Water-proof IP65 rated reader for outdoor installation
Standard Weigand Input and Output interfaces are compatible with most 3
bit Weigand readers and access control panels.
USB HOST port makes offline data backup/management fast & easy.
Relay contacts for alarm, electric lock, exit button, and wired door bell.
Reads fingerprint, RFID card and Password.
rd
party 26-
Specifications:
201 Circle Drive N, Suite 116 Piscataway, NJ 08854 Tel: 732-412-6007 Fax: 732-412-6008
www.zkaccess.com
TF1700 Fingerprint
Terminal
Metallic Mounting Plate
Wall Mounting Screws and
Holders
Star-shape Screw for
Mounting Plate
Star-shape Screw Driver
Mini-USB Cable
Software CD
Installation Guide
Mounting Paper
Basic Contents:
201 Circle Drive N, Suite 116 Piscataway, NJ 08854 Tel: 732-412-6007 Fax: 732-412-6008
www.zkaccess.com
FR1200 Fingerprint Slave
Reader
K1 Exit Button
12V3A Power
Adaptor
Mifare
Integrated Module and
Card
Optional Accessories
201 Circle Drive N, Suite 116 Piscataway, NJ 08854 Tel: 732-412-6007 Fax: 732-412-6008
www.zkaccess.com
Front
Side
201 Circle Drive N, Suite 116 Piscataway, NJ 08854 Tel: 732-412-6007 Fax: 732-412-6008
www.zkaccess.com
Rear
Installation Diagram
201 Circle Drive N, Suite 116 Piscataway, NJ 08854 Tel: 732-412-6007 Fax: 732-412-6008
www.zkaccess.com
Product Dimensions (mm)
201 Circle Drive N, Suite 116 Piscataway, NJ 08854 Tel: 732-412-6007 Fax: 732-412-6008
www.zkaccess.com
PIN
Description
Wire
1
+12V DC
RED
2
GND
GREEN
PIN
Description
Wire
1
RJ45-1
YELLOW
2
RJ45-2
GREEN
3
RJ45-3
RED
4
RJ45-6
BLACK
PIN
Description
Wire
1
Weigand output D0
GREEN
2
Weigand output D1
RED
3
GND
BLACK
4
RS485+
BLUE
5
RS485-
YELLOW
PIN
Description
Wire
1
NO1
BLUE
2
COM1
RED
3
NC1
YELLOW
4
NO2
ORANGE
5
COM2
GREEN
PIN
Description
Wire
1
BELL-
PURPLE
2
BELL+
BROWN
3
DOOR SENSOR
WHITE
4
GND
BLACK
5
EXIT BUTTON
GREY
PIN
Description
Wire
1
+12V DC
RED
2
GND
BLACK
3
Weigand input D0
WHITE
4
Weigand input D1
GREEN
5
Red LED
BLUE
6
Green LED
GREY
7
Beep
PURPLE
Cable Specification
201 Circle Drive N, Suite 116 Piscataway, NJ 08854 Tel: 732-412-6007 Fax: 732-412-6008
www.zkaccess.com
Menu
►User Manage
Options
PenDrive Mng
Important Notes
Use regulated 12V DC 3A power source (supplied from control panel or separately
purchased power supply).
Please make sure to protect TF1700 against vandalism.
Mounting the Unit
Place the unit approximately 5 ½ feet above the ground level if permissible so that the
users are comfortable in using the reader with least chances of error
Pull the power and network cables from the back of the wall and connect them to the
appropriate pigtail wires supplied with the reader
Remove the screw at the bottom of the reader to detach the back plate.
Install the back plate of the unit on to the wall and connect the power, network and other
necessary cables on the back of the unit.
Secure the reader with the back plate by fixing the tamper proof screw at the bottom of the
reader.
Hardware Setup
Power on the reader by supplying 12V DC to the power and GND pins on the back of the
reader. The power supply is not supplied with the reader. Please make sure that the power
requirements are strictly met to avoid permanent damage to the reader.
After the reader is powered on, the display will show the date, day and time on the screen.
Date and Time Setup
To change the date and time, press the Menu key;
The Menu will then display.
Scroll with the ▲/▼ keys and place the cursor (►) alongside “Options”. Press the OK key.
Scroll with the ▲/▼ keys and place the cursor (►) alongside “System Opt”. Press the OK key.
Scroll with the ▲/▼ keys and place the cursor (►) alongside “Date Time”. Press the OK key.
Once in the YYYY-MM-DD 24H screen, use the ▲/▼ keys to move between data fields.
Set the data and time.
Press the OK key to accept changes.
Press the ESC key to cancel changes.
201 Circle Drive N, Suite 116 Piscataway, NJ 08854 Tel: 732-412-6007 Fax: 732-412-6008
www.zkaccess.com
Not flat
Not centered
Not flat
Not centered
Fingerprint Enrollment:
Users have No “administrative” access to the TF1700, but can gain door access and have his/her
attendance recorded.
Note:
Until an “admin” is enrolled in the TF1700, All “users” enrolled on the TF1700 “temporarily” have
administrative access. Therefore it is important to enroll an “admin” on the TF1700 soon after
initial installation.
“Users” can enroll with three credentials;
Fingerprint
RFID card
Password
Suggestions for proper finger placement:
The user’s finger should completely cover the sensor. The finger should be placed flat and in
the center of the sensor. The finger should cover at least 80% of the sensor as shown below:
The finger should NOT be placed in the following positions:
201 Circle Drive N, Suite 116 Piscataway, NJ 08854 Tel: 732-412-6007 Fax: 732-412-6008
www.zkaccess.com
EnrollFP
New Enroll?
