Zero Zone 3RMZCWA User Manual

Note: Effective 1/1/12, U.S. Department of Energy regulations will limit certain combinations
of fan, door, and lighting choices that may be manufactured and sold in the U.S. after that date.
ENERGY DATA
Refrigeration
(see note #1 for components included in baseline Btuh)
1, 2, 4
1, 2, 4
Discharge Air Temp. (°F) (with 8°F Superheat)
Btuh Deducts Btuh
LED Lighting (Anthony Optimax 2)
Btuh Adders Btuh
Standard-Energy Doors**
Fan Motors (115V)
4
High Efciency Electronic (SSC/ECM)
Permanent Split Capacitor (PSC)
Lighting System (120V) (consult factory for other LED options) Amps Watts
LED Lighting (Anthony OptiMax 2) T-8 Electronic Lighting**
Anti-Sweat Door Heaters (115V) Amps Watts
Anthony 101 (Standard-Energy Doors)** Anthony ELM (Low-Energy Doors)
2
2
Defrost Heaters (208V) Amps Watts
Defrost Heater
CASE DATA
F.F. I.C.
-11 -18
4,070 4,420
4,175 4,525
-5 -12
-560 -560
600 630
Amps Watts
0.90 36
0.60 67
0.84 111
3.00 360
6.08 699
4.11 473
8.41 1,750
3RMZCWA Specications
Low Temp Wrap-Around Reach-Ins with 63” Doors
** Not available in the U.S. market for equipment manufactured after December 31, 2011.
Notes:
1. Baseline Evaporator Btuh based on parallel rack system, T-8 lighting, low-energy doors, and specied fan motor.
2. Door Options: Standard-Energy = heated glass and rails; Low-Energy = no-heat glass and heated rails.
3. For condensing units (non-rack system), multiply total Btuh rating by 1.08.
4. Amps are based on electrical nameplate values, watts are based on laboratory observations of actual energy use.
PHYSICAL DATA
Baseline R-404A Refrigeration Piping
Suction Line O.D. (Std. Refrig. Exit) Liquid Line O.D. (Electric Defrost) Liquid Line O.D. (Hot Gas Defrost)
Outlet Size (in.)
7/8 or 5/8 for Ref Out Top 920 38.0 39.0
3/8
1/2
Weight (lbs.) Case Capacity
3RMZCWA
Facings (ft.2) Packout (ft.3)
10/4/11SS-14-A
3RMZCWA Specications
Low Temp Wrap-Around Reach-Ins with 63” Doors
10/4/11
 Top refrigeration connections or top electrical connections increase case height by up to 4 inches.  3½” bases standard. 4½” bases available; increases exterior height by 1”.  All dimensions are nominal.
Specications are subject to change without notice. Case designed to operate in an ambient temperature of 75°F and relative humidity of 55% or lower.
Zero Zone, Inc. | 110 N Oakridge Drive | North Prairie, WI 53153-9792
Toll Free: 800-247-4496 | Fax: 262-392-6450
Zero-Zone.com
Loading...