Window-Type Air Conditioner Owner's Manual
TABLE OF CONTENTS
Safety Precautions..........................3
Before Operation ........................7
Introduction ....................................8
Symbols Used in this Manual ........8
Features ........................................8
Electrical Safety ..............................9
Temporary Use of an
Adapter ........................................11
Temporary Use of an
Extension Cord ............................11
Installation ....................................12
Window Requirements ................12
Size ...........................................12
Clearance .................................13
Preparation of Chassis ...............14
Unit Installation ............................15
Operating Instructions .................16
Location and Function
of Controls....................................16
Additional Features.......................17
Air Direction ..............................17
Drain Pipe..................................17
Removal from Window...............17
Maintenance and Service ............18
Air Filter ....................................18
Cleaning the Air Conditioner .....18
How to Remove the
Front Grille ................................18
Common Problems and
Solutions.......................................19
Troubleshooting ............................20
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Serial #
You can find the numbers on a label on the side of the
product.
Dealer's Name
Date Purchased
Staple your receipt to this page in the event you need it
to prove date of purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use and
maintain your air conditioner properly. Just a little preventive
care on your part can save you a great deal of time and
money over the life of your air conditioner.
You'll find many answers to common problems in the chart
of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call for
service at all.
PRECAUTION
Contact an Authorized Service Center for repair or
•
maintenance of this unit. Call 1-800-243-0000 to
locate the nearest ASC.
This air conditioner is not intended for use by young
•
children or invalids without supervision.
•
Young children should be supervised to ensure that
they do not play with the air conditioner.
•
If the power cord requires replacement, have an
Authorized Servicer install an exact replacement part.
•
Installation work must be performed in accordance
with the National Electric Code by qualified and
authorized personnel only.
2 Room Air Conditioner
Owner’s Manual 3
ENGLISH
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions
must be followed.
■ Incorrect operation due to ignoring instructions will cause harm or damage. The seriousness
is classified by the following indications.
■ Because of the weight of the product, it is recommended that you have a helper to assist in
the installation.
■ Meanings of symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property only.
■ Installation
Always install the expansion panel(s).
• Improper assembly or installation may cause
incorrect operation, including injury, fire, and
Do not place the power cord near a heater.
• It may cause fire and electric shock.
Do not use the power cord near flammable
gas or combustibles such as gasoline,
benzene, thinner, etc.
• It may cause explosion or fire.
Do not disassemble or modify products.
• It may cause electric shock and failure.
Be sure not to do.
Be sure to follow the instruction.
Safety Precautions
poor performance,electric shock hazards.
n
Gasoli
4 Room Air Conditioner
Safety Precautions
■ Operation
Plug in the power plug
properly.
• Otherwise, it will cause
electric shock or fire.
Do not operate or stop the
unit by inserting or pulling
out the power plug.
• It will cause electric shock or
fire.
Do not damage or use an
unspecified power cord.
• It will cause electric shock or
fire.
Do not modify power cord
length.
• It will cause electric shock or
fire.
Use the air conditioner on a
single outlet circuit. (See page 7.)
Do not share the outlet with
other appliances.
• It will cause electric shock or
fire.
Always plug into a
grounded outlet.
• No grounding may cause
electric shock.
Unplug the unit if strange
sounds, odors, or smoke
come from it.
• Otherwise it will cause fire
and electric shock accident.
Do not use the socket if it is
loose or damaged.
• It may cause fire and electric
shock.
Do not operate with wet
hands or in damp
environment.
• It may cause electric shock.
ON
ON
■ Installation
Safety Precautions
Never touch the metal parts
of the unit when removing
the filter.
• They are sharp and may
cause injury.
Do not block the inlet or
outlet.
• It may cause failure of
appliance or performance
deteriorate.
Ensure that the outer case
is not damaged by age or
wear.
• If the outer case is damaged,
it must be repaired or
replaced immediately.
Leaving it damaged could
result in the air conditioner
falling out of the window,
creating a safety hazard.
Close all doors, windows and other outside
openings to the room.
• The air conditioner must be operated in a
enclosed area to be most effective.
