Zephyr AK7000, AK7036, AK7042 Use, Care And Installation Manual

INSTALLATION
MOUNT HEIGHTS
DUCTING
10"
36"
96"
Min 24"-Max 32"
Minimum mount height between range top to hood bottom should be no less than 24".
It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire haz­ard; while hoods mounted too high will be hard to reach and will loose its performance and efficiency.
If available, also refer range manufacturer's height clearance requirements and recom­mended hood mounting height above range.
A minimum of 6" round or 3-1/4” x 10"rectangular duct must be used to maintain maximum air flow efficiency.
Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%.
Also use calculation (on right) to compute total available duct run when using elbows, transitions and caps.
ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase duct size from 6" to 7 or 8". If a reducer is used, install a long reducer instead of a pancake reducer. Reduce duct size as far away from open­ing as possible.
If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible.
Duct Run Calculation:
Maximum run 6" or 3-1/4” x 10" duct
Deduct: each 90 Elbow used each 45 elbow used each 6" to 3/14 x 10" transition used each 3/14 x 10" to 6" each 3/14 x 10" to 6" transition used Side Wall Cap w/ damper Roof Cap
100 FT
15 FT
9 FT
1 FT
5 FT 30 FT 30 FT
e.g.- 1 roof cap, 2x90 elbows, 1 x 45 elbow used:
=30' + 30' + 9' =69' used, 31' available for straight duct runs.
USE, CARE, AND INSTALLATION GUIDE
Read all Instructions before Installing and operating this appliance
MODELS: AK7000, AK7036, AK7042 Tempest I
WARNING
Installation
The installation in this manual is intended for qualified installers, service technicians or persons with similar qualified background. DO NOT attempt to install this appliance yourself. Injury could result from installing the unit due to lack of appropriate electrical and technical background.
All electrical wiring must be properly installed, insulated and grounded. Overly accumulated grease in old duct work should be cleaned out or duct work should be replaced if necessary to avoid the possibility of a grease fire. Check all joints on duct work to insure proper connection and all joints should be properly taped.
Operations
Read all instructions in this manual before operating the appliance. Save these instructions for future reference.
Always leave safety grills and filters in place. Without these components, operating blowers could catch on to hair, fingers and loose clothing.
NEVER dispose cigarette ashes, ignitable substances, or any foreign objects into blowers. NEVER leave cooking unattended. When frying, oil in the pan can easily overheat and catch fire.
The risk of self combustion is higher when the oil has been used several times.
Cleaning
The saturation of greasy residue in the blower and filters may cause increased inflammability. Keep unit clean and free of grease and residue build-up at all times to prevent possible fires.
Filters must be cleaned periodically and free from accumulation of cooking residue (see clean­ing instructions inside). Old and worn filters must be replaced immediately.Do not operateblow­ers when filters are removed. Never disassemble parts to clean without proper instructions. Disassembly is recommended to be performed by qualified personnel only.Call our service cen-
ter for removal instructions.
The manufacturer declines all responsibility in the event of failure to observe the instruc­tions given here for installation, maintenance and suitable use of the product. The manufac­turer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.
IMPORTANT SAFETY NOTICE
* Please check for latest specification revisions before any custom work or cutouts.
Models: AK7000,AK7036,AK7042 Page 1
Minimum Duct Size:
Round: 6" minimum Rectangular: 3-1/4” x 10”
INSTALLATION
SPECIFICATIONS
10"
22"
12"
2-1/4"
30"
36"
42"
TOP VIEW
8-5/8"
4-1/2"
1-1/8"
1"
1/2" Elec K.O.
CL
3-1/4"
10"
10"
TOP VIEW REAR VIEW
10"
8-5/8"
4-1/2"
3-1/4"
1-1/8"
1"
1/2" Elec K.O.
INSTALLATION
DUCTING
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or garages. All exhaust must be ducted to the outside.
Use metal ductwork only.
Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
Some Ducting Options:
WARNING FIRE HAZARD
Side wall cap w/ gravity damper
Side wall cap w/ gravity damper
Soffit or crawl space
Roof Pitch w/ Flashing & Cap
Rear Ducting
Models: AK7000,AK7036,AK7042 Page 2 Models: AK7000,AK7036,AK7042 Page 3
INSTALLATION
MOUNTING THE RANGEHOOD
INSTALLATION
MOUNTING THE RANGEHOOD
ELECTRICAL
All Electrical work must by performed by qualified electrician or person with similar technical know how and background.
