York TM8X Technical Guide

TECHNICAL GUIDE
80% SINGLE STAGE ECM RESIDENTIAL GAS FURNACES MULTI-POSITION STANDARD & LOW NOx
MODELS: TM8X, TMLX
Due to continuous product improvement, specific a tions are subject to change without notice.
Visit us on the web at www.york.com Additional rating information can be found at
www.ahridirectory.org
WARRANTY
20-year limited warranty on the heat exchanger. 10-year heat exchanger warranty on commercial applications. Standard 5-year limited Parts warranty.
Extended 10-year limited parts warranty when product is registered online within 90 days of pu rchase for replace­ment or closing for new home construction.
445348-YTG-F-0715
DESCRIPTION
These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications.
These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation.
These units are Category I listed and may be common vented with another gas appliance as allowed by the National Fuel Gas Code.
FEATURES
Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
Blower-off delay for cooling SEER improvement.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
Low unit amp requirement for easy replacement application.
All models are convertable to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability.
100% shut off main gas valve for extra safety.
5 speed direct drive, X13 style high efficiency DC motor.
24V, 40 VA control transformer and blower relay supplied for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Timed on, adjustable off blower capability for maximum comfort.
Blower door safety switch.
Solid removable bottom panel allows easy conversion.
Low NOx models have been designed to meet specific code requirements.
Airflow leakage less than 1% of total airflow at ductblaster conditions.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and removal of blower.
External air filters used for maximum flexibility in meeting customers IAQ needs.
Venting applications - may be installed as a common vent with other gas-fired appliances or use a masonry chimney.
1/4 turn knobs provided for easy door removal.
High-efficiency blower motor for lower electrical power usage and improved A/C SEER ratings.
Insulated blower compartment for thermal and acoustic performance.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
445348-YTG-F-0715
LEFT SIDE
RIGHT SIDE
.5”
.5”
RETURN END
B
24.25”
29.5”
28.5”
Electrical Entry
Gas Pipe Entry
Thermostat Wiring
FRONT
14”
1”
1.5”
23”
SUPPLY END
C
24.38”
20”
.5”
B
Gas Pipe Entry
Thermostat Wiring
33”
A
.5”
Electrical Entry
Vent Connection Outlet
Vent Connection Outlet
4” Diameter
Outlet
Vent Connection
Cabinet and Duct Dimensions
Models
Nominal
CFM (m
3
/min)
Cabinet
Size
TM(8,L)X060A12MP11 1200 A 14 1/2 13 3/8 10.3 94 TM(8,L)X080B12MP11 1200 B 17 1/2 16 3/8 11.8 103 TM(8,L)X080C16MP11 1600 C 21 19 7/8 13.6 114 TM(8,L)X100C16MP11 1600 C 21 19 7/8 13.6 118 TM(8,L)X100C20MP11 2000 C 21 19 7/8 13.6 122 TM(8,L)X120C20MP11 2000 C 21 19 7/8 15.8 129
Ratings & Physical / Electrical Data
Models
Input Output
MBH MBH °F °F HP Amps TM(8,L)X060A12MP11 60 48 80.0 30-60 160 1/2 6.8 11 x 8 15 9.3 14 TM(8,L)X080B12MP11 80 64 80.0 35-65 165 1/2 6.8 11 x 8 15 9.3 14 TM(8,L)X080C16MP11 80 64 80.0 25-55 155 1/2 6.8 11 x 10 15 9.3 14 TM(8,L)X100C16MP11 100 80 80.0 35-65 165 1/2 6.8 11 x 10 15 9.3 14 TM(8,L)X100C20MP11 100 80 80.0 25-55 155 3/4 8.4 11 x 11 15 10.9 14 TM(8,L)X120C20MP11 120 96 80.0 35-65 165 3/4 8.4 11 x 11 15 10.9 14
Nominal external static pressure is 0.50” w.c. at f urnace outlet ahead of cooling coils. Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
HORIZONTAL SIDEWALL VENTING
For applications where vertical venting is not possible, the only approved method of horizontal venting is the use of an auxiliary
AFUE
Air Temp.
Rise
power vent. Auxiliary power venters must be approved by CSA, UL, or other recognized safety agencies. Follow all application and installation details provided by the manufacturer of the power vent.
Max. Outlet
Air Temp
FILTER PERFORMANCE
The airflow capacity data published in the “Blower Perfor­mance” table shown represents blower performance WITHOUT filters.
All applications of these furnaces require the use of field installed air filters. All filter media and mounting hardware or provisions must be field installed external to the furnace cabi­net. DO NOT attempt to install any filters inside the furnace.
Cabinet Dimensions (Inches)
Approximate
Operating Weights
ABC Lbs
Blower
Blower
Size
Max
Over-Current
Protect
Total Unit
Amps
Min. wire Size
(awg) @ 75 ft
one way
2 Johnson Controls Unitary Products
NOTICE
Recommended Filter Sizes
445348-YTG-F-0715
Single side return above 1800 CFM is approved as long as the filter velocity does not exceed filter manufacturer ’s rec­ommendation and a transition is used to allow use on a 20x25 filter.
CFM
1200 A 16 x 25 14 x 25 1200 B 16 x 25 16 x 25 1600 C 16 x 25 20 x 25 2000 C (2) 16 x 25 20 x 25
1. Air velocity through throwaway type filters may not exceed 300 feet per min­ute (91.4 m/min). All velocities over this require the use of high velocity fil­ters.
2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For CFM greater than 1800, you may use two side returns or one side and the bottom or one return with a transition to allow use of a 20x25 filter.
