York PT9 User Manual

Page 1
TECHNICAL GUIDE
AFFINITY MODELS: PT9
GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES
UP TO 94% AFUE
NATURAL GAS 40 - 120 MBH INPUT
EFFICIENCY RATING CERTIFIED
This product was manufactured in a plant whose quality system is certified/registered as being in conformity with ISO 9001.
Due to continuous product improvement, specific ations are subject to change without notice.
Visit us on the web at www.york.com for the most up-to-date technical information.
Additional rating information can be found at www.gamanet.org.
036-21581-001 Rev. B (0904)
DESCRIPTION
These Category IV, highly efficient, compact, condensing type furnaces are designed for residential and commercial installations in a basement, closet, alcove, recreation room or garage where the ambient temperature is above 32°F, or higher. They may be either side wall or thru-roof vented using approved plastic type combustion air and vent piping. All units are factory assembled, wired and tested to assure dependable and economical installation and operation.
WARRANTY
Lifetime limited warranty on both heat exchangers to the original purchaser; a 20-year limited warranty from original installation date to subsequent purchaser.
10-year warranty on commercial applications. 5-year limited parts warranty.
FEATURES
Two stage heating operation includes:
- Two stage gas valve
- Two stage inducer operation
Provides increased comfort level & very quiet unit oper­ation
Adjustable delay timer allows two stage operation with single stage thermostat
• Compact, easy to install, ideal height 40" cabinet
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement applica-
tion.
• Integrated control module for reliable, economical opera-
tion.
• High velocity filter and side -return filter rack provided for
easy field installation.
• May be installed as either two-pipe (sealed combustion)
or single pipe vent (using indoor combustion air)
• Top intake & vent connection allows installation in narrow
locations.
• Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
• Induced combustion system with inshot main burners for
quiet, efficient operation.
• No special vent termination kit required.
• 100% shut off main gas valve for extra safety.
• PSC -four speed, direct drive motor with large, quiet
blower.
• 24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
• Hi-tech tubular aluminized steel primary heat exchanger.
• Secondary (condensing) heat exchanger of 29-4C high-
grade stainless steel.
• Timed on, adjustable off blower capability for maximum
comfort.
• Solid removable bottom panel allows easy application.
• Easy access from front of unit for cleaning, maintenance
or service.
• Protection from intake, exhaust or condensate blockage.
• Insulated blower compartment for quiet operation.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
Page 2
036-21581-001 Rev. B (0904)
26-1/2 24-5/8
1-1/2” GAS PIPE ENTRY
7/8” JUNCTION BOX HOLE
T-STAT WIRING 7/8” K.O.
CONDENSAATE DRAIN 7/8” K.O.
OPTIONAL RETURN AIR CUT-OUT (either side) FOR USE WITH EXTERNAL FILTER FRAME
7/8
LEFT SIDE
23-3/4
30-1/8
11
7
21-1/2
13-7/8
7/8
26-3/4
BOTTOM IMAGE
RETURN END
30-7/8
FRONT
1-3/8
C
A
1-1/4
1-3/4
40
28-3/8
21-1/2
11
8
24-3/8
20
D
26-1/2
TOP IMAGE
SUPPLY END
5/8
5/8
B
26-1/2
25-3/8
1-1/2” GAS PIPE ENTRY
7/8” JUNCTION BOX HOLE
T-STAT WIRING 7/8” K.O.
CONDENSAATE DRAIN 7/8” K.O.
RIGHT SIDE
DIMENSIONS
BTUH
Input/Output
CFM
Cabinet
Size
A (in.) B (in.) C (in.) D (in.)
