96% AFUE TWO STAGE STANDARD ECM
RESIDENTIAL GAS FURNACES
MULTI-POSITION
MODELS: TM9Y
NATURAL GAS
40 - 120 MBH INPUT
Due to continuous product improvement, specific a t io ns ar e
subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY SUMMARY
A 20-year limited warranty on heat exchangers in residential applications.
A 10-year warranty on the heat exchanger in commercial
applications.
Standard 5-year limited Parts warranty.
Extended lifetime heat exchanger and 10-year limited
parts warranty when product is registered on line within
90 days of purchase for replacement or closing for new
home construction.
See Limited Warranty certificate in Users Information Manual for details.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
5129599-YTG-A-0815
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized steel tubular
primary heat exchangers. The units are factory shipped for
installation in upflow or horizontal applications and may be converted for downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV listed and may be vented either
through side wall or roof applications using approved plastic
combustion air and vent piping.
FEATURES
•Two stage heating operation includes two stage gas valve,
two stage inducer operation and constant torque standard
ECM blower operation. Adjustable delay timer allows two
stage operation with a single stage thermostat.
•Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
•Compact, easy to install, ideal height 33" tall cabinet.
•Standard ECM constant torque drive for cooling SEER
enhancement, improved comfort with optional airflow delay
profiles, and continuous fan options for IAQ performance.
•Easy access to controls to connect power/control wiring.
•Built-in, high level self diagnostics with fault code display.
•Low unit current draw requirement for easy replacement
application.
•All models are convertible to use propane (LP) gas.
•Electronic Hot Surface Ignition saves fuel use with
increased dependability and reliability.
•100% shut off main gas valve for extra safety.
•24V, 40 VA control transformer and integrated furnace control supplied for add-on cooling.
•Hi-tech tubular aluminized steel primary heat exchanger
with stainless steel tube/aluminum fin secondary heat
exchanger for outstanding efficiency.
TM9Y080B12MP111901/26.811 x 81514
TM9Y080C16MP111901/26.811 x 101514
TM9Y100C16MP111901/26.811 x 101514
TM9Y100C20MP111903/48.411 x 111514
TM9Y120D20MP111903/48.411 x 11 1514
2Johnson Controls Unitary Products
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
Output
High/Low
Blower Blower Size
Total
Unit
AFUE
High Fire
Air Temp. Rise
Max.
Over-current
Protect
Low Fire
Air Temp. Rise
Min. Wire Size
(awg) @ 75 ft.
One Way
5129599-YTG-A-0815
Supply Duct
Return
Duct
FILTER PERFORMANCE
The airflow capacity data published in the “Blower Performance” table shown represents blower performance WITHOUT
filters.
All applications of these furnaces require the use of field
installed air filters. All filter media and mounting hardware or
provisions must be field installed external to the furnace cabinet. DO NOT attempt to install any filters inside the furnace.
NOTICE
Single side return above 1800 CFM is approved as long as
the filter velocity does not exceed filter manufacturer ’s recommendation and a transition is used to allow use on a
20x25 filter.
Recommended Filter Sizes (High velocity 600 FPM)
CFM
1000A16 x 2514 x 25
1200B16 x 2516 x 25
1600C16 x 2520 x 25
2000C(2) 16 x 2520 x 25
2000D(2) 16 x 2522 x 25
1. Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity filters.
2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For
CFM greater than 1800, you may use two side returns or one side and the
bottom or one return with a transition to allow use of a 20x25 filter.
Cabinet
Size
Unit Clearances to Combustibles
ApplicationUpflowDownflowHorizontal
Top 1" 0" 0"
Vent0" 0" 0"
Rear0" 0" 0"
Side0" 0" 1"
Front*0" 0" 0"
FloorCombustible
ClosetYesYesYes
Line ContactNoNoYes
1. For combustible floors only when used with special sub-base.
* - 24" clearance in front and 18" on side recommended for service
access.
All furnaces approved for alcove and attic installation.
Side
(in)
Combustible
1
Bottom
(in)
Combustible
Condensate Neutralizer Kit - Neutralizer cartridge has a 1/2”
plastic tube fittings for installation in the drain line. Calcium carbonate refill media is also available from the Source 1 Parts
(P/N S1-02630228000).
S1-1NK0301
Side Return Filter Racks -
S1-1SR0200 - All Models
S1-1SR0402 - All Models
Bottom Return Filter Racks - 1BR05xx series are galvanized
steel filter racks. 1BR06xx are pre-painted steel filter racks to
match the appearance of the furnace cabinet.
S1-1BR0514 or 1BR0614 - For 14-1/2” cabinets
S1-1BR0517 or 1BR0617 - For 17-1/2” cabinets
S1-1BR0521 or 1BR0621 - For 21” cabinets
S1-1BR0524 or 1BR0624 - For 24-1/2” cabinets
Combustible Floor Base Kit - For installation of these furnaces in downflow applications directly onto combustible flooring material, These kits are required to prevent potential
overheating situations.tible floor base kit provides access for
combustible airflow.
S1-1CB0514 - For 14-1/2” cabinets
S1-1CB0517 - For 17-1/2” cabinets
S1-1CB0521 - For 21” cabinets
S1-1CB0524 - For 24-1/2” cabinets
High Altitude Pressure Switches - For installation where the
altitude is less than 5,000 feet it is not required that the pressure switch be changed. For altitudes above 5,000 feet, see kits
below.
S1-1PS3308 - All Models
Thermostats - Compatible thermostat controls are available
through accessory sourcing.
EXTERNAL STATIC PRESSURE SETUP
ACCESSORIES
Propane (LP) Conversion Kit - This accessory conversion kit
may be used to convert natural gas (N) units for propane (LP)
operation.
S1-1NP0347 - All Models
Concentric Vent Termination - For use through rooftop, side-
wall. Allows combustion air to enter and exhaust to exit through
single common hole. Eliminates unsightly elbows for a cleaner
installation.
Sidewall Vent Termination Kit - For use on sidewall, two-pipe
installations only. Provide a more attractive termination for locations where the terminal is visible on the side of the home.
S1-1HT0901 (3")
S1-1HT0902 (2")
Johnson Controls Unitary Products3
Set appropriate airflow per temperature rise for gas heating. Set
appropriate airflow per “Blower Performance Table” for cooling/
heat pump heating operating based on outdoor unit size.
To measure external static pressure:
•Measure the supply air static pressure
•Record this positive number
•Measure the return air static pressure
•Record this negative number
•Treat the negative number as a positive and add the two
numbers together
•This is total system static
Blower Performance CFM - Any Position (without filter)
ModelsSpeed
0.10.20.30.40.50.60.70.80.91.0
High 12901260122011601100
Medium High 11701140111010701040
40A
60B
80B
80C
100C
100C
120D
Medium990980940900860
Medium Low 900880850810770
Low 730710690650620
High 14021374135413281299
Medium High 12521233120311821150
Medium1076105910291007973
Medium Low 988967936903875
Low 798769727695650
High 14451423139713651339
Medium High 12821266123212111182
Medium1098108410591027998
Medium Low 1012993953930894
Low 865810763730689
High 17131682164316001558
Medium High 15541519148514391404
Medium13801351130212631224
Medium Low 1177114210831050988
Low 951841650588457
High 17341694165016111570
Medium High 15681537149214531414
Medium14201380133212941249
Medium 12181169112410671015