DESCRIPTION
The Affinity Air Handler line offers the ultimate in comfort, sound
and application flexibility. The Affinity models utilize a whisper
quiet variable speed motor that provides humidity control and
the lowest operating cost in the industry. The AVY air handler is
shipped ready to be installed in all positions, upflow, downflow,
horizontal left or right, with minor adjustments. The SVY 48 &
60 models are upflow only models designed into a shorter cabinet, for those special applications where reduced height is
required. No special kits are required to install this deluxe product in any position.
All JCI Unitary Products air handlers and coils use a TXV to provide our customers with the optimum performance and refrigerant control required for 13 + Seer systems. Air handlers can be
ordered with either a R-22 or R-410A TXV factory installed. Air
handlers are also available with “Flex-coils” without a factory
installed metering device, where for added flexibility, a R-22 or
R-410A TXV can be field installed to meet your refrigerant
choice.
FEATURE
Thermal Expansion Valve - Provides the ultimate refrigerant
control required for today’s high efficient product. The UPG bolton TXV provides easy installation to convert the air handler to
the required refrigerant, which is a true bolt-on design that does
not require brazing to replace or install.
MicroBlue
with the MicroBlue
removal of condensate during the refrigeration cycle and
reduce the possibility of water blow-off. The MicroBlueTM coating also reduces the growth of germ causing microbes for a
healthier home environment.
Insulated Cabinet - All air handler cabinets are thermally insulated with 1” foil faced insulation (R-4.2) to prev ent sweating.
For applications in extreme humidity conditions an optional,
field installed, external insulating wrap kit is also available.
Factory - Sealed to achieve 2% or less leakage rate with or without field installed filter at 1.0” water gauge external static pressure.
Durable Finish Inside and Out - Air handler casings are made
of pre-painted galvanized steel which provides a better paint to
steel bond that resists corrosion and rust creep. All internal coil
sheet metal parts are made of G90 galvanized.
New 4 HK Heat Kit - Installation friendly, easy service, more
robust, unique to new design.
ECM Variable Speed M otor - Designed for efficient, quiet operation with added indoor comfort control. With the use of a humidistat, the motor will monitor the humidity in the home and
automatically keep the desired humidity level in both winter and
summer seasons. The ECM motor utilizes only 24% of the
energy used by standard blower motors to reduce your overall
heating and cooling costs.
ClimaTrak Comfort Settings - Installers can set an operating
cycle for the ECM motor that works best in a particular climate.
Homeowners benefit from an operating cycle that maximizes
their indoor comfort level regardless of whether they live in a
dry, temperate, or humid climate.
TM
Coated Fins - All air handler coils are treated
TM
hydrophilic coating to enhance the
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
1. Actual size (Conduit size).
** Thermal expansion device indicators - “2_” indicates R-22 TXV is factory installed, “3X” indicates unit is a “Flex Coil” models with a field installed
R-22 or R-410A TXV, and “4_” indicates R-410A TXV is factory installed. Letter indicates TXV size as required, see outdoor unit technical information for proper matches and requirements.
HighLowHighLowCOOL TapADJ Tap
1088 707 1387 905 A B
830 542 1151 753 B B
948 617 1201 783 A A
716 465 1009 657 B A
854 556 1086 703 A C
612 462 953 622 C B
637 460 901 588 B C
531 460 754 493 D B
542 462 831 540 C A
462 462 657 460 D A
474 460 751 494 C C
461 464 588 461 D C
48D60DJUMPER SETTINGS
HighLowHighLowCOOL TapADJ Tap
2138 1442 2364 1545 A B
1759 1162 1962 1271 B B
2009 1311 2123 1374 A A
1612 1052 1763 1146 B A
1773 1166 1905 1237 A C
1530 989 1777 1158 C B
1459 947 1580 1021 B C
1359 886 1596 1030 D B
1388 904 1583 1019 C A
1221 806 1413 929 D A
1244 808 1412 926 C C
1118 715 1277 841 D C
HIGH / LOW SPEED COOLING AND HEAT PUMP AIRFLOW
CFM
JUMPER SETTINGS
HIGH / LOW SPEED ELECTRIC HEAT AIRFLOW
CFM
24B36C
HighLowHighLowHEAT TapADJ Tap
1088 828 1387 908 A N / A
954 714 1228 804 B N / A
829 614 1151 756 C N / A
678 523923 609 D N / A
48D60DJUMPER SETTINGS
HighLowHighLowHEAT TapADJ Tap
2111 1417 2363 1488 A N / A
1858 1252 2174 1252 B N / A
1480 985 1868 1061 C N / A
1250 840 1387 823 D N / A
1. Airflow at nominal voltage, bottom return at 0.5 external static pressure, tested without filter installed, dry coil conditions.
2. These units have variable speed motors that automatically adjust to provide constant CFM from 0.0” to 0.6” w.c. static pressure.
