York THGD18 THRU 60 User Manual

TECHNICAL GUIDE
V A
w
SPLIT-SYSTEM HEAT PUMPS
13 SEER – R-22 MODELS:
THGD18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE)
LISTED
Due to continuous product improvement, specifications are subject to change without notice.
isit us on the web at www.york.com dditional rating information can be found at
ww.ahridirectory.org
ISO 9001
Certified Quality
Management System
365147-YTG-C-0608
DESCRIPTION
The heat pump condensing unit is the outdoor part of a versa­tile system of heating and air conditioning. It is designed to be custom-matched with one of UPG’s complete line of evapora­tor sections, with each serving a specific function. Matching Air Handlers are available for upflow, downflow, or horizontal applications to provide a complete system. Electric Heaters are available, if required. Add-on coils are available for use with upflow, downflow, or horizontal furnaces and air han­dlers.
WARRANTY
Single Phase Units:
5-year limited parts warranty. 5-year limited compressor warranty.
FEATURES
QUALITY CONDENSER COILS - The coil is constructed of copper tubing and enhanced aluminum fins for increased efficiency and corrosion protection.
PROTECTED COMPRESSOR - The compressor is inter­nally protected against high pressure, temperature, and externally by a factory installed high pressure switch. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which pro­tects the compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the compres­sor.
DURABLE FINISH - The cabinet is made of pre-painted steel. The pre-treated galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and matted-textured finish insure less fading when exposed to sunlight.
LOWER INSTALLED COST - Installation time and costs are reduced by easy power and control wiring connec­tions. Available in sweat connect models only. The unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimen­sion means less space is required on the ground or roof.
TOP DISCHARGE - The warm air from the top mounted fan is blown up away from the structure and any landscap­ing. This allows compact location on multi-unit applica­tions.
LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds.
LOW MAINTENANCE - Long life permanently lubricated motor-bearings need no annual servicing.
EASY SERVICE ACCESS - Fully exposed refrigerant con­nections, and a single panel covering the electrical con­trols make for easy servicing of the unit.
SECURED SERVICE VALVES - Secured re-usable ser- vice valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging.
U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment cer­tification program, which is based on ARI Standard 210/240.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
365147-YTG-C-0608
Physical and Electrical Data
MODEL
THGD18
S21S1
THGD24
S21S1
THGD30
S21S1
THGD36
S21S1
THGD42
S21S1
THGD48
S21S1
THGD60
S21S1
Unit Supply Voltage 208-230V, 1φ, 60Hz Normal Voltage Range
1
187 to 252
Minimum Circuit Ampacity 9.9 13.1 17.7 19.8 24.9 40.1 40.1 Max. Overcurrent Device Amps Min. Overcurrent Device Amps
2
3
15 20 30 30 40 50 60 15 15 20 20 25 45 45
Compressor Type Recip Recip Recip Recip Recip Scroll Scroll Compressor Amps
Rated Load 7.6 9.9 13.1 14.6 18.7 30.9 30.9
Locked Rotor 36 54 61 78 78 115 150 Crankcase Heater Yes Yes Yes Yes Yes No No Fan Motor Amps Rated Load 0.5 1.5 1.4 1.5 1.5 1.5 1.5 Fan Diameter Inches 24 24 24 24 24 24 24
Rated HP 1/15 1/10 1/4 1/4 1/4 1/4 1/4 Fan Motor
Nominal RPM 850 825 1100 850 850 850 850
Nominal CFM 2050 2250 3700 3700 3600 3450 3600
Face Area Sq. Ft. 15.72 18.34 20.96 23.58 23.58 24.00 27.00 Coil
Rows Deep1111122
Fin / Inches 22 22 22 22 22 22 22 Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD (Field Installed) 3/4 3/4 3/4 7/8 7/8 7/8 1-1/8
Unit Charge (Lbs. - Oz.)
