Installation & Operating Instructions
ä
Zenith Tudor
Single point open outlet (vented) water heaters
21600 Zenith Tudor 5 Litre over-sink water heater
p Tud over-sink water heater
21620 Zenith Tudor 10 Litre over-sink water heater
216666666 Zip Tudor 5 Litre under-sink water heater
21610 Zenith Tudor 5 Litre under-sink water heater
216666666666utor 10 Litre under-sink water heate
21630 Zenith Tudor 10 Litre under-sink water heater
99032 Telescopic Spout accessory for 21000 / 21020
99032 Telescopic Spout accessory for 21600 / 21620
990399999994 Mono vented mixer tap fo66r 21010 / 21030
99079 Mono vented mixer tap for 21610 / 21630
919111088lo vented mixer tap for 21010 / 21030
99080 Solo vented mixer tap for 21610 / 21630
99050 Hero vented mixer tap for 21010 / 21030
99081 Hero vented mixer tap for 21610 / 21630
!
Read These Warnings First
Please read all installation requirements, installation procedures and
precautions before installing any Zenith Tudor water heater.
Never attempt to install any Zenith Tudor water heater without reading all of the
applicable instructions.
Zenith Tudor water heaters are open outlet (vented) water heaters and must not
be installed in the same way as mains pressure type water heaters.
The outlet from any Zenith Tudor water heater must be connected directly to an
outlet spout on the sink and must not be obstructed by a tap or valve or in any
other way.
The water flow is controlled by a cold water tap connected before the water
heater. Cold water pushes hot water out of the tank when the cold water tap is
turned ON. Any such cold water tap should be labelled HOT.
This water heater must not be connected to more than one outlet.
All plumbing connections must be made in accordance with AS3500.
The heater is intended only for indoor use and should never be installed
outdoors or be exposed to the elements of nature.
Over-sink and under-sink models are NOT interchangeable.
Children should be supervised to ensure they do not play with the heater.
The heater is unsuited for use by children or infirm people without supervision.
If the power supply cord is damaged it must be replaced by a Zenith Service
Provider or a qualified electrician.
Do not remove the cover of the heater under any circumstances without first
isolating the heater from the power supply.
Outlet temperature should never be set to less than 60°C without due regard to
regulations governing the storage temperature of hot water.
# Quick Installation Guide
Tapware
Step One
Install approved vented tapware
see page 3
Step Two
Position heater <1000 mm from tap
see page 4
Isolation valve
Step Five
Commissioning
see page 4
before turning power on
Cold Water Supply
Flow Restrictor
Tudor Heater
Step Three
Fasten heater to wall
see page 4
Page 2 Zenith Tudor - Installation & Operating Instructions - 81333 - July - 2004
Page 2 Zenithip Tudor - Installation & Operating Instructions - 81333 - May 2003
Step Four
Connecting
see page 4
Before installing, ensure that the following are available:
Installation Requirements
Before installing, ensure that the following are available:
a) sufficient space to position the heater so there is 270 mm clear access
under the heater (over-sink models) or 270mm above (under-sink).
b) standard 10 amp 240 volt power outlet within 1500 mm of the heater
c) cold water supply with a minimum working pressure of 50 kPa and a
maximum working pressure of 750 kPa.
If pressure may exceed 750 kPa, a pressure limiting valve must be installed.
Under-sink models must be installed beneath approved vented mixer taps
requiring a single mounting point on a sink, basin or tub.
Water pressure under 100 kPa may be sufficient for over-sink heaters but may
not operate under-sink mixer taps satisfactorily.
Before installing, ensure that the following are available:
Installation Procedure
Step One - Tapware
Over-sink models must be installed with an inlet valve to control the flow from
the water supply to the heater. No valve is supplied with the heater. The water
supply and valve should be connected after the fastening the heater to the wall.
Over-sink models are supplied with a 300 mm swivel spout. An 300 mm to
HERO MIXER
Cold Water
Supply from Tap
A
C
Hot Water
Supply from Heater
SOLO MIXER
Cold Water
B
Supply to Heater
Fixing Bolt
600 mm telescopic swivel spout (99032) is available as an optional extra.
Under-sink models must be installed with approved vented tapware. It is
advisable to fit the tap to the sink before mounting the heater to the wall
beneath the sink.
1. Ensure that the flexible tubes are firmly attached to the base of the tap body.
2. Flush water supply pipes thoroughly to remove any silt or fines.
3. Fasten the tap body to the sink using the bolt & plate system provided.
4. Connect red flexible tube (from tap base "C") to the heater outlet.
5. Insert flow restrictor provided to the free end of blue flexible tube "A"
ONLY IF the water pressure is likely to exceed 250 kPa. Otherwise discard
restrictor.
6. Connect blue flexible tube (from tap base "B" ) to the heater inlet.
7. Connect blue flexible tube (from tap base "A") to the cold water supply.
Do not dismantle the assembled ta
Fixing Bolt
MONO MIXER
Cold Water Supply to
B
Heater
factory tested and sealed to provide optimum performance.
p body during installation. Mixer taps are
To adjust water temperature delivered by Solo and Hero mixer taps, see
Hot Water
Supply from Heater
C
A
Cold Water
Supply from Tap
instructions on page 7. Such adjustments should be made only by a qualified
technician.
Note: If replacing an existing open outlet (vented) water heater an isolation valve
must be fitted to the incoming water supply and a 7L/min flow restrictor fitted
at the isolation valve outlet. It is essential to establish that any existing tapware
is vented.
Zenith Tudor - Installation & Operating Instructions - 81333 - July - 2004 Page 3
Zenithp Tudor - Installation & Operating Instructions - 81333 - May 2003 Page 3