Guide d’utilisation, d’entretien et d’installation
JAN06.0101
READAND SAVE THESE INSTRUCTIONS
LISEZ CES INSTRUCTIONS ET CONSERVEZ-LES
LEAYGUARDE ESTAS INSTRUCCIONES
E page 2
F page22
S page43
APPROVED FOR RESIDENTIAL APPLIANCES
FOR RESIDENTIAL USE ONLY
READ AND SAVE THESE INSTRUCTIONS
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use.
INSTALLER: Please leave these Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
Safety Warning: Turn off power circuit at service panel and lock out panel, before wiring this appliance.
Requirement: 120 V AC, 60 Hz. 15 or 20 A Branch Circuit
2
Important safety Notice.....................................................................4
List of Part and Accessories............................................................ 19
Table of Contents
3
READ AND SAVE THESE INSTRUCTIONS
CAUTION:
FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR
VAPORS.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
B. Before servicing or cleaning the unit, switch power off at service panel and lock service panel disconnecting means
to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag, to the service panel.
C. Installation Work and Electrical Wiring Must Be Done By Qualified Person(s) In Accordance With All Applicable Codes
& Standards, Including Fire-rated Construction.
D. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning
equipment to prevent back- drafting. Follow the heating equipment manufacturers guideline and safety standards
such as those published by the National Fire Protection Association (NFPA), the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
E. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
F. Ducted systems must always be vented to the outdoors.
CAUTION:
To reduce risk of fire and to properly exhaust air, be sure to duct air outside - do not vent exhaust air into spaces
within walls, ceilings, attics, crawl spaces, or garages.
WARNING
Important safety Notice
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK.
Install this hood in accordance with all requirements specified.
WARNING
To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Hood With Any External Solid State Speed Control
Device.
WARNING
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE.
a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambe’).
c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for the size of the surface element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS, IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or other metal tray, then turn off the gas burner or the electric
element. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE
FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - you may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.
d) Use an extinguisher ONLY if:
1)You know you have a class ABC extinguisher, and you already know how to operate it.
2)The fire is small and contained in the area where it started.
3)The fire department is being called.
4)You can fight the fire with your back to an exit.
OPERATION
a. Always leave safety grills and filters in place. Without these components, operating blowers could catch onto hair,
fingers and loose clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to
negligence and the warranty of the unit automatically expires due to improper maintenance.
* NOTE: Please check our website for revisions before doing any custom work.
4
www.zephyronline.com
ELECTRICAL REQUIREMENTS
Important:
Observe all governing codes and ordinances.
It is the customer’s responsibility:
•To contact a qualified electrical installer.
•To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA
70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest
edition** and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure range hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
IMPORTANT:
Save Installation Instructions for electrical inspector’s use.
The range hood must be connected with copper wire only.
The range hood should be connected directly to the fused disconnect (or circuit breaker) box through metal electrical
conduit.
Wire sizes must conform to the requirements of the National Electrical Code ANSI/NFPA 70 — latest edition*, or CSA
Standards C22.1-94, Canadian Electrical Code Part 1 and C22.2 No. 0-M91 - latest edition** and all local codes and
ordinances.
A U.L.- or C.S.A.-listed conduit connector must be provided at each end of the power supply conduit (at the range hood
and at the junction box).
Copies of the standards listed may be obtained from:
* National Fire Protection Association Batterymarch Park Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575
BEFORE INSTALLING THE HOOD
1. For the most efficient air flow exhaust, use a straight run or as few elbows as possible.
CAUTION: Vent unit to outside of building, only.
2. At least two people are necessary for installation.
3. The hood is fitted with Screws and Drywall Anchors suitable for most surfaces, consult a Qualified Installer, check if
they perfectly fit with your cabinet/wall.
4. Do not use flex ducting.
5. COLD WEATHER installations should have an additional backdraft damper installed to minimize backward cold air
flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork. The
damper should be on the cold air side of the thermal break.
The break should be as close as possible to where the ducting enters the heated portion of the house.
6. Make up air: Local building codes may require the use of Make-Up Air Systems when using Ducted Ventilation
Systems greater than specified CFM of air movement.
The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your
area.