3. From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static.
4. Operation on duct systems with greater than 1.0” w.c. external static pressure is not recommended.
5. Both the COOL and the ADJUST tap must be set to obtain the cooling airflow desired (CFM).
6. The ADJ tap does not affect the HEAT tap setting.
7. Fan only airflow (CFM) = 63% of jumper selected COOL tap and ADJUST tap.
8. Low speed cooling used only with two stage outdoor units. (Speed is preset to 65% of high speed).
9. Dehumidification speed is 85% of jumper selected COOL tap and ADJUST tap.
10. When operating in both heat pump and electric heat modes, the airflow (CFM) will be per HEAT Tap CFM values only.
11. At some settings, LOW COOL and/or LOW HEAT airflow may be lower than what is required to operate an airflow switch on certain
models of electronic air cleaners. Consult the instructions for the electronic air cleaner for further details.
12. Airflow (CFM) indicator light (LED2) flashes once for every 100 CFM (i.e.: 12 Flashes is 1200 CFM) – blinks are approximate +/- 10%.
JUMPER SETTINGS
4Johnson Controls Unitary Products
Page 5
APPLICATION FACTORS - RATED CFM VS. ACTUAL CFM
% Of Rated Airflow
Capacity Factor
80%90%Rated CFM110%120%
0.960.981.001.021.03
PHYSICAL & ELECTRICAL DATA - COOLING ONLY (60 Hz)
256819-YTG-J-1208
Models
Blower - Diameter x Width10 x 710 x 710 x 1010 x 10
Motor
Voltage230
AmpsFull Load (230)2.84.35.57.0
1
Filter
Shipping / Operating Weight (lbs.)140/134170/164
1.Field supplied.
HP1/31/23/41
Nominal RPM1200120012001200
TypeDISPOSABLE OR PERMANENT
Size16 x 20 x120 x 20 x122 x 20 x122 x 20 x1
Permanent Type Kit1PF0601BK1PF0602BK1PF0603BK1PF0603BK
Refer to Price Manual for specific model numbers where not
shown.
TXV Kits - TXV kits are available for “Flex-coil” applications and
converting R-22 to R-410A or as a service replacement. All kits
are bolt-on and require no brazing to install.
Electric Heaters - 4HK models shown under electrical data
include sequential operation and temperature dual limit
switches for safe, efficient oper ation. Circuit breakers are provided where shown.
External Insulating Wrap Kit - Provides a vinyl covered thermal insulation wrap, providing additional thermal insulation protection to prevent sweating in applications where extreme high
humidity is present. Air Handler cover (or wrap) has Velcro
edges for easy installation and access.
Humidstat - S1-2HU16700124
Control when used with ECM variable speed models will moni-
tor humidity level in both winter and summer seasons. Adjusts
blower speed and airflow provided to maintain desired humidity
levels.
LIMITATIONS
These units must be wired and installed in accordance with all
national and local safety codes.
Voltage limits are as follows:
1
Air Handler VoltageVoltage code
208/230-1-6006187-253
1.Rated in accordance with ARI Standard 110, utilization range
“A”.
Airflow must be within the minimum and maximum limits
approved for electric heat, evaporator coils and outdoor units.
Entering Air Temperature Limits
Wet Bulb Temp.°FDry Bulb Temp. °F
Min.Max.Min.Max.
57726595
Normal Operating
Voltage Range
COOLING MODELS WITH ELECTRIC HEAT WIRING
Air Handler Control Wiring
Typical A/C - Cooling only Applications
THERMOSTAT
RR
G
Y
W1
W2
C
* Optional dehumidification humidistat switch contacts open on humidity rise.
NOTES:
1. “Y/Y2” Terminal on air handler control board must be connected for full CFM and applications requiring 60 second blower off delay for
SEER enhancement.
2. Remove humidistat jumper on air handler control board.
3. For heat pump applications - set MODE jumper on air handler control board to the HP position.
4. To change quantity of heat during HP defrost cycle - reverse connections at W1 and W2 on air handler control board.
AIR HANDLER
BOARD
G
Y/Y2
Y1
W2
W1
O
HUM
X/L
COM
1-STAGE
AIR CONDITIONING
Y
HUMIDISTAT
C
THERMOSTAT
*
Typical A/C with Electric Heat Applications
RR
G
Y
W2
W1
C
Air Handler Control Wiring
AIR HANDLER
BOARD
G
Y/Y2
Y1
W2
W1
O
HUM
X/L
COM
1-STAGE
AIR CONDITIONING
Y
HUMIDISTAT
C
*
Johnson Controls Unitary Products9
Page 10
TWO-STAGE COOLING WIRING
CONTROL WIRING - Air Handler & New UPG HP Systems
Two Stage H/P with York Guard VI Board & Copeland “Ultra Tech”
THERMOSTAT
RRR
GG
Y2
Y1
E
W
OO
X/LX/LX/L
C
* Optional dehumidification humidistat switch contacts open on humidity rise.
NOTES:
1. “Y/Y2” Terminal on air handler control board must be connected for full CFM and applications requiring 60 second blower off delay for SEER
enhancement.
2. Remove humidistat jumper on air handler control board.
3. For heat pump applications - set MODE jumper on air handler control board to the HP position.
4. To change quantity of heat during HP defrost cycle - reverse connections at W1 and W2 on air handler control board.