York YCJF24 User Manual

TECHNICAL GUIDE
SPLIT-SYSTEM AIR CONDITIONERS
14.5 SEER – R-410A MODELS:
YCJF24 THRU 60 (2 THRU 5 NOMINAL TONS, 1 PHASE)
Visit us on the web at www.york.com Additional rating information can be found at
www.ahridirectory.org
WARRANTY
Standard 5-year limited parts warranty. 10-year limited compressor warranty.
Extended 10-year limited parts warranty when product is registered online within 90 days of purchase for replace­ment or closing for new home construction.
LISTED
413437-YTG-E-0909
DESCRIPTION
The 14.5 SEER Series unit is the outdoor part of a versatile cli­mate system. It is designed with a matching indoor coil compo­nent from Johnson Controls Unitary Products. Available for typical applications this climate system is supported with acces­sories and documents to serve specific functions.
FEATURES
Quality Condenser Coils - The coil is constru cted of alumi­num microchannel tubing and enhanced aluminum fins for increased efficiency and corrosion protection.
Protected Compressor - The compressor is internally pro­tected against high pressure and temperature and externally by a factory installed high pressure switch. This protects the compressor if undesirable operating conditions occur. A liq­uid line filter-drier further protects the compressor.
Durable Finish - The cabinet is made of pre-painted steel. The pre-treated galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and matted-textured finish insure less fading when exposed to sunlight.
Lower Installed Cost - Installation time and costs are reduced by easy power and control wiring connections. Available in sweat connect models only. The unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof.
Top Discharge - The warm air from the top moun ted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications.
Low Operating Sound Level - The upward air flow carries the normal operating noise away from the living area. The rigid top panel effectively isolates any motor sound. Isolated compressor mounts minimize compressor operating sounds. Additional sound attenuation is provided by a swept-wing fan blade and compressor blanket.
Low Maintenance - Long life permanently lubricated motor­bearings need no annual servicing.
Easy Service Access - Fully exposed refrigerant connec­tions, and a single panel covering the electrical controls make for easy servicing of the unit.
Secured Service Valves - Secured re-usable service valves are provided on both the liquid and vapor sweat connecti ons for ease of evacuating and charging.
U.L. and C.U.L. listed - approved for outdoor application.
Agency Listed - U.L. an d C.U.L. listed - approved for out­door application. The unit is certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
413437-YTG-E-0909
B
C
A
Physical and Electrical Data
MODEL YCJF24S41S1 YCJF30S41S1 YCJF36S41S1 YCJF42S41S1 YCJF48S41S1 YCJF60S41S1
Unit Supply Voltage 208-230V, 1 60Hz Normal Voltage Range
1
Minimum Circuit Ampacity 16.8 18.4 19.1 23.9 27.9 35.9 Max. Overcurrent Device Amps Min. Overcurrent Device Amps
2
3
25 30 30 40 45 60
20 20 20 25 30 40 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Compressor
Amps
Rated Load 12.8 14.1 14.1 17.9 21.1 27.5
Locked Rotor 58 73 77 112 115 135 Crankcase Heater No No No No No No Fan Motor Amps Rated Load .8 .8 1.5 1.5 1.5 1.5 Fan Diameter Inches 22 22 22 24 24 24
Rated HP 1/8 1/8 1/4 1/4 1/4 1/4 Fan Motor
Nominal RPM 1075 1075 850 850 850 850
Nominal CFM 2750 2800 3200 3600 3600 3700
Face Area Sq. Ft. 13.1 17.4 17.4 20.0 21.4 24.0 Coil
Rows Deep 1 1 1 1 1 1
Fin / Inches 23 23 23 23 23 23 Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD (Field Installed) 3/4 3/4 3/4 7/8 7/8 1 1/8
Unit Charge (Lbs. - Oz.)
4
3 - 2 3 - 7 3 - 10 4 - 4 4 - 9 5 - 9
Charge Per Foot, Oz. 0.62 0.62 0.62 0.67 0.67 0.75 Operating Weight Lbs. 128 130 145 172 180 199
1.Rated in accordance with ARI Standard 110, utilization range “A”.
2.Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3.Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4.The Unit Charge is correct for the outdoor unit, smallest matched evaporator coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
187 to 252
All dimensions are in inches. They are subject to change with­out notice. Certified dimensions will be provided upon request.
