York TM9Y Technical Guide

TECHNICAL GUIDE
96% AFUE TWO STAGE STANDARD ECM RESIDENTIAL GAS FURNACES
MULTI-POSITION MODELS: TM9Y
NATURAL GAS 40 - 120 MBH INPUT
Visit us on the web at www.york.com Additional rating information can be found at
www.ahridirectory.org
WARRANTY SUMMARY
A 20-year limited warranty on heat exchangers in residen­tial applications.
A 10-year warranty on the heat exchanger in commercial applications.
Standard 5-year limited Parts warranty.
Extended lifetime heat exchanger and 10-year limited parts warranty when product is registered on line within 90 days of purchase for replacement or closing for new home construction.
See Limited Warranty certificate in Users Information Manual for details.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
5129599-YTG-A-0815
DESCRIPTION
These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized steel tubular primary heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be con­verted for downflow applications.
These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation.
These units are Category IV listed and may be vented either through side wall or roof applications using approved plastic combustion air and vent piping.
FEATURES
Two stage heating operation includes two stage gas valve, two stage inducer operation and constant torque standard ECM blower operation. Adjustable delay timer allows two stage operation with a single stage thermostat.
Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
Standard ECM constant torque drive for cooling SEER enhancement, improved comfort with optional airflow delay profiles, and continuous fan options for IAQ performance.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code display.
Low unit current draw requirement for easy replacement application.
All models are convertible to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel use with increased dependability and reliability.
100% shut off main gas valve for extra safety.
24V, 40 VA control transformer and integrated furnace con­trol supplied for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger with stainless steel tube/aluminum fin secondary heat exchanger for outstanding efficiency.
Solid removable bottom panel allows easy conversion.
Airflow leakage less than 1% of nominal airflow for duct blaster conditions.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation, burner, and blower operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and removal of blower.
External air filters used for maximum flexibility in meeting customers IAQ needs.
Insulated blower compartment for thermal and acoustic per­formance.
1/4 turn knobs provided for easy independent door removal.
Internal condensate trap design (patent pending) provides condensate management options and is self priming to pre­vent nuisance problems.
Protection included from air intake, exhaust vent or conden­sate blockage.
Venting applications maybe installed as either 2 pipe sealed combustion or single pipe vent using indoor combustion air.
5129599-YTG-A-0815
FRONT
33
A
LEFT SIDE
Combustion Air Inlet
Condensate Drain (Downflow)
Vent Outlet
Thermostat Wiring
28.5”
Gas Pipe Entry
Electrical Entry
Condensate Drain
Thermostat Wiring
RIGHT SIDE
Vent Outlet
Condensate Drain (Downflow)
14”
1”
1.5”
23”
Combustion Air Inlet
Gas Pipe Entry
Electrical Entry
Condensate Drain
Optional Return Air Cutout (Either side)
29.5”
C
SUPPLY END
.56”
.56”
20”
B
3”
23.8”
.56”
Combustion Air Inlet
Vent Outlet
RETURN END
B
24.25”
Cabinet & Duct Dimensions
Model
Nominal
CFM (m
3
/min)
Cabinet
Size
TM9Y040A10MP11 1000 A 14-1/2 13-3/8 11-3/4 113 TM9Y060B12MP11 1200 B 17-1/2 16-3/8 13-1/4 119 TM9Y080B12MP11 1200 B 17-1/2 16-3/8 14-3/4 123 TM9Y080C16MP11 1600 C 21 19-7/8 16-1/2 130 TM9Y100C16MP11 1600 C 21 19-7/8 18-1/4 136 TM9Y100C20MP11 2000 C 21 19-7/8 18-1/4 143 TM9Y120D20MP11 2000 D 24-1/2 23-3/8 21-3/4 154
Cabinet Dimensions (Inches)
ABC Lbs
Approximate
Operating Weights
Ratings & Physical / Electrical Data
Input
Model
High/Low
MBH MBH Amps % °F °F
TM9Y040A10MP11 40/26 38/25 9.5 96 25-55 25-55 TM9Y060B12MP11 60/39 58/37 9.5 95.5 35-65 35-65
TM9Y080B12MP11 80/52 77/50 9.5 96 45-75 35-65 TM9Y080C16MP11 80/52 77/50 9.5 96 40-70 25-55 TM9Y100C16MP11 100/65 96/62 9.5 96 50-80 30-60 TM9Y100C20MP11 100/65 96/62 10.9 96 45-75 30-60 TM9Y120D20MP11 120/78 115/75 10.9 96 50-80 45-75
Model
TM9Y040A10MP11 190 1/2 6.8 11 X 8 15 14
TM9Y060B12MP11 190 1/2 6.8 11 x 8 15 14
Max. Outlet
Air Temp.
°F HP Amps In.
TM9Y080B12MP11 190 1/2 6.8 11 x 8 15 14 TM9Y080C16MP11 190 1/2 6.8 11 x 10 15 14 TM9Y100C16MP11 190 1/2 6.8 11 x 10 15 14 TM9Y100C20MP11 190 3/4 8.4 11 x 11 15 14 TM9Y120D20MP11 190 3/4 8.4 11 x 11 15 14
2 Johnson Controls Unitary Products
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water.
Output
High/Low
Blower Blower Size
Total
Unit
AFUE
High Fire
Air Temp. Rise
Max.
Over-current
Protect
Low Fire
Air Temp. Rise
Min. Wire Size
(awg) @ 75 ft.
One Way