PT9A12N040UP11 1200 A 14-1/2 13-1/4 12-1/8 6-1/4 PT9B12N060UP11 1200 B 17-1/2 16-1/4 15-1/8 8-1/2 PT9B12N080UP11 1200 B 17-1/2 16-1/4 15-1/8 8-1/2 PT9C16N080UP11 1600 C 21 19-3/4 18-1/2 8-7/8 PT9C16N100UP11 1600 C 21 19-3/4 18-1/2 8-7/8 PT9C20N100UP11 2000 C 21 19-3/4 18-1/2 8-7/8 PT9D20N120UP11 2000 D 24-1/2 23-1/4 21-7/8 10-5/8
.
Cabinet Dimension
COMBUSTION AIR SUPPLY AND VENT PIPING
MAXIMUM ELBOWS AND VENT LENGTHS
Models Input
BTUH
Pipe Size
Inches
1 2 3 4 5 6 7 8
Maximum Number of Elbows*
Minimum
Length
40,000 1-1/2 30 25 20 10 N/A N/A N/A N/A 5 40,000 2 7065605550453525 5 60,000 1-1/2 30 25 20 10 N/A N/A N/A N/A 5 60,000 2 60 55 50 45 40 30 20 10 5 60,000 3 85 80 75 70 65 60 50 40 20 80,000 1-1/2 20 15 N/A N/A N/A N/A N/A N/A 5 80,000 2 60 55 50 45 40 30 20 10 5
80,000 3 85 80 75 70 65 60 50 40 20 100,000 2 25 20 15 N/A N/A N/A N/A N/A 5 100,000 3 85 80 75 70 65 60 50 40 20 120,000 3 75 70 65 60 55 45 35 25 5
Three elbows (two in vent pipe and one in the air intake pipe) are already accounted for and need not be included in the elbow count from the Table above.
2 Unitary Products Group
Page 3
HIGH ALTITUDE PRESSURE SWITCH APPLICATION
Input (MBH) High Altitude Pressure Switch Kit
Upflow Models 4,500 Ft to 10,000 Ft.
PT9A12N040UP11 1PS0506 PT9B12N060UP11 1PS0501 PT9B12N080UP11 1PS0502 PT9C16N080UP11 1PS0503 PT9C16N100UP11 1PS0503 PT9C20N100UP11 1PS0505 PT9D20N120UP11 1PS0503
NOTE: For high altitude conversion, an orifice change may also be required. See Form 035-14447-001 for applicat ion information.
ELECTRICAL AND PERFORMANCE DATA
036-21581-001 Rev. B (0904)
Input
Model
PT9A12N040UP11 40/26 38/24 1200 94.0 35-65 165 1/2 7.7 10x8 9 20 14 PT9B12N060UP11 60/39 56/36 1200 93.2 40-70 170 1/2 7.7 11x8 9 20 14 PT9B12N080UP11 80/52 75/49 1200 92.5 45-75 175 1/2 7.7 11x8 9 20 14 PT9C16N080UP11 80/52 75/49 1600 92.8 45-75 175 3/4 10.2 11x10 12 20 14 PT9C16N100UP11 100/65 93/61 1600 92.5 45-75 175 3/4 10.2 11x10 12 20 14 PT9C20N100UP11 100/65 93/61 2000 92.8 45-75 175 1 12.7 11x11 14 20 12 PT9D20N120UP11 120/78 112/74 2000 93.2 40-70 170 1 12.7 11x11 14 20 12
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water.
High/Low
MBH MBH CFM % °F °F HP Amps In. Amps
Output
High/Low
Nominal
Airflow
AFUE
Air Temp.
Rise
Max. Outlet
Air Temp.
Blower
Blower
Size
Total
Unit
Max.
Over-current
Protect
Min. Wire Size
(awg) @ 75 ft.
One Way
FILTER SIZES
Input / Output BTU/H CFM Cabinet Size Side Return Filter in. Bottom Return Filter in.