Unit
Model
Dimensions
1
A
(Inches)
B C Liquid Vapor
24 28 29 29
36 36 29 29 42 34 33.6 33.6 48 36 33.6 33.6
60 40 33.6 33.6
1.Including Fan Guard.
2.Adapter fitting required for 1-1/8” line set.
Refrigerant Connection
Service Valve Size
3/4”30 36 29 29
3/8”
7/8”
2
7/8”
2 Johnson Controls Unitary Products
413437-YTG-E-0909
System Charge for Various Matched Systems
Outdoor Unit YCJF24S41S1 YCJF30S41S1 YCJF36S41S1 YCJF42S41S1 YCJF48S41S1 YCJF60S41S1 Required Orifice or TXV
Factory Charge, lbs-oz 3 - 2 3 - 7 3 - 10 4 - 4 4 - 9 5 - 9 Indoor Coil
2,3,4
FC/MC/PC24 10––––– FC/MC/PC30 102–––– FC/MC/PC35 16 10 – FC/MC/PC36 1045––– FC/MC/PC37 24 19 15 – FC/MC/PC43 24 19 15 5 – FC/MC/PC48 40 32 27 17 16 – FC/MC/PC60 17 16 0 FC/MC62 25 26 18 FC64 – UC24 8––––– UC60 12 – HC30 10––––– HC36 16 11 8 – HC42 25 19 15 6 – HC60 –––000 HD24 16––––– HD36 18––––– HD48 51 42 36 24 25 – HD60 ––––2424 AHP30 16 – AHP36 19 15 – AHX30 16 11 – AHX36 11 15 – AHX42 31 27 17 – AHX48 31 27 17 16 – AHX60 – – 33222318 AHP/SHP60 ––––1– AV*24 3––––– AV*36 251915 – – – AV/SV*48 ––901– AV/SV*60 –––010 F4FP030 3––––– F4FP036 ––5––– F4FP040 ––8––– F4FP042 ––8––– F4FP045 ––9––– F5FP048 20 10 11 – F5FP060 20 10 11 – F4FV060 9 10 1 – F6FP030 17 11 – F6FP036 –118–– – F6FP042 – 231917 – – F6FP048 – 23191716 – F6FP060 33 23 23 18
FOOTNOTES:
1.Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.
2.PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
3.A TXV kit must be used with these coils to obtain system performance. Note: If a TXV is factory installed on the coil, it must be replaced with the listed TXV.
4.Refer to Technical Guide for actual system performance for specified matches.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of interconnecting line tubing.
2. Verify the TXV or orifice and additional charge required for specific evaporator coil in the system using the above table.
3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.
4. For TXV match charge weight needs to be weighed in for specific coil match and lineset length.
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set.
1
1TVM4F1 1TVM4G1 1TVM4G1 1TVM4G1 1TVM4J1 1TVM4J1
Additional Charge, oz
– 303325
Johnson Controls Unitary Products 3
413437-YTG-E-0909
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
YCJF24S41S1
YCJF30S41S1
YCJF36S41S1
YCJF42S41S1
YCJF48S41S1
YCJF60S41S1 MA20D 24 FC/MC62D 1800 57.0 39.0 14.00 12.10
YCJF24S41S1
YCJF30S41S1
For notes see Page 6.
