YSI 3100, 3200 Data sheet

YSI Environmental
YSI 3100/3200 Conductivity Systems
• User-selected measurement mode: conductivity, temperature,
R
• Multipoint calibration; variety of measurements with the same cell
• High and low alarms for process applications
3200 Conductivity Instrument - Unmatched for ultrapure water
resistivity, conductance, salinity, resistance, or total dissolved solids
e s i s t a n c e Ra t i o te c h n o l o g y ™ provides unmatched accuracy for
ultrapure water
3100 Conductivity Instrument - High-accuracy
The YSI 3100 provides high-accuracy measurements for basic conductivity. Includes direct-reading digital display, adjustable temperature coefficient, and
automatic temperature compensation.
Conductivity cells with easy automatic temperature compensation
B C D
A
3200 series cells with built-in temperature sensors (see chart on back)
YSI 3252, 3417
YSI 3418
YSI 3256, 3402
YSI 3255
YSI 3401
YSI 3440
YSI 3253, 3403
YSI 3254
0 0.1 1.0 10 100 1,000 µS/cm 1 10 100 1,000
mS/cm
Conductivity Cell Selection Chart for the 3200 (For the 3100 see specific ranges on back)
E
YSI 3200 Series Conductivity Cells have built-in thermistors, allowing automatic temperature compensation. All YSI cells are calibrated according to OIML (International Organization of Legal Metrology) recommendations 56 (Standard solutions reproducing the conductivity of electrolytes) and 68 (Calibration method for conductivity cells).
• Shipped with greater than 1% cell accuracy; includes certicate of traceability
• Can be used as a secondary lab standard
• Cells can be re-calibrated (adjusted) to NIST traceable standards; YSI offers this service with a certicate of calibration and traceability
• Black platinum electrodes are extremely stable and linear; can be replatinized using the instrument
Resistor set verifies performance
The 3166 Resistor Set tight-tolerance calibrators are more precise than com­mon resistors and can verify meter performance. Six resistors included.
NIST-traceable calibrator solutions for highest accuracy
To assure quality, YSI inspects them with reference to primary standard solutions according to OIML recommendation 56. Bottles include a table of corrections at temperatures between 20 and 30°C.
YSI 3161 1,000 µS/cm ±0.50% tolerance 1 quart YSI 3163 10,000 µS/cm ±0.25% tolerance 1 quart YSI 3165 100,000 µS/cm ±0.25% tolerance 1 quart YSI 3167 1,000 µS/cm ±1.0% tolerance 8 pints YSI 3168 10,000 µS/cm ±1.0% tolerance 8 pints YSI 3169 50,000 µS/cm ±1.0% tolerance 8 pints
www.YSI.com
+1 937 767 7241 800 897 4151 (US)
www.ysi.com
YSI Environmental +1 937 767 7241 Fax +1 937 767 9353 environmental@ysi.com
YSI Integrated Systems & Services +1 508 748 0366 systems@ysi.com
SonTek/YSI +1 858 546 8327 inquiry@sontek.com
YSI Gulf Coast +1 225 753 2650 gulfcoast@ysi.com
AMJ Environmental +1 727 565 2201
amj@ysi.com
YSI Hydrodata (UK) +44 1462 673 581 europe@ysi.com
YSI Middle East (Bahrain) +973 1753 6222 halsalem@ysi.com
YSI (Hong Kong) Limited +852 2891 8154 hongkong@ysi.com
YSI (China) Limited +86 532 575 3636 beijing@ysi-china.com
YSI Nanotech (Japan) +81 44 222 0009 nanotech@ysi.com
YSI India +91 989 122 0639 sham@ysi.com
YSI Australia +61 7 390 17223
acorbett@ysi.com
ISO 9001 ISO 14001
Who’s Minding the Planet? Resistance Ratio Technology and Pure Data for a Healthy Planet are trademarks of YSI Incorporated.
©2008 YSI Incorporated Printed in USA 1208 W40-05
YSI incorporated
Whoʼs Minding
the Planet?
