Zanussi NTRG400, 200228, NTRG800, 200229 User Manual

RANGE COMPOSITION
N 900: a range of over 150 models for the professional caterer designed to guarantee the highest level of performance, reliability, energy saving, safety standards and ergonomic operation. These concepts are reflected in the total modularity of the range that ensures innumerable configurations, either free-standing, bridged or cantilever. N900 demonstrates how advanced technology can satisfy the needs of the professional caterer. The models detailed on this sheet are 2 top gas versions ideal for uniform cooking using pots and pans, even large size ones.
200228
FUNCTIONAL AND CONSTRUCTION FEATURES
Burners in stainless steel with a
self-stabilizing flame. Each burner has 2 branches with 4 flame lines.
Piezo ignition.Worktop in 20/10 stainless steel.
Front and side panels in stainless steel with Scotch-Brite finish.
All models have right-angled side
edges to allow flush fitting joins between units, eliminating gaps and possible dirt traps.
Cooking hob in smooth-surfaced
carbon steel, guaranteeing temperature uniformity for low temperature cooking, enabling either uniform temperature across the whole hob, 2 different temperature zones on the same hob or heating of only one section of the hob.
Easy to remove hob plate.The special design of the control
knob system guarantees against water infiltration.
Main connections can be via the
N 900
GAS HOBS
base or the rear of the unit.
All gas appliances are supplied for
use with natural gas, with LPG conversion jets supplied as standard.
All top models can be easily
mounted on the refrigerated base, open base cupboards, bridging supports or cantilever systems.
IPX5 water protection.
* In accordance with H regulations for gas models belonging to Class B11 (power over 14 kW), it is
TECHNICAL DATA
CHARACTERISTICS MODELS
Power supply Gas Gas External dimensions - mm width 400 800 depth 900 900 height 250 250 Cooking surface type Smooth Smooth material Mild Steel Mild Steel Cooking surface dimensions - mm width 350 750 depth 650 650 Working temperature - min/max - °C 120, 400 120, 400 Power - kW gas 8 16 Net weight - kg. 53 105
necessary to install a chimney (if installed under a hood) or chimney and draft diverter if the waste gases are vented directly outside.
NTRG400
200228
ZANUSSI
P R O F E S S I O N A L
NTRG800
200229
200228
200229
H
348 / 748
400 / 800
55
664236
50
H
20 250
55
664236
50
H
20 250
597816900
597817000
52
H
348 / 748
400 / 800
52
597817000
LEGEND
NTRG400
200228
NTRG800
200229
H - Gas connection 1/2" 1/2"
OPTIONAL ACCESSORIES
ACCESSORIES MODELS
NTRG400
200228
NTRG800
200229
2 SIDE COVERING PANELS FOR TOP-D=900MM 206278 206278 CHIMNEY UPSTAND 400MM 206303 CHIMNEY UPSTAND 800MM 206304 DRAUGHT DIVERTER WITH 120 MM DIAMETER 206126 DRAUGHT DIVERTER WITH 150 MM DIAMETER 206132 FLUE CONDENSER FOR 1 MODULE DIAM.150MM 206156 FLUE CONDENSER FOR 1/2 MOD. DIAM.120MM 206155 FRONTAL HANDRAIL 1200 MM 206191 206191 FRONTAL HANDRAIL 1600 MM 206192 206192 FRONTAL HANDRAIL 400 MM 206166 206166 FRONTAL HANDRAIL 800 MM 206167 206167 JUNCTION SEALING KIT 206086 206086 LARGE HANDRAIL(PORTIONING SHELF)400 MM 206185 206185 LARGE HANDRAIL(PORTIONING SHELF)800 MM 206186 206186 MATCHING RING FOR FLUE CONDENSER 150DIAM 206133 PAIR OF COVERING STRIPS FOR END ELEMENTS 206234 206234 PRESSURE REGULATOR FOR GAS UNITS 927225 927225 REAR FLUE UPSTAND FOR LARGE CHIMNEY 206160 REAR FLUE UPSTAND FOR SMALL CHIMNEY 206159 SIDE HANDRAIL-RIGHT/LEFT HAND 206165 206165 WATER COLUMN EXTENSION FOR 900 LINE 206290 206290 WATER COLUMN WITH SWIVEL ARM 206288 206288