4
7 - 3 7 - 7 8 - 12 9 - 1 11 - 14 13 - 4 15 - 5
Charge Per Foot, Oz. 0.68 0.68 0.68 0.70 0.70 0.70 0.76 Operating Weight Lbs. 172 184 196 208 208 275 280
1.Rated in accordance with ARI Standard 110, utilization range “A”.
2.Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3.Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4.The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon
C
A
B
request.
.
Unit
Model
18 28
A
(Inches)
1
B C Liquid Vapor
34 34 24 32 34 34 30 36 34 34 36 40 34 34
48 40 34 34 60 40 34 34 1-1/8”
1. Including Fan Guard. * Adapter fitting required for 1-1/8” line set.
Dimensions
Refrigerant Connection
Service Valve Size
3/8”
3/4”
7/8”42 40 34 34
2 Johnson Controls Unitary Products
365147-YTG-C-0608
Additional R-22 Charge / Orifice Size for Various Matched Systems
Outdoor Unit
Required Orifice or TXV
THGD18
S21S1
1
1TVM2A1 1TVM2A1 1TVM2A1 1TVM2A1 1TVM2C1 1TVM2C1 1TVM2C1
Factory Charge, lbs-oz 7 - 3 7 - 7 8 - 12 9 - 1 11 - 14 13 - 4 15 - 5
THGD24
S21S1
THGD30
S21S1
THGD36
S21S1
THGD42
S21S1
THGD48
S21S1
THGD60
S21S1
Indoor Coil
2,3
Additional Charge, Oz
FC/MC/PC/UC18A2A 0 –––––– FC/MC/PC/UC18B2A 0 –––––– FC/MC/PC/UC24A2A 0 0 ––––– FC/MC/PC/UC24B2A 0 0 ––––– FC/MC/PC/UC30A2A 0 0 ––––– FC/MC/PC/UC30B2A 0 0 ––––– FC/MC/PC/UC32A2A –5 0 –––– FC/MC/PC/UC35B2A –5 0 –––– FC/MC/PC/UC35C2A –5 0 –––– FC/MC/PC/UC37A2A – 0 0 – – FC/MC/PC/UC43C2C ––––––– FC/MC/PC/UC48C2C ––––0 –– FC/MC/PC/UC48D2C ––––0 –– FC/PC/UC60C2C ––––2 0 – FC/MC/PC/UC60D2C ––––2 0 – FC/PC62D2C –––––2 0 HC18A2A 0 –––––– HC30A2A –0 ––––– HC36B2A –5 0 –––– HC60C2C ––––2 0 – HD24A2A –4 ––––– HD36B2A ––0 –––– HD60D2C ––––2 0 – MH30S2A –6 ––––– AHP18B2A 0 –––––– AHP24B2A 0 0 ––––– AHP30B2A –5 0 –––– AHP36C2A 0 0 – – AHP48D2C ––––2 0 – AHP60D2C ––––2 0 – AV24B2A 0 0 ––––– AV36C2A ––0 0 ––– AV48D2C ––––0 0 – AV60D2C ––––0 0 – FC/MC/PC/UC18A3X 2A + 0 –––––– FC/MC/PC/UC18B3X 2A + 0 –––––– FC/MC/PC/UC24A3X 2A + 0 2A + 0 ––––– FC/MC/PC/UC24B3X 2A + 0 2A + 0 ––––– FC/MC/PC/UC30A3X –2A + 0 ––––– FC/MC/PC/UC30B3X –2A + 0 ––––– FC/MC/PC/UC32A3X –2A + 5 2A + 0 –––– FC/MC/PC/UC35B3X –2A + 5 2A + 0 –––– FC/MC/PC/UC35C3X –2A + 5 2A + 0 –––– FC/MC/PC/UC37A3X 2A + 0 2A + 0 – FC/MC/PC/UC43B3X 2A + 0 2A + 0 – FC/MC/PC/UC43C3X 2A + 0 2A + 0 – FC/MC/PC/UC48C3X 2A + 3 2C + 0 – FC/MC/PC/UC48D3X 2A + 3 2C + 0 – FC/PC/UC60C3X 2A + 5 2C + 2 2C + 0 – FC/MC/PC/UC60D3X 2A + 5 2C + 2 2C + 0 – FC/PC62D3X –––––2C + 2 2C + 0 For Notes See Page 4.
