TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE.
WARNING
TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.
b. Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service
panel.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. Take care when using cleaning
agents or detergents. Suitable for use in household cooking area.
WARNING
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:
a. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly
on low or medium settings.
b. Always turn hood ON when cooking at high heat or when aming food
c. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or lter.
Important Safety Notice
d. Use proper pan size. Always use cookware appropriate for the size of the surface element.
e. Keep fan, lters and grease laden surfaces clean.
f. Use high setting on hood only when necessary.
g. Don’t leave hood unattended when cooking.
h. Always use cookware and utensils appropriate for the type of and amount of food being prepared.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING:
a. SMOTHER FLAMES with a close- tting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.
If the ames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b. NEVER PICK UP A FLAMING PAN – You may be burned.
c. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d. Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how to operate it.
2. The re is small and contained in the area where it started.
3. The re department is being called.
4. You can ght the re with your back to an exit
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Installation work and electrical wiring must be done by quali ed person(s) in accordance with all applicable codes and standards.
Including re-rated construction.
b. Suf cient air is needed for power combustion and exhausting of gases through the ue (chimney) of fuel burning equipment to prevent
back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National
Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and
the local code authorities.
c. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d. Ducted fans must always vent to the outdoors.
e. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFI
(Ground Fault Interrupter protected branch circuit).
g. NEVER place a switch where it can be reached from a tub or shower.
h. Make sure the power is off before installing, wiring or maintenancing.
2
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
To reduce risk of re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings,
attics, crawl spaces or garages.
OPERATION
Always leave safety grilles and lters in place. Without these components, operating blowers could catch onto hair, ngers
and loose clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to
negligence and the warranty of the unit automatically expires due to improper maintenance.
*NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
ELECTRICAL REQUIREMENTS
Important:
Observe all governing codes and ordinances.
It is the customer’s responsibility:
- To contact a quali ed electrical installer.
- To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70
latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and
all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a quali ed electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
Check with a quali ed electrician if you are not sure the range hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit
protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to
Electrical Diagram on product.
A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase
and install appropriate connector if necessary.
Important Safety Notice
3
MODELS: AK7000AS, AK7036AS, AK7042AS
PARTS SUPPLIED
1 - Hood
2 - Baf e lters (3 - AK7036AS and AK7042AS)
2 - Halogen light bulbs (pre-installed)
1 - Single internal blower and blower plate w/damper (pre-installed)
1 - Rectangular starting collar (for single blower horizontal ducting)
1 - 6” round to rectangular transition (for single blower horizontal ducting)
1 - 6” round metal cap (for single blower horizontal ducting)
2 - Blower brackets (for single blower horizontal ducting)
List of Materials
1 - Hardware package
HARDWARE PACKAGE CONTENTS
www.zephyronline.com
Suction Cup (1)
M4 x 8 (8)
Wire Caps (3)
PARTS NOT SUPPLIED
M4 x 2” (4)
M4 x 1-1/2” (4)
M4 x 1” (4)
M3.5 x 8 (7)
10 x 3/16” (4)
- Ducting, conduit and all installation tools
- Cable connector (if required by local codes)
- Heat lamp kit
- Dual blower kit (*PBD-1100A)
* requires single blower from Tempest I to complete installation.
4
Duct pieces
3-1/ 4” x 10”
Rect.,
straight
Equivalent number
length x used =
1 Ft. x ( ) =
To t a l
Ft.
Duct pieces
6” Round
wall cap
with damper
Equivalent number
length x used =
30 Ft. x ( ) =
To t a l
Ft.
6” Round,
straight
7”-10” Round,
straight
3-1/ 4” x 10”
0
Rect.90
elbow
3-1/ 4” x 10”
0
Rect.45
elbow
3-1/ 4” x 10”
0
Rect.90
flat elbow
3-1/ 4” x 10”
Rect.
wall cap
with damper
3-1/ 4” x 10”
Rect.to
6” round
transition
3-1/ 4” x 10”
Rect.to
6” round
transition
0
elbow
90
6” Round,
0
90
elbow
1 Ft. x ( ) =
1 Ft. x ( ) =
15 Ft. x ( ) =
9 Ft. x ( ) =
24 Ft. x ( ) =
30 Ft. x ( ) =
5 Ft. x ( ) =
20 Ft. x ( ) =
15 Ft. x ( ) =
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
6” Round,
roof cap
6” round to
3-1/ 4” x 10”
rect.
