Zamel ASH-01/U User guide

STAIRCASE TIME DELAY SWITCH ASH-01/U
Zakład Mechaniki i Elektroniki
ZAMEL sp.j.
J.W. Dzida, K. Łodzińska
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
INSTRUCTION
MANUAL
DESCRIPTION
The staircase lighting time delay switch ASH-01/U is used to control ligh­ting devices on staircases and corridors. After releasing the system it switches on the lighting for the preset time by the user. After that it switches off automati­cally. The operating time can be adjusted from 10 sec to 10 min by means of a po­tentiometer. The staircase lighting time delay switch ASH-01/U can be used as standard time delay relay. The hermetic casing (IP65) secures the device functio­ning in unfavorable weather conditions.
FEATURES
● Operating time adjustment from 10 se-
conds to 10 minutes
● universal supply voltage 12÷240 V
AC/DC
● cooperation with 3- or 4-wires installa-
tion
● cable connection 0,5m length
● relay output - 1 voltage contact contact
max 16 A capacity,
● hermetic casing (IP65).
TECHNICAL PARAME-
TERS
Power supply cables: A1 (black), A2 (blue)
Input rated voltage: 12 ÷ 240 V AC/DC
Input voltage tolerance: from-5 to +10%
Nominal frequency: 50 / 60 Hz
Rated power consumption: 0,9 VA
Znamionowy pobór prądu: 8 mA
Release / output (load) cables:
Time adjustment range: from 10 sec to 10 min
Time accuracy adjustment: ±10 %
Time repeatability adjustment: ±5 %
Output relay parameters: 16 A / 250 V AC1 4000 VA
Number of switch cables: 4
Section of connecting cables: 4x 0,75 mm
Connecting cable length: 0,5 m
Ambient temperature range: from -20 to +45
Operating position: vertical, pointed down
Protection degree: IP65 (EN 60529)
Overvoltage category: II
Rated impulse withstand voltage: 1 kV (EN 61000-4-5)
Reference standards: EN 60669-1
ASH-01/U
grey / brown (connected inside)
Time adjustment: smooth (rotary potentiometer)
2
o
C
Mounting: 2x stretcher 5x(3x30)
Protective class: II
Pollution degree: 2
Dimensions: 69 x 56 x 27 mm
Weight: 0,101 kg
EN 60669-2-1 EN 61000-4-2,3,4,5,6,11
The device is designed for one-phase installation and must be installed in accor­dance with standards valid in a particular country. The
CAUTION
device should be connec-
ted according to the deta­ils included in this operating manual. In­stallation, connection and control should be carried out by a qualied electrician staff, who act in accordance with the se­rvice manual and the device functions. Di­sassembling of the device is equal with a loss of guarantee and can cause electric shock. Before installation make sure the connection cables are not under voltage. The cruciform head screwdriver 3,5 mm should be used to instal the device. Im­proper transport, storage, and use of the device inuence its wrong functioning. It is not advisable to instal the device in the following cases: if any device part is mis­sing or the device is damaged or defor­med. In case of improper functioning of the device contact the producer.
The symbol stands for selective collection of electrical and electronic devices. Placing used devices with other waste is not allowed
APPEARANCE
Time adjustment
k
c
a
l
b
e
u
l
b
g
r
e
y
b
r
o
n
w
Power supply cable (A1)
Power supply cable (A2)
Release / output (load) cables
VER. 002_06.04.2010
CONNECTINGMOUNTING
1. Disconnect the power supply from the
mains by the phase fuse, the circuit­breaker or the switch-disconnector that are joined to the proper circuit.
2. Check if there is no voltage on con-
nection cables by means of a spe­cial measure equipment.
3. Fasten the ASH-01/U to the base with
the screw.
NOTICE! It is forbidden to bore tting holes in the cover! It may result in the loss of containment of the cover and by this – the loss of guarantee!
4. Connect the cables ASH-01/U with
the hermetic installation junction box according to installing diagram.
5. Switch on the power supply from the
mains.
6. Take out the rubber hole plug cove-
ring the adjustment of the switch on threshold potentiometer.
7. Adjust the demanded switch on time
by means of a potentiometer.
8. Put back the rubber hole plug cove-
ring the potentiometer.
FUNCTIONING
After proper mounting and installation the device is ready to work. Releasing the system with the monostable pushbutton causes the lighting to switch on for the preset time. After the preset time is over the lighting is automatically switched off till its another release. The staircase li­ghting time delay switch cooperates with 3-wire or 4-wire system. While mounting the device pay attention the release and load systems are properly connected, otherwise the device can be irreparably damaged. Because of no anti-blocking system the light is constantly switched on in cases the pushbutton is blocked.
L(+)
12 ÷ 240 V AC/DC
N(-)
k
c
a
l
b
e
u
l
b
g
r
e
y
b
r
o
w
n
3 wire system 4 wire system
EXAMPLE OF INSTALLATION
L(+) N(-)
k
c
a
l
b
e
u
l
b
g
r
e
y
b
r
o
w
n
k
c
a
l
b
e
u
l
b
g
r
e
y
b
r
o
w
n
INNER DIAGRAM
czarny
black
Typical application:
The staircase lighting time delay switch ASH-01/U operating the staircase lighting works in 3-wire installation. Push-buttons (equipped with illumination) can be connec­ted parallely.
szary
grey
brąz.
brown
nieb. blue
DIMENSIONS TIME COURSE PRODUCT FAMILY
ASH-01/U belongs to staircase time delay
t
t ttt
RELAY CAPACITY
switches ASx family.
Voltage version: 24V - 24 V AC/DC U - 12÷240 V AC/DC
Device version: 01 - basic, three or four - wire
02 - anti blocking function 03 - anti blocking function and ON/
10 - anti blocking function, uent
Casing type: M - modular version (TH 35 DIN rail) N - surface mounting H - surface and hermetic casing P - surface junction box 60 version
Device
systems
AUTO/OFF functions
brightening and dimming
symbol
VER. 002_06.04.2010