AIR HANDLER
MODEL W
MA08B 17 FC/MC24B 800 24.8 17.3 14.35 12.15 MA08B 17 FC/MC30B 800 24.8 17.3 14.35 12.15 MA08B 17 FC/MC35B 800 25.0 17.6 14.50 12.25 MA08B 17 FC/MC36B 800 25.0 17.6 14.40 12.25 MA08B 17 FC/MC43B 800 25.2 18.0 14.60 12.35 MA12B 17 FC/MC30B 1000 28.8 20.6 14.00 12.00 MA12B 17 FC/MC35B 1000 29.0 21.0 14.05 12.00 MA12B 17 FC/MC36B 1000 29.0 21.0 14.00 12.00 MA12B 17 FC/MC43B 1000 29.6 21.6 14.45 12.00 MA12B 17 FC/MC35B 1200 34.4 25.4 14.20 12.10 MA12B 17 FC/MC36B 1200 34.2 25.0 14.00 12.00 MA12B 17 FC/MC43B 1200 35.2 26.0 14.50 12.30 MA14D 24 FC/MC48D 1200 35.6 26.4 14.65 12.35 MA16C 21 FC/MC43C 1400 40.5 30.4 14.10 12.10 MA14D 24 FC/MC48D 1400 41.0 30.8 14.40 12.30 MA16C 21 FC/MC48C 1400 41.0 30.8 14.40 12.30 MA14D 24 FC/MC60D 1400 41.0 30.8 14.35 12.10 MA16C 21 FC/MC60C 1400 41.0 30.8 14.35 12.10 MA14D 24 FC/MC62D 1400 41.0 31.0 14.45 12.05 MA16C 21 FC/MC48C 1600 46.5 32.8 14.50 12.00 MA20D 24 FC/MC48D 1600 46.5 32.8 14.50 12.00 MA16C 21 FC/MC60C 1600 46.5 32.6 14.50 12.00 MA20D 24 FC/MC60D 1600 46.5 32.6 14.50 12.00 MA20D 24 FC/MC62D 1600 47.0 32.8 14.50 12.00
14.5 SEER AC WITH MV - VARIABLE SPEED
MV12B 17 FC/MC24B 800 25.4 17.7 16.00 13.20 MV12B 17 FC/MC30B 800 25.4 17.7 16.00 13.20 MV12B 17 FC/MC35B 800 25.6 18.0 16.00 13.50 MV16C 21 FC/MC35C 800 25.6 18.0 16.00 13.50 MV12B 17 FC/MC36B 800 25.6 18.0 16.00 13.50 MV16C 21 FC/MC36C 800 25.6 18.0 16.00 13.50 MV12B 17 FC/MC43B 800 25.8 18.4 16.10 13.75 MV16C 21 FC/MC43C 800 25.8 18.4 16.10 13.75 MV16C 21 FC/MC48C 800 26.2 18.7 16.50 14.00 MV12B 17 FC/MC30B 1000 29.4 21.0 15.00 12.85 MV12B 17 FC/MC35B 1000 29.6 21.4 15.25 13.00 MV16C 21 FC/MC35C 1000 29.6 21.4 15.50 13.25 MV12B 17 FC/MC36B 1000 29.6 21.4 15.30 13.15 MV16C 21 FC/MC36C 1000 29.6 21.4 15.50 13.15 MV12B 17 FC/MC43B 1000 30.2 22.0 15.75 13.25 MV16C 21 FC/MC43C 1000 30.2 22.0 16.00 13.50 MV16C 21 FC/MC48C 1000 30.6 22.2 16.00 13.50 MV20D 24 FC/MC48D 1000 30.6 22.2 16.00 13.50
COIL
1
MODEL
14.5 SEER AC WITH MA
RATED
CFM
TOTAL SENS.
COOLING
NET MBH
SEER EER
4 Johnson Controls Unitary Products
413437-YTG-E-0909
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
YCJF36S41S1
YCJF42S41S1
YCJF48S41S1
YCJF60S41S1
YCJF24S41S1 YCJF30S41S1 AV*36 21 – 960 30.0 22.4 16.25 13.50
YCJF36S41S1
YCJF42S41S1
YCJF48S41S1
YCJF60S41S1 AV/SV*60 24 1730 56.5 38.0 14.25 12.25
YCJF24S41S1
For notes see Page 6.
AIR HANDLER
MODEL W
14.5 SEER AC WITH MV - VARIABLE SPEED (Continued)
MV12B 17 FC/MC35B 1200 35.0 25.8 15.00 12.50 MV16C 21 FC/MC35C 1200 35.2 26.0 15.75 13.00 MV12B 17 FC/MC36B 1200 34.8 25.4 15.00 12.75 MV16C 21 FC/MC36C 1200 35.0 25.6 15.50 13.00 MV12B 17 FC/MC43B 1200 35.8 26.4 15.50 13.00 MV16C 21 FC/MC43C 1200 36.0 26.6 16.00 13.25 MV12D 24 FC/MC48D 1150 36.0 26.4 16.00 13.50 MV16C 21 FC/MC48C 1200 36.2 27.0 16.25 14.00 MV20D 24 FC/MC48D 1200 36.2 27.0 16.25 14.00 MV16C 21 FC/MC43C 1400 41.0 30.8 15.00 12.75 MV16C 21 FC/MC48C 1400 41.5 31.2 15.50 13.00 MV20D 24 FC/MC48D 1400 42.0 31.4 15.50 13.00 MV20D 24 FC/MC60D 1400 41.5 31.4 15.50 13.00 MV20D 24 FC/MC62D 1400 42.0 31.4 15.75 13.00 MV12D 24 FC64D 1155 42.0 30.4 16.00 13.00 MV20D 24 FC64D 1300 42.0 31.4 16.00 13.00 MV16C 21 FC/MC48C 1600 47.0 33.0 15.25 12.75 MV20D 24 FC/MC48D 1600 47.0 33.0 15.25 12.75 MV20D 24 FC/MC60D 1600 47.0 33.0 15.25 12.75 MV20D 24 FC/MC62D 1600 47.5 33.2 15.25 12.75 MV20D 24 FC64D 1400 48.0 33.6 MV20D 24 FC/MC60D 1800 55.0 39.0 14.00 11.95 MV20D 24 FC/MC62D 1855 56.5 39.5 14.50 1250 MV20D 24 FC64D 1630 57.0 39.0 15.10 12.90