transition
6” round to
3-1/ 4” x 10”
rect.
transition
0
elbow
90
7” - 10”
Round,
0
elbow
90
7” - 10”
Round,
0
elbow
45
7” - 10”
Round
wall cap
with damper
7” - 10”
Round,
roof cap
7” round to
3 1/ 4” x 10”
rect.
transition
7” round to
3-1/ 4” x 10”
rect.
transition
0
90
elbow
30 Ft. x ( ) =
1 Ft. x ( ) =
16 Ft. x ( ) =
15 Ft. x ( ) =
9 Ft. x ( ) =
30 Ft. x ( ) =
30 Ft. x ( ) =
8 Ft. x ( ) =
23 Ft. x ( ) =
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Ft.
Installation – Ducting Calculation Sheet
Ft.
6” Round,
0
elbow
45
9 Ft. x ( ) =
Subtotal column1 =
Maximum Duct Length: For satisfactory air movement,
the total duct length should not exceed 100 equivalent feet.
Ft.
Ft.
Subtotal column2 =
Subtotal column1 =
Total ductwork =
Ft.
Ft.
Ft.
5
11"
www.zephyronline.com
Minimum mount height between range top to hood
bottom should be no less than 26”.
Maximum mount height should be no higher than
36”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
result in heat damage and re hazard; while hoods
mounted too high will be hard to reach and will
lose its performance and ef ciency.
Min 26” - Max 36"
96"
36"
If available, also refer range manufacturer’s height
clearance requirements and recommended hood
mounting height above range.
Horizontal Ducting:
3-1/4”x10” minimum (single blower)
No horizontal option available for dual blower
DUCTING
A minimum of 6” round or 3-1/4” x 10” rectangular
duct must be used to maintain maximum air ow
ef ciency for single blower and 10” round duct for
dual blower.
Installation – Mounting Height & Clearance
Always use rigid type metal ducts only. Flexible
ducts could restrict air ow by up to 50%.
Also use calculation (on page 5) to compute total
available duct run when using elbows, transitions
and caps.
ALWAYS, when possible, reduce the number or
transitions and turns. If long duct run is required,
increase duct size from 6” to 7” or 8”.
If turns or transitions are required; install as far
away from hood duct output and as far apart,
between the two as possible.
6
WARNING FIRE HAZARD
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.
All exhaust must be ducted to the outside.
Use metal ductwork only.
Fasten all connections with sheet metal screws and tape all joints with certi ed Silver Tape or Duct Tape.
Some Ducting Options
Side wall cap
w/ gravity damper
Roof Pitch w/
Flashing & Cap
Soffit or crawl space
Rear Ducting
Side wall cap
w/ gravity damper
Installation – Ducting Options
7
”
1/8
1
27
33
39
7/8”
7/8
” (36”)
13/16”
13
3/16
www.zephyronline.com
(30”)
(42”)
”
”
9/16
8
Installation – Specifi cations
”
3/16
1
”
9/16
8
”
5 9/16”
7/16
6
3”
29
35
41
”
3/16
1
ø5
C
L
15/16”
15/16”
15/16”
top
27
7/8”
33
7/8
13/16”
39
C
15/16”
9
7/8”
(30”)
(36”)
(42”)
(30”)
” (36”)
(42”)
L
”
3/16
2
elec
k/o
”
3/4
2
2”
3”
12”
11”
22
1/2
3”
”
side
ø 9
15/16”
14
3/16”
10
3/8
”
”
5/16
15
29
15/16”
15/16”
35
41
15/16”
backwith 10” dual blower transition
(30”)
(36”)
(42”)
8
ELECTRICAL
WARNING
All Electrical work must by performed by qualifi ed electrician or person with similar technical know
how and background.
For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use
extension cord or adapter plug with this appliance.
Follow national electrical codes or prevailing local codes and ordinances.
Electrical Supply:
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded
branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire w/
ground. Please also refer Electrical Diagram labeled on product.
Cable Lock:
A cable locking connector (not supplied) might also be required by local codes. Check with local requirements
and codes, purchase and install appropriate connector if necessary.
Cable Lock
Installation – Mounting the Range Hood
9
For dual blower installation instructions please refer to
page 13.
www.zephyronline.com
For Mounting Under a Kitchen Cabinet
1. Select preferred duct location (vertical or horizontal).
2. Begin installation by removing the baf e lters.
3. Reinforce cabinet with 1”x2” wood strips if additional
strengthening is required or if cabinets are framed.