5
Electrical & Installation requirements
PARTS SUPPLIED:
•Blower unit housing
•Hood canopy
•Metal filter x 1
•Halogen light bulb x 2
•Hardware Packet:
Transition
Allen spanner x 1
Lower bracket x 2
Upper Bracket x 2
Use, Care and Installation guide
Template
Cloth
2,9x9,5 screws x 2 (to fix the transition)
List of Materials
4,5x16 screws x 4 (2 to fix the drawer to the bottom of the cabinet + 2 to fix the deflector on top of the cabinet ceiling)
5x18 screws x 4 (upper/lower brackets adjusting screws)
3,5x9,5 x 4 (for definitive fixing of upper/lower brackets.
PARTS NOT SUPPLIED
•Duct, conduit and all tools required for installation.
•Remote Control
•Ductless Recirculating Kit
to be used only in the Ductless (recirculating) version
includes: charcoal filter, charcoal filter support and fixing bracket, deflector
6
Cut out for venting
system and
conduit
www.zephyronline.com
Ductless (recirculating) version
7"
7" 3/8
1" 1/4
9" 1/16
1" 1/4
9" 1/4
7" 1/16
23" 5/16
21" 3/4
21"
13/16"
13/16"
3" 3/8
Cut out for blower unit
housing passage
10"
Dimensions and clearances
30"-36"
9" 13/16
9" 13/16
2" 3/4
15/16" - 1" 3/4
7
Closely follow the instructions set out in this manual.
All responsibility, for any eventual inconveniences, damages or fires caused by not complying with the instructions in
this manual, is declined.
VENTING METHODS
The hood is equipped with a transition B for discharge of fumes to the outside (Ducting version).
Should it not be possible to discharge cooking fumes and vapour to the outside, the hood can be used in the Ductless(recirculating) version. Attach a charcoal filter on the internal side of the metal filter and the deflector F directly on the
transition (Cabinet without ceiling) or at the top of the cabinet. Fumes and vapors are recycled directly through the
deflector F (Cabinet without ceiling) or by means of a duct connected to the transition B and the deflector F.
NOTE: For ductless (recirculating) version only: purchase the Ductless Recirculating Kit.
This hood is designed to be installed inside a cabinet (only Blower unit housing) and fixed at the bottom of the cabinet,
check that the cabinet, its bottom, the hanging system of the cabinet and the wall where cabinet is installed is strong
enough to support the hood.
The inside of the cabinet should be accessible.
However, a qualified technician must verify suitability of the materials in accordance with the type of cabinet.
We suggest to mount the cabinet onto the wall after having installed the hood.
Before making cutouts, make sure there is proper clearance.
NOTE: For ductless (recirculating) version only: Check that there is enough clearance from ceiling and deflector once
this last has been mounted to let an easy recirculation of air.
Hood installation height above cooktop is the users preference. The lower the hood above the cooktop, the more
efficient the capturing of cooking odors, grease and smoke.
The hood shall be installed at 24" minimum to 32" above the countertop.
Check your ceiling height and the hood height maximum before you select your hood.
6” Round to
3 1/4 ” x 10”
rect.
transition
90° elbow
7", 8" round
90° elbow
7", 8" round
45° elbow
7", 8" Round
wall cap
with damper
7", 8"
Round,
roof cap
7” Round to
3 1/4 ” x 10”
rect.
transition
7” Round to
3 1/4 ” x 10”
rect.
transition
90° elbow
lenght x used =Total
30 Ft. x () =
30 Ft. x () =
1 Ft.x () =
16 Ft. x () =
15 Ft. x () =
9 Ft.x () =
30 Ft. x () =
30 Ft. x () =
8 Ft.x () =
15 Ft. x () =
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Installation - Ductwork Calculation Sheet
Ft.
6 ” Round,,
45°elbow
Maximum Duct Length: For satisfactory air movement, the total
duct length should not exceed 100 equivalent feet.
9 Ft.x () =
Subtotal column 1 =
Ft.
Subtotal column 2 =
Subtotal column 2 =
Total ductwork=
9
1. If possible, disconnect and move freestanding or
slide-in range from cabinet opening to provide
easier access to rear wall. Otherwise put a thick,
protective covering over countertop, cooktop or
range to protect from damage or dirt. Select a flat
surface for assembling the unit. Cover that surface
with a protective covering and place all canopy hood
parts and hardware in it.