14.5 SEER AC WITH AV / SV / F*FV - VARIABLE SPEED
AV*24 17 800 25.0 18.7 15.75 13.25 AV*36 21 725 25.8 18.6 16.25 13.50
AV*36 21 – 1190 35.0 25.6 15.75 13.25
AV/SV*48 24 1220 35.4 26.2 16.00 13.50
F4FV060 24 1200 34.6 25.6 15.50 13.25 AV/SV*48 24 1385 41.5 31.0 15.50 13.00 AV/SV*60 24 1360 41.5 31.0 15.65 13.20
F4FV060 24 1350 40.0 29.6 15.00 12.50 AV/SV*48 24 1625 47.0 33.4 15.00 12.65 AV/SV*60 24 1560 47.0 33.6 15.40 13.00
F4FV060 24 1600 44.5 30.6 14.25 12.00
14.5 SEER AC WITH AHP / SHP / AHX / F*FP
AHP24 17 850 24.8 17.4 14.30 12.20
AHX30 17 820 25.8 19.3 15.75 13.25 F4FP030 17 800 24.8 17.2 14.30 12.20 F6FP030 17 850 25.6 19.1 15.60 13.10
COIL
MODEL
1
RATED
CFM
TOTAL SENS.
COOLING
NET MBH
SEER EER
16.00 13.00
14.5 SEER AC WITH AHP / SHP / AHX / F*FP (Continued)
Johnson Controls Unitary Products 5
413437-YTG-E-0909
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
MODEL W
COIL
MODEL
1
RATED
CFM
TOTAL SENS.
AHP36 21 1000 29.6 21.4 14.30 12.20 AHX30 17 1025 29.6 22.0 15.25 13.00 AHX36 21 1005 30.2 22.6 16.25 13.00 AHX42 21 990 30.6 22.8 16.50 13.25
YCJF30S41S1
AHX48 24 1090 31.0 23.6 16.50 13.25 F6FP030 17 1035 29.2 21.8 15.00 12.75 F6FP036 21 980 29.2 21.6 15.25 13.00 F6FP042 21 1065 30.8 23.4 16.50 13.25 F6FP048 24 1055 28.2 21.6 16.25 13.00
AHP36 21 1200 35.4 26.2 15.00 12.50
AHX36 21 1225 35.2 26.0 15.50 12.75
AHX42 21 1190 35.6 26.2 15.75 13.00
AHX48 24 1255 35.8 26.8 15.75 13.00
AHX60 24 1300 36.0 27.2 15.75 13.00 F4FP036 21 1200 34.2 25.2 14.00 12.00
YCJF36S41S1
F4FP040 21 1200 34.4 25.0 14.00 12.00 F4FP042 21 1200 34.4 25.0 14.00 12.00 F5FP048 24 1250 36.4 27.4 16.25 13.50 F5FP060 24 1250 34.8 26.0 15.25 13.00 F6FP036 21 1210 34.0 24.8 15.50 12.75 F6FP042 21 1290 35.6 27.0 15.75 13.00 F6FP048 24 1125 33.4 24.0 15.75 13.00 F6FP060 24 1240 35.8 26.6 15.75 13.00
AHX42 21 1395 42.0 31.6 15.00 12.50
AHX48 24 1445 42.0 32.2 15.25 12.75
AHX60 24 1440 42.0 32.2 15.25 12.75
YCJF42S41S1
F5FP048 24 1450 42.0 32.0 15.50 13.00 F5FP060 24 1500 40.0 29.8 14.75 12.50 F6FP042 21 1455 42.0 32.0 15.00 12.50 F6FP048 24 1380 39.5 29.6 15.25 12.75 F6FP060 24 1475 42.5 32.4 15.25 12.75
AHP/SHP60 24 1600 44.0 30.6 14.20 12.00
AHX48 24 1660 47.5 34.4 14.75 12.50
AHX60 24 1680 48.0 34.4 15.00 12.50
YCJF48S41S1
F5FP048 24 1700 47.5 34.0 15.00 12.75 F5FP060 24 1700 44.5 31.2 14.00 12.00 F6FP048 24 1625 44.5 31.2 14.75 12.50 F6FP060 24 1710 48.0 34.8 15.00 12.50
YCJF60S41S1
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. Cooling MBH based on 8°F entering air temperature, 50% RH, and rated air flow. EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambie nt divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.