Johnson Controls Unitary Products 3
365147-YTG-C-0608
Additional R-22 Charge / Orifice Size for Various Matched Systems (Continued)
Outdoor Unit
Required Orifice or TXV
THGD18
S21S1
1
1TVM2A1 1TVM2A1 1TVM2A1 1TVM2A1 1TVM2C1 1TVM2C1 1TVM2C1
Factory Charge, lbs-oz 7 - 3 7 - 7 8 - 12 9 - 1 11 - 14 13 - 4 15 - 5
THGD24
S21S1
THGD30
S21S1
THGD36
S21S1
THGD42
S21S1
THGD48
S21S1
THGD60
S21S1
Indoor Coil
2,3
Additional Charge, Oz
HC18A3X 2A + 0 –––––– HC30A3X –2A + 0 ––––– HC36B3X –2A + 5 2A + 0 –––– HC42C3X 2A + 0 2A + 0 – HC60C3X 2A + 5 2C + 2 2C + 0 – HD24A3X –2A + 4 ––––– HD36B3X ––2A + 0 –––– HD48C3X 2A + 3 – HD60D3X 2A + 5 2C + 2 2C + 0 – MH24S59 –2A + 6 2A + 0 –––– MH30S65 –2A + 6 2A + 0 –––– AHP18B3X 2A + 0 –––––– AHP24B3X 2A + 0 2A + 0 ––––– AHP30B3X –2A + 5 2A + 0 –––– AHP36C3X 2A + 0 2A + 0 – AHP42C3X 2A + 0 – AHP48D3X ––––2C + 2 2C + 0 – AHP60D3X 2A + 5 2C + 2 2C + 0 – AV24B2A 2A + 0 2A + 0 ––––– AV36C2A 2A + 0 2A + 0 – AV48D2C 2A + 0 2C + 0 2C + 0 – AV60D2C ––––2C + 0 2C + 0 – F4FP024 0 –––––– F4FP030 –0 ––––– F4FP040 ––0 –––– F5FP045 2A + 5 2 – F5FP048 2A + 3 0 – F5FP060 2A + 5 2 0 – F4FV060 2A + 0 0 0
FOOTNOTES:
1.For applications requiring a TXV use 1TVM series kit.
2.Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.
3.PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of inter­connecting line tubing.
2. Verify the TXV or orifice and additional charge required for specific evaporator coil in the system using the above table.
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.
4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set.
4 Johnson Controls Unitary Products
365147-YTG-C-0608
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
THGD18S21S1
THGD24S21S1
THGD30S21S1
THGD36S21S1
THGD42S21S1
THGD48S21S1
THGD60S21S1 MA20D 24 FC/MC62D 1800 55.0 40.0 13.00 11.00
THGD18S21S1
THGD24S21S1
THGD30S21S1
THGD36S21S1
THGD42S21S1
THGD48S21S1
THGD60S21S1 MV20D 24 FC/MC62D 1800 55.0 40.5 13.50 11.00
For Notes See Page 6.