YSI Environmental
3200 Instrument Specifications 3100 Instrument Specifications
Technology Resistance Ratio Forced Current Modes Conductivity Conductance Conductivity
Resistivity Resistance Salinity Salinity Total Dissolved Solids Conductance Temperature Temperature
Conductance Range Accuracy Resolution Range (Conductivity) Accuracy Resolution
0 to 0.9999 µS ±0.30% full scale 0.0001 µS 0 to 49.99 µS/cm
0.950 to 9.999 µS ±0.20% full scale 0.001 µS 0 to 499.9 µS/cm ±0.50% full scale 0.1 µS/cm
9.50 to 99.99 µS ±0.10% full scale 0.01 µS 0 to 4999 µS/cm ±0.50% full scale 1 µS/cm
95.0 to 999.9 µS ±0.10% full scale 0.1 µS 0 to 49.99 mS/cm 950 to 9999 µS ±0.10% full scale 1 µS 0 to 499.9 mS/cm
9.50 to 99.99 mS ±0.10% full scale 0.01 mS
95.0 to 999.9 mS ±0.30% full scale 0.1 mS
0.95 to 3.00 S ±1.0% full scale 0.01 S
1 - Do not use K = 10 cm
2 - Requires K = 10 cm
3 - Requires K = 10 cm
Resistance Range Accuracy Resolution
0 to 9.999 ±0.2% full scale 0.001
0 to 99.99 ±0.1% full scale 0.01 0 to 999.9 ±0.1% full scale 0.1 0 to 9.999 k ±0.1% full scale 0.001 k 0 to 99.99 k ±0.1% full scale 0.01 k
100.0 to 999.9 k ±0.2% full scale 0.1 k
1.00 to 9.99 M ±0.5% full scale 0.01 M
10.0 to 29.9 M ±1% full scale 0.1 M
Salinity 0 to 80 ppt (NaCl) ±0.1 ppt 0.1 ppt 0 to 80 ppt 2% or ±0.1 ppt 0.1 ppt Temperature -5 to +100
°
C ±0.1°C 0.01°C -5 to +95°C ±0.1°C + 1 lsd 0.1°C
TDS 0 to 19,999 mg/L ±0.50% 1 mg/L
Temperature compensation
Method linear, nonlinear linear
Reference temperature 0 to 100
°
C 15 to 25°C Temperature coefficient 0 to 10%, nonlinear 0 to 4% Cell configuration storage 6 configurations na Data storage 100 points na Cell constant
0.001 to 100 cm-1 0.01, 0.1, 1, 10 cm Cell calibration up to 5 points single point Output RS232 na Alarm & clock yes na Display Graphic LCD LCD Cell connector 7-pin mini DIN 7-pin mini DIN Platinizing included included Power 115, 220 VAC 115, 220 VAC Approvals UL, CSA, CE UL, CSA, CE Environment 95% RH non-condensing 95% RH non-condensing
Cells with built-in temperature sensors
cgs S.I. Cell Overall Max Chamber Chamber Model Cell Type Cell Constant Constant Material Length O.D. I.D. Depth Volume
A 3252 dip 1.0/cm 100/m ABS plastic 146 mm 13 mm 10 mm 20 mm B 3253 dip, micro 1.0/cm 100/m Pyrex 7740 178 mm 13 mm 10 mm 51 mm C 3254 fill 1.0/cm 100/m Pyrex 7740 135 mm 19 mm 11 mm 83 mm 5 mL D 3255 flow 0.1/cm 10/m Pyrex 7740 146 mm 25 mm 21 mm 76 mm 30 mL E 3256 dip 0.1/cm 10/m Pyrex 7740 159 mm 25 mm 21 mm 52 mm
Cells without built-in temperature sensors*
cgs S.I. Cell Overall Max Chamber Chamber Model Cell Type Cell Constant Constant Material Length O.D. I.D. Depth Volume
F 3401 dip 1.0/cm 100/m Pyrex 7740 191 mm 25 mm 21 mm 76 mm G 3402 dip 0.1/cm 10/m Pyrex 7740 159 mm 25 mm 21 mm 52 mm H 3403 dip 1.0/cm 100/m Pyrex 7740 178 mm 13 mm 10 mm 51 mm I 3417 dip 1.0/cm 100/m ABS plastic 146 mm 13 mm 10 mm 20 mm I 3418 dip 0.1/cm 10/m ABS plastic 159 mm 13 mm 10 mm 30 mm J 3440 dip 10/cm 1000/m Pyrex 7740 203 mm 13 mm 2 mm 86 mm
*Requires a YSI 3232 Cell Adaptor for use with YSI 3100 and 3200 Conductivity Instruments. For automatic temperature compensation, use a YSI 3220 on the 3200 or a YSI Series 700 Temperature Probe.
1
±0.50% full scale 0.01 µS/cm
2
±0.50% full scale 0.01 mS/cm
3
±0.50% full scale 0.1 mS/cm
-1
cell.
-1
-1
or 1.0 cm
-1
cell
cell
-1
Loading...