AHX60 24 1570 55.5 37.2 14.50 12.50 F6FP060 24 1710 56.5 39.0 14.25 12.25
COOLING
NET MBH
SEER EER
1.MC coils available with a factory installed horizontal drain pan. See price pages for specific model number. — = Not applicable.
6 Johnson Controls Unitary Products
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
FURNACE**
UNIT MODEL
YCJF24S41S1
YCJF30S41S1
YCJF36S41S1
YCJF42S41S1
YCJF48S41S1
YCJF60S41S1
1.Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up.
CFM RANGE
(Min.-max.)
600 - 1000 14,17 FC/MC/PC24 800 24.8 17.3 14.00 12.00 600 - 1000 14,17 FC/MC/PC30 800 24.8 17.3 14.00 12.00 600 - 1000 14 FC/MC/PC32 800 25 17.6 14.50 12.35 600 - 1000 17,21 FC/MC/PC35 800 25 17.6 14.50 12.35 600 - 1000 14,17,21 FC/MC/PC36 800 25 17.6 14.00 12.00 600 - 1000 14 FC/MC/PC37 800 25.4 17.9 14.50 12.35 600 - 1000 17,21 FC/MC/PC43 800 25.2 18 14.70 12.50 600 - 1000 21 FC/MC/PC48 800 25.6 18.3 14.80 12.65 600 - 1000 14 HC18 800 24.2 16.7 14.00 12.00 600 - 1000 14 HC30 800 24.8 17.4 14.00 12.00 600 - 1000 17 HC36 800 25 17.6 14.00 12.00 600 - 1000 21 HC42 800 25.4 18 14.50 12.35 600 - 1000 14,17 HD24 800 25.4 17.7 14.50 12.35 600 - 1000 14,17,21 HD36 800 24.8 17 14.00 12.00 600 - 1000 21 HD48 800 25.6 17.9 14.50 12.35 600 - 1000 14,17 UC24 800 25 17.5 14.00 12.00 600 - 1000 14,17 UC30 800 25 17.5 14.00 12.00 800 - 1200 14,17 FC/MC/PC30 1000 28.8 20.6 14.00 12.00 800 - 1200 14,17 FC/MC/PC32 1000 29 21 14.00 12.00 800 - 1200 17,21 FC/MC/PC35 1000 29 21 14.00 12.00 800 - 1200 14,17,21 FC/MC/PC36 1000 29 21 14.00 12.00 800 - 1200 14 FC/MC/PC37 1000 29.6 21.6 14.50 12.35 800 - 1200 17,21 FC/MC/PC43 1000 29.6 21.6 14.50 12.35 800 - 1200 21,24 FC/MC/PC48 1000 30 21.8 14.50 12.35 800 - 1200 17 HC36 1000 29 21 14.00 12.00 800 - 1200 21 HC42 1000 29.6 21.6 14.25 12.10 800 - 1200 14,17,21 HD36 1000 28.8 20.2 14.00 12.00 800 - 1200 21,24 HD48 1000 29.8 21.4 14.50 12.35