AIR HANDLER
MODEL W
MA08B 17 FC/MC18B 600 18.0 12.9 13.00 11.00 MA08B 17 FC/MC24B 600 18.0 12.9 13.00 11.00 MA08B 17 FC/MC30B 600 18.0 12.9 13.00 11.00 MA08B 17 FC/MC24B 800 23.0 16.8 13.00 11.00 MA08B 17 FC/MC30B 800 23.0 16.8 13.00 11.00 MA08B 17 FC/MC35B 800 23.0 16.8 13.00 11.00 MA12B 17 FC/MC35B 1000 29.0 21.2 13.00 11.00 MA12B 17 FC/MC43B 1000 29.0 21.2 13.00 11.00 MA12B 17 FC/MC43B 1200 35.0 25.6 13.00 11.00 MA14D 24 FC/MC48D 1200 35.0 25.6 13.00 11.00 MA14D 24 FC/MC60D 1200 35.0 25.6 13.00 11.00 MA14D 24 FC/MC48D 1400 40.0 28.8 13.00 11.00 MA16C 21 FC/MC48C 1400 40.0 28.8 13.00 11.00 MA14D 24 FC/MC60D 1400 40.0 28.8 13.00 11.00 MA16C 21 FC60C 1400 40.0 28.8 13.00 11.00 MA16C 21 FC60C 1600 45.0 33.2 13.00 11.00 MA20D 24 FC/MC60D 1600 45.0 33.2 13.00 11.00 MA20D 24 FC/MC62D 1600 45.0 33.2 13.00 11.00
13 SEER HP WITH MV - VARIABLE SPEED
MV12B 17 FC/MC18B 600 18.0 13.3 14.00 12.00 MV12B 17 FC/MC24B 600 18.0 13.4 14.00 12.00 MV12B 17 FC/MC30B 600 18.0 13.4 14.00 12.00 MV12B 17 FC/MC24B 800 23.0 17.4 14.00 12.00 MV12B 17 FC/MC30B 800 23.0 17.4 14.00 12.00 MV12B 17 FC/MC35B 800 23.0 17.4 14.00 12.00 MV12B 17 FC/MC35B 1000 29.0 21.8 14.00 12.00 MV16C 21 FC/MC35C 1000 29.0 22.0 14.00 12.00 MV12B 17 FC/MC43B 1000 29.0 21.8 14.00 12.00 MV16C 21 FC/MC43C 1000 29.0 22.0 14.00 12.00 MV12B 17 FC/MC43B 1200 35.0 26.2 14.00 12.00 MV16C 21 FC/MC43C 1200 35.0 26.4 14.00 12.00 MV16C 21 FC/MC48C 1200 35.0 26.4 14.00 12.00 MV16C 21 FC60C 1200 35.0 26.4 14.00 12.00 MV12D 24 FC/MC48D 1200 35.0 26.4 14.00 12.00 MV12D 24 FC/MC60D 1200 35.0 26.4 14.00 12.00 MV16C 21 FC/MC48C 1400 41.0 29.4 13.85 11.00 MV16C 21 FC/MC48C 1400 41.0 29.4 13.85 11.00 MV20D 24 FC/MC48D 1400 41.0 29.4 13.85 11.00 MV20D 24 FC/MC60D 1400 41.0 29.4 13.85 11.00 MV16C 21 FC60C 1200 45.0 33.2 13.25 11.00 MV20D 24 FC/MC60D 1600 46.0 33.8 13.25 11.00 MV20D 24 FC/MC62D 1600 45.0 33.6 13.30 11.00
COIL
1
MODEL
13 SEER HP WITH MA
RATED
CFM
TOTAL SENS.
COOLING
NET MBH
SEER EER
Johnson Controls Unitary Products 5
365147-YTG-C-0608
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
MODEL W
COIL
MODEL
1
RATED
CFM
TOTAL SENS.
