Yuasa AAC2700 TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION FOR NI-MH AAC2700
Specification No. AAC2700-00
1. APPLICATION
This specification applies to the Nickel-Metal Hydride batteries of Model
AAC2700 for Consumer AA
2.ASSEMBLY & DIMENSIONS
As Exhibit 1 drawing
3. RATINGS
Item Specification
3.1 Nominal Voltage
3.2 Nominal Capacity
3.3 Minimum Capacity
1.2 V/cell
2700 mAh
2500 mAh
Version
Page
Conditions and Remarks (Temperature is 20 ± 5 except specified)
04
2/5
3.4 1 I
3.5 Standard Charge
3.6 Discharge Cut-off Voltage
3.7 Operating Temperature
— Charge
— Discharge
— Weight
— Within 1 month
— Within 3 months
— Within 1 year
A
t
2500 mA
250mA * 16 hours
1.0 V/cell
0 to 45
(Charge current 95 mA)
0 to 65
About 28 g/cell
-20 to 50 (Humidity 85%)
-20 to 40 (Humidity 85%)
-20 to 35 (Humidity 85%)
— Recommended Storage
5 to 25 (Humidity 85%)
TECHNICAL SPECIFICATION FOR NI-MH AAC2700
Specification No. AAC2700-00
4. TEST METHOD & PERFORMANCE
Item
4.1 Test condition
4.2 Standard Charge
4.3 Standard Discharge
4.4 Open Circuit Voltage
4.5 Capacity
4.6 Internal Impedance
Specification
Ambient temperature: 20 ±5 Ambient humidity: 65%±20%
1.25 V/cell
The discharge time should be more than 5 hours
50 m/cell
Version
Page
04
3/5
Conditions and Remarks (Temperature is 20
± 5
except specified)
The test is carried out with new batteries (within a month after delivery or after testing the capacity)
–Discharge at 0.2 I – Charge at 0.1 I
–Discharge at 0.2 I
A until 1.0 V/cell
t
A for 16 hours
t
A until 1.0 V/cell
t
Checked with 1000 /V within 7 days after Standard Charge
–Standard Charge
–Rest 1 hour –Standard Discharge
(5 cycles is permitted.)
At 1 kHz within 1 hour after Standard Charge
4.7 High Rate Discharge
4.8 Low Temperature Discharge (at 0 ±2 )
4.9 Capacity Retention (at 20 ±2 )
4.10 Capacity Recovery (at 20 ±2 )
4.11 Cycle life
The discharge time should be more than 48 minutes
The discharge time should be more than 4 hours
The discharge time should be more than 3.5 hours
The discharge time should be more than 4.5 hours
130 cycles
4.12 Leakage No leakage (by eyes)
–Standard Charge –Rest 1 hour –Discharge at 1 I
A until 1.0 V/cell
t
( 5 cycles is permitted )
–Standard Charge –1624 hours Rest at 0 ±2 –Discharge at 0.2 I
A until 1.0 V/cell
t
at 0 ±2 (5 cycles is permitted.)
–Standard Charge –Store with Open Circuit for 28 days at 20 ±2 –Standard Discharge
–Standard Charge –Store with Open Circuit for 1 years at 20 ±2 – Discharge at 0.2 I
A until 1.0 V/cell
t
(5 cycles is permitted.)
See the note 1
–Standard Charge –Store at 33 ±2 and Humidity 80% for 14 days
Loading...