800 - 1200 14,17 UC30 1000 29 20.8 14.00 12.00 1000 - 1400 17,21 FC/MC/PC35 1200 33.6 24.6 14.00 11.90 1000 - 1400 14,17,21 FC/MC/PC36 1200 33.4 24.2 14.00 11.85 1000 - 1400 14 FC/MC/PC37 1200 34.4 25.2 14.50 12.20 1000 - 1400 17,21 FC/MC/PC43 1200 34.4 25.2 14.50 12.20 1000 - 1400 21,24 FC/MC/PC48 1200 34.6 25.4 14.50 12.25 1000 - 1400 17 HC36 1200 33.6 24.6 14.00 11.90 1000 - 1400 21 HC42 1200 34.4 25.2 14.50 12.20 1000 - 1400 14,17,21,24 HD48 1200 34.6 25 14.50 12.20 1000 - 1400 21,24 UC60 1200 33.2 23.8 14.00 11.75 1200 - 1600 17,21 FC/MC/PC43 1400 40.5 30.4 14.00 12.00 1200 - 1600 21,24 FC/MC/PC48 1400 41.0 30.8 14.50 12.30 1200 - 1600 21,24 FC/MC/PC60 1400 41.0 30.8 14.50 12.30 1200 - 1600 21 HC42 1400 40.5 30.4 14.00 12.00 1200 - 1600 14,17,21,24 HD48 1400 41.0 30.4 14.25 12.10 1200 - 1600 21,24 HD60 1400 41.5 31.2 14.50 12.30 1200 - 1600 21,24 FC/MC62 1400 41.0 31.0 14.50 12.30 1400 - 1800 21,24 FC/MC/PC48 1600 46.5 32.8 14.25 12.10 1400 - 1800 21,24 FC/MC/PC60 1600 46.5 32.6 14.50 12.35 1400 - 1800 14,17,21,24 HD48 1600 46.5 32.6 14.50 12.35 1400 - 1800 14,17,21,24 HD60 1600 47.5 33.2 14.50 12.35 1400 - 1800 21,24 FC/MC62 1600 47.0 32.8 14.50 12.35 1600 - 2000 21,24 FC/MC/PC60 1800 54.5 38.5 13.80 11.90 1600 - 2000 24 HC60 1800 54.5 38.5 13.50 11.65 1600 - 2000 24 FC/MC62 1800 55.5 38.5 14.00 12.05
W
COIL
MODEL
RATED
CFM
COOLING
NET MBH
TOTAL SENS.
413437-YTG-E-0909
1
SEER
EER
Johnson Controls Unitary Products 7
413437-YTG-E-0909
COOLING CAP ACITY - With High Efficiency Motor Furnaces
UNIT
MODEL
YCJF24S41S1
For notes see Page 15.
FURNACE
MODEL
T*(8,L)X*A12 FC/MC/PC24A 14 775 25.4 18.6 15.50 13.20 T*(8,L)X*B12 FC/MC/PC24B 17 835 25.6 19.1 15.75 13.25
T*9X*B12 FC/MC/PC24B 17 775 25.4 18.6 15.70 13.20 T*(8,L)X*A12 FC/MC/PC30A 14 775 25.4 18.6 15.75 13.25 T*(8,L)X*B12 FC/MC/PC30B 17 835 25.6 19.1 15.75 13.25
T*9X*B12 FC/MC/PC30B 17 775 25.4 18.6 15.75 13.25 T*(8,L)X*A12 FC/MC/PC32A 14 800 25.8 19.1 15.75 13.25 T*(8,L)X*B12 FC/MC/PC35B 17 850 26.0 19.3 15.75 13.25 T*(8,L)X*C16 FC/MC/PC35C 21 625 24.6 17.2 15.75 13.25 T*(8,L)X*C20 FC/MC/PC35C 21 885 26.2 20.0 15.75 13.50
T*9X*B12 FC/MC/PC35B 17 785 25.8 19.3 15.75 13.25
T*9X*C16 FC/MC/PC35C 21 715 25.2 18.3 15.75 13.25
T*9X*C20 FC/MC/PC35C 21 825 25.8 19.2 15.75 13.50 T*(8,L)X*A12 FC/MC/PC36A 14 815 25.8 19.2 16.00 13.50 T*(8,L)X*B12 FC/MC/PC36B 17 835 26.0 19.4 15.75 13.50 T*(8,L)X*C16 FC/MC/PC36C 21 675 25.0 17.8 15.75 13.50