13 SEER HP WITH AV / SV / F*FV - VARIABLE SPEED
THGD18S21S1 AV24 17 – 565 18.0 13.4 14.00 12.00 THGD24S21S1 AV24 17 – 770 23.0 17.5 14.00 12.00 THGD30S21S1 AV36 21 – 1015 29.0 22.0 14.00 12.00
THGD36S21S1
AV36 21 – 1270 35.0 26.2 14.00 12.00 AV/SV48 24 1270 35.0 26.2 14.00 12.00 AV/SV48 24 1415 41.0 29.4 13.85 11.00
THGD42S21S1
AV/SV60 24 1410 41.0 29.4 13.85 11.00 F4FV060 24 1410 41.0 29.4 13.85 11.00 AV/SV48 24 1610 46.0 33.8 13.25 11.00
THGD48S21S1
AV/SV60 24 1655 46.0 33.6 13.25 11.00 F4FV060 24 1655 46.0 33.6 13.30 11.00
13 SEER HP WITH AHP / SHP / F*FP
AHP18 17 – 650 18.0 12.9 13.00 11.00
THGD18S21S1
AHP24 17 – 655 18.0 13.0 13.00 11.00
F4FP024 17 655 18.0 13.0 13.00 11.00
AHP24 17 – 830 23.0 16.9 13.00 11.00
THGD24S21S1
AHP30 17 – 795 23.0 16.8 13.00 11.00
F4FP030 17 795 23.0 16.8 13.00 11.00
AHP30 17 – 1015 29.0 21.2 13.00 11.00
THGD30S21S1
AHP36 21 – 1040 29.0 21.2 13.00 11.00
F4FP040 21 1040 29.0 21.2 13.00 11.00
AHP36 21 – 1235 35.0 25.6 13.00 11.00 AHP42 21 – 1255 35.0 25.6 13.00 11.00
THGD36S21S1
AHP/SHP60 24 1270 35.0 26.2 14.00 12.00
F4FP045 24 1200 35.0 25.6 13.00 11.00 F5FP048 24 1200 35.0 26.2 14.00 12.00 F5FP060 24 1200 35.0 26.2 14.00 12.00
AHP/SHP48 24 1400 40.0 29.0 13.00 11.00 AHP/SHP60 24 1400 41.0 29.4 13.85 11.00
THGD42S21S1
F4FP045 24 1400 40.0 29.0 13.00 11.00 F5FP048 24 1400 41.0 29.4 13.85 11.00 F5FP060 24 1400 41.0 29.4 13.85 11.00
AHP/SHP48 24 1600 45.0 33.2 13.00 11.00
THGD48S21S1
AHP/SHP60 24 1600 46.0 33.6 13.30 11.00
F5FP060 24 1600 46.0 33.6 13.30 11.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow. EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outd oor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.
COOLING
NET MBH
SEER EER
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number. — = Not applicable.
6 Johnson Controls Unitary Products
365147-YTG-C-0608
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
FURNACE**
UNIT MODEL
THGD18S21S1
THGD24S21S1
THGD30S21S1
THGD36S21S1
THGD42S21S1
THGD48S21S1
THGD60S21S1 1600 - 2000 24 FC/MC62 1800 55.0 40.0 13.00 11.00
1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up.
CFM RANGE
(Min.-max.)
450 - 750 14,17 FC/MC/PC/UC18 600 18.0 12.9 13.00 11.00 450 - 750 14,17 FC/MC/PC/UC24 600 18.0 12.9 13.00 11.00 450 - 750 14,17 FC/MC/PC/UC30 600 18.0 12.9 13.00 11.00
