80% SINGLE STAGE ECM
RESIDENTIAL GAS FURNACES
MULTI-POSITION
STANDARD & LOW NOx
MODELS: TM8X, TMLX
NATURAL GAS
60 - 120 MBH INPUT
Due to continuous product improvement, specific a tions
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
20-year limited warranty on the heat exchanger.
10-year heat exchanger warranty on commercial applications.
Standard 5-year limited Parts warranty.
Extended 10-year limited parts warranty when product is
registered online within 90 days of pu rchase for replacement or closing for new home construction.
445348-YTG-F-0715
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category I listed and may be common vented
with another gas appliance as allowed by the National Fuel Gas
Code.
FEATURES
•Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
•Compact, easy to install, ideal height 33" tall cabinet.
•Blower-off delay for cooling SEER improvement.
•Easy access to controls to connect power/control wiring.
•Built-in, high level self diagnostics with fault code displays
standard on integrated control module for reliable operation.
•Low unit amp requirement for easy replacement application.
•All models are convertable to use propane (LP) gas.
•Electronic Hot Surface Ignition saves fuel cost with increased
dependability and reliability.
•100% shut off main gas valve for extra safety.
•5 speed direct drive, X13 style high efficiency DC motor.
•24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
MBHMBH°F°FHP Amps
TM(8,L)X060A12MP11604880.030-601601/26.811 x 8159.314
TM(8,L)X080B12MP11806480.035-651651/26.811 x 8159.314
TM(8,L)X080C16MP11806480.025-551551/26.811 x 10159.314
TM(8,L)X100C16MP111008080.035-651651/26.811 x 10159.314
TM(8,L)X100C20MP111008080.025-551553/48.411 x 111510.914
TM(8,L)X120C20MP111209680.035-651653/48.411 x 111510.914
Nominal external static pressure is 0.50” w.c. at f urnace outlet ahead of cooling coils.
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
HORIZONTAL SIDEWALL VENTING
For applications where vertical venting is not possible, the only
approved method of horizontal venting is the use of an auxiliary
AFUE
Air Temp.
Rise
power vent. Auxiliary power venters must be approved by CSA,
UL, or other recognized safety agencies. Follow all application
and installation details provided by the manufacturer of the
power vent.
Max. Outlet
Air Temp
FILTER PERFORMANCE
The airflow capacity data published in the “Blower Performance” table shown represents blower performance WITHOUT
filters.
All applications of these furnaces require the use of field
installed air filters. All filter media and mounting hardware or
provisions must be field installed external to the furnace cabinet. DO NOT attempt to install any filters inside the furnace.
Cabinet Dimensions (Inches)
Approximate
Operating Weights
ABC Lbs
Blower
Blower
Size
Max
Over-Current
Protect
Total Unit
Amps
Min. wire Size
(awg) @ 75 ft
one way
2Johnson Controls Unitary Products
NOTICE
Recommended Filter Sizes
445348-YTG-F-0715
Single side return above 1800 CFM is approved as long as
the filter velocity does not exceed filter manufacturer ’s recommendation and a transition is used to allow use on a
20x25 filter.
CFM
1200A16 x 2514 x 25
1200B16 x 2516 x 25
1600C16 x 2520 x 25
2000C(2) 16 x 2520 x 25
1. Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity filters.
2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For
CFM greater than 1800, you may use two side returns or one side and the
bottom or one return with a transition to allow use of a 20x25 filter.
Cabinet
Size
Side
(in)
Bottom
(in)
Unit Clearances to Combustibles (All dimensions in inche s, and all surfaces identified with the unit in an up flow configuration )
1. Special floor base or air conditioning coil required for use on combustible floor.
2. Line contact only permitted between lines formed by the inter section of the rear p anel an d side p anel (top in hori zont al position) of th e furnace jacket and building joists, studs or framing.
Left
Side
ACCESSORIES
Propane (LP) Conversion Kit - This accessory conversion kit
may be used to convert natural gas units for propane (LP) operation.
1NP0347 - All Models
Side Return Filter Racks -
1SR0200 - All Models
1SR0302 - All Models
Bottom Return Filter Racks - 1BR05xx series are galvanized
steel filter racks. 1BR06xx are pre-painted steel filter racks to
match the appearance of the furnace cabinet.
1BR0514 or 1BR0614 - For 14-1/2” cabinets
1BR0517 or 1BR0617 - For 17-1/2” cabinets
1BR0521 or 1BR0621 - For 21” cabinets
Masonry Chimney Kits - For installations where these furnaces are vented using existing or new lined masonry chimneys.
1CK0603
1CK0604
Right
Side
Flue
Floor/
Bottom
1
1
1
1
ClosetAlcoveAttic
YesYesYesNo
YesYesYesNo
Line
Contact
2
Yes
2
Yes
Combustible Floor Base Kit - For installation of these furnaces in downflow applications directly onto combustible flooring material. These kits are required to prevent potential
overheating situations. These kits are also required in any applications where the furnace in installed in a downflow configuration without an evaporator coil, where the combustible floor
base kit provides access for combustible airflow.
1CB0514 - For 14-1/2” cabinets
1CB0517 - For 17-1/2” cabinets
1CB0521 - For 21” cabinets
High Altitude Pressure Switches - For installation where the
altitude is less than 5,000 feet it is not required that the pressure switch be changed. For altitudes above 5,000 feet, see kits
below.
1PS3301 060, 080, 120
1PS3302 100
Thermostats - Compatible thermostat controls are available
through accessory sourcing. For optimum performance and
installation, refer to the UPGNET “Low Voltage Wiring Diagram”
document to select and apply controls.
Johnson Controls Unitary Products3
Blower Performance CFM - Any Position (without filter)
ModelsSpeed
High1260122011801150111010701030990940900
Medium High1160112010801030990950900850800760
TM(8,L)X060A12MP11
Medium1010960920880830780740680640590
Medium Low860810770710670580560510460410
Low800760710650610550500460390350
High1330130012701240121011601130109010501000
Medium High1140110010701020990950900850800760
TM(8,L)X080B12MP11
Medium990960920870830780730680630580
Medium Low920890840790740700640600550510
Low820770730680630580540480430390
High1730170016601610158015201470141013601300
Medium High1560153014901450140013501310127012201170
TM(8,L)X080C16MP11
Medium13701330128012301180113010801030970910
Medium Low1190114010901040990930870820750680
Low1000940880820750680600540460410
High1730169016501610157015301470142013601310
Medium High1570153014901440140013601320127012201170
TM(8,L)X100C16MP11
Medium13601310126012201180113010701010950890
Medium Low12101160111010501000940880810760700
Low1010950900820760680610540500430
High2230218021302070202019601900185017901720
Medium High1820178017401680162015801530147014101350
TM(8,L)X100C20MP11
Medium1610155015001440139013401280123011701110
Medium Low14401380132012701210115010901030960890
Low1210115010801020960890820740680640
High2150202020401990193018801820177017201660
Medium High1780174016901640159015401490143013801310
TM(8,L)X120C20MP11
Medium1580152014701420137013201270122011601090
Medium Low14101350129012401180113010701020950890
Low1190113010601000940880820760680630
NOTES:
1. Airflow expressed in standard cubic feet per minute (SCFM).