Zero Zone RVCC30T User Manual

RVCC30T & RVCC30TBB Specications
Medium Temp Tall Reach-Ins with 68” Doors
Refrigeration
LINE-UP DATA INDIVIDUAL CASE DATA (Includes 1 Pair of End Panels)
Per Door Avg 2-Dr 3-Dr 4-Dr 5-Dr
M.T. M.T. M.T. M.T. M.T.
Evaporator Temperature (°F) +28 +28 +28 +28 +28
Baseline Btuh w/ SSC Fan Motors
(see note #1 for components included in baseline Btuh)
Baseline Btuh w/ PSC Fan Motors
(see note #1 for components included in baseline Btuh)
1, 2, 3, 5
1, 2, 3, 5
690 1,600 2,240 2,900 3,540
710 1,640 2,300 2,980 3,640
Discharge Air Temp. (°F) (with 8°F Superheat) 33 33 33 33 33
Btuh Deducts Btuh
Back-To-Back (Model BB) -40
LED Lighting -75
(consult factory for other LED options)
Btuh Adders Btuh
Anthony 101NT (Low-Energy Doors) 140
Gemtron Tundra (No-Energy Doors) 120
Optional Glass-Windowed End Panel - Each 410
Glycol Data *
2-Dr 3-Dr 4-Dr 5-Dr
M.T. M.T. M.T. M.T.
Flow Rate (GPM) 0.8 1.2 1.6 2.0
Pressure Drop (PSIG) 4.2 2.6 2.3 3.5
* All glycol data based on 35% Propylene Glycol by weight, +20°F Supply Temperature, and 24°-26°F Outlet Temperature.
Fan Motors (115V)
4
Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts
High Efciency Electronic (SSC/ECM) 0.30 12 0.60 24 0.90 36 1.20 48 1.50 60
Permanent Split Capacitor (PSC) 0.20 23 0.40 46 0.60 69 0.80 92 1.00 115
Lighting System (120V/Gemtron LED @ 115V) Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts
T-8 Electronic 0.58 70 1.45 174 1.94 233 2.42 290 2.91 349
LED Lighting (5’ Anthony OptiMax 2) 0.28 37 0.57 74 0.85 111 1.13 148 1.41 185
LED Lighting (5’ Gemtron Crossre 5100)
LED Lighting (5’ GE Gen 3 Immersion) 0.24 29 0.47 58 0.73 87 0.98 116 1.19 145
(consult factory for other LED options)
4
0.58 31 1.48 62 1.95 93 2.42 124 2.89 155
Anti-Sweat Door Heaters (115V) Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts
Anthony 101NT (Low-Energy Doors)
Anthony ELM (No-Energy Doors)
Anthony ELM II (No-Energy Doors)
Gemtron Tundra (No-Energy Doors)
Notes:
1. Baseline Evaporator Btuh based on parallel rack system, T-8 lighting, Anthony ELM No-Energy Doors, and specied fan motor.
2. Door Options: Low-Energy = no-heat glass and heated rails; No-Energy = no-heat glass and no-heat rails.
3. For condensing units (non-rack system), multiply total Btuh rating by 1.08.
4. Amps are based on electrical nameplate values, watts are based on laboratory observations of actual energy use.
5. Optional glass heat is available on Anthony 101NT and Gemtron Tundra doors. Consult factory for information.
2, 5
2, 5
2, 5
2, 5
0.58 67 1.37 158 1.90 218 2.32 266 2.91 334
0.44 51 1.09 125 1.48 170 1.76 202 2.21 254
0.26 30 0.55 63 0.81 93 1.05 121 1.30 150
0.57 66 1.15 133 1.73 199 2.30 265 2.87 331
Physical Data
Weight (lbs.) Case Capacity
RVCC30T RVCC30TBB Facings (ft2)
Packout (ft3)
22”/24” Shelves
Baseline Refrigeration Piping
Outlet
Size (In.)
Number of
Doors
Suction Line O.D. (Std. Refrig. Exit) 7/8 2-Dr 720 N/A 30.0 55.0 60.0
2 or 3 Door Suction Line O.D. (Top Refrig) 3/8 3-Dr 1,000 2,000 44.6 81.8 89.3
4 or 5 Door Suction Line O.D. (Top Refrig) 1/2 4-Dr 1,350 2,700 59.3 108.8 118.7
Liquid Line O.D. 3/8 5-Dr 1,710 3,420 74.0 135.7 148.0
Solid End Panel 35 70 N/A N/A N/A
11/09/09
Specications are subject to change without notice.
Case designed to operate in an ambient temperature of 75°F and relative humidity of 55% or lower.
Zero Zone, Inc. • 110 N Oakridge Drive • North Prairie, WI 53153-9792
(800) 247-4496 • Fax (262) 392-6450
www.zero-zone.com
OPTIONAL REFRIGERATION EGRESS (TYP.)
3 3/4" TYP.
RVCC30T & RVCC30TBB Specications
Medium Temp Tall Reach-Ins with 68” Doors
ELECTRICAL BOX (TYP.)
Doors Length Drain Dim.
2-Dr 62 1/8” 31 1/16”
3-Dr 92 1/2” 46 1/4”
4-Dr 123” 61 1/2”
5-Dr 153 3/8” 76 11/16”
2 /12"
END
PANEL
TYP.
4"
3 3/4" TYP.
24"
C
L
1" PVC DRAIN TRAP (TYP.) (REVERSIBLE)
DRAIN
(OPTION FOR DRAIN TO EITHER SIDE)
2"
69 1/2"
INTERIOR
HEIGHT
14"
30 1/4"
(DRAIN
33 3/8"
(KICKPLATE)
35 5/8"
36 5/8"
(BUMPER)
(DOOR HANDLE)
37"
OPTIONAL TOP REFRIGERATION CONNECTION
22" OR 24"
SHELF
68"
DOOR
86 3/8"
86 3/8"
C
L
8 1/2"
(BASE) 5 3/8"
C
)
L
3 1/2"
HEIGHT
2 1/4"
HEIGHT
BASE
CASE
CASE
HEIGHT
HEIGHT
2 1/2"
FLOOR
C
TO
L
OF DRAIN
59 5/8"
(BASES)
64 1/4" (DRAIN
(KICKPLATE)
68 3/4"
(BUMPER)
70 3/4"
(DOOR HANDLES)71 1/2"
C
)
L
Top refrigeration connections or top electrical connections increase case height by up to 4 inches.
BB available in 2, 3, 4, and 5-door sizes.
End Panels and Insulated Dividers = 2½”.
All dimensions are nominal.
11/09/09
Specications are subject to change without notice.
Case designed to operate in an ambient temperature of 75°F and relative humidity of 55% or lower.
Zero Zone, Inc. • 110 N Oakridge Drive • North Prairie, WI 53153-9792
(800) 247-4496 • Fax (262) 392-6450
www.zero-zone.com