ESC OK
New Enroll
UserID: 000000001
ESC OK
New Enroll
000000001-0
Place Finger...
ESC/EXIT
New Enroll
000000001-0
Remove Finger
ESC/EXIT
New Enroll
000000001-0
Second Press
ESC/EXIT
New Enroll
000000001-0
Remove Finger
ESC/EXIT
Enroll Fingerprint (for Users)
To start fingerprint enrollment, press the Menu key on the TF1700.
Scroll with the ▲/▼ keys and place the cursor (►) alongside “User Manage”. Press the OK key.
Scroll with the ▲/▼ keys and place the cursor (►) alongside “Enroll User”. Press the OK key.
Scroll with the ▲/▼ keys and place the cursor (►) alongside “Enroll FP”. Press the OK key.
The TF1700 with prompt you;
If this is a NEW User, then press OK.
The TF1700 will then prompt you with the next available User ID.
If no user has yet been enrolled on the TF1700, the next available User ID will be 000000001.
Press the OK key to accept 000000001, or manually key in a different number if desired.
The TF1700 will then prompt;
Place you finger on the sensor for 1 second.
After the TF1700 scans your fingerprint successfully, it will “beep” and then prompt you briefly with;
Then you will be prompted;
Remove your finger, and then place you finger on the sensor a 2nd time. Again, you will be
prompted briefly;
201 Circle Drive N, Suite 116 Piscataway, NJ 08854 Tel: 732-412-6007 Fax: 732-412-6008
www.zkaccess.com
New Enroll
000000001-0
ESC OK(Save)
New Enroll
Continue?
ESC OK
Backup Enroll
UserID:000000001
ESC OK
Verify
UserID 000000001
Verified
Remove your finger, and then place your finger on the sensor a 3rd and final time. You will then be
prompted;
Press the OK key to accept the newly enrolled finger.
UserID 000000001 has now been successfully enrolled with one fingerprint.
The TF1700 will then prompt you with;
If you wish to continue enrolling additional users, press the OK key and follow the same procedures.
If you’re finished enrolling additional users, press the ESC key.
When pressing ESC key, the TF1700 will prompt you;
If you wish to add a “backup finger” for UserID 000000001 press the OK key.
Note:
Ideally, we recommend enrolling two fingers of each hand so that in case of injury of one hand the
user can use the finger of the other hand as a backup. It is recommended to enroll left or right
index finger and let middle or right middle fingers.
After enrolling one or more fingerprints to UserID 000000001 press the ESC key.
You will note pressing the ESC key takes you back to the previous menu;
Continue pressing the ESC key until you return to the Start-Up window;
Test the newly enrolled fingerprint by having UserID 000000001 place his/her finger on the sensor.
If successful, the TF1700 will prompt with a beep, and the screen will display;
Note:
The TF1700 will make a note in its transaction log that UserID 000000001 accessed the TF1700.
This information can be used for Time & Attendance software applications and/or for door access.
201 Circle Drive N, Suite 116 Piscataway, NJ 08854 Tel: 732-412-6007 Fax: 732-412-6008
www.zkaccess.com
Note:
If the fingerprints of certain users are unable to be enrolled successfully, you may use the Enroll
Pwd or Reg RFID option for those users instead of Enroll FP.
This will allow the user to choose RFID card or password instead of his/her fingerprint.
Once all the users are enrolled, it is advised to enroll a system Admin.
Once and admin is enrolled, normal user will no longer be able to access the Menu and make
unauthorized changes.
The enrollment procedure for admin is same as for user. But instead of selecting Enroll User, scroll
down and select Enroll Admin.
Press the Menu key to begin;
Scroll with the ▲/▼ keys and place the cursor (►) alongside “User Manage”. Press the OK key.
Scroll with the ▲/▼ keys and place the cursor (►) alongside “Enroll Admin”. Press the OK key.
Scroll with the ▲/▼ keys and place the cursor (►) alongside “Enroll FP”. Press the OK key.
Press OK to accept the default User ID, or manually enter a preferred User ID and press OK.
Remove Enrolled User
Press the Menu key to begin;
Scroll with the ▲/▼ keys and place the cursor (►) alongside “User Manage”. Press the OK key.
Scroll with the ▲/▼ keys and place the cursor (►) alongside “Delete”. Press the OK key.
The TF1700 will prompt you to confirm you wish to delete the fingerprint. Press OK
The TF1700 will prompt you to confirm you wish to delete the User. Press OK
The TF1700 will prompt you to confirm you wish to delete the User again. Press OK
Set Communications Options:
Press the Menu key to begin;
Scroll with the ▲/▼ keys and place the cursor (►) alongside “Options”. Press the OK key.
Scroll with the ▲/▼ keys and place the cursor (►) alongside “Comm Opt”. Press the OK key.
Available communication options will display;
Baud Rate
Device number
Net Speed
IP address
201 Circle Drive N, Suite 116 Piscataway, NJ 08854 Tel: 732-412-6007 Fax: 732-412-6008
www.zkaccess.com
Net Mask
Gateway
Scroll with the ▲/▼ keys and place the cursor (►) alongside the desired Comm option. Press OK.
Enter additional communication settings, each time pressing OK to accept.
Note:
Set the Dev num as 1
If you have more than one terminal being installed, make sure each terminal has a unique device
number.
Set the IP addr for the TF1700 if you are using TCP/IP connectivity.
Record the IP address of each TF1700 you have installed.
These IP addresses are used to identify the TF1700s.
If using the Serial communication then match the TF1700’s Baud Rate with the serial port of the
computer.
201 Circle Drive N, Suite 116 Piscataway, NJ 08854 Tel: 732-412-6007 Fax: 732-412-6008
www.zkaccess.com