T*9X*B12 FC/MC/PC36B 17 775 25.4 18.5 15.75 13.25
T*9X*C16 FC/MC/PC36C 21 770 25.6 18.6 15.75 13.50
T*9X*C20 FC/MC/PC36C 21 810 25.8 19.1 15.75 13.50 T*(8,L)X*A12 FC/MC/PC37A 14 840 26.4 20.0 16.00 13.50 T*(8,L)X*B12 FC/MC/PC43B 17 865 26.6 20.2 16.00 13.50 T*(8,L)X*C16 FC/MC/PC43C 21 655 25.2 17.9 16.00 13.50
T*9X*B12 FC/MC/PC43B 17 800 26.2 19.5 16.00 13.50
T*9X*C16 FC/MC/PC43C 21 735 25.8 18.8 16.00 13.50
T*9X*C20 FC/MC/PC43C 21 790 26.2 19.4 15.75 13.25 T*(8,L)X*C16 FC/MC/PC48C 21 685 25.6 18.4 15.75 13.25
T*9X*C16 FC/MC/PC48C 21 770 26.2 19.5 15.75 13.25
T*9X*C20 FC/MC/PC48C 21 815 26.8 20.2 15.75 13.25 T*(8,L)X*A12 UC24A 14 785 25.4 18.4 16.00 13.50 T*(8,L)X*B12 UC24B 17 805 25.8 19.0 16.00 13.50
T*9X*B12 UC24B 17 775 25.4 18.4 15.75 13.25 T*(8,L)X*A12 UC30A 14 785 25.8 18.9 15.75 13.25 T*(8,L)X*B12 UC30B 17 820 25.8 18.9 15.75 13.25
T*9X*B12 UC30B 17 775 25.8 18.9 15.75 13.25 T*(8,L)X*A12 UC36A 14 780 23.8 17.5 15.25 13.00 T*(8,L)X*B12 UC36B 17 760 24.0 17.6 15.25 13.00 T*(8,L)X*C16 UC36C 21 675 23.2 16.6 15.25 13.00
T*9X*B12 UC36B 17 775 23.8 17.5 15.25 13.00
T*9X*C16 UC36C 21 770 23.8 17.6 15.25 13.00
T*9X*C20 UC36C 21 810 24.2 17.8 15.25 13.00 T*(8,L)X*A12 HD36 14 775 20.8 17.4 15.25 13.00 T*(8,L)X*B12 HD36 17 855 25.8 19.1 15.50 13.25 T*(8,L)X*C16 HD36 21 695 19.7 15.9 15.50 13.25
T*9X*B12 HD36 17 790 25.4 18.3 15.25 13.00 Y*(8,L)C*A12 FC/MC/PC24A 14 805 24.0 16.8 15.75 13.25 Y*(8,L)C*B12 FC/MC/PC24B 17 815 24.0 16.8 15.75 13.25
(Y*9C/T*9V)*B12 FC/MC/PC24B 17 790 24.0 16.8 15.75 13.25
Y*(8,L)C*A12 FC/MC/PC30A 14 805 24.0 16.8 15.75 13.25 Y*(8,L)C*B12 FC/MC/PC30B 17 815 24.0 16.8 15.75 13.25
(Y*9C/T*9V)*B12 FC/MC/PC30B 17 790 24.0 16.8 15.75 13.25
Y*(8,L)C*A12 FC/MC/PC32A 14 775 24.0 16.8 15.50 13.25 Y*(8,L)C*B12 FC/MC/PC35B 17 760 24.0 16.8 15.75 13.25
COIL
1
MODEL
14.5 SEER AC WITH VARIABLE SPEED FURNACES
W
RATED
CFM
COOLING
Net MBH
TOTAL SENS.
2
SEER EER
8 Johnson Controls Unitary Products
COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued)
UNIT
MODEL
YCJF24S41S1
YCJF30S41S1
For notes see Page 15.