Do not operate the air conditioner if you
smell gas.
• It may cause explosion, fire, and burn.
If water enters the product, turn off the the
power switch of the main body of appliance.
Contact service center after taking the powerplug out from the socket.
• It will cause electric shock or failure of
machine.
Do not clean the air conditioner with water.
• Water may enter the unit and degrade the
insulation. It may cause an electric shock.
Owner’s Manual 7
ENGLISH
Before Operation
1. Plug in the power cord properly.
2. Use a dedicated circuit. Overloading the line could create a fire hazard.
3. Do not use an extension cord. See page 10 for more details.
4. Do not start/stop operation by plugging/unplugging the power cord.
5. If the power cord is damaged and requires replacement, have an Authorized
Servicer install an exact replacement part.
1. Being exposed to direct airflow for an extended period of time could be
hazardous to your health. Do not expose occupants, pets, or plants to direct
airflow for extended periods of time.
2. Due to the possibility of oxygen deficiency, ventilate the room when used
together with stoves or other heating devices.
3. Do not use this air conditioner for non-specified special pur poses (e.g.
preserving precision devices, food, pets, plants, and ar t objects). Such usage
could damage the items.
4.The air conditioner is a consumer comfort appliance, not a precision climate
control system.
1. Do not touch the metal parts of the unit when removing the filter.Injuries can
occur when handling sharp metal edges.
2. Do not use water to clean inside the air conditioner. Exposure to water can
destroy the insulation, leading to possible electric shock.
3. When cleaning the unit, first make sure that the power and breaker are turned
off.The fan rotates at a ver y high speed during operation. There is a
possibility of injury if the unit’s power is accidentally triggered on while
cleaning inner parts of the unit.
For repair and maintenance, contact an Authorized Service Center. See the
warranty page for details or call (800) 243-0000.Have your model number and
serial number available. They should be written on page 2 of this manual.
Before Operation
Preparing for Operation
Usage
Cleaning and Maintenance
Service
Introduction
Introduction
Symbols Used in this Manual
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that could cause harm to the
air conditioner.
This symbol indicates special notes.
Features
WARNING:This appliance should be installed in accordance with the
National Electric Code.
HORIZONTAL
AIR DEFLECTOR
KNOB
CABINET
ROCKER SWITCHS
AIR FILTER
INLET GRILLE
8 Room Air Conditioner
FRONT GRILLE
Electrical Safety
Owner’s Manual 9
Electrical Safety
Electrical Data
Use of extension cords
Because of potential safety hazards, we
strongly discourage the use of an extension
cord. However, if you wish to use an
extension cord, use a CSA certified/UL-listed
3-wire (grounding) extension cord, rated 15A,
125V.
All wiring should be made in accordance with
local electrical codes and regulations.
Aluminum house wiring may pose special
problems. Consult a qualified electrician.
ELECTRICAL SAFETY
IMPORTANT GROUNDING INSTRUCTIONS
Air conditioner has a three-prong grounding plug on
its power supply cord, which must be plugged into
properly grounded three-prong wall receptacle for
your protection against possible shock hazard.
230, 208, and 230/208 VOLT UNITS
These units are equipped with a three-prong
grounding plug on the power supply cord, which
must be plugged into a matching properly grounded
three-prong wall receptacle for your protection
against possible shock hazard. If such an outlet is
not present, one must be installed by a qualified
electrician in accordance with the National Electrical
Code and local codes and ordinances.
DO NOT USE AN EXTENSION CORD on 230,
208, and 230/208 Volt units.
115V~ 230V~
Use Wall Receptacle Power Supply
Standard 125V, 3-wire grounding
receptacle rated 15A, 125V AC
Standard 250V, 3-wire grounding
receptacle rated 15A, 250V AC
Use 15 AMP. time
delay fuse or 15 AMP.
circuit breaker.
Power cord may include a current
interrupter device. A test and reset button is
provided on the plug case. The device
should be tested on a periodic basis by first
pressing the TEST button and then the
RESET button. If the TEST button does not
trip or if the RESET button will not stay
engaged, discontinue use of the air
conditioner and contact a qualified service
technician.