4. Temporarily position the range hood in the desired
mounting location. Measure and mark the mounting
holes, duct and electrical locations with a pencil.
NOTE: If using single internal blower a 6” round duct
opening is necessary. If using a dual internal blower,
please refer to page 14 for cut-out dimensions.
5. Drill/cut out the required openings for duct and
electrical access; make sure the duct opening is large
enough to apply duct tape.
10. Power up hood and check for leaks around duct tape.
5. Duct
opening
cutout
duct/silver
tape
3. Add 1x2
wood strips
2. Baffle
filters
Installation – Mounting the Range Hood
For Mounting to a Wall
1. Select preferred duct location (vertical or horizontal).
2. Begin installation by removing the baf e lters.
3. Temporarily position the range hood in the desired
mounting location. Measure and mark the mounting
holes, duct and electrical locations with a pencil.
4. Drill/cut out required openings.
5. Fasten hood onto wall with screws provided.
6. Install electrical.
7. Install duct work and duct tape.
8. Reinstall baf e lters.
9. Power up hood and check for leaks around duct tape.
10
2. Baffle
filters
This range hood is equipped standard with a 6” round vertical duct option. To convert from 6” round vertical to
3-1/4” x 10” horizontal ducting please following the instructions below.
NOTE: Horizontal ducting is only available for the single internal blower.
VERTICAL TO HORIZONTAL DUCTING CONVERSION
1. Disconnect blower wire.
3. Unscrew (4) screws holding blower to blower
plate and remove blower.
5. Re-attach blower plate to hood by following
removal instructions in reverse.
2. Remove support screw from top of hood near
the back. Remove 2 screws holding blower plate
to hood and pull blower towards front of hood to
release from internal bracket.
Installation – Horizontal Conversion
4. Cover round blower opening on blower plate
with 6” round metal cap. Attach with (3) 3.5x8
screws.
11
www.zephyronline.com
6. On the back of the hood, remove the (6) screws
holding the rectangular cap.
Installation – Horizontal Conversion
8. Picture of round to rectangular transition adapter
installed in hood.
7. Place round to rectangular transition adapter
inside hood and line it up with the rectangular
opening. Attach with (4) M4x8 screws from the
outside.
9. Attach blower brackets to blower using (2)
10x3/16” screws on each bracket.
10. Place blower inside round end of round to
rectangular transition adapter. Attach blower
with brackets to blower plate using (2) 3.5x8
screws on each bracket.
11. Attach rectangular starting collar using the (6)
screws removed from rear rectangular cap in
step 6.
12
DUAL BLOWER INSTALLATION*
*IMPORTANT: Dual blower and heat lamps may only be used together in 36” and 42” models.
30” models will only accommodate one or the other, not both at the same time.
1. Disconnect single blower wire.
3. Unscrew (4) screws holding blower to blower
plate and remove blower. Remove metal
damper. Discard single blower plate.
2. Remove support screw from top of hood near
the back. Remove 2 screws holding blower plate
to hood and pull blower towards front of hood to
release from internal bracket.
Installation – PBD-1100A Dual Blower
4. Picture of PBD-1100A dual blower kit.
5. Use the blower removed from the single blower
plate and install it into the dual blower plate.
6. Connect 9 pin male molex connector from blower
to 9 pin female molex connector on dual blower
capacitor box.
13
www.zephyronline.com
7. Secure dual blower plate to hood by following
removal instructions in reverse. Attach blower
wire to hood.
NOTE: To secure the 10” transition adapter to top of hood a cut out of 14 1/4” width x 10 1/4” depth will need
Installation – PBD-1100A Dual Blower
to be made in the cabinet bottom.
If internal cabinet dimensions prevent this size of a cut out then the 10” transition adapter may be mounted
to the cabinet bottom rather than the top of the hood. Cut out dimensions for this type of installation are
13 1/4” width x 6 1/4” depth.
8. Place 10” round adapter (included with PBD1100A) on top of hood and secure with (4)
M4x8 screws. Connect 10” duct work.
The 10” round adapter is fi tted with a metal
damper to prevent outside airfl ow from entering the kitchen.
The 6” round single blower is also fi tted with a metal damper. If using the PBD-1100A dual
blower kit, the metal damper from the 6”
round single blower must be removed prior
to instaling the 10”round adapter. See
installation step 3 on page 13.