FURNACE
MODEL
(Y*9C/T*9V)*B12 FC/MC/PC35B 17 815 24.0 17.0 15.75 13.25
Y*(8,L)C*A12 FC/MC/PC36A 14 805 24.0 17.0 16.00 13.50 Y*(8,L)C*B12 FC/MC/PC36B 17 765 24.0 16.7 15.75 13.50
(Y*9C/T*9V)*B12 FC/MC/PC36B 17 815 24.0 17.1 15.75 13.50
Y*(8,L)C*A12 FC/MC/PC37A 14 805 24.0 16.9 16.00 13.50 Y*(8,L)C*B12 FC/MC/PC43B 17 760 24.0 16.7 16.00 13.50
(Y*9C/T*9V)*B12 FC/MC/PC43B 17 800 24.0 16.8 16.00 13.50
Y*(8,L)C*A12 HC30 14 775 24.0 16.8 15.75 13.25 Y*(8,L)C*B12 HC36 17 760 24.0 16.7 15.75 13.50
(Y*9C/T*9V)*B12 HC36 17 815 24.0 17.0 15.75 13.50
Y*(8,L)C*A12 HD36 14 805 24.0 16.4 16.00 13.50 Y*(8,L)C*B12 HD36 17 760 24.0 16.2 15.75 13.25 Y*(8,L)C*C16 HD36 21 855 24.0 16.7 16.00 13.50
Y*(8,L)C*C20 HD36 21 750 24.0 16.1 15.75 13.25 (Y*9C/T*9V)*B12 HD36 17 815 24.0 16.4 15.75 13.25 (Y*9C/T*9V)*C16 HD36 21 785 24.0 16.4 16.00 13.50 (Y*9C/T*9V)*C20 HD36 21 760 24.0 16.1 15.75 13.25
Y*(8,L)C*A12 UC24A 14 805 24.0 16.9 16.00 13.50
Y*(8,L)C*B12 UC24B 17 815 24.0 16.9 16.00 13.25 (Y*9C/T*9V)*B12 UC24B 17 790 24.0 16.9 16.00 13.25
Y*(8,L)C*A12 UC30A 14 805 24.0 16.8 15.75 13.25
Y*(8,L)C*B12 UC30B 17 815 24.0 16.8 15.75 13.25 (Y*9C/T*9V)*B12 UC30B 17 790 24.0 16.8 15.75 13.25
Y*(8,L)C*A12 UC36A 14 805 24.0 16.8 15.25 13.00
Y*(8,L)C*B12 UC36B 17 765 24.0 16.8 15.00 13.00 (Y*9C/T*9V)*B12 UC36B 17 815 24.0 16.9 15.25 13.00
T*(8,L)X*A12 FC/MC/PC30A 14 1075 29.4 22.2 15.00 12.75
T*(8,L)X*B12 FC/MC/PC30B 17 945 29.2 21.4 15.25 13.00
T*9X*B12 FC/MC/PC30B 17 1080 29.6 22.2 15.00 12.75 T*(8,L)X*A12 FC/MC/PC32A 14 970 29.2 21.4 15.25 13.00 T*(8,L)X*B12 FC/MC/PC35B 17 1120 30.0 22.8 15.75 13.25 T*(8,L)X*C16 FC/MC/PC35C 21 1105 30.0 23.0 15.75 13.25 T*(8,L)X*C20 FC/MC/PC35C 21 850 29.0 20.8 15.75 13.25
T*9X*B12 FC/MC/PC35B 17 1085 30.0 22.6 15.00 13.00
T*9X*C16 FC/MC/PC35C 21 1075 30.0 22.6 15.00 13.00
T*9X*C20 FC/MC/PC35C 21 685 27.4 19.0 14.50 12.30 T*(8,L)X*A12 FC/MC/PC36A 14 995 29.2 21.4 15.00 12.75 T*(8,L)X*B12 FC/MC/PC36B 17 1090 29.8 22.6 15.50 13.00 T*(8,L)X*C16 FC/MC/PC36C 21 1100 30.0 22.8 15.75 13.25 T*(8,L)X*C20 FC/MC/PC36C 21 890 29.2 21.2 15.75 13.25
T*9X*B12 FC/MC/PC36B 17 1070 29.8 22.4 15.50 13.00
T*9X*C16 FC/MC/PC36C 21 1070 29.8 22.4 15.50 13.00
T*9X*C20 FC/MC/PC36C 21 735 28.0 19.6 15.25 12.75 T*(8,L)X*A12 FC/MC/PC37A 14 1105 30.6 23.4 15.25 13.00 T*(8,L)X*B12 FC/MC/PC43B 17 1125 30.8 23.6 16.00 13.50 T*(8,L)X*C16 FC/MC/PC43C 21 710 28.4 19.7 16.00 13.50 T*(8,L)X*C20 FC/MC/PC43C 21 870 29.8 21.4 16.00 13.50
T*9X*B12 FC/MC/PC43B 17 1095 30.6 23.4 16.00 13.25
T*9X*C16 FC/MC/PC43C 21 1055 30.6 23.0 16.00 13.25
T*9X*C20 FC/MC/PC43C 21 720 28.4 19.6 16.00 13.25 T*(8,L)X*C16 FC/MC/PC48C 21 730 29.0 20.2 16.25 13.25 T*(8,L)X*C20 FC/MC/PC48C 21 890 30.0 22.0 16.25 13.25
COIL
1
MODEL
14.5 SEER AC WITH VARIABLE SPEED FURNACES
W
RATED
CFM
TOTAL SENS.
COOLING
Net MBH
2
413437-YTG-E-0909
SEER EER
Johnson Controls Unitary Products 9
Loading...