Zero Zone 2RVCC30 User Manual

RVCC30 & RVCC30BB Specications
Medium Temp Reach-Ins with 63" Doors
Note: Effective 1/1/12, all Zero Zone display cases manufactured for
shipment within the U.S. meet or exceed current DOE energy requirements.
ENERGY DATA
Refrigeration
(see note #1 for components included in baseline Btuh)
Evaporator Temperature (°F) Baseline Btuh Discharge Air Temp. (°F) (with 8°F Superheat)
1, 2, 3
LINEUP DATA INDIVIDUAL CASE DATA (Includes 1 Pair of End Panels)
Per Door Avg. 2-Door 3-Door 4-Door 5-Door
RVCC30 2RVCC30 3RVCC30 4RVCC30 5RVCC30
+28 +28 +28 +28 +28
540 1,420 2,040 2,680 3,280
33 33 33 33 33
Btuh Deducts Btuh
Back-To-Back (Model BB)
-40
Btuh Adders Btuh
Permanent Split Capacitor (PSC)** T-8 Electronic Lighting** Anthony ELM or Gemtron Tundra (No-Energy Doors) Anthony 101NT (Low-Energy Doors) Optional Glass-Windowed End Panel - Each
30
120
70
140
410
Glycol Data* 2-Door 3-Door 4-Door 5-Door
Flow Rate (GPM) Pressure Drop (PSIG)
* All glycol data based on 35% Propylene Glycol by weight, +20°F Supply Temperature, and 24°-26°F Outlet Temperature.
Fan Motors (115V)
High Efciency Electronic (SSC/ECM)
Permanent Split Capacitor (PSC)**
Lighting System (120V) (consult factory for other LED options)
LED Lighting (Anthony OptiMax Pro24) Low Power LED Lighting (Polaris) T-8 Electronic Lighting**
4, 5
Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts
0.30 11 0.60 22 0.90 33 1.20 44 1.50 55
0.20 23 0.40 46 0.60 69 0.80 92 1.00 115
Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts
0.15 18 0.30 36 0.45 54 0.60 72 0.75 90
0.17 20 0.33 40 0.50 60 0.67 80 0.83 100
0.58 70 1.45 174 1.94 233 2.42 290 2.91 349
0.8 1.2 1.6 2.0
4.2 2.6 2.3 3.5
Anti-Sweat Door Heaters (115V) Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts
Anthony 101NT (Low-Energy Doors) Anthony ELM (No-Energy Doors)
2
Anthony ELM II (No-Energy Doors) Gemtron Tundra (No-Energy Doors)
2, 6
2
2, 6
0.47 55 1.22 141 1.65 190 2.11 243 2.60 299
0.35 41 0.98 113 1.29 149 1.63 188 2.00 230
0.23 27 0.53 61 0.75 87 1.00 115 1.24 143
0.43 50 0.86 100 1.30 150 1.74 201 2.17 250
** Not available in the U.S. market for equipment manufactured after December 31, 2011.
Notes:
1. Baseline Evaporator Btuh based on parallel rack system, LED lighting (Optimax Pro24 Low Power or Polaris), no-energy doors (ELM II), and SSC electronic fan motors.
2. Door Options: Low-Energy = no-heat glass and heated rails; No-Energy = no-heat glass and no-heat rails. All options have frame heat.
3. For condensing units (non-rack system), multiply total Btuh rating by 1.08.
4. Amps are based on electrical nameplate values, watts are based on laboratory observations of actual energy use.
5. One Fan Motor Per Door.
6. **Optional glass heat is available on Anthony 101NT and Gemtron Tundra doors. Consult factory for information.
PHYSICAL DATA
Baseline Refrigeration Piping
Suction Line O.D. (Std. Refrig. Exit) 2-Door Suction Line O.D. (Top Refrig) 3 to 5-Door Suction Line O.D. (Top Refrig) 2-Door Liquid Line O.D. 3 to 5-Door Liquid Line O.D.
Outlet
Size (in.)
1/2 2 675 1,350 27.8 51.0 55.6
3/8 3 925 1,850 41.4 76.0 82.9
1/2 4 1,235 2,475 55.1 101.0 110.1
1/4 5 1,575 3,150 68.7 125.9 137.4
3/8 End Panel 30 60 N/A N/A N/A
Number of
Doors
Weight (lbs.)
RVCC30 RVCC30BB
Facings (ft.2)
Case Capacity Packout (ft.3) 22"/24" Shelves
8/20/13SS-01-G
ELECTRICAL
37" (DOOR HANDLE)
BOX (TYP.)
RVCC30 & RVCC30BB Specications
Medium Temp Reach-Ins with 63" Doors
OPTIONAL REFRIGERATION EGRESS (TYP.)
3 3/4" TYP.
64 1/2"
INTERIOR
HEIGHT
# of
Length
Doors
2 62 1/8" 31 1/16"
3 92 1/2" 46 1/4"
4 123" 61 1/2"
5 153 3/8" 76 11/16"
2 1/2"
END
PANEL
TYP.
4"
OPTIONAL TOP REFRIGERATION CONNECTION
22" OR 24"
SHELF
81 3/8"
CASE
HEIGHT
63"
DOOR
HEIGHT
Drain
Dim.
3 3/4" TYP.
24"
C
L
1" PVC DRAIN TRAP (TYP.) (REVERSIBLE)
DRAIN
(OPTION FOR DRAIN TO EITHER SIDE)
2"
14"
30 1/4"
33 3/8"
35 5/8"
36 5/8"
8/20/13
8 1/2"
(BASE)
C
(DRAIN)
(KICKPLATE)
(BUMPER)
2 1/2"
FLOOR
C
TO
3 1/2"
C
L
)
L
BASE
HEIGHT
5 3/8"
2 1/4"
L
OF DRAIN
59 5/8"
64 1/4"
68 3/4"
70 3/4"
71 1/2" (DOOR HANDLES)
 Top refrigeration connections or top electrical connections increase case height by up to 4 inches.  BB (Back-to-Back) available in 2, 3, 4, and 5-door sizes. End Panels and Insulated Dividers = 2 1/2".  All dimensions are nominal.
Specications are subject to change without notice.
Case designed to operate in an ambient temperature of 75°F and relative humidity of 55% or lower.
Zero Zone, Inc. | 110 N Oakridge Drive | North Prairie, WI 53153-9792
Toll Free: 800-247-4496 | Fax: 262-392-6450
Zero-Zone.com
© 2013 Zero Zone, Inc.
(BASES)
C
(DRAIN)
(KICKPLATE)
(BUMPER)
L
Loading...