For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance.
Follow National electrical codes or prevailing local codes and ordinances.
Electrical Supply:
This appliance requires a 120V 60Hz electrical supply., and connected to an individual, properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire w/ ground. Please also refer Electrical Diagram labeled on product.
Cable Lock:
A cable locking connector (not supplied) might also be required by local codes. Check with local requirements and codes, purchase and install appropriate connector if necessary.
Cable Lock
WARNING
Models: AK7000,AK7036,AK7042 Page 5Models: AK7000,AK7036,AK7042 Page 4
1. This range hood is mounted under a kitchen cabinet unit.
2. Select preferred duct location on rear or top of unit. (See page 6 & 7 for ducting conversion options)
3. Begin installation by temporarily removing the baffle filters.
4. Reinforce cabinet base with 1x2 wood strips if additional strengthening is required.
5. Temporarily position the range hood in the desired mounting location. Measure and mark the mounting holes, duct and electrical access locations with a pencil.
6. Drill/cut out the required openings for duct and electrical access; make sure the duct opening is large enough to apply duct tape.
7. Fasten hood onto cabinet with screws and washers provided.
8. Install electrical.
9. Install duct work and duct-tape.
10. Reinstall the baffle filters.
11. Power up hood and check for leaks around duct-tape.
duct/silver tape
6. Duct opening cutout
4. Add 1x2 wood strips
3. Baffle filters
INSTALLATION
CONVERTIBLE OPTIONS
Models: AK7000,AK7036,AK7042 Page 7
INSTALLATION
CONVERTIBLE OPTIONS
Models: AK7000,AK7036,AK7042 Page 6
This range hood is equipped with the option of a 6” vertical discharge, 3 1/4”x10” vertical discharge, or 3 1/4”x10” rear discharge. Additional accessories are provided to convert to either of the above discharge methods.
Convertible Options
Vertical discharge 6” round Vertical discharge 3 1/4”x10” Horizontal rear discharge 3 1/4”x10”
Convertible Accesories
Round to rectangular transition adaptor Rectangular to round transition adaptor Gasket (pre-mounted) Rectangular rear cap (pre-mounted) 3 1/4”x10” starting collar
3 1/4”x10” Vertical Discharge
1. Remove pre-mounted 6” transition adaptor or duct opening. Leave attached gasket in its original place.
3. Mount the 3-1/4”x10” starting collar on top of transition piece with remaining screws.
2. Place rectangular transition adaptor as shown over gasket and by first installing 4 screws on half round section.
(pre-mounted)
3 1/4”x10” Rear Discharge
1. At rear of range hood, remove all screws on pre­mounted rear rectangular cap and remove cap.
5. Mount starting collar (provided) at rear discharge opening with gasket.
4. Mount rectangular cap (previously removed) on top of transition adaptor.
3. Mount rectangular transition piece at opening with gasket as shown.
2. Remove top pre-mounted transition piece. Leave attached gasket in its original place.
MAINTENANCE
CLEANING
CONTROLS & FEATURES
CONTROLS & FEATURES
Models: AK7000,AK7036,AK7042 Page 8 Models: AK7000, AK7036,AK7042 Page 9
Blower On/Off5 Speed Level Indicator
Auto Mode Indicator Manual Mode Indicator Lights On/Off Indicator 5 Min Delay Off Indicator
1
Lights On/Off/Dim
3
Manual Mode Speed Selection
2
AUTO
MANUAL
Blower On/Off
By pressing , the blower is switched On and Off. When switched on, the blower stars up on speed level 5 in auto mode , and will automatically adjust the fan speed accordingly.
Delay Off
While still in auto mode , if the range hood senses no heat from below, it will reduce the blower to speed level 1, activate Delay Off , and completely shut down in 5 minutes.
Standby Mode
If the range hood was in auto mode prior to shutdown, and detects any heat from below within 20 minutes, the blower will switch back on in auto mode to speed level 5.
Manual Mode Speed Selection
Selecting or overides all auto mode controls and activates manual mode as indicated.
Lights On/Off/Dim
Switch lights On by selecting this switch. To Dim lights, activate again. Selecting one more time, will turn lights Off.
Touchless Controls Lockout Switch
Should you wish to lockout the touchless control for cleaning or safetely, an electric toggle switch is located inside the range hood (behind the baffle filters on the right hand side of the range hood) Toggle between
I (on) or 0 (off).
