RVZC30T2 & RVZC30T2BB Specications
Low Temp Tall Reach-Ins with 72" Doors
Note: Effective 1/1/12, all Zero Zone display cases manufactured for
shipment within the U.S. meet or exceed current DOE energy requirements.
ENERGY DATA
Refrigeration
(see note #1 for components included in baseline Btuh)
Evaporator Temperature (°F)
Baseline Btuh
Discharge Air Temp. (°F) (with 8°F Superheat)
1, 2, 3
LINEUP DATA INDIVIDUAL CASE DATA (Includes 1 Pair of End Panels)
Per Door Avg. 2-Door 3-Door 4-Door 5-Door
F.F. I.C. F.F. I.C. F.F. I.C. F.F. I.C. F.F. I.C.
-7 -16 -7 -16 -7 -16 -7 -16 -7 -16
1,025 1,105 2,420 2,630 3,420 3,700 4,400 4,770 5,370 5,820
-3 -12 -3 -12 -3 -12 -3 -12 -3 -12
Btuh Deducts Btuh
Back-To-Back (Model BB)
No-Energy Doors
-80 -90
-70 -70
Btuh Adders Btuh
Permanent Split Capacitor (PSC)**
T-8 Electronic Lighting**
Standard-Energy Doors**
ELM w/ Heated Glass
Optional Glass-Windowed End Panel - Each
Fan Motors (115V)
4, 5
High Efciency Electronic (SSC/ECM)
Permanent Split Capacitor (PSC)**
Lighting System (120V) (consult factory for other LED options)
LED Lighting (Anthony OptiMax Pro24) Low Power
LED Lighting (Polaris)
T-8 Electronic Lighting**
40 40
120 120
210 220
60 63
900 1,000
Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts
0.30 23 0.60 46 0.90 69 1.20 92 1.50 115
0.26 37 0.52 74 0.78 111 1.04 148 1.30 185
Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts
0.15 18 0.30 36 0.45 54 0.60 72 0.75 90
0.20 24 0.40 48 0.60 72 0.80 96 1.00 120
0.58 70 1.45 174 1.94 233 2.42 290 2.91 349
Anti-Sweat Door Heaters (115V) Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts
Anthony 101 (Standard-Energy Doors)**
Anthony ELM w/ Heated Glass
Anthony ELM (Low-Energy Doors)
Anthony ELM II (No-Energy Doors)
2
2
2
Gemtron Polar (Standard-Energy Doors)**
Gemtron Polar LE (Low-Energy Doors)
2
2
2
1.78 205 3.67 423 5.50 633 7.28 838 9.06 1,042
1.19 138 2.49 287 3.73 429 4.92 566 6.11 703
1.00 115 2.11 243 3.16 364 4.16 479 5.16 594
0.83 96 1.88 217 2.73 314 3.48 401 4.29 494
1.86 214 3.79 435 5.68 653 7.48 860 9.30 1,069
1.38 159 2.83 325 4.24 487 5.56 639 6.90 793
Defrost Heaters (208V) Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts
Defrost Heater
6
4.00 832 8.00 1,664 12.00 2,496 16.00 3,328 20.00 4,160
** Not available in the U.S. market for equipment manufactured after December 31, 2011.
Notes:
1. Baseline Evaporator Btuh based on parallel rack system, LED lighting (Optimax Pro24 Low Power or Polaris), low-energy doors (ELM), and SSC electronic fan motors.
2. Door Options: Standard-Energy and ELM w/ Heated Glass = heated glass and rails; Low-Energy = no-heat glass and heated rails; No-Energy = no-heat glass and no-heat rails. All options have frame heat.
3. For condensing units (non-rack system), multiply total Btuh rating by 1.06.
4. Amps are based on electrical nameplate values, watts are based on laboratory observations of actual energy use.
5. One fan motor per door.
6. Electric Defrost: 1 per day. 19 minutes frozen food. 28 minutes ice cream. Failsafe 45 minutes. Refer to the Installation & Operation Manual for details.
7. Hot Gas Defrost: 1 per day. 12 to 22 minutes. Failsafe 30 minutes. Refer to the Installation & Operation Manual for details.
PHYSICAL DATA
Baseline R-404A
Refrigeration Piping
Suction Line O.D. (Std. Refrig. Exit)
2 to 5-Door Suction Line O.D. (Top Refrig)
Liquid Line O.D. (Electric Defrost)
Liquid Line O.D. (Hot Gas Defrost)
Outlet
Size (in.)
7/8 2-Dr
5/8 3-Dr 1,055 2,105 44.6 81.8 89.3
3/8 5-Dr 1,800 3,595 74.0 135.7 148.0
1/2 End Panel
Number of
Doors
4-Dr 1,420 2,840 59.3 108.8 118.7
Weight (lbs.)
RVZC30T2 RVZC30T2BB
755 N/A 30.0 55.0 60.0
35 70 N/A N/A N/A
Facings (ft.2)
Case Capacity
Packout (ft.3) 22"/24" Shelves
9/27/13SS-04-G
ELECTRICAL
3 3/4" TYP.
4"
24"
DRAIN
2"
3 3/4" TYP.
BOX (TYP.)
ELECTRICAL
OPTIONAL
REFRIGERATION
EGRESS (TYP.)
2 1/2"
END
PANEL
TYP.
EITHER SIDE)
DRAIN TO
(OPTION FOR
1" PVC DRAIN
TRAP (TYP.)
(REVERSIBLE)
ELECTRICAL
BOX (TYP.)
BOX (TYP.)
RVZC30T2 & RVZC30T2BB Specications
Low Temp Tall Reach-Ins with 72" Doors
OPTIONAL
REFRIGERATION
EGRESS (TYP.)
69 1/2"
INTERIOR
HEIGHT
3 3/4" TYP.
Length
86 3/8"
HEIGHT
Drain
Dim.
3 3/4" TYP.
CASE
# of
Doors
2 62 1/8" 31 1/16"
3 92 1/2" 46 1/4"
4 123" 61 1/2"
5 153 3/8" 76 11/16"
2 1/2"
END
PANEL
TYP.
OPTIONAL TOP REFRIGERATION CONNECTION
22" OR 24"
SHELF
72"
DOOR
HEIGHT
24"
C
L
1" PVC DRAIN
TRAP (TYP.)
(REVERSIBLE)
DRAIN
(OPTION FOR
DRAIN TO
EITHER SIDE)
2"
8 1/2"
C
14"
30 1/4"
(BASE)
(DRAIN
33 3/8"
(KICKPLATE)
35 5/8"
36/5/8" (BUMPER)
(DOOR HANDLE)
37"
9/27/13
BASE
L
C
)
L
3 1/2"
HEIGHT
5 3/8"
2 1/4"
2 1/2"
FLOOR
C
TO
L
OF DRAIN
Top refrigeration connections or top electrical connections increase case height by up to 4 inches.
BB (Back-to-Back) available in 2, 3, 4, and 5-door sizes.
End Panels and Insulated Dividers = 2 1/2".
All dimensions are nominal.
Specications are subject to change without notice.
Case designed to operate in an ambient temperature of 75°F and relative humidity of 55% or lower.
Zero Zone, Inc. | 110 N Oakridge Drive | North Prairie, WI 53153-9792
Toll Free: 800-247-4496 | Fax: 262-392-6450
Zero-Zone.com
© 2013 Zero Zone, Inc.
59 5/8" (BASES)
64 1/4"
68 3/4" (KICKPLATE)
70 3/4" (BUMPER)
71 1/2" (DOOR HANDLES)
C
) (DRAIN
L