450 - 750 14 HC18 600 18.0 12.9 13.00 11.00 600 - 1000 14,17 FC/MC/PC/UC24 800 23.0 16.8 13.00 11.00 600 - 1000 14,17 FC/MC/PC/UC30 800 23.0 16.8 13.00 11.00 600 - 1000 14 FC/MC/PC/UC32 800 23.0 16.8 13.00 11.00 600 - 1000 17,21 FC/MC/PC/UC35 800 23.0 16.8 13.00 11.00 600 - 1000 14 HC30 800 23.0 16.8 13.00 11.00 600 - 1000 17 HC36 800 23.0 16.8 13.00 11.00 600 - 1000 HD24 800 23.0 16.8 13.00 11.00 600 - 1000 19 MH24S 800 23.0 16.8 13.00 11.00 600 - 1000 19 MH30S 800 23.0 16.8 13.00 11.00 800 - 1200 14 FC/MC/PC/UC32 1000 29.0 21.2 13.00 11.00 800 - 1200 17,21 FC/MC/PC/UC35 1000 29.0 21.2 13.00 11.00 800 - 1200 14 FC/MC/PC/UC37 1000 29.0 21.2 13.00 11.00 800 - 1200 17,21 FC/MC/PC/UC43 1000 29.0 21.2 13.00 11.00 800 - 1200 17 HC36 1000 29.0 21.2 13.00 11.00 800 - 1200 21 HC42 1000 29.0 21.2 13.00 11.00 800 - 1200 HD36 1000 29.0 21.2 13.00 11.00 800 - 1200 19 MH24S 1000 29.0 21.2 13.00 11.00 800 - 1200 19 MH30S 1000 29.0 21.2 13.00 11.00
1000 - 1400 14 FC/MC/PC/UC37 1200 35.0 25.6 13.00 11.00 1000 - 1400 17,21 FC/MC/PC/UC43 1200 35.0 25.6 13.00 11.00 1000 - 1400 21,24 FC/MC/PC/UC48 1200 35.0 25.6 13.00 11.00 1000 - 1400 21,24 FC/MC/PC/UC60 1200 35.0 25.6 13.00 11.00 1000 - 1400 21 HC42 1200 35.0 25.6 13.00 11.00 1000 - 1400 24 HC60 1200 35.0 25.6 13.00 11.00 1000 - 1400 HD48 1200 35.0 25.6 13.00 11.00 1000 - 1400 HD60 1200 35.0 25.6 13.00 11.00 1200 - 1600 21,24 FC/MC/PC/UC48 1400 40.0 28.8 13.00 11.00 1200 - 1600 21,24 FC/MC/PC/UC60 1400 40.0 28.8 13.00 11.00 1200 - 1600 24 HC60 1400 40.0 28.8 13.00 11.00 1200 - 1600 HD60 1400 40.0 28.8 13.00 11.00 1400 - 1800 21,24 FC/MC/PC/UC60 1600 45.0 33.2 13.00 11.00 1400 - 1800 24 FC/MC62 1600 45.0 33.2 13.00 11.00 1400 - 1800 24 HC60 1600 45.0 33.2 13.00 11.00 1400 - 1800 HD60 1600 45.0 33.2 13.00 11.00
W
COIL
MODEL
RATED
CFM
TOTAL SENS.
COOLING
NET MBH
SEER
1
EER
Johnson Controls Unitary Products 7
365147-YTG-C-0608
COOLING CAPACITY - With Variable Speed Furnaces
UNIT MODEL
THGD18S21S1
THGD24S21S1
THGD30S21S1
For Notes See Page 9.
VARIABLE SPEED
FURNACE MODEL
13 SEER HP WITH VARIABLE SPEED FURNACES
PV8*A12 FC/MC/PC/UC18A 14 600 18.0 13.4 14.00 12.00 PV9*A12 FC/MC/PC/UC18A 14 600 18.0 13.3 14.00 12.00
P(C,V)9*B12 FC/MC/PC/UC18B 17 600 18.0 13.4 14.00 12.00