The control features on this range hood are
touchless; to activate simply position your
finger approximately 1/4” in front of the selected switch.
1
2
3
AUTO
MANUAL
AUTO
MANUAL
MANUAL
AUTO
MANUAL
AUTO
MANUAL
1
2
3
Surface Maintenance:
Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent (e.g. comet powder scrub, EZ-Off oven cleaner), or steel wool/scoring pads which will scratch and damage surface.
For heavier soil use liquid degreaser such as 'Formula 409' or 'Fantastic' brand cleaner. After cleaning, you may use non abrasive stainless steel polish/ cleaners such as 3M or ZEP,
to polish and buff out the stainless luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain.
Stainless Steel Baffled Filters
The stainless steel baffled filters fitted by the factory are intended to trap residue and grease from cooking. Although the filters never need replacement, they are required to be kept clean after approximately every 30 hours of use.
Removing Baffled Filters
1. Pull filter toward back of range hood using handles.
2. Pivot filter front upward.
3. Remove downwards to the rear.
WARRANTY
One Year Service Repair Warranty:
For one year from date of original purchase, we will provide free of charge, service labor to repair any failed parts or components due to manufacturing defects.
Two Years Parts Warranty:
For two years from date of original purchase, we will provide free of charge, nonconsumable replacement parts or components that failed due to manufacturing defects.
Consumable parts not covered by this warranty include: Light Bulbs, Metal and Carbon Filters.
Who is Covered:
This warranty is extended to the original purchaser for products purchased for ordinary home use in the 48 mainland states, Hawaii and Washington D.C. In Canada and Alaska, this warranty is Limited. There might be costs associated with shipping the products to our designated service locations or you might need to pay service technician's travel costs, to have the appliance repaired in-home.
This Warranty will be Voided when:
Product damaged through negligence, misuse, abuse, accident. Improper installation and failure to follow installation instructions. When product is used commercially or other than its intended purpose. Damaged because of improper connection with equipment of other manufacturers. Repaired or modified by anyone other than Zephyr's Authorized Agents.
What is Not Covered:
Consumable parts such as light bulbs, filters, and fuses. Services outside of service area and the labor cost incurred in connection with the removal, shipping and reinstallation cost, nor does it cover any other contingent expenses. The natural wear of finish, and wear due to improper maintenance, use of corrosive and abrasive cleaning products, pads, and oven cleaner products. Chips, dents or cracks due to abuse, misuse, freight damage, or improper installation. Service trips to your home to teach you how to use the product. Damage of product caused by accident, fire, floods or act of God.
This warranty is valid in the United States and Canada. It is non-transferable and applies only to the original purchaser and does not extend to subsequent owners of this product. Any applicable implied warranties, including the warranty of mer­chantability, are limited in duration to a period of express warranty as provided herein beginning with the date of original pur­chase at retail and, no warranties, whether express or implied, shall apply to this product thereafter.
TO OBTAIN SERVICE UNDER WARRANTY:
You must present proof of original purchase date.
Please keep a copy of your dated proof of purchase (sales slip)
in order to obtain service under warranty.
MAINTENANCE
LIGHTS
Replacing Light Bulbs
Make sure all power is turned off and bulbs are not hot.
Remove by turning bulb counter clockwise.
If bulbs are difficult to turn due to prolonged use, firmly attach a glass suction cup approx. the diameter of the bulb and turn.
Replacement bulbs are available at specialty lighting stores. Purchase type GU10 120V 50W halogen bulbs. Or to order bulbs, please call our service center:
888-880-8368 or online parts store:
www.zephyronline.com
CAUTION: Light bulb becomes extremely hot when turned on.
DO NOT touch bulb until switched off and cooled. Touching hot
bulbs could cause serious burns.
Models: AK7000,AK7036,AK7042 Page 10 Models:AK7000,AK7036,AK7042 Page 11
OPTIONAL ACCESSORIES
Model: AK7000 AK7036 AK7042
Back Splash AK0710 AK0716 AK0712
1-888-880-8368
Have your product proof of purchase with date ready for warranty issues.
Or write to:
Zephyr Corporation
Service and Warranty Department
395 Mendell Street
San Francisco, CA 94124
TO OBTAIN SERVICE UNDER WARRANTY
or any Service Related Questions, please call:
Loading...