2. Remove the metal filter (see paragraph "Mainte-
Installation
nance") top access the inside of the range hood.
3. Perform any necessary cutout on cabinet and wall
as per "Dimensions and clearances" paragraph for
range hood mounting and for vent system and
conduit passage.
Use the supplied template to perform the cut out on
cabinet.
Tape the template on the bottom of the cabinet,
check that printed arrows match with the front edge
of the cabinet (without considering the cabinet
door).
Cut as indicated.
box.
Run wires through hole according the National
Electrical Code or CSA Standards and local
codes and ordinances.
There must be enough power supply cable
from the fused disconnect (or circuit breaker)
box to make the connection in the hood’s
Junction box/es.
Use caulking to seal all openings on wall.
Do Not turn on power until installation is
completed.
6. Fit the transition on top of the hood.
7. Regulate the rear spacer to cover the clearance
on the rear side once the hood has been
installed (see also paragraph "Dimensions
and clearances") and fix it with two screws (one
per side).
4. Install the vent system before the range hood. See
„Venting methods“ and „Dimensions and clearance“ paragraphs.
Note - for Ductless - recirculating - installations:
Purchase the Ductless recirculating kit
Cabinet without ceiling:
Vent system is not required.
Cabinet with ceiling:
A 6" section of duct may be required to connect
transition to deflector.
5. Install a conduit long enough to reach the junction
10
Spacer
Spacer
fixing
screw
A
see Dimensions
and Clearances
8. Fit the blower unit housing inside the cabinet
through the bottom opening.
Check that fixing springs goes over the bottom
panel..
www.zephyronline.com
Side fixing screws
Installation
Bottom
opening
Bottom
panel
9. Apply two brackets (one per side) to the blower unit
housing.........
Upper bracket
....... lock in place (check that each bracket , once in
position, is flush to the front side of the blower unit
housing) tighten the side fixing screws (two per
brackets) and, from the inside of the hood, fix with
one screw each then .......
Fixing
springs
Upper + lower bracket
definitive fixing screws
.......apply the two bigger brackets (lower brackets)
under the first two and....
Lower bracket
11
..... tighten securely the two screws on upper
brackets, check that blower housing is now well
blocked, then, from the inside of the hood, fix
definitively the lower brackets with one screw each.
Installation
Adjusting
screws
10. Refinish the installation to cabinet with two fixing
screws.
Final
fixing
screw
Final
fixing
screw
Upper + lower bracket
definitive fixing screws
For Ductless (recirculating) installations
Cabinet without ceiling ONLY:
Install the deflector (available as an extra kit) on the
transition - snap into place.
11. Connect ducting to transition. Seal with duct tape.
Do not use duct smaller than the transition.
For Ductless - recirculating - installations:
Cabinet with ceiling ONLY:
provide and install a section of duct long enough to
connect hood transition to deflector once this has
been installed onto the cabinet ceiling (the deflector is available as an extra kit).
12
www.zephyronline.com
12. Electrical connection
WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the service panel
before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN ELECTRICAL
JUNCTION BOX WITH 3 WIRES, ONE OF WHICH
(GREEN/YELLOW) SERVES TO GROUND THE
APPLIANCE. TO PROTECT YOU AGAINST ELECTRIC
SHOCK, THE GREEN AND YELLOW WIRE MUST BE
CONNECTED TO THE GROUNDING WIRE IN YOUR
HOME ELECTRICAL SYSTEM, AND IT MUST UNDER
NO CIRCUMSTANCES BE CUT OR REMOVED.
Failure to do so can result in death or electrical
shock.
Remove the Junction box cover and knockout and
install the conduit connector (cULUS listed) in junction
box cover.
13. For Ductless (recirculating) installations
Install one charcoal filter (available as an extra kit).
14. Check all light bulbs to make sure they are secure
in their sockets.
Turn power on in service panel.
Check lights and blower operation.
15. Install filter.
If range hood does not operate:
•Check that the circuit breaker is not tripped or the
house fuse blown.
•Disconnect power supply. Check that wiring is
correct.
Run 3 wires; black, white and green ,according to the
National Electrical Code and local codes and ordinances, in 1/2" conduit from service panel to junction
box.
Connect black wire from service panel to black or red in
junction box, white to white and green to green-yellow.