PV8*A12 FC/MC/PC/UC24A 14 600 18.0 13.4 14.00 12.00 PV9*A12 FC/MC/PC/UC24A 14 600 18.0 13.3 14.00 12.00
P(C,V)9*B12 FC/MC/PC/UC24B 17 600 18.0 13.4 14.00 12.00
PV8*A12 FC/MC/PC/UC30A 14 600 18.0 13.4 14.00 12.00 PV9*A12 FC/MC/PC/UC30A 14 600 18.0 13.3 14.00 12.00
P(C,V)9*B12 FC/MC/PC/UC30B 17 600 18.0 13.4 14.00 12.00
PV8*A12 HC18 14 600 18.0 13.4 14.00 12.00 PV9*A12 HC18 14 600 18.0 13.3 14.00 12.00 PV8*A12 FC/MC/PC/UC24A 14 800 23.0 17.3 14.00 12.00 PV9*A12 FC/MC/PC/UC24A 14 800 23.0 17.3 14.00 12.00
P(C,V)9*B12 FC/MC/PC/UC24B 17 800 23.0 17.3 14.00 12.00
PV8*A12 FC/MC/PC/UC30A 14 800 23.0 17.3 14.00 12.00 PV9*A12 FC/MC/PC/UC30A 14 800 23.0 17.3 14.00 12.00
P(C,V)9*B12 FC/MC/PC/UC30B 17 800 23.0 17.3 14.00 12.00
PV8*A12 FC/MC/PC/UC32A 14 800 23.0 17.3 14.00 12.00 PV9*A12 FC/MC/PC/UC32A 14 800 23.0 17.3 14.00 12.00
P(C,V)9*B12 FC/MC/PC/UC35B 17 800 23.0 17.3 14.00 12.00
PV8*A12 HC30 14 800 23.0 17.3 14.00 12.00 PV9*A12 HC30 14 800 23.0 17.3 14.00 12.00
P(C,V)9*B12 HC36 17 800 23.0 17.3 14.00 12.00
PV8*A12 FC/MC/PC/UC32A 14 1000 29.0 21.6 14.00 12.00 PV9*A12 FC/MC/PC/UC32A 14 1000 29.0 21.6 14.00 12.00 PV8*B16 FC/MC/PC/UC35B 17 1000 29.0 22.0 14.00 12.00 PV8*C16 FC/MC/PC/UC35C 21 1000 29.0 22.0 14.00 12.00 PV8*C20 FC/MC/PC/UC35C 21 1120 29.0 21.6 14.00 12.00
P(C,V)9*B12 FC/MC/PC/UC35B 17 1000 29.0 21.6 14.00 12.00
P(C,V)9*C16 FC/MC/PC/UC35C 21 1010 29.0 21.8 14.00 12.00
PV8*A12 FC/MC/PC/UC37A 14 1000 29.0 21.6 14.00 12.00 PV9*A12 FC/MC/PC/UC37A 14 1000 29.0 21.6 14.00 12.00 PV8*B16 FC/MC/PC/UC43B 17 1000 29.0 22.0 14.00 12.00 PV8*C16 FC/MC/PC/UC43C 21 1000 29.0 22.0 14.00 12.00 PV8*C20 FC/MC/PC/UC43C 21 1120 29.0 21.6 14.00 12.00
P(C,V)9*B12 FC/MC/PC/UC43B 17 1000 29.0 21.6 14.00 12.00
P(C,V)9*C16 FC/MC/PC/UC43C 21 1010 29.0 21.8 14.00 12.00
PV8*B16 HC36 17 1000 29.0 22.0 14.00 12.00
P(C,V)9*B12 HC36 17 1000 29.0 21.6 14.00 12.00
PV8*C16 HC42 21 1000 29.0 22.0 14.00 12.00 PV8*C20 HC42 21 1120 29.0 21.6 14.00 12.00
P(C,V)9*C16 HC42 21 1010 29.0 21.8 14.00 12.00
COIL
MODEL
1
COOLING
W
RATED
CFM
Net MBH
TOTAL SENS.
2
SEER EER
8 Johnson Controls Unitary Products
COOLING CAP ACITY - With Variable Speed Furnaces (Continued)
UNIT MODEL
THGD36S21S1
THGD42S21S1
THGD48S21S1
THGD60S21S1
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Variable speed furnaces have B.O.D (Blower on Delay) standard.