PT9A12N040UP 1200 A 16 x 25 14 x 25
PT9B12N060UP 1200 B 16 x 25 16 x 25 PT9B12N080UP11 1200 B 16 x 25 16 x 25 PT9C16N080UP11 1600 C 16 x 25 20 x 25 PT9C16N100UP11 1600 C 16 x 25 20 x 25 PT9C20N100UP11 2000 C 16 x 25 20 x 25 PT9D20N120UP11 2000 D (2) 16 x 25 22 x 25
* ESP (External Static Pressure) .5" WG is at furnace outlet ahead of cooling coil.
NOTES:
1. All filters must be high velocity cleanable type.
2. Air flows above 1800 CFM require either return from two sides or one side plus bottom.
Unitary Products Group 3
Page 4
036-21581-001 Rev. B (0904)
BLOWER PERFORMANCE CFM
AIRFLOW WITH BOTTOM OR ONE SIDE RETURN
MODELS
Input/
Airflow/cabinet
Speed
Tap
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM
HIGH 1395 1330 1265 1200 1120 1030 940 820 NR NR
PT9A12N040UP11
M-HI 1025 990 960 925 885 825 750 660 NR NR
M-LO 785 765 745 715 670 625 545 NR NR NR
LOW 640 605 590 565 530 465 405 NR NR NR
HIGH 1650 1605 1570 1525 1465 1410 1350 1275 1170 1060
PT9B12N060UP11 PT9B12N080UP11
M-HI 1165 1185 1175 1165 1150 1140 1100 1050 970 875
M-LO 895 915 935 940 940 920 905 860 815 750
LOW 710 725 725 725 720 700 685 660 625 560
HIGH 2300 2210 2120 2020 1930 1830 1715 1595 1480 1350
PT9C20N100UP11
M-HI 1950 1900 1830 1755 1680 1595 1500 1390 1270 1155
M-LO 1610 1545 1490 1440 1390 1315 1230 1155 1050 920
LOW 1325 1270 1225 1175 1105 1045 990 905 890 790
HIGH 1960 1955 1925 1890 1830 1765 1695 1615 1600 1485
PT9C16N080UP11 PT9C16N100UP11
M-HI 1565 1560 1560 1575 1545 1530 1475 1425 1365 1260
M-LO 1230 1275 1285 1300 1310 1300 1280 1245 1190 1070
LOW 930 945 965 975 975 975 975 950 910 850
HIGH 2560 2485 2410 2320 2220 2135 2035 1920 1785 1650
PT9D20N120UP11
M-HI 2090 2050 1990 1970 1885 1820 1760 1675 1545 1405
M-LO 1695 1675 1665 1615 1565 1510 1460 1385 1285 1140
LOW 1175 1150 1135 1110 1085 1055 1005 980 970 845
AIRFLOW WITH TWO SIDE RETURNS OR WITH BOTTOM AND ONE SIDE RETURN
MODELS
Input/
Airflow/cabinet
PT9C20N100UP11
PT9D20N120UP11
NOTES:
1. Airflow expressed in standard cubic feet per minute (CFM) and in cubic meters per minute (m
2. Return air is through side opposite motor (left side).
3. Airflows above 1800 CFM (50.97 m
4. Motor voltage at 115 V.
5. NR = Operation at this static pressure is not recommended.
Speed
Tap
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM
HIGH 2465 2380 2295 2195 2095 1995 1875 1760 1620 1470
M-HI 2085 2035 1960 1880 1800 1705 1605 1485 1360 1235
M-LO 1725 1625 1595 1540 1485 1405 1315 1235 1125 995
LOW 1420 1360 1310 1255 1180 1120 1070 970 950 845
HIGH 2615 2535 2450 2385 2285 2175 2075 1945 1825 1670
M-HI 2055 2045 2015 1985 1932 1855 1785 1730 1605 1470
M-LO 1690 1650 1620 1600 1570 1525 1470 1395 1300 1200
LOW 1345 1335 1335 1285 1250 1230 1180 1115 1010 850
3
/min) require either return from two sides or one side plus bottom.