Close junction box cover.
13
1 Control panel
2 Grease filter
3 Grease filter release handle
4 Halogen lamp (position and nr. of lamps may vary)
5 Sliding Glass
6 Hood canopy
1
5
6
Description of the hood
3
4
2
14
www.zephyronline.com
Use the high suction speed in cases of concentrated kitchen vapours. It is recommended that the cooker hood suction
is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes
approximately after terminating cooking.
Description of control panel:
F
E
D
C
B
A
A- Lighting: dim lighting / full lighting /off (loop control) - Works even with hood in stand by and/or drawer closed.
B -Set Fan in Stand by (LED on the lower side of the display ON).
C -ON/OFF Timer for selected speed (visualizes the speed selected and flashing LED on the lower side of the
display).
This knob permits the operation of the cooker hood for a established period:
20 minutes if the speed selected is 1
15 minutes if the speed selected is 2
10 minutes if the speed selected is 3
5 minutes if the boost speed P is selected.
D -Display showing: fan speed (1-2-3-P), filter saturation indicator (F for metal filter, C for charcoal filter)
Note: if in posses of the Remote Control (see paragraph "List of Part and Accessories") the display shows a
flashing "b" this to indicate that the remote control battery must be replaced.
When the led in the lower right side is on, it indicates that the cooker hood is ready for operation (“standby”
position), the flashing LED indicates that the timer has been activated for selected speed.
Warning!
The Charcoal filter saturation function is not activated.
In order to activate the charcoal filter saturation indicator, press buttons E and F simultaneously for 3 seconds.
Initially, only letter F will be displayed, then after the 3 seconds have passed, letter C will be displayed as well,
indicating that the carbon filter saturation control system is active.
To switch off the system, re-press the same two buttons: letter C appear on display and after 3 seconds it
disappears and the device will be switched off.
E -Knob to decrease the speed: from boost speed P to speed level 1.
F -Knob to increase (standby) speed to boost speed P.
Attention! Boost speed P lasts 5 minutes after which the cooker hood automatically sets the speed to level 2
(suction power).
Controls
Controlling the range hood with sliding glass:
Closing the glass, all selected speed and lights switched off.
Hood retains last speed (except P-boost-speed) setting when glass is closed and re-opened.
If the hood fails to operate correctly, briefly disconnect it from the mains power supply for almost 5 sec. by pulling out the
plug. Then plug it in again and try once more before contacting the Technical Assistance Service.
Warning!
Always press the fan off button A before disconnecting the hood from the mains supply.
Reset filter saturation signal
Press knob B for about 3 seconds.
The letter F and/or C will disappear from the display.
15
CLEANING
The cooker hood should be cleaned regularly internally and externally.
For cleaning use the supplied cloth moistened with a neutral liquid detergents. Avoid abrasive detergents.
Warning:
Failure to carry out the basic standards of the cleaning of the cooker hood and replacement of the filters may cause fire
risks.
Therefore we recommend observing these instructions.
GREASE FILTER
This must be cleaned once a month using non aggressive detergents, either by hand or in the dishwasher, which must
be set to a low temperature and a short cycle.
Maintenance
When washed in a dishwasher, the grease filter may discolour slightly, but this does not affect its filtering capacity.
To remove the grease filter, pull the spring release handle (a-b).
REPLACING THE LIGHT BULB:
WARNING
Disconnect the hood from electricity and be sure the lights are cool.
If new lights do not operate, make sure the light bulb is inserted correctly before calling service.
•Using a flat head screwdriver or equivalent tool, carefully pry loose the lamp so to unthread from the connector.
• Slide out the lightbulb to be replaced and replace with a new 12V 20W 30° Ø35 GU4 bulb type MR11, “suitable for
use in open luminarie”.
16
www.zephyronline.com
IssueCauseWhat to do
After installation, the
unit doesn’t work?
Light works, but motor is
not turning.
The unit is vibrating.
The motor is working,
but the lights are not.
1. The power source is not turned ON.
2. The power line and the cable locking
connector is not connecting properly.
3. The switch board and control board
wirings are disconnected.
4. The switch board or control board is
defective.
1. The motor is defective, possible
seized.
2. The thermally protected system
detects if the motor is too hot to
operate and shuts the motor down.