Cabinet
Size
Side
(in)
Bottom
(in)
Unit Clearances to Combustibles (All dimensions in inche s, and all surfaces identified with the unit in an up flow configuration )
Application Top Front Rear
Upflow 1 6 0 0 3 6 Combustible Yes Yes Yes No Upflow B-Vent 1 3 0 0 0 1 Combustible Yes Yes Yes No
Downflow 1 6 0 0 3 6 Downflow B-Vent 1 3 0 0 0 1 Horizontal 1 6 0 0 3 6 Combustible No Yes Yes Horizontal B-Vent 1 3 0 0 0 1 Combustible No Yes Yes
1. Special floor base or air conditioning coil required for use on combustible floor.
2. Line contact only permitted between lines formed by the inter section of the rear p anel an d side p anel (top in hori zont al position) of th e furnace jacket and build­ing joists, studs or framing.
Left
Side
ACCESSORIES
Propane (LP) Conversion Kit - This accessory conversion kit
may be used to convert natural gas units for propane (LP) oper­ation.
1NP0347 - All Models
Side Return Filter Racks -
1SR0200 - All Models 1SR0302 - All Models
Bottom Return Filter Racks - 1BR05xx series are galvanized steel filter racks. 1BR06xx are pre-painted steel filter racks to match the appearance of the furnace cabinet.
1BR0514 or 1BR0614 - For 14-1/2” cabinets 1BR0517 or 1BR0617 - For 17-1/2” cabinets 1BR0521 or 1BR0621 - For 21” cabinets
Masonry Chimney Kits - For installations where these fur­naces are vented using existing or new lined masonry chim­neys.
1CK0603 1CK0604
Right
Side
Flue
Floor/
Bottom
1
1
1
1
Closet Alcove Attic
Yes Yes Yes No Yes Yes Yes No
Line
Contact
2
Yes
2
Yes
Combustible Floor Base Kit - For installation of these fur­naces in downflow applications directly onto combustible floor­ing material. These kits are required to prevent potential overheating situations. These kits are also required in any appli­cations where the furnace in installed in a downflow configura­tion without an evaporator coil, where the combustible floor base kit provides access for combustible airflow.
1CB0514 - For 14-1/2” cabinets 1CB0517 - For 17-1/2” cabinets 1CB0521 - For 21” cabinets
High Altitude Pressure Switches - For installation where the altitude is less than 5,000 feet it is not required that the pres­sure switch be changed. For altitudes above 5,000 feet, see kits below.
1PS3301 060, 080, 120 1PS3302 100
Thermostats - Compatible thermostat controls are available through accessory sourcing. For optimum performance and installation, refer to the UPGNET “Low Voltage Wiring Diagram” document to select and apply controls.
Johnson Controls Unitary Products 3
Blower Performance CFM - Any Position (without filter)
Models Speed
High 1260 1220 1180 1150 1110 1070 1030 990 940 900
Medium High 1160 1120 1080 1030 990 950 900 850 800 760
TM(8,L)X060A12MP11
Medium 1010 960 920 880 830 780 740 680 640 590
Medium Low 860 810 770 710 670 580 560 510 460 410
Low 800 760 710 650 610 550 500 460 390 350
High 1330 1300 1270 1240 1210 1160 1130 1090 1050 1000
Medium High 1140 1100 1070 1020 990 950 900 850 800 760
TM(8,L)X080B12MP11
Medium 990 960 920 870 830 780 730 680 630 580
Medium Low 920 890 840 790 740 700 640 600 550 510
Low 820 770 730 680 630 580 540 480 430 390
High 1730 1700 1660 1610 1580 1520 1470 1410 1360 1300
Medium High 1560 1530 1490 1450 1400 1350 1310 1270 1220 1170
TM(8,L)X080C16MP11
Medium 1370 1330 1280 1230 1180 1130 1080 1030 970 910
Medium Low 1190 1140 1090 1040 990 930 870 820 750 680
Low 1000 940 880 820 750 680 600 540 460 410
High 1730 1690 1650 1610 1570 1530 1470 1420 1360 1310
Medium High 1570 1530 1490 1440 1400 1360 1320 1270 1220 1170
TM(8,L)X100C16MP11
Medium 1360 1310 1260 1220 1180 1130 1070 1010 950 890
Medium Low 1210 1160 1110 1050 1000 940 880 810 760 700
Low 1010 950 900 820 760 680 610 540 500 430
High 2230 2180 2130 2070 2020 1960 1900 1850 1790 1720
Medium High 1820 1780 1740 1680 1620 1580 1530 1470 1410 1350
TM(8,L)X100C20MP11
Medium 1610 1550 1500 1440 1390 1340 1280 1230 1170 1110
Medium Low 1440 1380 1320 1270 1210 1150 1090 1030 960 890
Low 1210 1150 1080 1020 960 890 820 740 680 640
High 2150 2020 2040 1990 1930 1880 1820 1770 1720 1660
Medium High 1780 1740 1690 1640 1590 1540 1490 1430 1380 1310
TM(8,L)X120C20MP11
Medium 1580 1520 1470 1420 1370 1320 1270 1220 1160 1090
Medium Low 1410 1350 1290 1240 1180 1130 1070 1020 950 890
Low 1190 1130 1060 1000 940 880 820 760 680 630
NOTES:
1. Airflow expressed in standard cubic feet per minute (SCFM).
2. Motor voltage at 115 V.
Airflow Data (SCFM)
Ext. Static Pressure (in. H2O)
1, 2
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Subject to change without notice. Published in U.S.A. 445348-YTG-F-0715 Copyright © 2015 by Johnson Controls, Inc. All rights reserved. Supersedes: 445348-YTG-E-0513