14
HEAT LAMP KIT INSTALLATION*
*IMPORTANT: Dual blower and heat lamps may only be used together in 36” and 42” models.
30” models will only accommodate one or the other, not both at the same time.
1. Remove nuts from each of the (4) screws
around the bottom panel. Remove bottom
panel.
3. Place heat lamp housings over the (4) prethreaded screw posts inside the hood. Attach
with screws provided.
2. Replace bottom panel with heat lamp bottom
panel. Re-attach screws and nuts.
Accessory Installation – Heat Lamp Kit
4. Install heat lamp wire cover over wire from heat
lamp housing and screw shut. Repeat for each
heat lamp housing.
5. Plug heat lamp wire from hood into wire from
heat lamp housing.
Rocker Switches
6. Install heat lamp bulbs and operate heat lamps
using rocker switches located in each corner
behind the halogen bulbs.
15
Lights On/Dim/Off
4
Display
5
www.zephyronline.com
(Speed level, Delay Off Indicator)
3
5 Min Delay Off
2
Adjust 3 Speed Levels
1
Blower On/Off
By pressing , the blower is switched On and Off. When switched on, the blower turns on at the same
speed it was switched off at. When switched off the entire hood powers off, including the lights.
2
Speed Selection
The 3 speed levels are selected by pressing to decrease and to increase speed level. The
display indicates speed level selected. Pressing when the hood is off will also turn it on.
Delay Off
3
This is used for programmed shut down of blower and lights 5 minutes after the function is
activated. Press once, a dot displays in the lower right hand side of display indicating
the function is on. The hood will change to speed 1 and shut down after 5 minutes.
Lights On/Dim/Off
4
Switch lights On by pressing once, again to dim and again to switch Off.
Display
5
Displays blower speed level and delay off status.
1
Blower On/Off
Manual On/Off
Located behind the right side light panel is a manual power on/off toggle switch. This switch is used
to manually cut power to the hood to perform a hard reset for troubleshooting purposes. Toggle
between I (on) or 0 (off).
Features & Controls – Touch Controls & Features
Heat Lamps On/Off
Located on the right and left side light panel are manual power on/off toggle switches. These
switches are used to turn the heat lamps on/off. Toggle between I (on) or 0 (off).
16
SURFACE MAINTENANCE:
Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent,
or steel wool/scouring pads which will scratch and damage surface. Do not use products containing chlorine
bleach or orange cleaners.
For heavier soil use liquid degreaser.
After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish and buff out the stainless
luster and grain. Always scrub lightly using a micro ber or clean cotton cloth and with grain.
Stainless Steel Baffl e Filters
The stainless steel baf e lters are intended to trap residue and grease from cooking. Although the lters
should never need replacing, they are required to be cleaned every 30 days or more often depending on
cooking habits.
Filters may be placed in dishwasher at low heat or soaked in hot soapy water Dry lters and re-install before
using hood.
Removing Baffl e Filters
1. Push lter toward back of range hood using handles.
2. Pivot front of lter downward.
3. Remove lter by pulling away from hood.
Replacing Baffle Filters
Hood Model: Part No. Qty. to Order.
CAUTION: Light bulb becomes extremely hot when turned on.
DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns.
Make sure all power is turned off and bulbs are not hot.
Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls
out.
If bulbs are dif cult to turn due to prolonged use, rmly attach a glass suction cup approximately the diameter of
the bulb or use a rubber/latex glove and turn counter clockwise.
Replacement bulbs are available at specialty lighting stores. Purchase type MR16 (GU-10) 35W halogen.
For Zephyr part numbers please turn to page 20 of the manual.
Maintenance – Lights
18
TROUBLESHOOTING PROCEDURES FOR TEMPEST I AND TEMPEST II
IssueCauseWhat to do
After installation,
the unit doesn’t
work.
Light works,
but motor is not
turning.
The unit is
vibrating.
The motor is
working, but the
lights are not.
The hood is
not venting out
properly.
Heat lamp is not
working.
Metal lter is
vibrating.
1. The power source is not turned ON.1. Make sure the circuit breaker and the unit’s
power is ON.
2. The power line and the cable locking connector
is not connecting properly.
3. The switch board and control board wirings are
disconnected.
4. The wires on control board are loose.4. Make sure the wires on the control board are
5. The switch board or control board is defective.5. Change the switch board or control board.
1. The motor is defective, possible seized.1. Change the motor.
2. The thermally protected system detects if the
motor is too hot to operate and shuts the motor
down.