3. Damaged condenser.
1. The motor is not secure in place.
2. Damaged blower wheel.
3. The hood is not secured in place.
1. Defective halogen bulb.
2. The light bulb is loose.
1. Make sure the circuit breaker and the
unit’s power is ON.
2. Check the power connection with the
unit is connected properly.
3. Make sure the wirings between the
switch board and control board are
connected properly.
4. Change the switch board or control
board.
1. Change the motor.
2. The motor will function properly after the
thermally protected system cool down.
3. Change the condenser.
1. Tighten the motor in place.
2. Change the blower wheel.
3. Check the installation of the hood.
1. Change the halogen bulb.
2. Tighten the light bulb.
Trouble Shooting
The hood is not venting
out properly.
Metal filter is vibrating.
1. The hood might be hanging to high
from the cook top.
2. The wind from the opened windows or
opened doors in the surrounding area
are affecting the ventilation of the
hood.
3. Blocking in the duct opening or
ductwork.
4. The direction of duct opening is
against the wind.
5. Using the wrong size of ducting.
1. Metal filter is loose.
17
1. Adjust the distance between the cook
top and the bottom of the hood within
24” and 32” range.
2. Close all the windows and doors to
eliminate the outside wind flow.
3. Remove all the blocking from the duct
work or duct opening.
4. Adjust the duct opening direction.
5. Change the ducting to at least 8” or
higher.
1. Change the metal filter.
TO OBTAIN SERVICE UNDER WARRANTY:
or any Service Related Questions, please call:
1-888-880-8368
Warranty
TO OBTAIN SERVICE UNDER WARRANTY: You must present proof of original purchase date.
Please keep a copy of your dated proof of purchase (sales slip) in order to obtain service under warranty.
One Year Service Repair Warranty:
For one year from date of original purchase, we will provide free of charge, service labor to repair any failed
parts or components due to manufacturing defects.
One Year Parts Warranty:
For one year from date of original purchase, we will provide free of charge, nonconsumable replacement
parts or components that failed due to manufacturing defects. Consumable parts not covered by this warranty
include: Light Bulbs, Metal and Carbon Filters.
Who is Covered:
This warranty is extended to the original purchaser for products purchased for ordinary home use in the 48
mainland states, Hawaii and Washington D.C. In Canada and Alaska, this warranty is Limited. There might
be costs associated with shipping the products to our designated service locations or you might need to pay
service technician’s travel costs, to have the appliance repaired in-home.
Staple your receipt here.
Proof of the original purchase
date is needed to obtain service
under the warranty.
This Warranty will be Voided when:
Product damaged through negligence, misuse, abuse, accident. Improper installation and failure to follow
installation instructions.
When product is used commercially or other than its intended purpose. Damaged because of improper
connection with equipment of other manufacturers. Repaired or modified by anyone other than Zephyr’s
Authorized Agents.
What is Not Covered:
Consumable parts such as light bulbs, filters, and fuses. Services outside of service area and the labor cost
incurred in connection with the removal, shipping and reinstallation cost, nor does it cover any other
contingent expenses. The natural wear of finish, and wear due to improper maintenance, use of corrosive
and abrasive cleaning products, pads, and oven cleaner products. Chips, dents or cracks due to abuse,
misuse, freight damage, or improper installation. Service trips to your home to teach you how to use the
product. Damage of product caused by accident, fire, floods or act of God.
This warranty is valid in the United States and Canada. It is non-transferable and applies only to the original
purchaser and does not extend to subsequent owners of this product. Any applicable implied warranties,
including the warranty of merchantantability, are limited in duration to a period of express warranty as
provided herein beginning with the date of original purchase at retail and, no warranties, whether express or
implied, shall apply to this product thereafter.
Have your product proof of purchase with date ready for warranty issues.
Or write to:
Zephyr Corporation
Service and Warranty Department
395 Mendell Street
18
San Francisco, CA 94124
Part DescriptionPart#
www.zephyronline.com
halogen bulb, 12V 20 W
metal filter
Z0B-0013
GF02ZA
Part DescriptionPart#
Ductless Recirculating Kit
charcoal replacement filter
remote control
ZRC-00GL
Z0F-C063
List of Part and Accessories
19
20
www.zephyronline.com
21