RMCC24 Specications
Medium Temp Reach-Ins with 24" x 63" Doors
Note: Effective 1/1/12, all Zero Zone display cases manufactured for
shipment within the U.S. meet or exceed current DOE energy requirements.
ENERGY DATA
Refrigeration
(see note #1 for components included in baseline Btuh)
Evaporator Temperature (°F)
Baseline Btuh
Discharge Air Temp. (°F) (with 8°F Superheat)
1, 2
LINEUP DATA INDIVIDUAL CASE DATA (Includes 1 Pair of End Panels)
Per Door Avg. 2-Door 3-Door
+25 +25 +25
350 920 1,320
33 33 33
Glycol Data* 2-Door 3-Door
Flow Rate (GPM)
Pressure Drop (PSIG)
* All glycol data based on 35% Propylene Glycol by weight, +20°F Supply Temperature, and 24°-26°F Outlet Temperature.
Fan Motors (115V)
High Efciency Electronic (SSC/ECM)
3, 4
Amps Watts Amps Watts Amps Watts
0.30 11 0.60 23 0.90 34
0.6 0.8
2.8 1.6
Lighting System (120V) (consult factory for other LED options) Amps Watts Amps Watts Amps Watts
LED Lighting (Anthony OptiMax Pro24) Low Power
0.15 21 0.30 41 0.45 62
Anti-Sweat Door Heaters (115V) Amps Watts Amps Watts Amps Watts
Anthony ELM (No-Energy Doors)
Notes:
1. Baseline Evaporator Btuh based on parallel rack system, LED lighting (Optimax Pro24 Low Power), no-energy doors, and SSC electronic fan motors.
2. For condensing units (non-rack system), multiply total Btuh rating by 1.08.
3. Amps are based on electrical nameplate values, watts are based on laboratory observations of actual energy use.
4. One Fan Motor Per Door.
0.25 29 0.58 67 0.81 94
PHYSICAL DATA
Baseline Refrigeration Piping
Suction Line O.D. (Std. Refrig. Exit)
2 to 3-Door Suction Line O.D. (Top Refrig)
Liquid Line O.D.
Outlet
Size (in.)
7/8 2 553 21.8 39.9
3/8 3 797 32.5 59.1
3/8 End Panel 30 N/A N/A
# of
Doors
Weight (lbs.)
Facings (ft.2) Packout (ft.3) 22" Shelves
Case Capacity
11/18/13SS-26-C
RMCC24 Specications
Medium Temp Reach-Ins with 24" x 63" Doors
ELECTRICAL
BOX (TYP)
1" PVC DRAIN TRAP
(REVERSIBLE)
OPTIONAL TOP
REFRIGERATION
CONNECTION
64 1/2"
INTERIOR
HEIGHT
3 3/4"
4"
22" SHELF
21" BASKET
OPTIONAL
REFRIGERATION
EGRESS TYP
DRAIN
PANELS TYP
# of
Length
Doors
2 48 5/8" 24 3/8"
3 72 1/2" 36 1/4"
2 1/2" END
63"
DOOR
HEIGHT
81 3/8"
CASE
HEIGHT
Drain
Dim.
11/18/13
14"
33 3/8" (DRAIN
35 5/8" (KICKPLATE)
36 5/8" (BUMPER)
37" (DOOR HANDLE)
8"
30 1/4" (BASE)
C
L
3 1/2" BASE
2 1/2" FLOOR
C
TO
OF DRAIN
L
HEIGHT
)
Top refrigeration connections or top electrical connections increase case height by up to 4 inches.
End Panels and Insulated Dividers = 2 1/2".
All dimensions are nominal.
Specications are subject to change without notice.
Case designed to operate in an ambient temperature of 75°F and relative humidity of 55% or lower.
Zero Zone, Inc. | 110 N Oakridge Drive | North Prairie, WI 53153-9792
Toll Free: 800-247-4496 | Fax: 262-392-6450
Zero-Zone.com