LEVEL PLUS MK2 USER INSTRUCTIONS
If a portable or temporary three phase mains supply is used to power
this desk, we recommend that the power supply unit is unplugged
from the mains supply before connecting or disconnecting the mai
supply.
SERIOUS DAMAGE will occur if the power supply is connected
across two phases.
Zero88 Lighting Ltd, Usk House, Llantarnam Park, Cwmbran, Gwent NP44 3HD, U.K
73-712-00 Email: sales@zero88.com
IM7772 LevelPlusMk2 Manual Issue 1.0b www.zero88.com Page 1 of 3
Tel: +44 (0) 1633 838088 (24hr Answer Phone) Fax: +44 (0) 1633 867880

LEVEL PLUS MK2 USER INSTRUCTIONS
The Level Plus Mk2
The Level Plus Mk2 Lighting desk is a two preset 12
channel desk with fade time control, and the ability to
flash individual channels. All crossfades are dipless.
The multiple brightness sources (A preset, B preset,
Flash buttons and Sequence) are all mixed HTP
(Highest Takes Precedence).
A wide mode feature allows 24 channel operation,
with an internal scene store for stored preset
operation. A sequence feature allows programming of
a chase, and can also be used as a playback stack.
Output is DMX only (channels 1-24), no analogue
output options are available.
Controls and Displays
PRESETS A AND B
The PRESET A faders control the output levels of the
individual channels in association with the A
MASTER and GRAND MASTER faders (see below).
When in wide mode, these control channels 1-12.
The PRESET B faders control the output levels of the
individual channels in association with the B
MASTER and GRAND MASTER faders (see below).
When in wide mode, these control channels 13-24.
CHANNEL FLASH BUTTONS
When the LED in the FLASH ON/OFF button is
steady, the CHANNEL FLASH buttons are used to
flash the channels 1-12 to the level of the GRAND
MASTER. When the LED in the FLASH ON/OFF
button is blinking (option only available when the
desk is in wide mode), the CHANNEL FLASH buttons
are used to flash the channels 13-24 to the level of
the GRAND MASTER. When the LED in the FLASH
ON/OFF button is off, these buttons have no effect.
A MASTER AND B MASTER FADERS
The A MASTER is used to control the maximum
output level from the PRESET A faders. In wide
mode, this fader controls the maximum output level
from all 24 channel faders.
The B MASTER is used to control the maximum
output level from the PRESET B faders. In wide
mode, this fader is not used.
The B MASTER fader is reversed (100% at the
bottom of its travel) to facilitate crossfades when
moving the A MASTER and B MASTER in tandem
(i.e. in the same physical direction).
FADE TIME CONTROL
Crossfading between the preset scene and the stored
scene in Wide Mode works in the same way as
crossfading between presets A and B in Two Preset
mode. The control can be set to a value between
zero (manual) and the maximum fade time shown on
the front panel.
The FADE TIME control is also used to determine the
crossfade time between sequence steps when the
sequence is manually advanced using the
SEQUENCE button.
SEQUENCE MASTER FADER
The SEQUENCE MASTER fader is used to control
the maximum output level from the sequence.
SEQUENCE SPEED CONTROL
The SEQUENCE SPEED control determines the
speed at which the sequence is advanced on
playback. When in manual mode, the sequence is
only advanced when the SEQUENCE button is
pressed.
SEQUENCE BUTTON
The SEQUENCE Button has several functions
depending on the mode:
1. LED off – sequence is not being output. Tap the
button to start the sequence. Hold the button for
2s to enter sequence programming mode.
2. LED blinking – sequence is being output. Tap
the button to advance the sequence. Hold the
button for 2s to stop the sequence.
3. LED on – programming mode. Tap the button to
program a step. Hold the button for 2s to exit
programming mode.
GRAND MASTER FADER
The GRAND MASTER fader is used for overall
control of the maximum output levels from all
channels of the desk.
FLASH ON/OFF BUTTON
The FLASH ON/OFF button is used to set the
CHANNEL FLASH buttons to channels 1-12, 13-24
(wide mode only), or disabled. See above for further
description.
WIDE MODE BUTTON
The WIDE MODE button is used to set the desk into
two preset 12 channel operation, or stored preset 24
channel operation. The LED in the button will light to
indicate Wide Mode. The playback of sequences is
not affected by Wide Mode.
PRESET CONTROL BUTTON
This button is only active when the desk is in Wide
Mode. The PRESET CONTROL button and the
accompanying LEDs on the front panel are used to
control and indicate which master (A Master or B
Master) has control of the preset channel faders, and
which master has control of the ‘stored’ scene.
In Wide Mode the user is able to crossfade between,
or combine two full width scenes, 24 channels wide.
A scene is set up using the Preset A and Preset B
faders to set all 24 channel levels, and then stored in
memory by pressing the PRESET CONTROL button.
A second scene can then be set up on the Preset A
and Preset B faders. The A Master and B Master
faders can then be used to crossfade between the
two scenes.
Zero88 Lighting Ltd, Usk House, Llantarnam Park, Cwmbran, Gwent NP44 3HD, U.K
73-712-00 Email: sales@zero88.com
IM7772 LevelPlusMk2 Manual Issue 1.0b www.zero88.com Page 2 of 3
Tel: +44 (0) 1633 838088 (24hr Answer Phone) Fax: +44 (0) 1633 867880

LEVEL PLUS MK2 USER INSTRUCTIONS
Technical Specification
External Power Supply
The Level Plus Mk2 requires an external in-line
power supply.
Mains voltage 100-240V, 50-60Hz (CEE22 inlet)
4 pin ring locking DIN connector to desk:
Pin 1/3 +12V DC @ 300mA
Pin 2 0V
Pin 4 not used
External Power Supply Connector.
Viewed from the rear of the desk.
DMX Output
5 pin female XLR, unisolated, with voltage protection.
Data on DMX channels 1-24 only.
Pin 1 0V Signal ground
Pin 2 DMX drive B / -ve / complement
Pin 3 DMX drive A / +ve / true
Pin 4/5 Not connected
DMX Connector.
Viewed from the rear of the desk.
Notes:
Zero 88 Lighting Ltd reserves the right to make
changes to the equipment described in this manual
without prior notice.
This equipment is designed for professional stage
lighting control, and is unsuitable for any other
purpose.
It should be used by, or under the supervision of, an
appropriately qualified or trained person.
E&OE. Zero88 Lighting Ltd reserves the right to
change the specification without prior notice.
Manual Stock Number: 7371200
Issue 1.0: October 2004
© Zero 88 Lighting Ltd 2004
Zero88 Lighting Ltd, Usk House, Llantarnam Park, Cwmbran, Gwent NP44 3HD, U.K
Tel: +44 (0) 1633 838088 (24hr Answer Phone) Fax: +44 (0) 1633 867880
73-712-00 Email: sales@zero88.com
IM7772 LevelPlusMk2 Manual Issue 1.0b www.zero88.com Page 3 of 3