Use 20 AMP. time
delay fuse or 20 AMP.
Standard 250V, 3-wire grounding
receptacle rated 20A, 250V AC
circuit breaker.
WARNING: This appliance must be properly grounded.
The power cord of this appliance is equipped with a three-prong grounding plug.
To minimize the risk of electric shock, use the plug with a standard three-slot
grounding wall power outlet.If the power outlet does not include a grounding slot,
have a qualified electrician replace the outlet before you use the room air
conditioner.
WARNING: Changing the outlet without making the appropriate wiring
changes will create an unsafe condition that could result in fire or
electrical shock. Refer all such work to a licensed and qualified
electrician.
WARNING: Do not cut or remove the grounding prong from the power
plug.
WARNING: Attaching the adapter ground terminal to the wall
receptacle cover screw does not ground the appliance unless the
cover screw is metal and not insulated, and the wall receptacle is
grounded through the house wiring.
WARNING: If you have any doubt whether the air conditioner is
properly grounded, have the wall receptacle and circuit checked by a
qualified electrician.
Preferred method
Ensure proper ground
exists before use
We strongly discourage the use of an adapter due to potential safety hazards.
For temporary connections, use only a UL-listed adapter, available from most
local hardware stores. Ensure that the large slot in the adapter is aligned with
the large slot in the receptacle for a proper polarity connection.
To disconnect the power cord from the adapter, use one hand on each to avoid
damaging the ground terminal. Avoid frequently unplugging the power cord as
this can lead to eventual ground terminal damage.
WARNING: Never use the appliance with a broken adapter.
We strongly discourage the use of an extension cord due to potential safety
hazards. For temporary situations, use only CSA cer tified and UL listed 3-wire
grounded extension cords, rated 15 A, 125 V.
Temporary method
Adapter Plug
Receptacle Cover
Metal Screw
Temporary Use of an Adapter
Temporary Use of an Extension Cord
ENGLIS H
,
Owner s Manual 11
Clearance
Proper clearance enhances the cooling efficiency of the unit and prevents heat
radiation of the condenser.
1. If a stor m window presents interference, fasten a 2" wide wood strip to the inner
window sill across the full width of the sill.The wood strip should be thick
enough to raise the height of the window sill so that the unit can be installed
without interference by the storm window frame.
2. See Figure. B.The top of the wood strip should be approximately 3/4" higher
than the storm window frame (Storm Window Frame) or wood strip (Outdoors)
to help condensation to drain properly to the outside.
3. Install a second wood str ip (approximately 6" long by 11/2" wide and same
thickness as first strip) in the center of the sill flush against the back off the
inner sill.This will raise the L bracket as shown Figure.B.
4. If the distance between Stor m Window Frame and Wood Strip Mounted on Top
of Inner Sill is more than 1", two of wood strips are not necessary.
OutdoorsIndoors
Inner Sill
Outer Sill
Inner Sill
Wood Strip Mounted
on Top of Inner Sill
Wood Strip for
L Bracket
3
/4"
Clearance
1" Max.
Storm
Window
Frame
Outdoors
Indoors
Outer Sill
Owner’s Manual 13
ENGLISH
Installation
Ro
o
m
Si
d
e
Center Line
Inner Sill
Outside
Inside
L
Bracket
Outer Sill
Inner Sill
Type A
7.5"
7.5"
Center Line
Installation
Preparation of Chassis
1. Insert the guide panels(Type G)
into the guides of the air conditioner
(Type H),Fasten the curtains to the
unit with screws (Type A).
: Use a long screwdriver and
installing the screws will be easier.
2. Cut the adhesive-backed seal strip
(Type E) to the window width.
Remove the backing from the seal
strip and attach the seal strip to the
underside of the bottom window.
3. Locating unit in window
Open the window and mark center line
on the center of the inner sill.
Type A
Type A
Type A
4. Attach L bracket
4-1. Install the L brackets behind the
inner window sill, with short side of
bracket as shown. Use the 2 screws
(Type A) provided.
4-2. The bracket helps to hold unit
securely in place. Be sure to place
bracket edge flush against back of
inner sill.
14 Room Air Conditioner