3. Damaged capacitor.3. Change the capacitor.
4. The motor wire is not connected.4. Make sure the motor wire is plugged into the
1. The motor is not secure in place.1. Tighten the motor in place.
2. Damaged blower wheel.2. Change the blower.
3. The hood is not secured in place.3. Check the installation of the hood.
1. Defective halogen bulb.1. Change the halogen bulb.
2. The light bulb is loose.2. Tighten the light bulb.
3. The wires on the control board are loose.3. Make sure the wires on control board are
1. The hood might be hanging to high from the
cook top.
2. The wind from the opened windows or opened
doors in the surrounding area are affecting the
ventilation of the hood.
3. Blockage in the duct opening or duct work.3. Remove all the blocking from the duct work or
4. The direction of duct opening is against the wind. 4. Adjust the duct opening direction.
5. Using the wrong size of ducting.5. Change the ducting to correct size.
1. Toggle switch is not in the on position.1. Make sure the heat lamp power is ON.
2. Heat lamp bulb is defective.2. Change the heat lamp bulb.
3. Heat lamp bulb is loose.3. Tighten the heat lamp bulb.
1. Metal lter is loose.1. Change the metal lter.
2. Spring clip is broken.2. Change the spring clip.
2. Check the power connection with the unit is
connected properly.
3. Make sure the wirings between the switch
board and control board are connected
properly.
connected properly.
2. The motor will function properly after the
thermally protected system cool down.
molex connector.
connected properly.
1. Adjust the distance between the cook top and
the bottom of the hood within 26” and 36”
range.
2. Close all the windows and doors to eliminate
the outside wind ow.
To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368
*IMPORTANT: Dual blower and heat lamp kits may only be used together in 36” and 42” models.
30” models will only accommodate one of the other, not both at the same time.
List of Parts and Accessories
20
TO OBTAIN SERVICE UNDER WARRANTY:
or any Service Related Questions, please call:
1-888-880-8368
Proof of the original purchase date is needed
Staple your receipt here.
to obtain service under the warranty.
TO OBTAIN SERVICE UNDER WARRANTY: You must present proof of original purchase date.
Please keep a copy of your dated proof of purchase (sales slip) in order to obtain service under warranty.
One Year Service Repair Warranty:
For one year from date of original purchase, we will provide free of charge, service labor to repair any failed parts or
components due to manufacturing defects.
Ten Years Parts Warranty:
For ten years from date of original purchase, we will provide free of charge, nonconsumable replacement parts or
components that failed due to manufacturing defects. Consumable parts not covered by this warranty include: Light Bulbs,
Metal and Carbon Filters.
Who is Covered:
This warranty is extended to the original purchaser for products purchased for ordinary home use in the 48 mainland
states, Hawaii and Washington D.C. In Canada and Alaska, this warranty is Limited. There might be costs associated with
shipping the products to our designated service locations or you might need to pay service technician’s travel costs, to
have the appliance repaired in-home.
Warranty
This Warranty will be Voided When:
Product damaged through negligence, misuse, abuse, accident. Improper installation and failure to follow installation
instructions. When product is used commercially or other than its intended purpose. Damaged because of improper
connection with equipment of other manufacturers. Repaired or modi ed by anyone other than Zephyr’s Authorized Agents.
What is Not Covered:
Consumable parts such as light bulbs, lters, and fuses. Services outside of service area and the labor cost incurred in
connection with the removal, shipping and reinstallation cost, nor does it cover any other contingent expenses. The natural
wear of nish, and wear due to improper maintenance, use of corrosive and abrasive cleaning products, pads, and oven
cleaner products. Chips, dents or cracks due to abuse, misuse, freight damage, or improper installation. Service trips to
your home to teach you how to use the product. Damage of product caused by accident, re, oods or act of God.
This warranty is valid in the United States and Canada. It is non-transferable and applies only to the original purchaser and does not
extend to subsequent owners of this product. Any applicable implied warranties, including the warranty of merchantability, are limited
in duration to a period of express warranty as provided herein beginning with the date of original purchase at retail and, no warranties,
whether express or implied, shall apply to this product thereafter.
Have your product proof of purchase with date ready for warranty issues.
Or write to:
Zephyr Corporation
Service and Warranty Department
395 Mendell Street
San Francisco, CA 94124