USE, CARE, AND INSTALLATION GUIDE
Read all Instructions before Installing and operating this appliance
MODELS: ZPY-E30 (B,W,S), ZPY-E36 (B,W,S) Pyramid
WARNING
Installation
The installation in this manual is intended for qualified installers,service technicians or persons
with similar qualified background.DO NOT attempt to install this appliance yourself.Injury could
result from installing the unit due to lack of appropriate electrical and technical background.
All electrical wiring must be properly installed, insulated and grounded. Overly accumulated
grease in old duct work should be cleaned out or duct work should be replaced if necessary to
avoid the possibility of a grease fire. Check all joints on duct work to insure proper connection
and all joints should be properly taped.
Operations
Read all instructions in this manual before operating the appliance. Sa ve these instructions for
future reference.
Always leave safety grills and filters in place. Without these components, operating blowers
could catch on to hair, fingers and loose clothing.
NEVER dispose cigarette ashes, ignitable substances, or any foreign objects into blowers.
NEVER leave cooking unattended.When frying,oil in the pan can easily overheat and catch fire.
The risk of self combustion is higher when the oil has been used several times.
Cleaning
The saturation of greasy residue in the blower and filters may cause increased inflammability.
Keep unit clean and free of grease and residue build-up at all times to prevent possible fires.
Filters must be cleaned periodically and free from accumulation of cooking residue (see cleaning instructions inside). Old and worn filters must be replaced immediately. Do not operated
blowers when filters are removed.Never disassemble parts to clean without proper instructions.
Disassembly is recommended to be performed by qualified personnel only .Call our service cen-
ter for removal instructions.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and the warranty of the
unit automatically expires due to improper maintenance.
IMPORTANT SAFETY NOTICE
* Please check for latest specification revisions before any custom work or cutouts.

CONTENTS
INSTALLATION
Mount heights & clearance
Ducting
Specifications
Mounting the hood & electrical
FEATURES & CONTROLS
Controls & features
MAINTENANCE
Cleaning
Lights replacement
WARRANTY
Coverage & exceptions
1
1,2
3
4-7
8
9
10
11

INSTALLATION
1
MOUNT HEIGHTS
DUCTING
6-3/4"
36"
96"
Min 24"-Max 32"
Minimum mount height between range top to
hood bottom should be no less than 24".
Maximum mount height should be no higher
than 32".
It is important to install the hood at the
proper mounting height. Hoods mounted too
low could result in heat damage and fire hazard; while hoods mounted too high will be
hard to reach and will loose its performance
and efficiency.
If available, also refer range manufacturer's
height clearance requirements and recommended hood mounting height above range.
A minimum of 5" round or 3-1/4” x 10"rectangular
duct must be used to maintain maximum air flow
efficiency.
Always use rigid type metal ducts only.
Flexible ducts could restrict air flow by up to 50%.
Also use calculation (on right) to compute total
available duct run when using elbows, transitions
and caps.
ALWAYS,when possible, reduce the number or
transitions and turns. If long duct run is required,
increase duct size from 6" to 7 or 8". If a reducer
is used, install a long reducer instead of a pancake
reducer. Reduce duct size as far away from opening as possible.
If turns or transitions are required:
Install as far away from opening and as far
apart, between 2, as possible.
*Minimum clearance of 24”hood above range
height.
** Maximum clearance 32" hood above range
height.
Minimum Duct Size:
Round:
5" minimum
Rectangular:
Requires an adaptor.Readily available at most
hardware stores.
Duct Run Calculation:
Maximum run
5" or 3-1/4” x 10" duct
Deduct:
each 90 Elbow used
each 45 elbow used
each 6" to 3/14 x 10"
transition used
each 3/14 x 10" to 6"
each 3/14 x 10" to 6"
transition used
Side Wall Cap w/ damper
Roof Cap
100 FT
15 FT
9 FT
1 FT
5 FT
30 FT
30 FT
e.g.- 1 roof cap, 2x90 elbows, 1 45 elbow used:
=30' + 30' + 9' =69' used, 31' available for straight duct runs.

INSTALLATION
2
DUCTING
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,a ttics or
garages.All exhaust must be ducted to the outside.
Use Metal ductwork only.
Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or DuctTape.
Some Ducting Options:
WARNING FIRE HAZARD
side wall cap
w/ gravity damper
side wall cap
w/ gravity damper
Soffit or crawl space
Roof Pitch w/
Flashing & Cap