EXTERNAL STATIC PRESSURE, INCHES W.C. (kPa)
EXTERNAL STATIC PRESSURE, INCHES W.C. (kPa)
3
/min).
BLK
WHT
GRN
BLK (HOT)
WHT (NEUTRAL)
GRN
NOMINAL 120 VOLT
LINE WIRING CONNECTIONS
ROOM THERMOSTAT
R W1 W2
G
Y1 Y2
C
TWO-STAGE HEATING AND TWO-STAGE COOLING
FURNACE CONTROL
R
W1/W
Y/Y2
TO AIR CONDITIONER CONTROLS
W2
G Y1
C
COMMON T’STAT CONNECTION
THERMOSTAT CONNECTIONS
CONDENSING UNIT
ROOM THERMOSTAT
R
W
G
Y
C
THERMOSTAT CONNECTIONS
ROOM THERMOSTAT
R W G
Y1 Y2
C
SINGLE STAGE HEATING AND TWO-STAGE COOLING
FURNACE CONTROL
R
W1/W
Y/Y2
TO AIR CONDITIONER CONTROLS
G
C
COMMON T’STAT CONNECTION
SINGLE STAGE HEATING
FURNACE CONTROL
R
W1/W
Y/Y2
TO AIR CONDITIONER CONTROLS
G
Y1
C COMMON T’STAT CONNECTION
THERMOSTAT CONNECTIONS
CONDENSING UNIT
CONDENSING UNIT
4 Unitary Products Group
Page 5
FILTER PERFORMANCE
The airflow capacity data published in the “Blower Perfor­mance” table listed above represents blower performance WITHOUT filters. To determine the approximate blower per­formance of the system, apply the filter drop value for the fil-
NOTE: The filter pressure drop values in the “Filter Perfor­mance” table shown below are typical values for the type of filter listed and should only be used as a guideline. Actual pressure drop ratings for each filter type vary between filter manufacturer.
ter being used or select an appropriate value from the “Filter Performance” table shown below.
FILTER PERFORMANCE - PRESSURE DROP INCHES W.C. AND (KPA)
036-21581-001 Rev. B (0904)
Airflow Range
0 - 750 230
751 - 1000 330 0.04 10 0.03 7.5 0.20 50 1001 - 1250 330 0.08 20 0.07 17 0.20 50 1251 - 1500 330 0.08 20 0.07 17 0.25 62 1501 - 1750 380 658 0.14 35 0.08 20 0.13 32 0.06 15 0.30 75 0.17 42 1751 - 2000 380 658 0.17 42 0.09 22 0.15 37 0.07 17 0.30 75 0.17 42
2001 & Above 463 658 0.17 42 0.09 22 0.15 37 0.07 17 0.30 75 0.17 42
APPLYING FILTER PRESSURE DROP TO DETERMINE SYSTEM AIRFLOW
To determine the approximate airflow of the unit with a filter in place, follow the steps below:
1. Select the filter type.
2. Select the number of return air openings or calculate the return opening size in square inches to determine the proper filter pressure drop.
3. Determine the External System Static Pressure (ESP) without the filter.
4. Select a filter pressure drop from the table based upon the number of return air openings or return air opening size and add to the ESP from Step 3 to determine the total system static.
5. If total system static matches a ESP value in the airflow table (i.e. 0.20, 0.60, etc,) the system airflow corre­sponds to the intersection of the ESP column and Model/ Blower Speed row .
