Hybrid™ Specications
Medium and Low Temp Hybrid Reach-Ins: RVCC30 & RVZC30
Note: Effective 1/1/12, all Zero Zone display cases manufactured for
shipment within the U.S. meet or exceed current DOE energy requirements.
PHYSICAL DATA
Medium Temp Low Temp
2RVCC30 3RVCC30 4RVCC30 5RVCC30 2RVZC30 3RVZC30 4RVZC30 5RVZC30
Facings (ft.2)
Packout (ft.3)
Shelf Depth (in.)
Weight (lbs.)*
* Does not include weight of condensing unit. Weights include 2 end panels at 54 lbs. per pair.
ELECTRICAL DATA
MOCP (amps)
3
1, 2
MCA (amps)
27.8 41.4 55.1 68.7 27.8 41.4 55.1 68.7
51 76 101 126 51 76 101 126
22 22 22 22 22 22 22 22
783 1,033 1,343 1,683 783 1,033 1,343 1,683
OptiMax Pro24 LED Lighting, Anthony ELM / ELM-HG Doors, SSC Fan Motors w/ Cond Evap System
15 15 15 15 30 30 30 45
8.7 9.6 12.2 14.0 22.3 22.5 27.0 34.9
ENERGY DATA
Daily Energy Use (kWh)
Rejected Heat (Btuh)
4
12.8 18.1 22.1 24.8 28.8 39.9 52.9 63.0
1,819 2,575 3,148 3,528 4,089 5,673 7,524 8,959
R-404A CHARGE
R-404A Charge (lbs.)
5
5.0 5.0 6.1 7.8 5.9 5.9 7.4 9.0
REFRIGERATION
ZZ Condensing Unit No.
Crated Weight (lbs.)
ELECTRICAL DATA
MOCP (amps)
MCA (amps)
3
1, 2
9481 9481 9483 9485 9598 9598 9598 9599
100 100 100 120 180 180 180 260
OptiMax Pro24 LED Lighting, Anthony ELM / ELM-HG Doors, SSC Fan Motors w/o Cond Evap System
15 15 15 15 30 30 30 45
8.3 8.3 11.2 13.0 19.6 20.8 22.9 34.9
4
4
ENERGY DATA
Daily Energy Use (kWh)
Rejected Heat (Btuh)
4
12.6 17.8 21.7 24.3 28.4 39.3 52.1 62.0
1,790 2,532 3,091 3,456 4,032 5,587 7,410 8,817
R-404A CHARGE
R-404A Charge (lbs.)
5
5.0 5.0 6.1 7.8 5.9 5.9 7.4 9.0
REFRIGERATION
ZZ Condensing Unit No.
Crated Weight (lbs.)
Notes:
1. 208V 4-wire service; 115/208V-1PH-60HZ; red & black power, white neutral, green ground.
Buck/boost transformer available for low voltage conditions.
2. Main service disconnect is not provided.
3. MOCP = Maximum over-current protection.
4. Adequate ventilation must be provided to dissipate rejected heat from the top of the unit
for proper performance. Clearance of less than 30" above the top of the shroud to the ceiling
requires special design considerations. See Zero Zone Hybrid Installation and Operation Manual
for specic details.
5. Refrigerant charge includes combined condensing unit and case charges.
6. See separate reach-in case spec sheets for additional details: RVCC30, RVZC30.
9481 9481 9483 9485 9598 9598 9598 9599
100 100 100 120 180 180 180 260
Factory Installed Hybrid™ Features:
Refrigeration piping with quick connect couplings and refrigerant charge.
Pre-wired and labeled for easy connection.
Electronic control includes: time clock, temperature and defrost control, visual and audible
temperature alarm, and network communication capability.
Field Installed Hybrid™ Features:
20 1/4" tall aluminum shroud (front and sides standard, rear optional). Consult factory for other
options.
Condensing unit with quick connect threaded couplings.
Condensate collection and removal system: collection pan, pump, oat switch, condensate dis-
sipation pan with heater element, and connecting tubing.
1 3/4" hat channels to raise case to proper operating height.
11/1/13SS-09-F
# of
Doors
2 62 1/8"
3 92 1/2"
4 123"
5 153 3/8"
Hybrid™ Specications
Medium and Low Temp Hybrid Reach-Ins: RVCC30 & RVZC30
Length
11/1/13
Specications are subject to change without notice.
Case designed to operate in an ambient temperature of 75°F and relative humidity of 55% or lower.
Zero Zone, Inc. | 110 N Oakridge Drive | North Prairie, WI 53153-9792
Toll Free: 800-247-4496 | Fax: 262-392-6450
Zero-Zone.com