Access Control Color Screen RFID Series
Product Installation Guide
Version: 1.1 Date: Jan. 2014
This d ev ic e wo rks stand al on e or n etworke d. Z K
Note:
requ ir ed f or n etwordk ed m an agement.
1. Equipment installation
Mounting Paper(only for your reference)
Cable hole
Basel ine
1.1M recomme nded he ight
from the groun d can be
adjusted acc ordin g to the
staff height .
(1) Paste the mounting template on
the wall. Drill the holes according
to the marks on the template
(holes for screws and wiring).
(4) Fix the back plate on the wall
according to the mounting paper.
(2) Remove the screws on
(3) Take away the back plate.
the bottom of device.
(5) Place the unit onto the mounting bracket, and
tighten the screws at the bottom of the unit.
Acce ss 3. 5 software is
2. Structure and Function
Access Control System Function
(1) If a registered user verified, the device will trigger
the lock control relay to open the door.
④
(2) The door sensor will detect the ON-OFF state. If
Exi t
the door is unexpectedly opened or improperly closed,
the alarm relay will be triggered.
①
Lock Sensor
TCP/IP
⑤
②
Exit Switch
(3) If the d llegal removed, the alarm relay evice is i ly
will be triggered.
(4) is External exit button supported.
③
Alarm
(5) Supports communication TCP/IP to be able to connect
with a PC. One PC can manage multiple devices.
3.Lock Connection
(1) The system supports NO lock and NC lock. For example the NO lock (normally open at power on)
is connected with "NO" and "COM" terminals, and the NC lock is connected with "NC" and
"COM" terminals.
(2) When the electrical lock is connected to the Access Control System, you need to connect one FR107 diode
(shipped in package) in parallel with the connection to prevent self-inductance EMF feedback
1
the system. NB: Do not reverse the polarities!
WARNING: Do Not operate with Power connected.
!
1) Share power with the lock:
+
-
DC12V
NC LOCK
+
-
-
+
FR 107
+12V
GND
SEN
GND
BUT
NO1
COM1
NC1
NO2
COM2
NO LOCK
DC12V
+
-
-
+
+12V
GND
SEN
GND
+
BUT
FR 107
NO1
-
COM1
NC1
NO2
COM2
Device share power with the lock:
U =12V, I-ILOCK 1A...... And the distance between the lock and theLOCK > 1) device is ≤10 meters.;
2) Does not share power with the lock:
DC12V
DC Power
NC LOCK
+
-
+
-
-
FR 107
+
+12V
GND
SEN
GND
BUT
NO1
COM1
+
NC1
NO2
-
COM2
NO LOCK
DC Power
DC12V
+
-
+
-
+
-
+
FR 107
+12V
GND
SEN
GND
BUT
NO1
COM1
NC1
NO2
COM2
Device does not share power with the lock:
A. U =12V, I-ILOCK 1A he distance between the lock and theLOCK ≤ ; B. ULOCK≠12V; C. T device is >10 meters.
D. We suggest user does not share power with the lock.
1): ‘‘I’: device output current, ‘ ’: lock voltage, ’: lock current.ULOCK ILOCK
2
3
4. Other Connections
SEN
GND
BUT
NO1
COM1
NC1
NO2
COM2
Exit Button
Alarm Power
-
+
Exi t
Alarm
Door Sensor
5. Power Connection
5. Power Connection:
The device working voltage DC 12V, electric
current 500mA (50mA for standby current).
Positive is negative is connected with‘+12V’;
‘GND’ connect with (do not reverse the polarities).
+
-
DC12V
+12V
GND
Alarm Voltage output ≤ DC 12V
6. Wiegand Output
The device supports standard Wiegand
26-bit output, so you can connect it with
various access control devices.
Access Control Panel
+12V
GND
GND
IND0
IND1
DATA0
WD0
DATA1
WD1
(1) Don’t exceed 90m (meters) distance between the Device and Access Control Lock or Card Reader.
Access Control Device
7. Wiegand Input
The device has a Wiegand input port, which enables the
connection to a slave card reader. Devices are control
devices on both sides of the door to control the access
and electric lock.
+12V
+12V
GND
GND
DATA0
IND0
DATA1
IND1
WD0
WD1
Access Control Device
Reader
(In the case of long distance installation, use the Wiegand Signal Extender, to minimise interference.)
(2) To keep a balanced and stable Wiegand signal, connect the device, access control lock or card
reader on the same “GND” (ground) port.
8. Other Functions & Features
(1) Manual Reset:
If the device does not work properly because of
misoperation or ot he r ab no rm al it y, you can use
‘Reset’ fun ct io n to r es ta rt i t.
Operation: Remove the black rubber cap, then
stick the Reset button hole with a sharp tool
(the tip diameter is less than 2mm).
(2)Tam pe r Alarm Function:
If the device is being illegally removed, the button
loses connectivity and will trigger the alarm.
9. Communication
TCP/IP Mode:
Two ways for TCP/IP connection.
(A) Crossover cable: The device and PC
connected directly.
IP Address:192.168.1.201
Subnet Mask:255.255.255.0
4
Reset Button
Straight cable: The device and PC connected
(B)
LAN/WAN through switch/Lanswitch.
to
IP Address:192.168.1.124
Subnet Mask:255.255.255.0
Side View
Reset
Back View
Tamper Button
…
Switch
WARNING: Do Not operate with Power connected.
!
10. Caution
(1) Connect the power cable after all the wiring has been completed. If the device is
working abnormally, pl ea se s hu t do wn t he d ev ic e, a nd m ak e ne ce ss ar y ch ec ks . Pl ea se
note that any "HOT SW OP " of w ir in g on t he d ev ic e ma y da ma ge t he d ev ic e, a nd t he
warranty does not cover damage caused by improper operations.
(2) We re co mm en d us e th e DC 1 2V /3 A pow er s up pl y. Pl ea se c on ta ct o ur t ec hn ic al s ta ff
for details.
(3) Please read the terminal and wiring description and diagrams carefully before
commencing with installations. Any damage to the device caused by improper
operations, will not be covered under warranty.
(4) Keep the exposed part of wire less than 5mm, to avoid unexpected connection.
(5) Please connect the 'GND' when starting installations, especially in an environment
where static electricity is very high.
(6) Do not change the cable type in case of a long distance installations.
* Reserves the final rights of modification and interpretation.