VARIABLE SPEED
FURNACE MODEL
13 SEER HP WITH VARIABLE SPEED FURNACES
PV8*A12 FC/MC/PC/UC37A 14 1200 35.0 26.0 13.55 11.00 PV9*A12 FC/MC/PC/UC37A 14 1200 35.0 25.8 13.25 11.00
PV8*B16 FC/MC/PC/UC43B 17 1200 35.0 26.2 14.00 12.00 PV8*C16 FC/MC/PC/UC43C 21 1200 35.0 26.2 14.00 12.00 PV8*C20 FC/MC/PC/UC43C 21 1200 35.0 26.0 13.85 12.00
P(C,V)9*B12 FC/MC/PC/UC43B 17 1200 35.0 26.0 13.70 12.00 P(C,V)9*C16 FC/MC/PC/UC43C 21 1175 35.0 26.2 14.00 12.00 P(C,V)9*C20 FC/MC/PC/UC43C 21 1200 35.0 26.2 14.00 12.00
PV8*C16 FC/MC/PC/UC48C 21 1200 35.0 26.4 14.00 12.00
PV8*C20 FC/MC/PC/UC48C 21 1200 35.0 26.0 13.90 12.00 P(C,V)9*C16 FC/MC/PC/UC48C 21 1175 35.0 26.2 14.00 12.00 P(C,V)9*C20 FC/MC/PC/UC48C 21 1200 35.0 26.2 14.00 12.00 P(C,V)9*D20 FC/MC/PC/UC48D 24 1200 35.0 26.2 14.00 12.00
PV8*C16 HC42 21 1200 35.0 26.2 14.00 12.00
PV8*C20 HC42 21 1200 35.0 26.0 13.90 12.00 P(C,V)9*C16 HC42 21 1175 35.0 26.2 14.00 12.00 P(C,V)9*C20 HC42 21 1200 35.0 26.2 14.00 12.00
PV8*C16 FC/MC/PC/UC48C 21 1400 40.0 29.2 13.45 11.00
PV8*C20 FC/MC/PC/UC48C 21 1400 41.0 29.2 13.55 11.00 P(C,V)9*C16 FC/MC/PC/UC48C 21 1415 40.0 29.0 13.25 11.00 P(C,V)9*C20 FC/MC/PC/UC48C 21 1400 40.0 29.2 13.45 11.00 P(C,V)9*D20 FC/MC/PC/UC48D 24 1400 40.0 29.0 13.35 11.00
PV8*C16 FC/PC/UC60C 21 1400 41.0 29.2 13.45 11.00
PV8*C20 FC/PC/UC60C 21 1400 41.0 29.2 13.60 11.00 P(C,V)9*C16 FC/PC/UC60C 21 1415 40.0 29.0 13.25 11.00 P(C,V)9*C20 FC/PC/UC60C 21 1400 41.0 29.2 13.45 11.00 P(C,V)9*D20 FC/MC/PC/UC60D 24 1400 40.0 29.0 13.40 11.00
PV8*C16 FC/PC/UC60C 21 1500 45.0 33.4 13.25 11.00
PV8*C20 FC/PC/UC60C 21 1610 45.0 33.4 13.25 11.00 P(C,V)9*C16 FC/PC/UC60C 21 1600 45.0 33.2 13.25 11.00 P(C,V)9*C20 FC/PC/UC60C 21 1600 45.0 33.4 13.25 11.00 P(C,V)9*D20 FC/MC/PC/UC60D 24 1600 45.0 33.4 13.25 11.00
PV8*C20 FC/MC62D 24 1610 45.0 33.4 13.25 11.00 P(C,V)9*C20 FC/MC62D 24 1600 45.0 33.4 13.25 11.00 P(C,V)9*D20 FC/MC62D 24 1600 45.0 33.4 13.25 11.00
PV8*C20 FC/MC62D 24 1730 55.0 40.0 13.50 11.00 P(C,V)9*C20 FC/MC62D 24 1620 54.0 40.5 13.50 11.00 P(C,V)9*D20 FC/MC62D 24 1620 54.0 40.5 13.50 11.00
COIL
MODEL
1
W
RATED
CFM
TOTAL SENS.
2
COOLING
Net MBH
365147-YTG-C-0608
SEER EER
Johnson Controls Unitary Products 9