![](/html/d2/d298/d2983d966bde87d04fab13279ff8747041b3f429ab1df6c8eaf5812cb3cf7d02/bg1.png)
TECHNICAL GUIDE
95.0% AFUE SINGLE STAGE ECM
RESIDENTIAL GAS FURNACES
MULTI-POSITION
MODELS: TM9E
NATURAL GAS
40 - 120 MBH INPUT
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at
www.upgnet.com and www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY SUMMARY
A 20-year limited warranty on heat exchangers in residential
applications.
A 10-year warranty on the heat exchanger in commercial
applications.
Standard 5-year limited Parts warranty.
Extended lifetime heat exchanger and 10-year limited
parts warranty when product is registered online within
90 days of purchase for replacement or closin g for new
home construction.
See Limited Warranty certificate in Users Information Manual for details.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
1104558-YTG-C-0615
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for downflow applications.
These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are
also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and economical installation and operation.
These units are Category IV , National Fuel Gas Code and may be
vented either through side wall or roof applications using
approved plastic combustion air and vent piping. Approved plastic combustion air and vent piping include Polyflue (a polypropylene venting systems).
FEATURES
• Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
• Compact, easy to install, ideal height 33" tall cabinet.
• Blower-off delay for cooling SEER improvement.
• Easy access to controls to connect power/control wiring.
• Built-in, high level self diagnostics with fault code displays
standard on integrated control module for reliable operation.
• Low unit amp requirement for easy replacement application.
• All models are convertable to use propane (LP) gas.
• Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
• 100% shut off main gas valve for extra safety.
• 5 speed, direct drive Standard ECM style high efficiency DC
motor.
• 24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
• Hi-tech tubular aluminized steel primary heat exchanger.
• Secondary heat exchanger made of corrosion resistant
stainless steel materials.
• Timed on, adjustable off blower capability for maximum comfort.
• Blower door safety switch.
• Solid removable bottom panel allows easy conversion.
• Airflow leakage less than 1% of nominal airflow at ductblaster conditions.
• No knockouts to deal with, making installation easier.
• Movable duct connector flanges for application flexibility.
• Quiet inducer operation.
• Inducer rotates for easy conversion of venting options.
• Fully supported blower assembly for easy access and
removal of blower.
• External air filters used for maximum flexibility in meeting
customers IAQ needs.
• Protection included from air intake, exhaust vent, or condensate blockage.
• Patent pending self priming internal condensate trap design
for easy installation.
• Venting applications - may be installed as a either 2-pipe
(sealed combustion) or single-pipe vent (using indoor combustion air.
• No special vent termination required.
• 1/4 turn knobs provided for easy door removal.
• High-efficiency blower motor for lower electrical power usage
and improved A/C SEER ratings.
• Insulated blower compartment for terminal and acoustic performance.
![](/html/d2/d298/d2983d966bde87d04fab13279ff8747041b3f429ab1df6c8eaf5812cb3cf7d02/bg2.png)
1104558-YTG-C-0615
FRONT
33
A
LEFT SIDE
Combustion Air Inlet
Condensate Drain
(Downflow)
Vent Outlet
Thermostat
Wiring
28.5”
Gas Pipe
Entry
Electrical
Entry
Condensate
Drain
Thermostat
Wiring
RIGHT SIDE
Vent Outlet
Condensate Drain
(Downflow)
14”
1”
1.5”
23”
Combustion Air Inlet
Gas Pipe
Entry
Electrical
Entry
Condensate
Drain
Optional Return Air
Cutout (Either side)
29.5”
C
SUPPLY END
.56”
.56”
20”
B
3”
23.8”
.56”
Combustion
Air Inlet
Vent
Outlet
RETURN END
B
24.25”
Cabinet & Duct Dimensions
BTUH (kW)
Input
Nominal
CFM (m
3
/min)
Cabinet
Size
Cabinet Dimensions (Inches)
ABC Lbs
TM9E040A10MP11 1000 A 14-1/2 13-3/8 11-3/4 113
TM9E060B12MP11 1200 B 17-1/2 16-3/8 13-1/4 122
TM9E080B12MP11 1200 B 17-1/2 16-3/8 14-3/4 126
TM9E080C16MP11 1600 C 21 19-7/8 16-1/2 136
TM9E100C16MP11 1600 C 21 19-7/8 18-1/4 142
TM9E100C20MP11 2000 C 21 19-7/8 18-1/4 145
TM9E120D20MP11 2000 D 24-1/2 23-3/8 21-3/4 156
Approximate
Operating Weights
Ratings & Physical / Electrical Data
BTUH (kW)
Input
TM9E040A10MP11 38 1000 95.0 45-75 180 1/2 6.8 11x8 15 9.5 14
TM9E060B12MP11 57 1200 95.0 40-70 180 1/2 6.8 11x8 15 9.5 14
TM9E080B12MP11 76 1200 95.0 50-80 170 1/2 6.8 11x8 15 9.5 14
Output
TM9E080C16MP11 76 1600 95.0 40-7 0 165 1/2 6.8 11x10 15 9.5 14
TM9E100C16MP11 95 1600 95.0 45-7 5 170 1/2 6.8 11x10 15 9.5 14
TM9E100C20MP11 95 2000 95.0 50-8 0 165 3/4 8.4 11x11 15 10.9 14
TM9E120D20MP11 114 2000 95.0 50-80 175 3/4 8.4 11x11 15 10.9 14
NOTES:
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
2 Johnson Controls Unitary Products
Nominal
Airflow
AFUE
MBH CFM % °F °F HP Amps
Air Temp.
Rise
Max. Outlet
Air Temp
Blower
Blower
Over-Current
Size
Max
Protect
Total Unit
Amps
Min. wire Size
(awg) @ 75 ft
one way