 |
5 |
6 |
Important Notes
1.There are six DIP switches on the back of FR1200, Switches 1-4 is for RS485 address, switch 5 is reserved, switch 6 is for reducing noise on long RS485 cable.
2.Set the odd number for IN reader, and the even number for OUT reader (for eg. For two readers for one doorthe RS485 address 1 is for IN reader, RS485 address 2 is for OUT reader)
3.If FR1200 is powered from inBIOPanel, the length of wire should be less than 100 meters or 330 ft.
4.The External RS485 interface can supply maximum 500mA current, The FR1200’s startup current is 240mA. So inBIO-Panel only can only power two FR1200s.
5.If the cable length is more than 200 meters or 600 ft , the number 6 switch should be ON as below
ON |
ON |
|
|
|
|
|
|
Distance: More than 200 meters |
|
|
|
|
|
1 |
2 |
3 |
4 |
5 |
6 |
1 |
2 |
3 |
4 |
5 |
6 |
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE
14
Wiegand Connection
DC+(6-14V) |
GND |
Wiegand D0 |
Wiegand D1 |
Green LED |
Beeper |
Wiegand Card Reader
GND |
BEEP GLED WD1 WD0 GND +12V |
IN GND |
ON 1 |
READER 1 |
BUTT |
|
|
|
|
|
IN GND |
IN GND |
IN GND |
IN GND |
+12V GND 485485+ |
AUX 1 |
AUX 2 |
AUX 3 |
AUX4 |
EXT |
PWR RUN ACT GRD |
IN GND |
BEEP GLED WD1 WD0 GND +12V |
IN GND |
BEEP GLED WD1 WD0 GND |
+12V |
IN GND |
BEEP GLED WD1 WD0 |
GND +12V |
IN GND |
BEEP GLED WD1 WD0 GND +12V |
STATE |
BUTTON 1 |
READER 1 |
BUTTON 2 |
READER 2 |
|
BUTTON 3 |
READER |
3 |
BUTTON 4 |
READER 4 |
EXT |
PC |
CARD |
RUN |
POWER |
|
RS485 |
RS485 |
||||
|
|
|
Best Security Solution for the World
Advanced Access Control
LAN |
SWITCH |
PC |
AUXOUT1 |
AUXOUT2 |
AUXOUT3 |
AUXOUT4 |
LOCK1 |
LOCK2 |
LOCK3 |
LOCK4 |
LOCK |
POWER |
|
|
485+ |
485SGND |
NO COM NC |
NO COM NC |
NO COM NC |
NO COM NC |
SEN GND NO COM NC |
SEN GND NO COM NC |
SEN GND NO COM NC |
SEN GND NO COM NC |
V+ V- |
+12V GND |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Figure 18
inBIO-Series Access Control Panels & ZKAccess 5.2 software INSTALLATION GUIDE