6. If the total system static falls between ESP values in the table (i.e. 0.58, 0.75, etc.), the static pressure may be rounded to the nearest value in the table determining the
Minimum Opening
Size
1 Opening 2 Openings 1 Opening 2 Opening 1 Opening 2 Opening 1 Opening 2 Opening
Sq. in. Sq. in. In w.c. Pa In w.c. Pa In w.c. Pa In w.c. Pa In w.c. Pa In w.c. Pa
Disposable WASHABLE FIBER* Pleated
0.01 2.5 0.01 2.5 0.15 37
Example: For a 120,000 Btuh furnace with 2 return openings and operating on high speed blower, it is found that total sys­tem static is 0.58" w.c. To determine the system airflow, com­plete the following steps:
1. Obtain the airflow values at 0.50" & 0.60" ESP. Airflow @ 0.50": 2285 CFM Airflow @ 0.60": 2175 CFM
2. Subtract the airflow @ 0.50" from the airflow @ 0.60" to obtain airflow difference.
2175 - 2285 = -110 CFM
3. Subtract the total system static from 0.50" and divide this difference by the difference in ESP values in the table,
0.60" - 0.50", to obtain a percentage. (0.58 - 0.50) / (0.60 - 0.50) = 0.8
4. Multiply percentage by airflow difference to obtain airflow reduction.
(0.8) x (-110) = -88
5. Subract airflow reduction value to airflow @ 0.50" to obtain actual airflow @ 0.58" ESP.
2288 - 88 = 2197
Filter Type
airflow using Step 5 or calculate the airflow by using the following example.
Unitary Products Group 5
Page 6
036-21581-001 Rev. B (0904)
ACCESSORIES
PROPANE (LP) CONVERSION KIT ­1NP0580 - All units
This accessory conversion kit may be used to convert natural gas (N) units for propane (LP) operation. Conversions must be made by qualified distributor or dealer personnel.
CONCENTRIC VENT TERMINATION - 1CT0302 (2") 1CT0303 (3") For use through rooftop, sidewall. Allows combustion air to
enter and exhaust to exit through single common hole.
CONDENSATE NEUTRALIZER KIT - 1NK0301
Neutralizer cartidge has a 1/2" plastic tube fittings for installa­tion in the drain line. Calcium carbonate refill media is also avaiable from the Source 1 Parts (p/n 026-30228-000).
Sidewall Vent Termination - 1HT0901
For use on sidewall, two-pipe installations only. Provides a more attractive termination for locations where the terminal is visible on the side of the home.
FIELD INSTALLED ACCESSORIES - ELECTRICAL
MODEL NO. DESCRIPTION USED WITH
2TH07700124
2TH13700424
2TB17700424
2ET07700224 2CT03700124 TWINNING CONTROL ALL MODELS
THERMOSTAT - One-stage heat/cool. Manual changeover, integral
subbase. System Switch: Cool-Off-Heat. Fan Switch: Auto-On.
THERMOSTAT- One-stage heat. Deluxe 24V with heat only sub­base, does not include fan switch. NOTE: For one-stage cool or one-stage heat/cool, must be used with subbase 2TB17700424.
SUBBASE (24V) - One-stage heat/cool. Manual changeover, inte-
gral subbase. System Switch: Cool-Off-Heat. Fan Switch: Auto-On.
THERMOSTAT- One-stage heat/cool.Programmable changeover,
with subbase. System Switch: Cool-Off-Heat. Fan Switch: Auto-On.
EXTERNAL BOTTOM RETURN FILTER RACK W/FILTER - Provides a cleanable, high velocity type filter and filter rack. Attaches to the bottom of the furnace.
1BR0314 - For 14-1/2” cabinets 1BR0317 - For 17-1/2" cabinets 1BR0321 - For 21" cabinets 1BR0324 - For 24-1/2" cabinets
HIGH ALTITUDE PRESSURE SWITCHES -
These accessory kits may be used to convert units for high altitude operation. Conversion must be made by qualified dis­tributor or dealer personnel.
1PS0501 1PS0502 1PS0503 1PS0504 1PS0505 1PS0506
HIGH ALTITUDE PRESSURE
SWITCH KIT
(Does Not Include Orifices)
ALL MODELS
FOR APPLICATION
INFORMATION
SEE FORM
035-20506-001
6 Unitary Products Group
Page 7
NOTES
036-21581-001 Rev. B (0904)
Unitary Products Group 7